期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Suppression of laser power error in a miniaturized atomic co-magnetometer based on split ratio optimization
1
作者 张伟佳 范文峰 +1 位作者 范时秒 全伟 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第3期180-186,共7页
A miniaturized atomic spin-exchange relaxation-free(SERF)co-magnetometer measures angular velocity using a balanced polarimetry technique which is easily affected by the laser power.A laser power closed-loop control s... A miniaturized atomic spin-exchange relaxation-free(SERF)co-magnetometer measures angular velocity using a balanced polarimetry technique which is easily affected by the laser power.A laser power closed-loop control system is usually used to suppress the fluctuation of the laser power.Although this method can greatly eliminate the fluctuation of the in-loop laser power(the feedback laser),it cannot fully eliminate the fluctuation of the out-of-loop laser power(the signal measurement laser).This leads to SERF gyroscope laser power error,which reduces the inertial measurement accuracy.In this paper,the influence mechanism of the split ratio(the ratio of the in-loop laser power to the out-of-loop laser power)on the out-of-loop laser power control accuracy is analyzed by establishing a laser power transmission model inside and outside the loop.Moreover,a method is developed to improve the out-of-loop laser power stability by optimizing the split ratio.Comparative experiments showed that the relative Allan standard deviation of the out-of-loop laser power decreased from 5.48×10^(-6)to 2.62×10^(-6)at 100 s,and decreased by an order of magnitude from 1.76×10^(-5)to 3.30×10^(-6)at1000 s.Correspondingly,the rate ramp coefficient in the Allan standard deviation curve of the SERF gyroscope test data decreased from 1.312[(°/h)/h]to 0.246[(°/h)/h].And the bias stability increased from 0.032°/h to 0.019°/h.Therefore,the proposed method can improve the long-term stability of the probe laser power and effectively suppress the laser power error of the SERF gyroscope. 展开更多
关键词 atomic gyroscope spin-exchange relaxation-free laser power stability error suppression
下载PDF
Far-Infrared Laser Diagnostics in EAST
2
作者 史楠 高翔 +5 位作者 揭银先 张寿彪 曾龙 王二辉 杨耀 刘子奚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2011年第3期347-351,共5页
Structure, improvements and experiment results of a vertical three-channel far- in- frared (FIR) hydrogen cyanide (HCN) laser interferometer, operated routinely in EAST to measure the electron density profile, are... Structure, improvements and experiment results of a vertical three-channel far- in- frared (FIR) hydrogen cyanide (HCN) laser interferometer, operated routinely in EAST to measure the electron density profile, are presented. Moreover, a five-channel deuterium cyanide (DCN) laser interferometer was developed successfully. Some key issues confronted in development, including the economization of working gas and the solution to atmospheric absorption, are resolved and described in detail. 展开更多
关键词 plasma electron density FIR laser interferometer laser power stabilization atmospheric absorption
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部