A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on differe...A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.展开更多
A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the...A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.展开更多
Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of a...Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of another method that enables remote transmission of the pharmacological properties of a medicament into a human body with the application of low-level laser radiation as the light source. 18 patients with different viral diseases were treated with the antiviral drugs placed into the field formed by the unexplained properties of low-level laser radiation of the “device for transfer of the pharmacological properties of a drug into the patient’s body”. This resulted in improvement of the patient’s condition, the absence of side effects and adverse reactions when using drugs in the proposed device and shortened therapy period for patients with chronic hepatitis C infection and Covid-19 patients. The long-term follow-up of the patients with chronic hepatitis B infection showed that hepatitis B virus remained at low replication levels under the influence of the therapy, which made it possible to avoid such formidable complications of the disease as cirrhosis of the liver and liver cancer.展开更多
文摘A novel frame shift and integral technique for the enhancement of low light level moving image sequence is introduced. According to the technique, motion parameters of target are measured by algorithm based on difference processing. To obtain spatial relativity, images are shifted according to the motion parameters. As a result, the processing of integral and average can be applied to images that have been shifted. The technique of frame shift and integral that includes the algorithm of motion parameter determination is discussed, experiments with low light level moving image sequences are also described. The experiment results show the effectiveness and the robustness of the parameter determination algorithm, and the improvement in the signal-to-noise ratio (SNR) of low light level moving images.
文摘A mathematical model of quantum noise having much effect on the low light imaging system is set up. To simulate the quantum noise, the random numbers obeying noise distribution must be formed and are weighted on the basis of the model created. Three uniform random sequences are built by the linear congruential method, of which two are used to form integer number and decimal fraction parts of the new random sequence respectively and the third to shuffle the new sequence. And then a Gauss sequence is formed out of uniform distribution by a function transforming method. It actualizes the simulation in real time of quantum noise in the low light imaging system, where video flow is extracted in real time, the noise summed up and played back side by side with the original video signs by a simulation software.
文摘Low-level laser therapy (LLLT) or cold laser has been used in medicine for several decades. However, the method utilizes a direct contact of the light beam with a patient. Further research resulted in development of another method that enables remote transmission of the pharmacological properties of a medicament into a human body with the application of low-level laser radiation as the light source. 18 patients with different viral diseases were treated with the antiviral drugs placed into the field formed by the unexplained properties of low-level laser radiation of the “device for transfer of the pharmacological properties of a drug into the patient’s body”. This resulted in improvement of the patient’s condition, the absence of side effects and adverse reactions when using drugs in the proposed device and shortened therapy period for patients with chronic hepatitis C infection and Covid-19 patients. The long-term follow-up of the patients with chronic hepatitis B infection showed that hepatitis B virus remained at low replication levels under the influence of the therapy, which made it possible to avoid such formidable complications of the disease as cirrhosis of the liver and liver cancer.