Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literatu...Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literature.On the other hand,investigations regarding the irregular base-isolated reinforced concrete structures’performance when subjected to pulse-like earthquakes are very scarce.The severity of pulse-like earthquakes emerges from their ability to destabilize the base-isolated structure by remarkably increasing the displacement demands.Thus,this study is intended to investigate the effects of pulse-like earthquake characteristics on the behavior of low-rise irregular base-isolated reinforced concrete structures.Within the study scope,investigations related to the impact of the pulse-like earthquake characteristics,irregularity type,and isolator properties will be conducted.To do so,different values of damping ratios of the base isolation system were selected to investigate the efficiency of the lead rubber-bearing isolator.In general,the outcomes of the study have shown the significance of vertical irregularity on the performance of base-isolated structures and the considerable effect of pulse-like ground motions on the buildings’behavior.展开更多
An artificially accelerated alternation of aging and seawater erosion test of rubber materials used in lead rubber bearing(LRB)was performed,mainly to study the time-varying laws of rubber materials mechanical propert...An artificially accelerated alternation of aging and seawater erosion test of rubber materials used in lead rubber bearing(LRB)was performed,mainly to study the time-varying laws of rubber materials mechanical properties.Time-varying laws of the Mooney–Rivlin and Neo-Hookean constitutive parameters of rubber materials under the alternation of aging and seawater erosion were also analyzed.Results indicate that the rubber material mechanical properties were significantly affected by alternation of aging and seawater erosion.Hardness and elongation stress increased exponentially with test time.And 120 days after the test,the hardness increased by 14%,the maximum percentage increase in stress of 124.76%occurred at 100%constant elongation and the minimum percentage increase in stress of 68.32%occurred at 300%constant elongation;Tensile strength and elongation at break decreased by 44.96%and 53.09%.Besides,constitutive parameters of Mooney–Rivlin and Neo-Hookean all changed greatly with test duration.Finally,time-varying laws of constitutive parameters were verified by comparing the simulated and experimental results of the lead rubber bearing’s stiffness.Research results are of great significance to the seismic performance research and life-cycle performance analysis of offshore traffic engineering such as cross-sea bridges and bridges in the marine environment.展开更多
Seismic earthquakes are a real danger for the construction evolution of high rise buildings.The rate of earthquakes around the world is noteworthy in a wide range of construction areas.In this study,we present the dyn...Seismic earthquakes are a real danger for the construction evolution of high rise buildings.The rate of earthquakes around the world is noteworthy in a wide range of construction areas.In this study,we present the dynamic behavior of a high-rise RC building with dynamic isolators(lead-rubber-bearing),in comparison with a traditional shear wall system of the same building.Seismic isolation has been introduced in building construction to increase the structural stability and to protect the non-structural components against the damaging effects of an earthquake.In order to clarify the influence of incorporating lead rubber bearing isolators in the seismic response and in reducing seismic damages;a comparative study is performed between a fixed base system(shear wall system)and an isolated base system(Lead Rubber Bearing)on an irregular high rise reinforced concrete(RC)building located in Beirut consisting of 48 storeys almost asymmetric orthogonally.For this purpose,a non-linear analysis of a real earthquake acceleration record(EI Centro seismic signal)is conducted,so that the mode shapes,the damping ratio and the natural frequencies of the two models are obtained using ETABS software.The results prove a substantial elongation of the building period,as well as a reduction in the building displacement,the roof acceleration,the inter-storey drift ratio and the base shear force of isolated building relative to fixed-base building.This study proves that this technology is applicable to high rise buildings with acceptable results.展开更多
The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in t...The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in this paper is effective in the resolution of difficulties in strong vertical capacity and vertical damping of three dimensional isolation bearings. It effectively suppresses rocking motions as well. The analytical model and motion equations of multi dimensional seismic responses of 3D base isolated frame structures are established. Taking a five storey frame structure as an example, an extensive simulation analysis is carried out. The results show that the 3D base isolated structure with the proposed 3DB is effective in 3D isolation; it can reduce seismic responses by 50 % compared to a non isolated structure. Therefore, the 3D isolation problem in building can be solved easily and effectively with the 3DB proposed in this paper.展开更多
A design procedure for improving the seismic performance of unequal-span underground structures by installing isolation devices at the top end of columns is proposed based on the seismic failure mode of frame-type und...A design procedure for improving the seismic performance of unequal-span underground structures by installing isolation devices at the top end of columns is proposed based on the seismic failure mode of frame-type underground structures and the design concept of critical support columns.A two-dimensional finite element model(FEM)for a soil-underground structure with an unequal-span interaction system was established to shed light on the effects of a complex subway station with elastic sliding bearings(ESB)and lead rubber bearings(LRB)on seismic mitigation.It was found that the stiffness and internal force distribution of the underground structure changed remarkably with the installation of isolation devices at the top end of the columns.The constraints of the beam-column joints were significantly weakened,resulting in a decrease in the overall lateral stiffness and an increase in the structural lateral displacement.The introduction of the isolation device effectively reduces the internal force and seismic damage of the frame column;however,the tensile damage to the isolation structure,such as the roof,bottom plate,and sidewall,significantly increased compared to those of the non-isolation structure.Although the relative slip of the ESB remains within a controllable range under strong earthquake excitation as well as frame columns with stable vertical support and self-restoration functions,the LRB shows a better performance during seismic failure and better lateral displacement response of the unequal-span underground structure.The analysis results provide new ideas and references for promoting the application of seismic isolation technology in underground structures.展开更多
Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes...Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes, low and moderate earthquakes are also mandatory to be investigated in Turkey and some other countries. One of the main reasons is to protect the integrity of non-structural elements or machines during these types of earthquakes. The selection of appropriate seismic isolation is typically decided based on their forcedisplacement characteristics and amount of energy dissipation per cycle. The same energy dissipation per cycle(EDC) can be achieved by high force-low displacement or low force-high displacement response. The focus of this research is given to identify the performance of ball rubber bearing isolation systems compared to different or similar EDC units such as elastomeric bearings and lead rubber bearings through a series of shake table tests performed at low to moderate earthquake levels. Shake table tests were conducted on an almost full scale short span bridge. The tests have revealed that the ball rubber bearings are superior to elastomeric bearings in terms of EDC and can match EDC of LRB. However, although LRB and BRB have the same EDC, BRB is more beneficial to use under low to moderate earthquakes since BRB can transmit less force with larger displacement compared to LRB and LRB can sometimes stay in elastic range with an ineffective EDC as a stiffer elastomeric bearing.展开更多
文摘Nowadays,an extensive number of studies related to the performance of base isolation systems implemented in regular reinforced concrete structures subjected to various types of earthquakes can be found in the literature.On the other hand,investigations regarding the irregular base-isolated reinforced concrete structures’performance when subjected to pulse-like earthquakes are very scarce.The severity of pulse-like earthquakes emerges from their ability to destabilize the base-isolated structure by remarkably increasing the displacement demands.Thus,this study is intended to investigate the effects of pulse-like earthquake characteristics on the behavior of low-rise irregular base-isolated reinforced concrete structures.Within the study scope,investigations related to the impact of the pulse-like earthquake characteristics,irregularity type,and isolator properties will be conducted.To do so,different values of damping ratios of the base isolation system were selected to investigate the efficiency of the lead rubber-bearing isolator.In general,the outcomes of the study have shown the significance of vertical irregularity on the performance of base-isolated structures and the considerable effect of pulse-like ground motions on the buildings’behavior.
基金This work was supported by the Programme for National Natural Science Foundation of China(52078150,51878196)National Key R&D Program of China(2019YFE0112500)2019 Guangzhou University Full-Time Graduate“Basic Innovation”Project(2019GDJC-D11).
文摘An artificially accelerated alternation of aging and seawater erosion test of rubber materials used in lead rubber bearing(LRB)was performed,mainly to study the time-varying laws of rubber materials mechanical properties.Time-varying laws of the Mooney–Rivlin and Neo-Hookean constitutive parameters of rubber materials under the alternation of aging and seawater erosion were also analyzed.Results indicate that the rubber material mechanical properties were significantly affected by alternation of aging and seawater erosion.Hardness and elongation stress increased exponentially with test time.And 120 days after the test,the hardness increased by 14%,the maximum percentage increase in stress of 124.76%occurred at 100%constant elongation and the minimum percentage increase in stress of 68.32%occurred at 300%constant elongation;Tensile strength and elongation at break decreased by 44.96%and 53.09%.Besides,constitutive parameters of Mooney–Rivlin and Neo-Hookean all changed greatly with test duration.Finally,time-varying laws of constitutive parameters were verified by comparing the simulated and experimental results of the lead rubber bearing’s stiffness.Research results are of great significance to the seismic performance research and life-cycle performance analysis of offshore traffic engineering such as cross-sea bridges and bridges in the marine environment.
文摘Seismic earthquakes are a real danger for the construction evolution of high rise buildings.The rate of earthquakes around the world is noteworthy in a wide range of construction areas.In this study,we present the dynamic behavior of a high-rise RC building with dynamic isolators(lead-rubber-bearing),in comparison with a traditional shear wall system of the same building.Seismic isolation has been introduced in building construction to increase the structural stability and to protect the non-structural components against the damaging effects of an earthquake.In order to clarify the influence of incorporating lead rubber bearing isolators in the seismic response and in reducing seismic damages;a comparative study is performed between a fixed base system(shear wall system)and an isolated base system(Lead Rubber Bearing)on an irregular high rise reinforced concrete(RC)building located in Beirut consisting of 48 storeys almost asymmetric orthogonally.For this purpose,a non-linear analysis of a real earthquake acceleration record(EI Centro seismic signal)is conducted,so that the mode shapes,the damping ratio and the natural frequencies of the two models are obtained using ETABS software.The results prove a substantial elongation of the building period,as well as a reduction in the building displacement,the roof acceleration,the inter-storey drift ratio and the base shear force of isolated building relative to fixed-base building.This study proves that this technology is applicable to high rise buildings with acceptable results.
文摘The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in this paper is effective in the resolution of difficulties in strong vertical capacity and vertical damping of three dimensional isolation bearings. It effectively suppresses rocking motions as well. The analytical model and motion equations of multi dimensional seismic responses of 3D base isolated frame structures are established. Taking a five storey frame structure as an example, an extensive simulation analysis is carried out. The results show that the 3D base isolated structure with the proposed 3DB is effective in 3D isolation; it can reduce seismic responses by 50 % compared to a non isolated structure. Therefore, the 3D isolation problem in building can be solved easily and effectively with the 3DB proposed in this paper.
基金the research funding provided by the National Natural Science Foundation of China(NSFC,No.51978333)the SINOMACH Science and Technology Major Project(SINOMAST-ZDZX-2020-03)。
文摘A design procedure for improving the seismic performance of unequal-span underground structures by installing isolation devices at the top end of columns is proposed based on the seismic failure mode of frame-type underground structures and the design concept of critical support columns.A two-dimensional finite element model(FEM)for a soil-underground structure with an unequal-span interaction system was established to shed light on the effects of a complex subway station with elastic sliding bearings(ESB)and lead rubber bearings(LRB)on seismic mitigation.It was found that the stiffness and internal force distribution of the underground structure changed remarkably with the installation of isolation devices at the top end of the columns.The constraints of the beam-column joints were significantly weakened,resulting in a decrease in the overall lateral stiffness and an increase in the structural lateral displacement.The introduction of the isolation device effectively reduces the internal force and seismic damage of the frame column;however,the tensile damage to the isolation structure,such as the roof,bottom plate,and sidewall,significantly increased compared to those of the non-isolation structure.Although the relative slip of the ESB remains within a controllable range under strong earthquake excitation as well as frame columns with stable vertical support and self-restoration functions,the LRB shows a better performance during seismic failure and better lateral displacement response of the unequal-span underground structure.The analysis results provide new ideas and references for promoting the application of seismic isolation technology in underground structures.
基金supported by TUBITAK through the 110G093 research project and TUBITAK BIDEB 2215 Program
文摘Seismic isolation systems designed for extreme events may likely experience low to moderate earthquakes during the design life of the structure rather than the extreme event itself.In new seismic building design codes, low and moderate earthquakes are also mandatory to be investigated in Turkey and some other countries. One of the main reasons is to protect the integrity of non-structural elements or machines during these types of earthquakes. The selection of appropriate seismic isolation is typically decided based on their forcedisplacement characteristics and amount of energy dissipation per cycle. The same energy dissipation per cycle(EDC) can be achieved by high force-low displacement or low force-high displacement response. The focus of this research is given to identify the performance of ball rubber bearing isolation systems compared to different or similar EDC units such as elastomeric bearings and lead rubber bearings through a series of shake table tests performed at low to moderate earthquake levels. Shake table tests were conducted on an almost full scale short span bridge. The tests have revealed that the ball rubber bearings are superior to elastomeric bearings in terms of EDC and can match EDC of LRB. However, although LRB and BRB have the same EDC, BRB is more beneficial to use under low to moderate earthquakes since BRB can transmit less force with larger displacement compared to LRB and LRB can sometimes stay in elastic range with an ineffective EDC as a stiffer elastomeric bearing.