Flow rate and temperature are important parameters for design and operation of liquid lead–bismuth(Pb Bi) experimental loop. The PREKY facility was designed to study test technique of flow rate and local temperature ...Flow rate and temperature are important parameters for design and operation of liquid lead–bismuth(Pb Bi) experimental loop. The PREKY facility was designed to study test technique of flow rate and local temperature of Pb Bi loop. In this work, flow rate monitoring of molten Pb Bi was performed, and temperatures of the Pb Bi and pipe surface were measured. The results show that the flow rate of the venturi-nozzle flow meter had an uncertainty of ±5 % in the range of 0.6–2.0 m/s, and the maximum temperature difference between the Pb Bi and pipe surface was about 8 ℃.展开更多
基金supported by ITER 973 project (Nos. 2014GB112002 and 2014GB116000)Strategic Priority Research Program of Chinese Academy of Sciences (No. XDA03040200)Foundation of President of Hefei Institute of Physical Science (No. YZJJ201328)
文摘Flow rate and temperature are important parameters for design and operation of liquid lead–bismuth(Pb Bi) experimental loop. The PREKY facility was designed to study test technique of flow rate and local temperature of Pb Bi loop. In this work, flow rate monitoring of molten Pb Bi was performed, and temperatures of the Pb Bi and pipe surface were measured. The results show that the flow rate of the venturi-nozzle flow meter had an uncertainty of ±5 % in the range of 0.6–2.0 m/s, and the maximum temperature difference between the Pb Bi and pipe surface was about 8 ℃.