In the present work, tracking phenomenon in Silicone rubber material has beenstudied under AC and DC voltage, with ammonium chloride as a contaminant. It is observed that thetracking is more severe under the DC voltag...In the present work, tracking phenomenon in Silicone rubber material has beenstudied under AC and DC voltage, with ammonium chloride as a contaminant. It is observed that thetracking is more severe under the DC voltages. The tracking time is less under negative DC comparedto the positive DC voltage. The tracking mechanism is explained in detail. The leakage currentduring the tracking studies was as measured and the moving average technique was adopted tounderstand the trend in current flow. The leakage current magnitude is high with thermally agedspecimens compared to the virgin specimen, irrespective of the type of applied voltage. It isrealized that the tracking time and the leakage current magnitude shows an inverse relationship.展开更多
The macro-bending induced optical fiber cladding modes frustrated total internal reflection effect is used to realize the liquid level probe with a simple structure of single macro-bend polymer optical fiber loop. The...The macro-bending induced optical fiber cladding modes frustrated total internal reflection effect is used to realize the liquid level probe with a simple structure of single macro-bend polymer optical fiber loop. The test results show that the extinction ratio reaches 1.06dB. "First bath" phenomenon is not obvious (about 0.8%). The robustness of the sensor is better, and the ability of anti-pollution is stronger compared with the conventional sensors. The process of making this sensing probe is extremely easy, and the cost is very low.展开更多
文摘In the present work, tracking phenomenon in Silicone rubber material has beenstudied under AC and DC voltage, with ammonium chloride as a contaminant. It is observed that thetracking is more severe under the DC voltages. The tracking time is less under negative DC comparedto the positive DC voltage. The tracking mechanism is explained in detail. The leakage currentduring the tracking studies was as measured and the moving average technique was adopted tounderstand the trend in current flow. The leakage current magnitude is high with thermally agedspecimens compared to the virgin specimen, irrespective of the type of applied voltage. It isrealized that the tracking time and the leakage current magnitude shows an inverse relationship.
基金This work was supported by the Major State Basic Research Development Program of China (Grant No. 2012CB723404) and the National Natural Science Foundation of China (No. 51275491 and No. 61275166).
文摘The macro-bending induced optical fiber cladding modes frustrated total internal reflection effect is used to realize the liquid level probe with a simple structure of single macro-bend polymer optical fiber loop. The test results show that the extinction ratio reaches 1.06dB. "First bath" phenomenon is not obvious (about 0.8%). The robustness of the sensor is better, and the ability of anti-pollution is stronger compared with the conventional sensors. The process of making this sensing probe is extremely easy, and the cost is very low.