期刊文献+
共找到1,077篇文章
< 1 2 54 >
每页显示 20 50 100
An Intelligent Design of Electron Lens System
1
作者 Let Wei Tong Linsu & Wu Shengli (Electronic Engineering Department of Southeast University, Naming 210096, P. R. China) (Shenyang Aircraft Manufacture Company) 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 1996年第1期75-86,共12页
At present, the main work of electron optical system CAD is solving equations and calculating mumerical values. However, the design perhaps needs more inference and expertise than numerical calculations because the st... At present, the main work of electron optical system CAD is solving equations and calculating mumerical values. However, the design perhaps needs more inference and expertise than numerical calculations because the structure of electron lens system is complicated. In this paper, a primary expert system is applied to design the electron lens system intelligently. This expert system is combined with SEU-3D program which is used to simulate the electron optical system to optimize the electron lens systems. In spite of this, the expert system which is established in this paper can also be used to diagnose the electron lens system. Although the knowledge base is small and rules are not abundant, this paper has used this system to obtain some very useful results. The initial success with this system suggests that further work need to be done whether more rules and knowledge will be added to extend the ability of expert system. 展开更多
关键词 Intelligent design of electron lens system Expert system Knowledge base. SEU-3D Program
下载PDF
Aberration-free two-thin-lens systems based on negative-index materials
2
作者 林志立 丁婕深 张朴 《Chinese Physics B》 SCIE EI CAS CSCD 2008年第3期954-959,共6页
Since the complete correction of all five monochromatic Seidel aberrations for a singlet lens with random shape or a two-thin-lens system is unprocurable merely by using the conventional positive-index materials both ... Since the complete correction of all five monochromatic Seidel aberrations for a singlet lens with random shape or a two-thin-lens system is unprocurable merely by using the conventional positive-index materials both in theory and practice, this paper proposes that when one or both of the two lenses is/are made from negative-index materials, an imaging system composed of a pair of spherical thin lenses is possible to form a real image, in air, free from all five monochromatic Seidel aberrations. The calculated numerical solutions to the structural parameters of such lens systems possessing superior performance are provided and examples of them are illustrated for the given combinations of the two lenses' refractive indices, including an ultimately-remote imaging system. 展开更多
关键词 negative refraction negative-index materials Seidel aberrations thin lens
下载PDF
Path Integral Formulation for Wave Effect in Multilens System
3
作者 Kazuhiro Yamamoto 《International Journal of Astronomy and Astrophysics》 2017年第3期221-229,共9页
A formula to investigate the wave effect in a multi-lens system is presented on the basis of a path integral formalism by generalizing the work by Nakamura and Deguchi (1999). The wave effect of a system with two lens... A formula to investigate the wave effect in a multi-lens system is presented on the basis of a path integral formalism by generalizing the work by Nakamura and Deguchi (1999). The wave effect of a system with two lenses is investigated in an analytic way as a simple application to demonstrate usefulness of the formula and variety of wave effect in multi-lens system. 展开更多
关键词 COSMOLOGY GRAVITATIONAL lensING WAVE OPTICS
下载PDF
Contact lens as an emerging platform for ophthalmic drug delivery:A systematic review
4
作者 Hongyu Yang Ming Zhao +8 位作者 Dandan Xing Jian Zhang Ting Fang Faxing Zhang Zhihao Nie Yaming Liu Lihua Yang Ji Li Dongkai Wang 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2023年第5期26-50,共25页
The number of people with eye diseases has increased with the use of electronics.However,the bioavailability of eye drops remains low owing to the presence of the ocular barrier and other reasons.Although many drug de... The number of people with eye diseases has increased with the use of electronics.However,the bioavailability of eye drops remains low owing to the presence of the ocular barrier and other reasons.Although many drug delivery systems have been developed to overcome these problems,they have certain limitations.In recent years,the development of contact lenses that can deliver drugs for long periods with high bioavailability and without affecting vision has increased the interest in using contact lenses for drug delivery.Hence,a review of the current state of research on drug delivery contact lenses has become crucial.This article reviews the key physical and chemical properties of drug-laden contact lenses,development and classification of contact lenses,and features of the commonly used materials.A review of the methods commonly used in current research to create contact lenses has also been presented.An overview on how drug-laden contact lenses can overcome the problems of high burst and short release duration has been discussed.Overall,the review focuses on drug delivery methods using smart contact lenses,and predicts the future direction of research on contact lenses. 展开更多
关键词 Drug-loaded contact lenses Drug-loaded smart contact lenses Corneal diseases Ocular drug delivery Key attributes of contact lenses
下载PDF
Intraocular lens exchange or explantation post cataract surgery
5
作者 Arundhati Dvivedi Somasheila I Murthy Sukesh Manga 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第11期2031-2036,共6页
AIM:To report incidence,indications,and visual outcomes of intraocular lens(IOL)exchange/explantation surgery.METHODS:Retrospective analysis of 60 eyes requiring IOL exchange/explantation surgery between 1^(st) Januar... AIM:To report incidence,indications,and visual outcomes of intraocular lens(IOL)exchange/explantation surgery.METHODS:Retrospective analysis of 60 eyes requiring IOL exchange/explantation surgery between 1^(st) January 2017 and 31^(st) December 2022.The overall outcomes as well as comparison between the trainee versus experienced surgeons were analyzed.RESULTS:Out of 39778 cataract surgeries(with no preexisting ocular co-morbidities)during a six-year period(2017-2022),60(0.15%)needed IOL exchange/explantation.Surgeons-under-training performed 36/60 cases(60%)while 24/60(40%)were by experienced surgeons.The commonest indication was subluxated IOL in 26(43.3%),followed by dislocated IOL in 20(33.3%),postoperative refractive surprise in 7(11.6%),IOL induced uveitis in five and broken haptic in two eyes.Twenty-four(40%)eyes had intraoperative complications during primary surgery.Posterior chamber IOL(PCIOL)was the commonest secondary IOL in 21(35%)eyes,scleral fixated in 20(31.6%),anterior chamber IOL(ACIOL)in 13(21.6%),iris fixated IOL in three(5%)and three eyes(5%)were left aphakic.The mean time between primary and secondary surgery was 168d(168±338.8).Best corrected visual acuity(BCVA)of>20/60 was obtained in 43 eyes(71.66%),20/80-20/200 in 14(23.33%),20/250 in two and hand movements in one.No statistically significant difference in visual outcome was noted at post-op one month between trainees versus experienced surgeons(UCVA 0.45±0.29 vs 0.53±0.32,P=0.20,BCVA 0.34±0.25 vs 0.37±0.26,P=0.69).CONCLUSION:IOL subluxation as the commonest indication and posterior capsular rupture is the commonest intraoperative risk factor.This complication can be effectively addressed with selection of the appropriate secondary IOL achieving good visual outcomes in over 70% of patients. 展开更多
关键词 intraocular lens exchange subluxated intraocular lens dislocated intraocular lens posterior capsular rupture trainee surgeon experienced surgeon
下载PDF
Sutured scleral fixation of existing subluxated/dislocated acrylic one-piece intraocular lenses
6
作者 Wei-Yu Huang Yung-Jen Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期665-669,共5页
AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a ... AIM:To evaluate the visual and refractive outcomes in cases after sutured scleral fixation of existing subluxated or dislocated acrylic one-piece intraocular lenses(IOLs).METHODS:This study retrospectively enrolled a consecutive series of patients who underwent a surgery of sutured existing subluxated or dislocated IOLs from October 2018 to June 2020.All patients underwent comprehensive preoperative and postoperative ophthalmologic examination,and data were collected including age,sex,surgical indications,best-corrected visual acuity,refractive error,intraocular pressure.Presence of intraoperative and postoperative surgical complications was documented.RESULTS:A total of 20 consecutive cases were enrolled for analysis with mean final follow-up period 9.8±5.3mo.Visual acuity improved from a mean of 0.35(0.46±0.32 logMAR)preoperatively to 0.61(0.21±0.18 logMAR)at the 3-month follow-up(P=0.002).The mean amount of preoperative keratometric astigmatism and total postoperative refractive astigmatism was-1.24±0.80 diopters(D)and-1.42±0.97 D,respectively.There was no statistically significant difference between preoperative and postoperative astigmatism(P=0.156).The mean IOL-induced astigmatism was-0.23±0.53 D.The mean spherical equivalent at the 3-month follow-up was-0.1±0.94 D.No major complications were noted during the follow-up period.CONCLUSION:Surgical techniques using sutured scleral fixation of existing subluxated or dislocated acrylic one-piece IOLs result in favorable visual and refractive outcomes without major complications. 展开更多
关键词 intraocular lens dislocation intraocular lens subluxation lens dislocation lens subluxation scleral fixation
下载PDF
Design and fabrication of compound varifocal lens driven by polydimethylsiloxane film elastic deformation
7
作者 缪文浩 韩泽峰 +3 位作者 赵瑞 梁忠诚 寇松峰 徐荣青 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期342-346,共5页
A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave... A compound varifocal lens based on electromagnetic drive technology is designed and fabricated, where the polydimethylsiloxane(PDMS) film acts as a driving component, while the PDMS biconvex lens and the plane-concave lens form a coaxial compound lens system. The plane-concave lens equipped with driving coils is installed directly above the PDMS lens surrounded by the annular magnet. When different currents are applied, the annular magnet moves up and down, driving the PDMS film to undergo elastic deformation, and then resulting in longitudinal movement of the PDMS lens. The position change of the PDMS lens changes the focal length of the compound lens system. To verify the feasibility and practicability of this design, a prototype of our compound lens system is fabricated in experiment. Our proposed compound lens shows that its zoom ability reaches 9.28 mm when the current ranges from -0.20 A to 0.21 A. 展开更多
关键词 compound varifocal lens PDMS film elastic deformation focal length electromagnetic force zoom ability
下载PDF
Early clinical outcome with lens position adjustment following implantable collamer lens surgery
8
作者 Qian Zhang Bo Zhao +2 位作者 Xue-Fei Yang Zhang-Lin Liu Yue Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1654-1658,共5页
AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient recei... AIM:To observe early clinical outcome with lens position adjustment following the implantable collamer lens(ICL)surgery.METHODS:Sixty patients were selected for this retrospective study.One eye from each patient received Toric ICL for astigmatism correction,and the other received non-astigmatic ICL surgery using horizontal position.Patients with higher postoperative arch height were selected,and their non-astigmatic eye clinical outcome were observed after ICL surgery at 1wk,1,and 3mo.The clinical measurements included uncorrected visual acuity(UCVA),intraocular pressure(IOP),refractive state,corneal endothelium cell count,and arch height.Three months later,the ICL in each patient’s non-astigmatic eye was adjusted to the vertical from the horizontal position.The results were compared before and 1wk,1,and 3mo after adjustment.RESULTS:UCVA and IOP were significantly reduced 1wk after position adjustment compared to 1wk after ICL implantation(P<0.05).The patients demonstrated significantly reduced arch height and corneal endothelium cell count 1wk,1,and 3mo after adjusting position compared to 1wk,1,and 3mo after ICL implantation(P<0.05).However,there was no significant difference in refraction between 1wk,1,and 3mo after ICL implantation and position adjustment(P>0.05).CONCLUSION:Early positioning adjustment postphakic ICL implantation can benefit patients with adjusted arch height or higher IOP.Despite the good clinical effects,the doctors should pay attention to the potential for adverse effects on UCVA and corneal endothelium cells following early position adjustment after posterior chamber phakic ICL implantation. 展开更多
关键词 implantable collamer lens MYOPIA lens positional adjustment arch height intraocular pressure
下载PDF
Systematic bibliometric analysis of research hotspots and trends on the application of premium IOLs in the past 2 decades
9
作者 Liang-Pin Li Li-Yun Yuan +2 位作者 De-Shen Mao Xia Hua Xiao-Yong Yuan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期736-747,共12页
AIM:To analysis of research hotspots and trends on the application of premium intraocular lens(PIOLs)in the past 2 decades.METHODS:The literature search was performed on the Web of Science and included PIOLs studies p... AIM:To analysis of research hotspots and trends on the application of premium intraocular lens(PIOLs)in the past 2 decades.METHODS:The literature search was performed on the Web of Science and included PIOLs studies published between January 2000 and December 2022.The retrieved literature was collated and analyzed by R-tool’s Bibliometrix package,CitNetExplorer,CiteSpace and other software.RESULTS:A total of 1801 articles about PIOLs were obtained,most of which were published in Spain and the United States.The organization that published the most articles was the University of Valencia in Spain.Alió JL,and Montés-Micó R,from Spain were the most influential authors in this field.The Journal of Cataract and Refractive Surgery and Journal of Refractive Surgery were the core journals for this field;the top 10 cited articles mainly focus on postoperative satisfaction with multifocal intraocular lens(IOLs)and postoperative results of toric IOLs.Through the keyword analysis,we found that trifocal IOLs,astigmatism and extended depth of focus(EDoF)IOLs are the most discussed topics at present,and the importance of astigmatism and the clinical application of the new generation of PIOLs are the emerging research trends.CONCLUSION:Bibliometric analysis can effectively help to identify multilevel concerns in PIOLs research and the prevailing research trends in the realm of PIOLs encompass the adoption of EDoF IOLs,trifocal IOLs,and their respective Toric models. 展开更多
关键词 premium intraocular lens BIBLIOMETRIC H-INDEX cataract surgery global trends
下载PDF
Overexpression of TRPV1 activates autophagy in human lens epithelial cells under hyperosmotic stress through Ca^(2+)-dependent AMPK/mTOR pathway
10
作者 Liu-Hui Huang Jiao Lyu +6 位作者 Sheng Chen Ting-Yi Liang Yu-Qing Rao Ping Fei Jing Li Hai-Ying Jin Pei-Quan Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期420-434,共15页
●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,... ●AIM:To explore whether autophagy functions as a cellular adaptation mechanism in lens epithelial cells(LECs)under hyperosmotic stress.●METHODS:LECs were treated with hyperosmotic stress at the concentration of 270,300,400,500,or 600 mOsm for 6,12,18,24h in vitro.Polymerase chain reaction(PCR)was employed for the mRNA expression of autophagyrelated genes,while Western blotting detected the targeted protein expression.The transfection of stub-RFP-sens-GFPLC3 autophagy-related double fluorescence lentivirus was conducted to detect the level of autophagy flux.Scanning electron microscopy was used to detect the existence of autolysosome.Short interfering RNA of autophagy-related gene(ATG)7,transient receptor potential vanilloid(TRPV)1 overexpression plasmid,related agonists and inhibitors were employed to their influence on autophagy related pathway.Flow cytometry was employed to test the apoptosis and intracellular Ca^(2+)level.Mitochondrial membrane potential was measured by JC-1 staining.The cell counting kit-8 assay was used to calculate the cellular viability.The wound healing assay was used to evaluate the wound closure rate.GraphPad 6.0 software was utilized to evaluate the data.●RESULTS:The hyperosmotic stress activated autophagy in a pressure-and time-dependent manner in LECs.Beclin 1 protein expression and conversion of LC3B II to LC3B I increased,whereas sequestosome-1(SQSTM1)protein expression decreased.Transient Ca^(2+)influx was stimulated caused by hyperosmotic stress,levels of mammalian target of rapamycin(mTOR)phosphorylation decreased,and the level of AMP-activated protein kinase(AMPK)phosphorylation increased in the early stage.Based on this evidence,autophagy activation through the Ca^(2+)-dependent AMPK/mTOR pathway might represent an adaptation process in LECs under hyperosmotic stress.Hyperosmotic stress decreased cellular viability and accelerated apoptosis in LECs and cellular migration decreased.Inhibition of autophagy by ATG7 knockdown had similar results.TRPV1 overexpression increased autophagy and might be crucial in the occurrence of autophagy promoted by hyperosmotic stress.●CONCLUSION:A combination of hyperosmotic stress and autophagy inhibition may be a promising approach to decrease the number of LECs in the capsular bag and pave the way for improving prevention of posterior capsular opacification and capsular fibrosis. 展开更多
关键词 CATARACT posterior capsular opacification lens epithelial cell hyperosmotic stress AUTOPHAGY apoptosis transient receptor potential vanilloid 1
下载PDF
Large-field objective lens for multi-wavelength microscopy at mesoscale and submicron resolution
11
作者 Xin Xu Qin Luo +7 位作者 Jixiang Wang Yahui Song Hong Ye Xin Zhang Yi He Minxuan Sun Ruobing Zhang Guohua Shi 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第6期41-56,共16页
Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously anal... Conventional microscopes designed for submicron resolution in biological research are hindered by a limited field of view,typically around 1 mm.This restriction poses a challenge when attempting to simultaneously analyze various parts of a sample,such as different brain areas.In addition,conventional objective lenses struggle to perform consistently across the required range of wavelengths for brain imaging in vivo.Here we present a novel mesoscopic objective lens with an impressive field of view of 8 mm,a numerical aperture of 0.5,and a working wavelength range from 400 to 1000 nm.We achieved a resolution of 0.74μm in fluorescent beads imaging.The versatility of this lens was further demonstrated through high-quality images of mouse brain and kidney sections in a wide-field imaging system,a confocal laser scanning system,and a two-photon imaging system.This mesoscopic objective lens holds immense promise for advancing multi-wavelength imaging of large fields of view at high resolution. 展开更多
关键词 mesoscopic objective lens large field-of-view high resolution MULTI-WAVELENGTH wide-field microscopy confocal laser scanning microscopy
下载PDF
Impact of multifocal gas-permeable lens designs on short-term choroidal response, axial length, and retinal defocus profile
12
作者 Muteb Alanazi Patrick Caroline +1 位作者 Amane Alshamrani Maria Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期247-256,共10页
AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defoc... AIM:To investigate the impact of multifocal gas permeable contact lens(MFGPCL)in various add power and distance/near area allocation on short-term changes of choroidal thickness(ChT),axial length(AL),and retinal defocus profile in young adults.METHODS:Seventeen young adults(2 males and 15 females;age 23.17±4.48y)were randomly assigned to wear two designs binocularly with a one-week washout period in between.Total of four MFGPCL designs were assessed.All designs were distance-center that varied in two add power(+1.50 and 3.00 D)and/or two distance zone(DZ)diameters(1.50 and 3.00 mm;design A:DZ 1.5/add 3.0,B:DZ 1.5/add 1.5,C:DZ 3.0/add 3.0,D:DZ 3.0/add 1.5).ChT,AL,and peripheral refraction data were collected on each subject at baseline,on days 1 and 7 of MFGPCL daily wear.ChT was assessed in four quadrants using a spectraldomain optical coherence tomography.RESULTS:AL was shortened by-26±44μm with lens C,-18±27μm with lens D,-13±29μm with lens A,and-8±30μm with lens B(all P<0.05).A significant overall increase in ChT was observed with all 4 designs(lens A:+6±6μm,B:+3±7μm,C:+8±7μm,and D:+8±7μm).Temporal and superior choroid exhibited more choroidal thickening associated with MFGPCL.All designs induced significant relative peripheral myopia(RPM)beyond the central 20o across the horizontal meridian in both nasal and temporal fields(P<0.05).CONCLUSION:MFGPCLs show a significant influence on ChT and AL,which are associated with significant increase in RPM after short-term wear.The reliability and feasibility of quantifying short-term changes in ChT support its use as a promising marker for the long-term efficacy of myopia-controlling treatments. 展开更多
关键词 CHOROID gas-permeable contact lens retinal defocus axial length MYOPIA
下载PDF
Effectiveness and safety of early lens extraction during par plana vitrectomy for proliferative diabetes retinopathy with mild cataract:a randomized clinical trial
13
作者 Wei-Bo Feng Lei Zheng +17 位作者 Ying-Qi Li Yong-Hao Li Guo-Ming Zhang Xian Wang Bing-Qian Liu Ling Jin Yi-Nuo Huang Yang-Fan Yang Zi-Dong Chen Da-Hui Ma Qing-Shan Chen Chao-Jun Qin Bing-Min Feng Zhu-Min Yang Xing Huang Cheng-Jie Yang Sheng-Hui Liu Ming-Xing Wu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期528-536,共9页
●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:T... ●AIM:To evaluate the effectiveness and safety of early lens extraction during pars plana vitrectomy(PPV)for proliferative diabetic retinopathy(PDR)compared to those of PPV with subsequent cataract surgery.●METHODS:This multicenter randomized controlled trial was conducted in three Chinese hospitals on patients with PDR,aged>45y,with mild cataracts.The participants were randomly assigned to the combined(PPV combined with simultaneously cataract surgery,i.e.,phacovitrectomy)or subsequent(PPV with subsequent cataract surgery 6mo later)group and followed up for 12mo.The primary outcome was the change in best-corrected visual acuity(BCVA)from baseline to 6mo,and the secondary outcomes included complication rates and medical expenses.●RESULTS:In total,129 patients with PDR were recruited and equally randomized(66 and 63 in the combined and subsequent groups respectively).The change in BCVA in the combined group[mean,36.90 letters;95%confidence interval(CI),30.35–43.45]was significantly better(adjusted difference,16.43;95%CI,8.77–24.08;P<0.001)than in the subsequent group(mean,22.40 letters;95%CI,15.55–29.24)6mo after the PPV,with no significant difference between the two groups at 12mo.The overall surgical risk of two sequential surgeries was significantly higher than that of the combined surgery for neovascular glaucoma(17.65%vs 3.77%,P=0.005).No significant differences were found in the photocoagulation spots,surgical time,and economic expenses between two groups.In the subsequent group,the duration of work incapacity(22.54±9.11d)was significantly longer(P<0.001)than that of the combined group(12.44±6.48d).●CONCLUSION:PDR patients aged over 45y with mild cataract can also benefit from early lens extraction during PPV with gratifying effectiveness,safety and convenience,compared to sequential surgeries. 展开更多
关键词 lens extraction pars plana vitrectomy proliferative diabetic retinopathy CATARACT simultaneously operations
下载PDF
Clinical prediction of insufficient vaults after implantable collamer lens implantation
14
作者 Jun Zhu Dan Cheng +3 位作者 Xue-Ying Zhu Fen-Fen Li Ye Yang Yu-Feng Ye 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1300-1306,共7页
AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants ... AIM:To determine the factors related to preoperative ocular characters that are predictive of insufficient vault(<250μm)after implantable collamer lens(ICL V4c;STAAR Surgical)implantation.METHODS:The participants underwent ICL surgery and were divided into the low(<250μm)and normal(250-1000μm)vault groups based on the postoperative vault at 3mo.The preoperative biometric parameters and clinical outcomes were compared between the two groups.The relationship between the 3-month vault values and preoperative ocular parameters were evaluated by Generalized estimating equations.RESULTS:Sixteen(23 eyes)and 36 patients(63 eyes)were in the low and normal vault groups,respectively.All implantation procedures were uneventful with no cataract formation in the early postoperative period.The sulcusto-sulcus lens rise(STSL)and iris ciliary angle(ICA)were correlated with vault at 3mo after surgery.Every 0.1 mm increase in STSL was associated with 38.9μm decrease in the postoperative 3-month vault.A rise of 1 degree in ICA is associated with a reduction of 4μm in vault.CONCLUSION:Eyes with a narrow ciliary sulcus are associated with a higher rate of low vault after ICL implantation,suggesting a need for adjustments to the ICL size in these patients.Evaluating the characteristics of the ciliary sulcus contributes valuable information to predict low vault after surgery. 展开更多
关键词 insufficient vault implantable collamer lens ciliary body posterior chamber
下载PDF
SIRT1 inhibits apoptosis of human lens epithelial cells through suppressing endoplasmic reticulum stress in vitro and in vivo
15
作者 Hui Cui Di Sun +3 位作者 Sheng Meng Tian-Ju Ma Zi Ye Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1205-1216,共12页
AIM:To explore the effect of silent information regulator factor 2-related enzyme 1(SIRT1)on modulating apoptosis of human lens epithelial cells(HLECs)and alleviating lens opacification of rats through suppressing end... AIM:To explore the effect of silent information regulator factor 2-related enzyme 1(SIRT1)on modulating apoptosis of human lens epithelial cells(HLECs)and alleviating lens opacification of rats through suppressing endoplasmic reticulum(ER)stress.METHODS:HLECs(SRA01/04)were treated with varying concentrations of tunicamycin(TM)for 24h,and the expression of SIRT1 and C/EBP homologous protein(CHOP)was assessed using real-time quantitative polymerase chain reaction(RT-PCR),Western blotting,and immunofluorescence.Cell morphology and proliferation was evaluated using an inverted microscope and cell counting kit-8(CCK-8)assay,respectively.In the SRA01/04 cell apoptosis model,which underwent siRNA transfection for SIRT1 knockdown and SRT1720 treatment for its activation,the expression levels of SIRT1,CHOP,glucose regulated protein 78(GRP78),and activating transcription factor 4(ATF4)were examined.The potential reversal of SIRT1 knockdown effects by 4-phenyl butyric acid(4-PBA;an ER stress inhibitor)was investigated.In vivo,age-related cataract(ARC)rat models were induced by sodium selenite injection,and the protective role of SIRT1,activated by SRT1720 intraperitoneal injections,was evaluated through morphology observation,hematoxylin and eosin(H&E)staining,Western blotting,and RT-PCR.RESULTS:SIRT1 expression was downregulated in TMinduced SRA01/04 cells.Besides,in SRA01/04 cells,both cell apoptosis and CHOP expression increased with the rising doses of TM.ER stress was stimulated by TM,as evidenced by the increased GRP78 and ATF4 in the SRA01/04 cell apoptosis model.Inhibition of SIRT1 by siRNA knockdown increased ER stress activation,whereas SRT1720 treatment had opposite results.4-PBA partly reverse the adverse effect of SIRT1 knockdown on apoptosis.In vivo,SRT1720 attenuated the lens opacification and weakened the ER stress activation in ARC rat models.CONCLUSION:SIRT1 plays a protective role against TM-induced apoptosis in HLECs and slows the progression of cataract in rats by inhibiting ER stress.These findings suggest a novel strategy for cataract treatment focused on targeting ER stress,highlighting the therapeutic potential of SIRT1 modulation in ARC development. 展开更多
关键词 silent information regulator factor 2-related enzyme 1 endoplasmic reticulum stress APOPTOSIS human lens epithelial cells CATARACT
下载PDF
Refractive outcomes after V4c Toric collamer lens implantation over 1y of follow-up
16
作者 Humberto Carreras-Díaz Josefina Reñones de Abajo +1 位作者 María del Rosario Carreras-Díaz Amalia Lorente-Velázquez 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第7期1322-1330,共9页
AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed inc... AIM:To evaluate refractive outcomes and corneal astigmatism changes after Toric implantable collamer lens with a central port(V4c T-ICL)implantation over 1y of follow-up.METHODS:A retrospective study was performed including 50 eyes of 50 patients that underwent V4c T-ICL implantation.Uncorrected(UDVA)and corrected(CDVA)distance visual acuities,refraction,refractive and corneal astigmatism changes and corneal coupling correction were evaluated preoperatively,1 and 12mo postoperatively.Vector analysis was used for astigmatism changes.Coefficient of adjustment(CAdj)was calculated for corneal coupling analysis.RESULTS:The mean UDVA achieved was 0.03 logMAR at 1mo and remained unchanged throughout the whole follow-up(P=0.193).At the last visit,84%of the eyes achieved a CDVA of 0.00 logMAR or better.Regarding spherical equivalent refraction(SEQ),96%of eyes were ranges of±1.00 D and 84%of them within±0.50 D.Also,94%of eyes had a remaining refractive cylinder within±1.00 D and 78%of them within±0.50 D.Both,SEQ and refractive cylinder,remain stable over the postoperative follow-up(P=1.000 and P=0.660,respectively).In terms of surgically induced astigmatism(SIA),no statistically significant differences were found over the follow-up(P=0.102)and under correction was found with a correction index lower than the unit at each visit.A keratometric astigmatism induced of 0.59±0.53(vector mean:0.26×73º)D was reached at the last visit.No significant changes in terms of corneal astigmatism orientation were reported over post-surgery visits(P=0.129 and P=0.097 at 1 and 12mo respectively).No clinical significance was found for CAdj on with-the-rule astigmatism.No postoperative complications resulting from the surgery were found.CONCLUSION:Refractive outcomes suggest that the V4c T-ICL implantation for correction of myopic astigmatism was satisfactory in terms of effectiveness,safety,and stability during 1y of follow-up.Corneal astigmatism induced by the incision around 0.5 D is achieved according to the remaining refractive cylinder found at one-year post-surgery.Corneal coupling analysis results in no unexpected spherical change. 展开更多
关键词 V4c Toric collamer lens corneal astigmatism surgically induced astigmatism corneal coupling
下载PDF
Rhegmatogenous retinal detachment in highly myopic eyes with implantable collamer lens
17
作者 Jun Li Chong-Lin Chen +2 位作者 Jia-Qing Li Xiao-Ling Liang Chun Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期392-396,共5页
AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who receiv... AIM:To investigate the clinical characteristics,treatment methods and outcomes of rhegmatogenous retinal detachment(RRD)in highly myopic eyes with implantable collamer lens(ICL).METHODS:High myopia patients who received treatment for nontraumatic RRD after ICL implantation surgery at the Retinal Department of Zhongshan Ophthalmic Center from Jan 2018 to Dec 2022 were reviewed.Comprehensive ophthalmologic examinations including visual acuity measurement and digital fundus photography were performed in each patient.RESULTS:A total of nine RRD eyes from nine patients who received V4c-ICL implantation were included.The mean time from ICL implantation surgery to the diagnosis of RRD was 32.44±22.56mo(range,1-60mo).At the initial visit for RRD,giant retinal tear(GRT),horseshoe tear,simple round hole,and horseshoe tear combined with round hole were detected in 3,3,2,and 1 eye(s),respectively,with maculaoff in eyes.Eight patients received surgical treatment,and one patient was treated by retinal laser photocoagulation alone.The ICL was preserved in 7 eyes.At the last followup,the mean best corrected visual acuity(BCVA)improved significantly from 1.76±1.06 logMAR at presentation to 0.81±1.01 logMAR(P=0.035),and no case of recurrent retinal detachment was found.CONCLUSION:The morphological presentation of retinal breaks is diverse in this study.The ICL can be preserved in most cases during the course of retinal detachment repair surgery in our data,companied with acceptable visual and anatomical outcomes. 展开更多
关键词 high myopia implantable collamer lens rhegmatogenous retinal detachment
下载PDF
Intraocular lens selection in diabetic patients:How to increase the odds for success
18
作者 Arvind Kumar Morya Prateek Nishant +4 位作者 Prasanna Venkatesh Ramesh Sony Sinha Aarti Heda Sarika Salodia Ripunjay Prasad 《World Journal of Diabetes》 SCIE 2024年第6期1199-1211,共13页
The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract sur... The incidence of cataracts is significantly higher in diabetic individuals,particularly in younger age groups,with rates quadrupled in those under 65 and doubled in those over 65 compared to non-diabetics.Cataract surgery in diabetic patients poses many challenges:Poor epithelial healing,decreased corneal sensitivity,increased central corneal thickness,decreased endothelial cell count,variable topography,poor pupillary dilatation,anterior capsular phimosis,posterior capsular opacification(PCO),chances of progression of diabetic retinopathy(DR),zonular weakness,and vitreous prolapse and diabetic macular edema.Selection of an appropriate intraocular lens(IOL)is crucial for visual rehabilitation and monitoring DR.The choice of IOL in diabetic cataract patients is a challenging scenario.Square-edge IOLs are favored for their capacity to mitigate PCO,whereas hydrophilic counterparts may incur calcification in the setting of proliferative DR.The advisability of premium IOLs for achieving spectacle independence warrants judicious evaluation,particularly in the presence of advanced retinopathy.Optimal IOL placement within the capsular bag is advocated to minimize postoperative complications.Rigorous preoperative assessment and informed patient counseling regarding IOL options are indispensable for optimizing surgical outcomes.This review article covers various aspects regarding the choice of IOLs in different case scenarios and complications in the diabetic population. 展开更多
关键词 DIABETICS CATARACT Intraocular lens Diabetic retinopathy Diabetes mellitus
下载PDF
A holographic optical communication system based on RSA algorithm and quaternion function
19
作者 YANG Peng HAN Jianning 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2024年第3期338-343,共6页
A facile encryption way was successfully applied to the holographic optical encryption system with high speed,multidimensionality,and high capacity,which provided a better security solution for underwater communicatio... A facile encryption way was successfully applied to the holographic optical encryption system with high speed,multidimensionality,and high capacity,which provided a better security solution for underwater communication.The reconstructed optical security system for information transmission was based on wavelengthλand focal length f that were keys to encryption and decryption.To finish the secure data transmission(λ,f)between sender and receiver,an extended Rivest-Shamir-Adleman(ERSA)algorithm for the encryption was achieved based on three-dimension quaternion function.Therein,the Pollard’s rho method was used for the evaluation and comparison of RSA and ERSA algorithms.The results demonstrate that the message encrypted by the ERSA algorithm has better security than that by RSA algorithm in the face of unpredictability and complexity of information transmission on the unsecure acoustic channel. 展开更多
关键词 HOLOGRAPHY QUATERNION Fourier lens extended Rivest-Shamir-Adleman(ERSA) Pollard’s rho method
下载PDF
Effect of capsule treatment on visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataract
20
作者 Wei Liu Qi Liu +2 位作者 Fang Zhou Bo Feng Wan-Ling Wu 《World Journal of Clinical Cases》 SCIE 2024年第19期3882-3889,共8页
BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitre... BACKGROUND Cataracts pose a significant clinical burden due to their complex pathogenesis.In recent years,an increase in cataracts coexisting with myopia has heightened the incidence of retinopathy and posterior vitreous detachment.Additionally,symptoms of ocular axis elongation,lens nucleus hardening,and vitreous liquefaction have become more prevalent.While conventional extracapsular cataract extraction is commonly employed,it often yields suboptimal visual outcomes.Subsequent advancements in cataract phacoemulsification and lens implantation surgeries have gained widespread acceptance for their ability to improve refraction and significantly improve uncorrected visual acuity.AIM To investigate the effect of capsular treatment after phacoemulsification lens implantation in myopic patients with cataract.METHODS We selected 110 patients(with 134 eyes)with myopia and cataracts treated.These patients were categorized into two groups:an observation group(57 patients with 70 eyes)and a control group(53 patients with 64 eyes).The control group underwent cataract phacoemulsification and lens implantation,while the observation group received a refined capsular treatment based on the control group’s procedure.We assessed the differences in visual acuity and quality between the two groups before and after surgery.RESULTS At six months post-operation,the observation group exhibited significantly improved far vision,intermediate vision,near vision,lower objective scattering index,higher Modulation transfer function cut-off frequency,and overall vision metrics at different contrast levels(100%,20%and 9%)compared to the control group(P<0.05).The total score of the National Eye Institute Visual Function Questionnaire in the observation group at 6 months after operation was significantly higher than that in the control group(P<0.05).No significant difference in the incidence of adverse reactions was observed between the observation group and control group(P>0.05).CONCLUSION Capsular treatment demonstrates efficacy in improving visual acuity and quality after phacoemulsification lens implantation in myopic patients with cataracts,warranting its clinical application. 展开更多
关键词 Capsular treatment MYOPIA CATARACT Phacoemulsification and lens implantation Visual acuity Visual quality Uncorrected visual acuity
下载PDF
上一页 1 2 54 下一页 到第
使用帮助 返回顶部