Surface temperature changes of building materials affect the calculation of heat flow and thus the energy use in heating and cooling. The surface heat transfer coefficient , limiting the heat flow between material sur...Surface temperature changes of building materials affect the calculation of heat flow and thus the energy use in heating and cooling. The surface heat transfer coefficient , limiting the heat flow between material surface and ambient air is normally taken as a constant. In this study we propose a time-dependent function . We estimate from unidirectional heat flow experiments with transient and steady-state conditions. Using temperature measurements and the conservation of energy at the surface including convective and irradiative boundary conditions, the value of was obtained both using Finite Difference and Taylor Polynomials methods. Numerical solutions of temperature distribution as function of time were improved with the obtained -functions compared to with constant . There were no clear difference between on different materials, and the final values observed were in the order of magnitude expected from the literature.展开更多
To solve the problems such as high denstiy,foam instability,low compressive strength,high porosity and poor durability associated with conventional foam cements,a novel colloidal gas aphron(CGA)based foam cement syste...To solve the problems such as high denstiy,foam instability,low compressive strength,high porosity and poor durability associated with conventional foam cements,a novel colloidal gas aphron(CGA)based foam cement system was investigated and tested for properties.CGA is used in a base slurry as the foam component and the recipe was optimized with hollow sphere and micro-silica in terms of particle size distribution(PSD).Porosity,permeability,strength,brittleness,elasticity,free water content,foam stability and density tests on the CGA based foam cement system were carried out to evaluate the performance of the system.According to the experiment results,at the foam proportion of 10%,the cement density was reduced to 1040 kg/m3,and stable microfoam net structure not significantly affected by high temperature and high pressure was formed in the cement system.The optimal CGA based foam cement has a free water content of 0%,porosity of 24%,permeability of 0.7×10-3μm2,low elasticity modulus,high Poisson’s ratio,and reasonable compressive strength,and is more elastic and flexible with capability to tolerate regional stresses.展开更多
文摘Surface temperature changes of building materials affect the calculation of heat flow and thus the energy use in heating and cooling. The surface heat transfer coefficient , limiting the heat flow between material surface and ambient air is normally taken as a constant. In this study we propose a time-dependent function . We estimate from unidirectional heat flow experiments with transient and steady-state conditions. Using temperature measurements and the conservation of energy at the surface including convective and irradiative boundary conditions, the value of was obtained both using Finite Difference and Taylor Polynomials methods. Numerical solutions of temperature distribution as function of time were improved with the obtained -functions compared to with constant . There were no clear difference between on different materials, and the final values observed were in the order of magnitude expected from the literature.
文摘To solve the problems such as high denstiy,foam instability,low compressive strength,high porosity and poor durability associated with conventional foam cements,a novel colloidal gas aphron(CGA)based foam cement system was investigated and tested for properties.CGA is used in a base slurry as the foam component and the recipe was optimized with hollow sphere and micro-silica in terms of particle size distribution(PSD).Porosity,permeability,strength,brittleness,elasticity,free water content,foam stability and density tests on the CGA based foam cement system were carried out to evaluate the performance of the system.According to the experiment results,at the foam proportion of 10%,the cement density was reduced to 1040 kg/m3,and stable microfoam net structure not significantly affected by high temperature and high pressure was formed in the cement system.The optimal CGA based foam cement has a free water content of 0%,porosity of 24%,permeability of 0.7×10-3μm2,low elasticity modulus,high Poisson’s ratio,and reasonable compressive strength,and is more elastic and flexible with capability to tolerate regional stresses.