<正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current...<正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current neurochips,such as microelectrode array and field effect transistor array can be settled easily.Based on the theoretical analysis of the interface between cells and LAPS,spontaneously discharges of hippocampal neurons induced by Mg~ 2+)-free media treatment were recorded by LAPS.The results demonstrate that this kind of neurochip has potential to monitor electrophysiology of cultured cells in a non-invasive way.展开更多
The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface fo...The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.30270387,No.30570492)the Project of State Key Laboratory of Transducer Technology of China(Grant No.SKT0403)the Foundation for the Bureau of Zhejiang Province of China(Grant No.20040197).
文摘<正>A novel neurochip based on light addressable potentiometric sensor (LAPS) is designed.Using its light addressable characteristic.The problems of the limitations of restricted discrete active sites of current neurochips,such as microelectrode array and field effect transistor array can be settled easily.Based on the theoretical analysis of the interface between cells and LAPS,spontaneously discharges of hippocampal neurons induced by Mg~ 2+)-free media treatment were recorded by LAPS.The results demonstrate that this kind of neurochip has potential to monitor electrophysiology of cultured cells in a non-invasive way.
基金This work was supported by the National Natural Science Foundation of China (Grant Nos. 30270387, No. 30570492);the Project of State Key Laboratory of Transducer Technology of China (Grant No. SKT0403);the Foundation for the Bureau of Zhejiang Province of China (Grant No. 20040197).
文摘The light-addressable potentiometric sensor (LAPS) is a semiconductor-based cellular biosensor with an electrolyte-insulator-semiconductor (EIS) structure.By depositing biocompatible layers on the sensing surface for cell culture, it can be used to detect bioelectrical parameters of cells.The characteristic curve for photocurrent versus applied bias voltage to the system shows a current-voltage curve (Ⅰ-Ⅴcurve).This technique can be used to detect the action potential changes towards different drugs based on the bias voltage dependence of an optical current,and provides a dynamic system by scanning light beam at the very cell on the sensor device.The LAPS overcomes the limitation of recording sites,but high spatial resolution and sensitivity are also paramount.This paper discussed a novel structure of LAPS array for extracellular monitoring to decrease potential noise level.Both characteristics of active recording array areas and cell culture conditions are measured.
基金supported by the National Natural Science Foundation of China(22034003,21974059,and 22174063)the Excellent Research Program of Nanjing University(ZYJH004)the State Key Laboratory of Analytical Chemistry for Life Science(5431ZZXM2203)。