期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Two annular CsI(Tl) detector arrays for the charged particle telescopes
1
作者 Hong-Yu Zhu Jian-Ling Lou +19 位作者 Yan-Lin Ye Li-Sheng Yang Bo-Long Xia Kang Wei Ying Chen Wei-Liang Pu Zi-Yao Hu Hao-Yu Ge Jia-Hao Chen Kai Ma Wen-Wu Wan Hooi-Jin Ong Yan-Yun Yang Shi-Wei Xu Kang Wang Fang-Fang Duan Jun-Bin Ma Zhen Bai Peng Ma Ruo-Fu Chen 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第10期158-165,共8页
In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a... In this study,we constructed two annular detector arrays comprising 24 wedge-shaped CsI(Tl) crystals,and tested them using anαsource and radioactive beams of ^(14-16) Con a CD_2 target.We compared the properties of a CsI(Tl) crystal encapsulated with various reflectors,revealing that using the 80-μm-thick ESR film to pack the CsI(Tl) crystal yielded the largest light output with the smallest non-uniformity in light output (ΔLO).For the 24 CsI(Tl) detectors with the 80-μm-thick ESR films,the average energy resolution improved as the average light output increased;however,it deteriorated as theΔLO value increased.To form two annular Si-CsI(Tl) telescopes for identifying the light-charged particles,theΔLO value and energy resolution of each CsI(Tl) detector were maintained under 20%and 7.7%,respectively.These telescopes were tested for the first time in a direct nuclear reaction experiment using ^(14-16) C+d.The results demonstrated that the Z=1 and Z=2 charged particles were adequately discriminated by the telescopes using the standardΔE-E method. 展开更多
关键词 Wedge-shaped CsI(Tl)detector Light output non-uniformity Si-CsI(Tl)telescope Particle identification
下载PDF
Measurements of the light output functions of plastic scintillator using ~9Be(d,n)^(10)B reaction neutron source 被引量:2
2
作者 张建福 阮锡超 +5 位作者 侯龙 李霞 鲍杰 张国光 黄翰雄 宋朝红 《Chinese Physics C》 SCIE CAS CSCD 2010年第7期988-992,共5页
The light output functions for protons of ST-401 and BC-408 plastic scintillators were measured using white neutron source produced by the 9Be(d,n) 10B reaction at the HI-13 Tandem Accelerator at China Institute of ... The light output functions for protons of ST-401 and BC-408 plastic scintillators were measured using white neutron source produced by the 9Be(d,n) 10B reaction at the HI-13 Tandem Accelerator at China Institute of Atomic Energy(CIAE).The LOFs of plastic scintillators for protons in the energy range of 0.5-16.5 MeV were obtained by the time-of-flight(TOF) technique and an iterative procedure.Two parameters(kB and C) were deduced by fitting the experimental data. 展开更多
关键词 plastic scintillator light output function 9Be(d n) 10B reaction ST-401 BC-408
原文传递
Study of the characteristics of a scintillation array and single pixels for nuclear medicine imaging applications 被引量:2
3
作者 祝杰 马红光 +3 位作者 马文彦 曾晖 汪兆民 许咨宗 《Chinese Physics C》 SCIE CAS CSCD 2009年第4期285-288,共4页
By using a pixelized Nal(T1) crystal array coupled to a R2486 PSPMT, the characteristics of the array and of a single pixel, such as the light output, energy resolution, peak-to-valley ratio (P/V) and imaging perf... By using a pixelized Nal(T1) crystal array coupled to a R2486 PSPMT, the characteristics of the array and of a single pixel, such as the light output, energy resolution, peak-to-valley ratio (P/V) and imaging performance of the detector were studied. The pixel size of the NaI(TI) scintillation pixel array is 2 mm×2 mm×5 mm. There are in total 484 pixels in a 22×22 matrix. In the pixel spectrum an average peak-to-valley ratio (P/V) of 16 was obtained. In the image of all the pixels, good values for the Peak-to- Valley ratios could be achieved, namely a mean of 17, a maximum of 45 and the average peak FWHM (the average value of intrinsic spatial resolution) of 2.3 mm. However, the PSPMT non-uniform response and the scintillation pixels array inhomogeneities degrade the imaging performance of the detector. 展开更多
关键词 CHARACTERISTICS scintillation pixels array light output peak-to-valley ratio
原文传递
Increased effective reflection and transmission at the GaN-sapphire interface of LEDs grown on patterned sapphire substrates
4
作者 吴冬雪 马平 +3 位作者 刘波亭 张烁 王军喜 李晋闽 《Journal of Semiconductors》 EI CAS CSCD 2016年第10期60-64,共5页
The effect of patterned sapphire substrate(PSS) on the top-surface(P-Ga N-surface) and the bottomsurface(sapphire-surface) of the light output power(LOP) of Ga N-based LEDs was investigated, in order to study ... The effect of patterned sapphire substrate(PSS) on the top-surface(P-Ga N-surface) and the bottomsurface(sapphire-surface) of the light output power(LOP) of Ga N-based LEDs was investigated, in order to study the changes in reflection and transmission of the Ga N-sapphire interface. Experimental research and computer simulations were combined to reveal a great enhancement in LOP from either the top or bottom surface of Ga N-based LEDs, which are prepared on patterned sapphire substrates(PSS-LEDs). Furthermore, the results were compared to those of the conventional LEDs prepared on the planar sapphire substrates(CSS-LEDs). A detailed theoretical analysis was also presented to further support the explanation for the increase in both the effective reflection and transmission of PSS-Ga N interface layers and to explain the causes of increased LOP values. Moreover, the bottom-surface of the PSS-LED chip shows slightly increased light output performance when compared to that of the top-surface. Therefore, the light extraction efficiency(LEE) can be further enhanced by integrating the method of PSS and flip-chip structure design. 展开更多
关键词 light output power transmission effective reflection patterned sapphire substrate light-emitting diodes
原文传递
Testing and analysis of the plastic scintillator units for LHAASO-ED
5
作者 Ya-Ping Wang Chao Hou +6 位作者 Xiang-Dong Sheng Shao-Hui Feng Hong-Kui Lv Jia Liu Jing Zhao Xiao-Peng Zhang Quan-Bu Gou 《Radiation Detection Technology and Methods》 CSCD 2021年第4期513-519,共7页
Background A total of 5195 electromagnetic particle detectors(EDs)are used in the 1-square-kilometer extensive air shower array(KM2A),which is a subarray of the Large High Altitude Air Shower Observatory(LHAASO).Purpo... Background A total of 5195 electromagnetic particle detectors(EDs)are used in the 1-square-kilometer extensive air shower array(KM2A),which is a subarray of the Large High Altitude Air Shower Observatory(LHAASO).Purpose As the detection sensitive medium of the EDs,more than 20,000 plastic scintillator units(BC-408),produced by Saint-Gobain,are used in LHAASO.It is important to monitor the light output of the scintillator units among the units.Method To improve the efficiency,a sampling inspection scheme(misjudgment rate of less than 5%)was designed,and a batch test system was developed.Ten units of scintillator units can be measured at a time.The test system selects the single muon events of cosmic rays to measure the light output values of the plastic scintillator units.Results The measurement has an uncertainty of less than 2%.By pretest calibration,the difference between different channels can be eliminated.The calibration was implemented approximately every 3 months,and the test system had been running stably for 28 months.By measuring the ratio of the signals of selected far and near probe events,the changes in the quality of different batches of plastic scintillator units can be demonstrated.Conclusions The test system realized accurate measurement of the light output,and all batches satisfied the requirements of the experiment. 展开更多
关键词 LHAASO ED Plastic scintillator unit Light output
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部