The lightning current magnitude and other characteristics are important basic data of the lightning disaster investigation and identification. The characteristics of lightning monitoring and positioning system in Inne...The lightning current magnitude and other characteristics are important basic data of the lightning disaster investigation and identification. The characteristics of lightning monitoring and positioning system in Inner Mongolia were introduced and studied in the lightning accident analysis based on the lightning monitoring and positioning data of the lightning stroke accidents. The positioning error of lightning monitoring and positioning system was analyzed. The results showed that lightning current intensity and the position precision were very important data in the lightning disaster investigation. Finally, a variety of meteorological data should be applied in the lightning disaster investigation and identification.展开更多
Analytic method and identification direction for rational identification of lightning derivative disasters by strong convective weather monitoring data in southern China were introduced. Taking identification cases of...Analytic method and identification direction for rational identification of lightning derivative disasters by strong convective weather monitoring data in southern China were introduced. Taking identification cases of lightning disaster in Guangzhou Development Region as the background,according to the characteristics in the region that large high-precision enterprises were more,lightning derivative disasters occurred frequently in thunderstorm season,and the actual situation that time of the affected enterprise applying for lightning disaster scene identification lagged,combining Technical Specifications of Lightning Disaster Investigation( QX / T103-2009),qualitative analysis method of lightning derivative disaster was put forward under the weather condition of strong convection in southern China by using weather monitoring data( Doppler sounding radar data,lightning positioning monitoring data,atmospheric electric field data,rainfall data,wind direction and force),and was optimized by technical means( " metallographic method" and " remanence law"). The research could put forward efficient and convenient analytical thinking and method for lightning derivative disaster,and further optimize accuracy and credibility of lightning disaster investigation.展开更多
Regional lightning protection is a complete theoretical system,mainly including:lightning interception technology(LIPT),lightning strong electromagnetic pulse high-energy absorption technology(MSPD),and regional light...Regional lightning protection is a complete theoretical system,mainly including:lightning interception technology(LIPT),lightning strong electromagnetic pulse high-energy absorption technology(MSPD),and regional lightning activity law analysis technology(RLLA).Lightning interception technology uses dispersive waveguide resonant cavity technology to achieve the functions of 46.55 m longer than upward leader of ordinary lightning rod,significantly reducing lightning strike point current by 40%,optimizing space electromagnetic field environment,and effectively intercepting overhead and side lightning strikes,and overcome the limitations of traditional lightning rod.The lightning strong electromagnetic pulse high-energy absorption technology uses distributed parameter balance technology,special disconnector for short circuit current,and parity pairing technology to achieve stronger surge absorption capacity than traditional single pulse SPD and international advanced technical indicators such as timely breaking under power frequency short circuit current,and good energy and time coordination.The analysis technology of regional lightning activity laws accurately identifies lightning strike points through comprehensive analysis of regional lightning activity laws,physical parameters of ion clouds,and the impact on ground electric fields.The three core technology systems complement each other,achieving all-round protection against direct lightning strike and lightning electromagnetic pulse.Several projects achieved zero lightning damage,effectively ensuring the safety of buildings and electronic and electrical equipment in the protected area.展开更多
基金Supported by Science and Technology Project of Lightning Warning&Protection Center in Inner Mongolia,China(nmldkjcx201301)
文摘The lightning current magnitude and other characteristics are important basic data of the lightning disaster investigation and identification. The characteristics of lightning monitoring and positioning system in Inner Mongolia were introduced and studied in the lightning accident analysis based on the lightning monitoring and positioning data of the lightning stroke accidents. The positioning error of lightning monitoring and positioning system was analyzed. The results showed that lightning current intensity and the position precision were very important data in the lightning disaster investigation. Finally, a variety of meteorological data should be applied in the lightning disaster investigation and identification.
文摘Analytic method and identification direction for rational identification of lightning derivative disasters by strong convective weather monitoring data in southern China were introduced. Taking identification cases of lightning disaster in Guangzhou Development Region as the background,according to the characteristics in the region that large high-precision enterprises were more,lightning derivative disasters occurred frequently in thunderstorm season,and the actual situation that time of the affected enterprise applying for lightning disaster scene identification lagged,combining Technical Specifications of Lightning Disaster Investigation( QX / T103-2009),qualitative analysis method of lightning derivative disaster was put forward under the weather condition of strong convection in southern China by using weather monitoring data( Doppler sounding radar data,lightning positioning monitoring data,atmospheric electric field data,rainfall data,wind direction and force),and was optimized by technical means( " metallographic method" and " remanence law"). The research could put forward efficient and convenient analytical thinking and method for lightning derivative disaster,and further optimize accuracy and credibility of lightning disaster investigation.
基金Supported by Lightning Multi-pulse Intelligent Monitoring System Optimization Technology Project of Guangdong Yuedian Dianbai Hot Water Wind Farm(SFC/DBW-Z-FW-23-006).
文摘Regional lightning protection is a complete theoretical system,mainly including:lightning interception technology(LIPT),lightning strong electromagnetic pulse high-energy absorption technology(MSPD),and regional lightning activity law analysis technology(RLLA).Lightning interception technology uses dispersive waveguide resonant cavity technology to achieve the functions of 46.55 m longer than upward leader of ordinary lightning rod,significantly reducing lightning strike point current by 40%,optimizing space electromagnetic field environment,and effectively intercepting overhead and side lightning strikes,and overcome the limitations of traditional lightning rod.The lightning strong electromagnetic pulse high-energy absorption technology uses distributed parameter balance technology,special disconnector for short circuit current,and parity pairing technology to achieve stronger surge absorption capacity than traditional single pulse SPD and international advanced technical indicators such as timely breaking under power frequency short circuit current,and good energy and time coordination.The analysis technology of regional lightning activity laws accurately identifies lightning strike points through comprehensive analysis of regional lightning activity laws,physical parameters of ion clouds,and the impact on ground electric fields.The three core technology systems complement each other,achieving all-round protection against direct lightning strike and lightning electromagnetic pulse.Several projects achieved zero lightning damage,effectively ensuring the safety of buildings and electronic and electrical equipment in the protected area.