In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave th...In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.展开更多
Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the b...Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the basis of lightning flashover risk evaluation methodology for transmission lines, and adopts the improved Analytic Hierarchy Process as the core algorithm. It can comprehensively evaluate the risk for transmission lines of regional grid, various sections of a line and each tower of the section, considering much more impact factors, including the running time of line, importance of grades, equipment damage, and the success rate of lightning stroke reclosing and so on. According to the calculation results of the risk assessment of the analytic hierarchy process and lightning flashover risk evaluation, the principles and methods of grade classification for power grid lightning damage risk map are studied, and give typical examples in the paper. It can describe the lightning withstanding ability much more scientifically and provide important references for the manage department of power system.展开更多
During the pre-summer rainy season,heavy rainfall occurs frequently in South China.Based on polarimetric radar observations,the microphysical characteristics and processes of convective features associated with extrem...During the pre-summer rainy season,heavy rainfall occurs frequently in South China.Based on polarimetric radar observations,the microphysical characteristics and processes of convective features associated with extreme rainfall rates(ERCFs)are examined.In the regions with high ERCF occurrence frequency,sub-regional differences are found in the lightning flash rate(LFR)distributions.In the region with higher LFRs,the ERCFs have larger volumes of high reflectivity factor above the freezing level,corresponding to more active riming processes.In addition,these ERCFs are more organized and display larger spatial coverage,which may be related to the stronger low-level wind shear and higher terrain in the region.In the region with lower LFRs,the ERCFs have lower echo tops and lower-echo centroids.However,no clear differences of the most unstable convective available potential energy(MUCAPE)exist in the ERCFs in the regions with different LFR characteristics.Regardless of the LFRs,raindrop collisional coalescence is the main process for the growth of raindrops in the ERCFs.In the ERCFs within the region with lower LFRs,the main mechanism for the rapid increase of liquid water content with decreasing altitude below 4 km is through the warm-rain processes converting cloud drops to raindrops.However,in those with higher LFRs,the liquid water content generally decreases with decreasing altitude.展开更多
The rate of neutralized charge by lightning(RNCL) is an important parameter indicating the intensity of lightning activity.The total charging rate(CR),the CR of one kind of polarity(e.g.,negative) charge(CROP)...The rate of neutralized charge by lightning(RNCL) is an important parameter indicating the intensity of lightning activity.The total charging rate(CR),the CR of one kind of polarity(e.g.,negative) charge(CROP),and the outflow rate of charge on precipitation(ORCP) are proposed as key factors impacting RNCL,based on the principle of conservation of one kind of polarity charge in a thunderstorm.In this paper,the impacts of updraft on CR and CROP are analyzed by using a 3D cloud resolution model for a strong storm that occurred in Beijing on 6 September 2008.The results show that updraft both promotes and inhibits RNCL at the same time.(1) Updraft always has a positive influence on CR.The correlation coefficient between the updraft volume and CR can reach 0.96.Strengthening of the updraft facilitates strengthening of RNCL through this positive influence.(2) Strengthening of the updraft also promotes reinforcement of CROP.The correlation coefficient between the updraft volume and CROP is high(about0.9),but this promotion restrains the strengthening of RNCL because the strengthening of CROP will,most of the time,inhibit the increasing of RNCL.(3) Additionally,increasing of ORCP depresses the strengthening of RNCL.In terms of magnitude,the peak of ORCP is equal to the peak of CR.Because precipitation mainly appears after the lightning activity finishes,the depression effect of ORCP on RNCL can be ignored during the active lightning period.展开更多
We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the m...We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the month-to-month variation characteristic of PLR occurrence rate observed by satellite and its several influencing factors,including solar radiation,lightning activity,and try to clarify the influence of electricity consumption.The results show that the solar radiation(solar zenith angle and F10.7)plays a major role in the variation of the PLR occurrence rate,and that there is no direct connection with the number of lightning.For the relationship between PLR occurrence rate and electricity consumption,the low occurrence rate associated with decreased weekend electricity consumption was not observed in the US.However,there is a significant difference in PLR occurrence rate between the East and West Coasts of the US at the same latitude during the same time period,suggesting that the significant difference in PLR occurrence rate is caused by the significant difference in electricity consumption between the two coasts.After excluding the effect of solar radiation on PLR occurrence rate,we concluded that only a significant difference in regional electricity consumption could lead to a corresponding change in PLR occurrence rate detected by the Low-Earth-Orbit satellite.Finally,we also found there is seasonal variation in the diurnal differences of the PLR occurrence rate caused by seasonal variation of the lower ionosphere.展开更多
文摘In recent years,several failures of double circuit transmission line on the same tower due to lightning were happened in Beijing power grid.Although it can be reclosed successful,the lightning strike caused a grave threat to the power grid security.The cause of the accident and the accident process were studied for the sake of further understanding of the impact of lightning on power grid.As an example,110 kV double circuit transmission line(Xilong-line) was analyzed.At first,the system topology was given.Through the analysis on relay protection actions and the fault recorder data,over voltage on the insulator strings was calculated.Based on the analysis and the calculation,accident cause and the process were presented respectively.Secondly,it comes to the conclusion that the lightning failure was caused by counterattack.The wave of the lightning over voltage would spread to the not grounded neutral point of the transformers,and make the neutral protective gap breakdown,then cause freewheeling with the frequency of 50 Hz.As results of the relay protection,the double circuit transmission line all tripped out.Finally,the causes of the accident were proposed that included terrain features,large corner towers,strong thunderstorm weather and poor grounded contact of the tower.
文摘Based on the idea of risk evaluation, the existing lightning damage risk assessment methods are reviewed and summarized in this paper. And the power grid lightning damage risk assessment system is established on the basis of lightning flashover risk evaluation methodology for transmission lines, and adopts the improved Analytic Hierarchy Process as the core algorithm. It can comprehensively evaluate the risk for transmission lines of regional grid, various sections of a line and each tower of the section, considering much more impact factors, including the running time of line, importance of grades, equipment damage, and the success rate of lightning stroke reclosing and so on. According to the calculation results of the risk assessment of the analytic hierarchy process and lightning flashover risk evaluation, the principles and methods of grade classification for power grid lightning damage risk map are studied, and give typical examples in the paper. It can describe the lightning withstanding ability much more scientifically and provide important references for the manage department of power system.
基金primarily supported by the National Natural Science Foundation of China(Grant Nos.42025501,41905019,and 61827901)the National Key Research and Development Program of China(Grant 2018YFC1506404 and Grant 2017YFC1501703)。
文摘During the pre-summer rainy season,heavy rainfall occurs frequently in South China.Based on polarimetric radar observations,the microphysical characteristics and processes of convective features associated with extreme rainfall rates(ERCFs)are examined.In the regions with high ERCF occurrence frequency,sub-regional differences are found in the lightning flash rate(LFR)distributions.In the region with higher LFRs,the ERCFs have larger volumes of high reflectivity factor above the freezing level,corresponding to more active riming processes.In addition,these ERCFs are more organized and display larger spatial coverage,which may be related to the stronger low-level wind shear and higher terrain in the region.In the region with lower LFRs,the ERCFs have lower echo tops and lower-echo centroids.However,no clear differences of the most unstable convective available potential energy(MUCAPE)exist in the ERCFs in the regions with different LFR characteristics.Regardless of the LFRs,raindrop collisional coalescence is the main process for the growth of raindrops in the ERCFs.In the ERCFs within the region with lower LFRs,the main mechanism for the rapid increase of liquid water content with decreasing altitude below 4 km is through the warm-rain processes converting cloud drops to raindrops.However,in those with higher LFRs,the liquid water content generally decreases with decreasing altitude.
基金Supported by the National Natural Science Foundation of China(41205001)National(Key)Basic Research and Development(973)Program of China(2014CB441406)+1 种基金National Major Scientific Instruments and Equipment Development Special(61327810)Basic Research Funds of CAMS(2012Y005 and 2013Z006)
文摘The rate of neutralized charge by lightning(RNCL) is an important parameter indicating the intensity of lightning activity.The total charging rate(CR),the CR of one kind of polarity(e.g.,negative) charge(CROP),and the outflow rate of charge on precipitation(ORCP) are proposed as key factors impacting RNCL,based on the principle of conservation of one kind of polarity charge in a thunderstorm.In this paper,the impacts of updraft on CR and CROP are analyzed by using a 3D cloud resolution model for a strong storm that occurred in Beijing on 6 September 2008.The results show that updraft both promotes and inhibits RNCL at the same time.(1) Updraft always has a positive influence on CR.The correlation coefficient between the updraft volume and CR can reach 0.96.Strengthening of the updraft facilitates strengthening of RNCL through this positive influence.(2) Strengthening of the updraft also promotes reinforcement of CROP.The correlation coefficient between the updraft volume and CROP is high(about0.9),but this promotion restrains the strengthening of RNCL because the strengthening of CROP will,most of the time,inhibit the increasing of RNCL.(3) Additionally,increasing of ORCP depresses the strengthening of RNCL.In terms of magnitude,the peak of ORCP is equal to the peak of CR.Because precipitation mainly appears after the lightning activity finishes,the depression effect of ORCP on RNCL can be ignored during the active lightning period.
基金supported by the Specialized Research Fund for State Key Laboratories,National Space Science Center,Chinese Academy of Sciences,Talent startup research grants from National Space Science Center,Chinese Academy of Sciences(Grant Nos.2023000034,E3RC2TQ4,and E3RC2TQ5)the National Natural Science Foundation of China(Grant No.41704156)+2 种基金the China Research Institute of Radiowave Propagation(Research on low ionosphere satellite detection)a project funded by China National Space Administration(CNSA)the China Earthquake Administration(CEA)。
文摘We analyze the topside ionosphere power line radiation(PLR)at 60 Hz over the US using electric field data collected by CSES satellite between January 2019 and December 2022.The study aimed to further investigate the month-to-month variation characteristic of PLR occurrence rate observed by satellite and its several influencing factors,including solar radiation,lightning activity,and try to clarify the influence of electricity consumption.The results show that the solar radiation(solar zenith angle and F10.7)plays a major role in the variation of the PLR occurrence rate,and that there is no direct connection with the number of lightning.For the relationship between PLR occurrence rate and electricity consumption,the low occurrence rate associated with decreased weekend electricity consumption was not observed in the US.However,there is a significant difference in PLR occurrence rate between the East and West Coasts of the US at the same latitude during the same time period,suggesting that the significant difference in PLR occurrence rate is caused by the significant difference in electricity consumption between the two coasts.After excluding the effect of solar radiation on PLR occurrence rate,we concluded that only a significant difference in regional electricity consumption could lead to a corresponding change in PLR occurrence rate detected by the Low-Earth-Orbit satellite.Finally,we also found there is seasonal variation in the diurnal differences of the PLR occurrence rate caused by seasonal variation of the lower ionosphere.