Due to its significant attributes,the liquid metal current limiter(LMCL)is considered a new strategy for limiting short-circuit current in the power grid.A resistive wall liquid metal current limiter(RWLMCL)is designe...Due to its significant attributes,the liquid metal current limiter(LMCL)is considered a new strategy for limiting short-circuit current in the power grid.A resistive wall liquid metal current limiter(RWLMCL)is designed to advance the starting current-limiting time.Experiments are performed to investigate the dynamic behaviors of liquid metal,and the influence of different currents on the liquid metal self-shrinkage effect is compared and analyzed.Furthermore,the liquid metal self-shrinkage effect is mathematically modeled,and the reason for the formation of arc plasma is obtained by simulation.The laws of arc plasma formation and the current transfer in the cavity are revealed,and the motion mechanisms are explained by physical principles.The simulations are in accordance with the test data.It is demonstrated that the sudden change of the current density at both ends of the wall causes the liquid metal to shrink and depress under the electromagnetic force,and the current starts to transfer from the liquid metal path to the wall resistance path.The RWLMCL can effectively advance the starting current-limiting time.展开更多
A high-voltage transverse pulsed nanosecond discharge with a slotted hollow cathode was found to be a source of high-energy (few kV) ribbon electron beams. Conditions for the formation and extinction of electron bea...A high-voltage transverse pulsed nanosecond discharge with a slotted hollow cathode was found to be a source of high-energy (few kV) ribbon electron beams. Conditions for the formation and extinction of electron beams were experimentally studied in discharges in helium at pressures of 1-100 Torr. It was found that interaction of fast electrons with a non-uniform electric field near the slotted cathode led to limitation of the magnitude of the discharge current. A physical model was developed to describe the discharge current self-limitation that was in satisfactory agreement with the experimental results. Some technical solutions that are expected to increase the upper current limits in transverse nanosecond discharge are discussed.展开更多
The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations.However,this is quite challenging because of the heavy weight of the scintillator and s...The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations.However,this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors.The weight and thickness of X-ray detectors can be reduced by replacing the silicon layer with an organic photodetectors.This study presents a novel bithienopyrroledione-based polymer donor that exhibits excellent photodetection properties even in a thick photoactive layer(~700 nm),owing to the symmetric backbone and highly soluble molecular structure of bithienopyrroledione.The ability of bithienopyrroledione-based polymer donor to strongly suppress the dark current density(Jd~10−10 A cm^(−2))at a negative bias(−2.0 V)while maintaining high responsivity(R=0.29 A W−1)even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of D_(sh)^(*)=2.18×10^(13)Jones in the organic photodetectors.Printed organic photodetectors are developed by slot-die coating for use in X-ray detectors,which exhibit D_(sh)^(*)=2.73×10^(12)Jones with clear rising(0.26 s)and falling(0.29 s)response times upon X-ray irradiation.Detection reliability is also proven by linear response of the X-ray detector,and the X-ray detection limit is 3 mA.展开更多
The GaInSn liquid metal current limiter based on the fluid pinch effect has broad application prospects due to its particular properties. However, the limited rated current and abil- ity of power dissipation are the c...The GaInSn liquid metal current limiter based on the fluid pinch effect has broad application prospects due to its particular properties. However, the limited rated current and abil- ity of power dissipation are the critical problems for its wide application. Firstly, the temperature distribution of the liquid metal current limiter (LMCL) was obtained by experiments with a rated current of 1 kA and the arc ignition phenomenon was observed with 1.5 kA, which indicates that the rated current is mainly limited by the arc rather than the high temperature compared to the traditional switchgears. Furthermore, an improved method is proposed by adding the paralleled pure resistance, impedance or another LMCL element to protect the setup from the fault energy concentration in the setup. The problem of a slower arc voltage increasing rate can be solved by adding a paralleled impedance with suitable parameters. Finally, the current limiting properties based on the improved method were investigated and the alternating oscillating current was found between two paralleled LMCL elements owing to their deviation of arc ignition in reality.展开更多
The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer ...The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer exists at the junction of a bipolar membrane, which is coincided with the viewpoint of the most literatures, but we also consider that the thickness and conductivity of this layer is not only related with the increase of the applied voltage but also with the limiting current density. Below the limiting current density, the thickness of the depletion layer keeps a constant and the conductivity decreases with the increase of the applied voltage; while above the limiting current density, the depletion thickness will increase with the increase of the applied voltage and the conductivity keeps a very low constant. Based on the data reported in the literatures and independent determinations, the limiting current density was calculated and the experimental curves Ⅰ-Ⅴ in the two directions were com展开更多
This paper presents a new type of fault current limiter (FCL) based on fast closing switch, which is composed of a capacitor bank and a reactor in series. The main control component is a fast closing switch connecte...This paper presents a new type of fault current limiter (FCL) based on fast closing switch, which is composed of a capacitor bank and a reactor in series. The main control component is a fast closing switch connected in parallel with the capacitors, which is driven by the electromagnetic repulsion force. It can response the order within 1 ms. When fault occurs, the switch closes and the capacitors are bypassed, and the fault current is limited by the reactor. Simulation analysis and experiment show that the electromagnetic repulsion force actuator can meet the demand of fast closing switch, it is feasible to develop the FCL with low cost and high reliability.展开更多
The liquid metal current limiter(LMCL)is regarded as a viable solution for reducing the fault current in a power grid.But demonstrating the liquid metal arc plasma self-pinching process of the resistive wall,and reduc...The liquid metal current limiter(LMCL)is regarded as a viable solution for reducing the fault current in a power grid.But demonstrating the liquid metal arc plasma self-pinching process of the resistive wall,and reducing the erosion of the LMCL are challenging,not only theoretically,but also practically.In this work,a novel LMCL is designed with a resistive wall that can be connected to the current-limiting circuit inside the cavity.Specifically,a novel fault current limiter(FCL)topology is put forward where the novel LMCL is combined with a fast switch and current-limiting reactor.Further,the liquid metal self-pinch effect is modeled mathematically in three dimensions,and the gas-liquid two-phase dynamic diagrams under different short-circuit currents are obtained by simulation.The simulation results indicate that with the increase of current,the time for the liquid metal-free surface to begin depressing is reduced,and the position of the depression also changes.Different kinds of bubbles formed by the depressions gradually extend,squeeze,and break.With the increase of current,the liquid metal takes less time to break,but breaks still occur at the edge of the channel,forming arc plasma.Finally,relevant experiments are conducted for the novel FCL topology.The arcing process and current transfer process are analyzed in particular.Comparisons of the peak arc voltage,arcing time,current limiting efficiency,and electrode erosion are presented.The results demonstrate that the arc voltage of the novel FCL topology is reduced by more than 4.5times and the arcing time is reduced by more than 12%.The erosions of the liquid metal and electrodes are reduced.Moreover,the current limiting efficiency of the novel FCL topology is improved by 1%–5%.This work lays a foundation for the topology and optimal design of the LMCL.展开更多
Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC g...Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.展开更多
In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations ...In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations of limit current density, voltage drop of the unit membrane pair at the limiting current and desalination ratio at the limiting current were obtained.展开更多
A two-dimensional solution of space-charge-limiting current for a high current vacuum diode with a spherical cathode is presented. The relation between space-charge-limiting current and electric field enhancement fact...A two-dimensional solution of space-charge-limiting current for a high current vacuum diode with a spherical cathode is presented. The relation between space-charge-limiting current and electric field enhancement factor at the cathode surface for the diode with a curved surface cathode is also discussed. It is shown that compared with the current given by the conventional Child-Langmuir law, which describes the one-dimensional space-charege-limiting current, the two-dimensional space-charge-limiting current in such a diode is enhanced due to the electric-field enhancement along the cathode surface. Among practical parameter ranges, enhancement factor ηb approximately satisfies ηb Aβn, where β is the electric field enhancement factor at the cathode surface, and n is a constant between 1 and 2, which is confirmed to be universal for the diodes with curved surface cathodes.展开更多
The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial...The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization.展开更多
The self-consistent differential equations, which describe a laminar-flow equilibrium state in a magnetically focused intense relativistic electron beam propagating inside a conducting waveguide, are presented. The ca...The self-consistent differential equations, which describe a laminar-flow equilibrium state in a magnetically focused intense relativistic electron beam propagating inside a conducting waveguide, are presented. The canonical angular momentum, Pe, defined under the conditions at the source, uniquely determines the possible solutions of these equations. By numerically solving these equations, the space-charge limited current and the externally applied magnetic field are obtained in a solid beam and a hollow beam in two cases of Pθ= 0 (magnetically shielded source) and Pθ= const. (immersed source) separately. It is shown that the hollow beam is more beneficial to the propagation of the intense relativistic beam through a drift tube than the solid beam.展开更多
A new type of fault current limiter (FCL) with series compensation based fast-closing switch is proposed. It is composed of a capacitor bank and a reactor in series. The main control component is a fast-closing switch...A new type of fault current limiter (FCL) with series compensation based fast-closing switch is proposed. It is composed of a capacitor bank and a reactor in series. The main control component is a fast-closing switch connected in parallel with the capacitors, which is driven by the electromagnetic repulsion force. When fault occurs, the switch closes and bypasses the capacitors, and the fault is limited by the reactor then. Simulated analysis and experiments show that it is feasible to develop the FCL with low cost and high reliability. The effectiveness of transient stability for power system is evaluated by digital simulation.展开更多
Rotating disk electrode systems are widely used to study the kinetics of electrocatalytic reactions that may suffer from insufficient mass transfer of the reactants.Kinetic current density at certain overpotential cal...Rotating disk electrode systems are widely used to study the kinetics of electrocatalytic reactions that may suffer from insufficient mass transfer of the reactants.Kinetic current density at certain overpotential calculated by the Koutecky-Levich equation is commonly used as the metrics to evaluate the activity of electrocatalysts.However,it is frequently found that the diffusion limiting current density is not correctly identified in the literatures.Instead of kinetic current density,the measured current density normalized by diffusion limiting current density(j/jL)has also been frequently under circumstance where its validity is not justified.By taking oxygen reduction reaction/hydrogen oxidation reaction/hydrogen evolution reaction as examples,we demonstrate that identifying the actual diffusion limiting current density for the same reaction under otherwise identical conditions from the experimental data is essential to accurately deduce kinetic current density.Our analysis reveals that j/jLis a rough activity metric which can only be used to qualitatively compare the activity trend under conditions that the mass transfer conditions and the roughness factor of the electrode are exactly the same.In addition,if one wants to use j/jLto compare the intrinsic activity,the concentration overpotential should be eliminated.展开更多
This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems...This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems. In particular, a strategy, based on SCR (silicon controlled rectifier) phase, shift control in a mixed rectifier bridge with diodes and thyristors, is proposed. The challenge is to help designers optimize the triggering delay of SCRs to both limit the peak value of inrush current spikes and optimize the charge duration of the DC-link capacitor. A mathematical model (Mathcad engineering tool) has been defined to point out, the interest of a variable triggering delay to control SCRs to meet the expectations described previously. Experimental measurements using an industrial evaluation board of the AC-DC converter demonstrate the robustness of the method.展开更多
Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) int...Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) into an existing distribution network not only inevitably increases fault current levels to levels that may exceed the OCR ratings, but it may also disturb the original overcurrent relay coordination adversely effecting protection selectivity. To analyze the potentially adverse impact of DG on distribution system protective devices with respect to circuit breaker ratings and OCR coordination fault current studies are carried out for common reference test system under the influence of additional DG. The possible advantages of Superconducting Fault Current Limiter (SFCL) as a means to limit the adverse effect of DG on distribution system protection and their effectiveness will be demonstrated. Furthermore, minimum SFCL impedances required to avoid miss-operation of the primary and back-up OCRs are determined. The theoretical analysis will be validated using the IEEE 13-bus distribution test system is used. Both theoretical and simulation results indicate that the proposed application of SFCL is a viable option to effectively mitigate the DG impact on protective devices, thus enhancing the reliability of distribution network interfaced with DG.展开更多
The effectiveness of a combination of fault current limiter and thyristor controlled braking resistor on power system stability enhancement and damping turbine shaft torsional oscillations has been studied. If both de...The effectiveness of a combination of fault current limiter and thyristor controlled braking resistor on power system stability enhancement and damping turbine shaft torsional oscillations has been studied. If both devices operate at the same bus, the stabilization control scheme can be carried out continuously and with flexibility. As a result, the fault currents are limited, and the generator disturbances and the turbine shaft torsional oscillations are converged quickly. In this paper, the effectiveness of the combination of both devices has been demonstrated by considering 3LG (three-lines-to-ground) fault in a two-machine infinite bus system. Also, temperature rise effect of both devices with various resistance values and weights has been demonstrated. Simulation results indicate a significant power system stability enhancement and damping turbine shaft torsional oscillations as well as with allowable temperature rise.展开更多
Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC cur...Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.展开更多
The avoidance of runaway electrons(REs) generated during plasma disruption is of great concern for the safe operation of tokamak devices.Experimental study on the suppression of runaway current by electrode biasing(EB...The avoidance of runaway electrons(REs) generated during plasma disruption is of great concern for the safe operation of tokamak devices.Experimental study on the suppression of runaway current by electrode biasing(EB) and limiter biasing(LB) has been performed on the J-TEXT tokamak,which could be an alternative way to suppress the runaway current.The experimental results show that the higher the voltage value,the smaller the runaway current in both EB and LB experiments.The runaway current can be completely suppressed at an electrode biased voltage of +450 V and a limiter biased voltage of +300 V.The comparison of the energy spectra during the runaway plateau phase shows that the maximum energy max(E_(RE)) and radiation temperature T_(HXR)hard x-rays(HXRs)are significantly reduced after the application of +200 V limiter biased voltage.The electric field generated by the biased voltage may be the key factor to suppress the runaway current,and the measured radial electric field increases obviously after the voltage is applied.This may result in an increase in the loss of REs to realize the suppression of runaway current.展开更多
基金supported by National Natural Science Foundation of China(No.52177131)the Interdisciplinary Program of Wuhan National High Magnetic Field Center(No.WHMFC202130)Huazhong University of Science and Technology。
文摘Due to its significant attributes,the liquid metal current limiter(LMCL)is considered a new strategy for limiting short-circuit current in the power grid.A resistive wall liquid metal current limiter(RWLMCL)is designed to advance the starting current-limiting time.Experiments are performed to investigate the dynamic behaviors of liquid metal,and the influence of different currents on the liquid metal self-shrinkage effect is compared and analyzed.Furthermore,the liquid metal self-shrinkage effect is mathematically modeled,and the reason for the formation of arc plasma is obtained by simulation.The laws of arc plasma formation and the current transfer in the cavity are revealed,and the motion mechanisms are explained by physical principles.The simulations are in accordance with the test data.It is demonstrated that the sudden change of the current density at both ends of the wall causes the liquid metal to shrink and depress under the electromagnetic force,and the current starts to transfer from the liquid metal path to the wall resistance path.The RWLMCL can effectively advance the starting current-limiting time.
基金financially supported by the project part of the state assignment of the Ministry of Education and Science of Russia in scientific activities,project 3.1262.2014K
文摘A high-voltage transverse pulsed nanosecond discharge with a slotted hollow cathode was found to be a source of high-energy (few kV) ribbon electron beams. Conditions for the formation and extinction of electron beams were experimentally studied in discharges in helium at pressures of 1-100 Torr. It was found that interaction of fast electrons with a non-uniform electric field near the slotted cathode led to limitation of the magnitude of the discharge current. A physical model was developed to describe the discharge current self-limitation that was in satisfactory agreement with the experimental results. Some technical solutions that are expected to increase the upper current limits in transverse nanosecond discharge are discussed.
基金granted by the Korea Research Institute of Chemical Technology(KRICT)of the Republic of Korea(No.2422-10)the National Research Foundation(NRF)(NRF-2021R1C1C2007445 and RS-2023-00280495)of Republic of Korea.
文摘The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations.However,this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors.The weight and thickness of X-ray detectors can be reduced by replacing the silicon layer with an organic photodetectors.This study presents a novel bithienopyrroledione-based polymer donor that exhibits excellent photodetection properties even in a thick photoactive layer(~700 nm),owing to the symmetric backbone and highly soluble molecular structure of bithienopyrroledione.The ability of bithienopyrroledione-based polymer donor to strongly suppress the dark current density(Jd~10−10 A cm^(−2))at a negative bias(−2.0 V)while maintaining high responsivity(R=0.29 A W−1)even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of D_(sh)^(*)=2.18×10^(13)Jones in the organic photodetectors.Printed organic photodetectors are developed by slot-die coating for use in X-ray detectors,which exhibit D_(sh)^(*)=2.73×10^(12)Jones with clear rising(0.26 s)and falling(0.29 s)response times upon X-ray irradiation.Detection reliability is also proven by linear response of the X-ray detector,and the X-ray detection limit is 3 mA.
基金supported by the Technology Project of State Grid(No.SGSNKYOOKJJS1501564)the National Key Basic Research Program of China(973 Program)(No.2015CB251005)
文摘The GaInSn liquid metal current limiter based on the fluid pinch effect has broad application prospects due to its particular properties. However, the limited rated current and abil- ity of power dissipation are the critical problems for its wide application. Firstly, the temperature distribution of the liquid metal current limiter (LMCL) was obtained by experiments with a rated current of 1 kA and the arc ignition phenomenon was observed with 1.5 kA, which indicates that the rated current is mainly limited by the arc rather than the high temperature compared to the traditional switchgears. Furthermore, an improved method is proposed by adding the paralleled pure resistance, impedance or another LMCL element to protect the setup from the fault energy concentration in the setup. The problem of a slower arc voltage increasing rate can be solved by adding a paralleled impedance with suitable parameters. Finally, the current limiting properties based on the improved method were investigated and the alternating oscillating current was found between two paralleled LMCL elements owing to their deviation of arc ignition in reality.
基金National Natural Science Foundation of China(29976040),Natural Science Foundation of AnhuiProvince(99045431),Foundation of Environments and Resources of USTC and Youth Foundation of USTC.
文摘The water dissociation mechanism on a bipolar membrane under the electrical field was investigated and characterized in terms of ionic transport and limiting current density. It is considered that the depletion layer exists at the junction of a bipolar membrane, which is coincided with the viewpoint of the most literatures, but we also consider that the thickness and conductivity of this layer is not only related with the increase of the applied voltage but also with the limiting current density. Below the limiting current density, the thickness of the depletion layer keeps a constant and the conductivity decreases with the increase of the applied voltage; while above the limiting current density, the depletion thickness will increase with the increase of the applied voltage and the conductivity keeps a very low constant. Based on the data reported in the literatures and independent determinations, the limiting current density was calculated and the experimental curves Ⅰ-Ⅴ in the two directions were com
文摘This paper presents a new type of fault current limiter (FCL) based on fast closing switch, which is composed of a capacitor bank and a reactor in series. The main control component is a fast closing switch connected in parallel with the capacitors, which is driven by the electromagnetic repulsion force. It can response the order within 1 ms. When fault occurs, the switch closes and the capacitors are bypassed, and the fault current is limited by the reactor. Simulation analysis and experiment show that the electromagnetic repulsion force actuator can meet the demand of fast closing switch, it is feasible to develop the FCL with low cost and high reliability.
基金supported by National Natural Science Foundation of China(Nos.51777025,52177131)the Interdisciplinary Program of the Wuhan National High Magnetic Field Center(No.WHMFC202130)Huazhong University of Science and Technology。
文摘The liquid metal current limiter(LMCL)is regarded as a viable solution for reducing the fault current in a power grid.But demonstrating the liquid metal arc plasma self-pinching process of the resistive wall,and reducing the erosion of the LMCL are challenging,not only theoretically,but also practically.In this work,a novel LMCL is designed with a resistive wall that can be connected to the current-limiting circuit inside the cavity.Specifically,a novel fault current limiter(FCL)topology is put forward where the novel LMCL is combined with a fast switch and current-limiting reactor.Further,the liquid metal self-pinch effect is modeled mathematically in three dimensions,and the gas-liquid two-phase dynamic diagrams under different short-circuit currents are obtained by simulation.The simulation results indicate that with the increase of current,the time for the liquid metal-free surface to begin depressing is reduced,and the position of the depression also changes.Different kinds of bubbles formed by the depressions gradually extend,squeeze,and break.With the increase of current,the liquid metal takes less time to break,but breaks still occur at the edge of the channel,forming arc plasma.Finally,relevant experiments are conducted for the novel FCL topology.The arcing process and current transfer process are analyzed in particular.Comparisons of the peak arc voltage,arcing time,current limiting efficiency,and electrode erosion are presented.The results demonstrate that the arc voltage of the novel FCL topology is reduced by more than 4.5times and the arcing time is reduced by more than 12%.The erosions of the liquid metal and electrodes are reduced.Moreover,the current limiting efficiency of the novel FCL topology is improved by 1%–5%.This work lays a foundation for the topology and optimal design of the LMCL.
基金This project is funded by the Dongying Science Development Fund Project(DJ2021013).
文摘Due to the low impedance characteristic of the high voltage direct current(HVDC)grid,the fault current rises extremely fast after a DC-side fault occurs,and this phenomenon seriously endangers the safety of the HVDC grid.In order to suppress the rising speed of the fault current and reduce the current interruption requirements of the main breaker(MB),a fault current limiting hybrid DC circuit breaker(FCL-HCB)has been proposed in this paper,and it has the capability of bidirectional fault current limiting and fault current interruption.After the occurrence of the overcurrent in the HVDC grid,the current limiting circuit(CLC)of FCL-HCB is put into operation immediately,and whether the protected line is cut off or resumed to normal operation is decided according to the fault detection result.Compared with the traditional hybrid DC circuit breaker(HCB),the required number of semiconductor switches and the peak value of fault current after fault occurs are greatly reduced by adopting the proposed device.Extensive simulations also verify the effectiveness of the proposed FCL-HCB.
文摘In order to design the technological process of desalination by electrodialysis for the industrial wastewater of an alumina plant, the limit current density of the industrial wastewater is measured, and the equations of limit current density, voltage drop of the unit membrane pair at the limiting current and desalination ratio at the limiting current were obtained.
文摘A two-dimensional solution of space-charge-limiting current for a high current vacuum diode with a spherical cathode is presented. The relation between space-charge-limiting current and electric field enhancement factor at the cathode surface for the diode with a curved surface cathode is also discussed. It is shown that compared with the current given by the conventional Child-Langmuir law, which describes the one-dimensional space-charege-limiting current, the two-dimensional space-charge-limiting current in such a diode is enhanced due to the electric-field enhancement along the cathode surface. Among practical parameter ranges, enhancement factor ηb approximately satisfies ηb Aβn, where β is the electric field enhancement factor at the cathode surface, and n is a constant between 1 and 2, which is confirmed to be universal for the diodes with curved surface cathodes.
基金supported by State Grid Science and Technology Projects(SGTYHT/17-JS-199)National Natural Science Foundation of China(51577163).
文摘The fault current limiter(FCL)is an effective measure for improving system stability and suppressing short-circuit fault current.Because of space and economic costs,the optimum placement of FCLs is vital in industrial applications.In this study,two objectives with the same dimensional measurement unit,namely,the total capital investment cost of FCLs and circuit breaker loss related to short-circuit currents,are considered.The circuit breaker loss model is developed based on the attenuation rule of the circuit breaker service life.The circuit breaker loss is used to quantify the current-limiting effect to avoid the problem of weight selection in a multi-objective problem.The IEEE 10-generator 39-bus system in New England is used to evaluate the performance of the proposed genetic algorithm(GA)method.Comparative and sensitivity analyses are performed.The results of the optimized plan are validated through simulations,indicating the significant potential of the GA for such optimization.
基金Project supported by the National Natural Science Foundation of China (Grant No 10476004).
文摘The self-consistent differential equations, which describe a laminar-flow equilibrium state in a magnetically focused intense relativistic electron beam propagating inside a conducting waveguide, are presented. The canonical angular momentum, Pe, defined under the conditions at the source, uniquely determines the possible solutions of these equations. By numerically solving these equations, the space-charge limited current and the externally applied magnetic field are obtained in a solid beam and a hollow beam in two cases of Pθ= 0 (magnetically shielded source) and Pθ= const. (immersed source) separately. It is shown that the hollow beam is more beneficial to the propagation of the intense relativistic beam through a drift tube than the solid beam.
文摘A new type of fault current limiter (FCL) with series compensation based fast-closing switch is proposed. It is composed of a capacitor bank and a reactor in series. The main control component is a fast-closing switch connected in parallel with the capacitors, which is driven by the electromagnetic repulsion force. When fault occurs, the switch closes and bypasses the capacitors, and the fault is limited by the reactor then. Simulated analysis and experiments show that it is feasible to develop the FCL with low cost and high reliability. The effectiveness of transient stability for power system is evaluated by digital simulation.
基金supported by the National Natural Science Foundation of China(No.91545124,No.21972131,and No.21832004)。
文摘Rotating disk electrode systems are widely used to study the kinetics of electrocatalytic reactions that may suffer from insufficient mass transfer of the reactants.Kinetic current density at certain overpotential calculated by the Koutecky-Levich equation is commonly used as the metrics to evaluate the activity of electrocatalysts.However,it is frequently found that the diffusion limiting current density is not correctly identified in the literatures.Instead of kinetic current density,the measured current density normalized by diffusion limiting current density(j/jL)has also been frequently under circumstance where its validity is not justified.By taking oxygen reduction reaction/hydrogen oxidation reaction/hydrogen evolution reaction as examples,we demonstrate that identifying the actual diffusion limiting current density for the same reaction under otherwise identical conditions from the experimental data is essential to accurately deduce kinetic current density.Our analysis reveals that j/jLis a rough activity metric which can only be used to qualitatively compare the activity trend under conditions that the mass transfer conditions and the roughness factor of the electrode are exactly the same.In addition,if one wants to use j/jLto compare the intrinsic activity,the concentration overpotential should be eliminated.
文摘This article gives an overview of the main passive solutions and active techniques, based on AC switches to limit inrush currents in medium power AC-DC converters (up to 3.7 kW) for electric vehicle charging systems. In particular, a strategy, based on SCR (silicon controlled rectifier) phase, shift control in a mixed rectifier bridge with diodes and thyristors, is proposed. The challenge is to help designers optimize the triggering delay of SCRs to both limit the peak value of inrush current spikes and optimize the charge duration of the DC-link capacitor. A mathematical model (Mathcad engineering tool) has been defined to point out, the interest of a variable triggering delay to control SCRs to meet the expectations described previously. Experimental measurements using an industrial evaluation board of the AC-DC converter demonstrate the robustness of the method.
文摘Protection of radial distribution networks is widely based on coordinated inverse time overcurrent relays (OCRs) ensuring both effectiveness and selectivity. However, the integration of distributed generation (DG) into an existing distribution network not only inevitably increases fault current levels to levels that may exceed the OCR ratings, but it may also disturb the original overcurrent relay coordination adversely effecting protection selectivity. To analyze the potentially adverse impact of DG on distribution system protective devices with respect to circuit breaker ratings and OCR coordination fault current studies are carried out for common reference test system under the influence of additional DG. The possible advantages of Superconducting Fault Current Limiter (SFCL) as a means to limit the adverse effect of DG on distribution system protection and their effectiveness will be demonstrated. Furthermore, minimum SFCL impedances required to avoid miss-operation of the primary and back-up OCRs are determined. The theoretical analysis will be validated using the IEEE 13-bus distribution test system is used. Both theoretical and simulation results indicate that the proposed application of SFCL is a viable option to effectively mitigate the DG impact on protective devices, thus enhancing the reliability of distribution network interfaced with DG.
文摘The effectiveness of a combination of fault current limiter and thyristor controlled braking resistor on power system stability enhancement and damping turbine shaft torsional oscillations has been studied. If both devices operate at the same bus, the stabilization control scheme can be carried out continuously and with flexibility. As a result, the fault currents are limited, and the generator disturbances and the turbine shaft torsional oscillations are converged quickly. In this paper, the effectiveness of the combination of both devices has been demonstrated by considering 3LG (three-lines-to-ground) fault in a two-machine infinite bus system. Also, temperature rise effect of both devices with various resistance values and weights has been demonstrated. Simulation results indicate a significant power system stability enhancement and damping turbine shaft torsional oscillations as well as with allowable temperature rise.
文摘Fault current suppression is the key technology to ensure the safe operation of the DC power distribution system. In order to realize the parameter collabora-tive configuration of the DC circuit breaker and the DC current limiter and improve the fault current suppression capability, the fault current suppression mechanism of the DC power distribution system is revealed based on the circuit model. Then, based on the mathematical model of the DC breaker, the characteristic parameters of DC breaking are extracted, and then the influence of different characteristic parameters on the breaking characteristics of fault current is studied. Finally, the mathematical model of the collaborative process between DC circuit breaker and DC current limiter is established. The charac-teristic parameters of fault current collaborative suppression are extracted. The coupling effects of different characteristic parameters on the fault current col-laborative suppression are studied. The principle of collaborative configuration of DC circuit breaker and DC current limiter is proposed, and the collaborative suppression ability of DC circuit breaker and DC current limiter to fault current is fully exploited to ensure the safe and reliable operation of the DC power distribution system.
基金supported by National MCF Energy R&D Program of China(No.2019YFE03010004)National Key R&D Program of China(No.2018YFE0309100)+1 种基金National Natural Science Foundation of China(Nos.11775089 and 51821005)National Magnetic Confinement Fusion Science Program of China(Nos.2015GB111002 and 2015GB104000)
文摘The avoidance of runaway electrons(REs) generated during plasma disruption is of great concern for the safe operation of tokamak devices.Experimental study on the suppression of runaway current by electrode biasing(EB) and limiter biasing(LB) has been performed on the J-TEXT tokamak,which could be an alternative way to suppress the runaway current.The experimental results show that the higher the voltage value,the smaller the runaway current in both EB and LB experiments.The runaway current can be completely suppressed at an electrode biased voltage of +450 V and a limiter biased voltage of +300 V.The comparison of the energy spectra during the runaway plateau phase shows that the maximum energy max(E_(RE)) and radiation temperature T_(HXR)hard x-rays(HXRs)are significantly reduced after the application of +200 V limiter biased voltage.The electric field generated by the biased voltage may be the key factor to suppress the runaway current,and the measured radial electric field increases obviously after the voltage is applied.This may result in an increase in the loss of REs to realize the suppression of runaway current.