SV/IEEE 802.15.3a model has been the standard model for Ultra-wide bandwidth (UWB) indoor non-line-of-sight (NLOS) wireless propagation,but for line-of-sight (LOS) case,it is not well defined. In this paper,a new stat...SV/IEEE 802.15.3a model has been the standard model for Ultra-wide bandwidth (UWB) indoor non-line-of-sight (NLOS) wireless propagation,but for line-of-sight (LOS) case,it is not well defined. In this paper,a new statistical distribution model exclusively used for LOS environment is proposed based on investigation of the experimental data. By reducing the number of the visible random arriving clusters,the model itself and the parameters estimating of the corresponding model are simplified in comparison with SV/IEEE 802.15.3a model. The simulation result indicates that the proposed model is more accurate in modeling small-scale LOS environment than SV/IEEE 802.15.3a model when considering cumulative distribution functions (CDFs) for the three key channel impulse response (CIR) statistics.展开更多
The epithermal neutron shape factor (α) was determined in the permanent cadmium lined irradiation channel installed in the large outer irradiation site of the Nigeria Research Reactor-1 (NIRR- 1) by the cadmium cover...The epithermal neutron shape factor (α) was determined in the permanent cadmium lined irradiation channel installed in the large outer irradiation site of the Nigeria Research Reactor-1 (NIRR- 1) by the cadmium covered multimonitor method using the monitors Al-0.1% Au, Zr and Zn thin foils and Mo thin wire and was found to be -0.137 ± 0.018. The high negative value of α indicates a hardened epithermal neutron spectrum in the cadmium lined irradiation channel. The α value obtained was used in the single comparator method of ENAA (ko-ENAA) for the determination of the concentrations of elements in the standard reference material NIST 1515 Apple leaves using Al-0.1% Au thin foil as the single comparator. The concentrations of the elements Sm and Br were determined in the NIST 1515 Apple leaves because of their high Qo values and are in good agreement with the certified values.展开更多
Many kinds of channel currents are especially weak and the background noise dominates in the patch clamp recordings. This makes the threshold detection fail during estimating of the transition probabilities. So direct...Many kinds of channel currents are especially weak and the background noise dominates in the patch clamp recordings. This makes the threshold detection fail during estimating of the transition probabilities. So direct fitting of the patch clamp recording, not of the histogram coming from the recordings, is a desirable way to estimate the transition probabilities. Iterative batch EM algorithm based on hidden markov model has been used in this field but which has the "curse of dimensionality" and besides cant keep tracking the varying of the parameters. A new on line sequential iterative one is proposed here, which needs fewer computational efforts and can adaptively keep tracking the varying of parameters. Simulations suggest its robust, effective and convenient.展开更多
基金the Key Program of National Natural Science Foundation of China(Grant No.60432040).
文摘SV/IEEE 802.15.3a model has been the standard model for Ultra-wide bandwidth (UWB) indoor non-line-of-sight (NLOS) wireless propagation,but for line-of-sight (LOS) case,it is not well defined. In this paper,a new statistical distribution model exclusively used for LOS environment is proposed based on investigation of the experimental data. By reducing the number of the visible random arriving clusters,the model itself and the parameters estimating of the corresponding model are simplified in comparison with SV/IEEE 802.15.3a model. The simulation result indicates that the proposed model is more accurate in modeling small-scale LOS environment than SV/IEEE 802.15.3a model when considering cumulative distribution functions (CDFs) for the three key channel impulse response (CIR) statistics.
文摘The epithermal neutron shape factor (α) was determined in the permanent cadmium lined irradiation channel installed in the large outer irradiation site of the Nigeria Research Reactor-1 (NIRR- 1) by the cadmium covered multimonitor method using the monitors Al-0.1% Au, Zr and Zn thin foils and Mo thin wire and was found to be -0.137 ± 0.018. The high negative value of α indicates a hardened epithermal neutron spectrum in the cadmium lined irradiation channel. The α value obtained was used in the single comparator method of ENAA (ko-ENAA) for the determination of the concentrations of elements in the standard reference material NIST 1515 Apple leaves using Al-0.1% Au thin foil as the single comparator. The concentrations of the elements Sm and Br were determined in the NIST 1515 Apple leaves because of their high Qo values and are in good agreement with the certified values.
文摘Many kinds of channel currents are especially weak and the background noise dominates in the patch clamp recordings. This makes the threshold detection fail during estimating of the transition probabilities. So direct fitting of the patch clamp recording, not of the histogram coming from the recordings, is a desirable way to estimate the transition probabilities. Iterative batch EM algorithm based on hidden markov model has been used in this field but which has the "curse of dimensionality" and besides cant keep tracking the varying of the parameters. A new on line sequential iterative one is proposed here, which needs fewer computational efforts and can adaptively keep tracking the varying of parameters. Simulations suggest its robust, effective and convenient.