In the conventional technique,in the evaluation of the severity index,clustering and loading suffer from more iteration leading to more com-putational delay.Hence this research article identifies,a novel progression f...In the conventional technique,in the evaluation of the severity index,clustering and loading suffer from more iteration leading to more com-putational delay.Hence this research article identifies,a novel progression for fast predicting the severity of the line and clustering by incorporating machine learning aspects.The polynomial load modelling or ZIP(constant impedances(Z),Constant Current(I)and Constant active power(P))is developed in the IEEE-14 and Indian 118 bus systems considered for analysis of power system security.The process of finding the severity of the line using a Hybrid Line Stability Ranking Index(HLSRI)is used for assisting the concepts of machine learning with J48 algorithm,infers the superior affected lines by adopting the IEEE standards in concern to be compensated in maintaining the power system stability.The simulation is performed in the WEKA environment and deals with the supervisor learning in order based on severity to ensure the safety of power system.The Unified Power Flow Controller(UPFC),facts devices for the purpose of compensating the losses by maintaining the voltage characteristics.The finite element analysis findings are compared with the existing procedures and numerical equations for authentications.展开更多
In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. ...In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines.展开更多
The refraction index of the quantized lossy composite right-left handed transmission line(CRLH-TL) is deduced in the thermal coherence state. The results show that the negative refraction index(herein the left-hand...The refraction index of the quantized lossy composite right-left handed transmission line(CRLH-TL) is deduced in the thermal coherence state. The results show that the negative refraction index(herein the left-handedness) can be implemented by the electric circuit dissipative factors(i.e., the resistances R and conductances G) in a higher frequency band(1.446 GHz≤ ω ≤ 15 GHz), and flexibly adjusted by the left-handed circuit components(Cl, Ll) and the right-handed circuit components(Cr, Lr) at a lower frequency(ω = 0.995 GHz). The flexible adjustment for left-handedness in a wider bandwidth will be significant for the microscale circuit design of the CRLH-TL and may make the theoretical preparation for its compact applications.展开更多
We demonstrate applications of a novel setup which is used for measuring the relative phase difference between S and P polarization at an oblique incidence point in optically denser medium by analyzing the relative fr...We demonstrate applications of a novel setup which is used for measuring the relative phase difference between S and P polarization at an oblique incidence point in optically denser medium by analyzing the relative frequency shift of adjacent axial modes of S and P resonances of a monolithic folded Fabry-Perot cavity (MFC). The relative phase difference at a reflection point A in an optically denser medium is inferred to be around -167.4°<span "=""> for a confocal cavity and -201.1° for a parallel cavity. Given the <i>n</i><sub>1</sub>, <i>n</i><sub>3</sub>, <i>φ</i><sub>1</sub>, <i>φ</i><sub>3</sub>, <i>λ</i></span><span "="">, and Δ, the elliptic formula tan(<i>ψ</i>)exp(<i>i</i>Δ) = <i>R<sub>p</sub></i>/<i>R<sub>s</sub></i> is used to find a solution for thickness d and refractive index </span><i>n</i><sub>2</sub><span "=""> of the thin film coated on point A, where <i>R<sub>s</sub></i> and <i>R<sub>p</sub></i> are total refractive index of <i>s</i> and<i> p</i> component of light related to two unknown values. Since it is hard to deduce an analytical solution for thickness and refractive index of the film, we firstly used exhaustion method to find the set of solution about thickness and refractive index when assumed there is no light absorption by the film and then Particle Swarm Optimization (PSO) to find a set of solution of thickness and complex refractive index which accounts the light absorption by the film.展开更多
文摘In the conventional technique,in the evaluation of the severity index,clustering and loading suffer from more iteration leading to more com-putational delay.Hence this research article identifies,a novel progression for fast predicting the severity of the line and clustering by incorporating machine learning aspects.The polynomial load modelling or ZIP(constant impedances(Z),Constant Current(I)and Constant active power(P))is developed in the IEEE-14 and Indian 118 bus systems considered for analysis of power system security.The process of finding the severity of the line using a Hybrid Line Stability Ranking Index(HLSRI)is used for assisting the concepts of machine learning with J48 algorithm,infers the superior affected lines by adopting the IEEE standards in concern to be compensated in maintaining the power system stability.The simulation is performed in the WEKA environment and deals with the supervisor learning in order based on severity to ensure the safety of power system.The Unified Power Flow Controller(UPFC),facts devices for the purpose of compensating the losses by maintaining the voltage characteristics.The finite element analysis findings are compared with the existing procedures and numerical equations for authentications.
文摘In order to improve the lightning protection performance of transmission lines, lightning protection management has been divided into every tower that lightning protection performance has been evaluated respectively. According to factors such as landform, span, tower type, grounding resistance, isolator type, and so on, relative ratio of tripping operation of every tower in the line has been calculated to evaluate its lightning protection safety performance, it is beneficial to operation maintenance and lightning reconstruction of transmission lines.
基金supported by the National Natural Science Foundation of China(Grant Nos.61205205 and 6156508508)the General Program of Yunnan Provincial Applied Basic Research Project,China(Grant No.2016FB009)the Foundation for Personnel Training Projects of Yunnan Province,China(Grant No.KKSY201207068)
文摘The refraction index of the quantized lossy composite right-left handed transmission line(CRLH-TL) is deduced in the thermal coherence state. The results show that the negative refraction index(herein the left-handedness) can be implemented by the electric circuit dissipative factors(i.e., the resistances R and conductances G) in a higher frequency band(1.446 GHz≤ ω ≤ 15 GHz), and flexibly adjusted by the left-handed circuit components(Cl, Ll) and the right-handed circuit components(Cr, Lr) at a lower frequency(ω = 0.995 GHz). The flexible adjustment for left-handedness in a wider bandwidth will be significant for the microscale circuit design of the CRLH-TL and may make the theoretical preparation for its compact applications.
文摘We demonstrate applications of a novel setup which is used for measuring the relative phase difference between S and P polarization at an oblique incidence point in optically denser medium by analyzing the relative frequency shift of adjacent axial modes of S and P resonances of a monolithic folded Fabry-Perot cavity (MFC). The relative phase difference at a reflection point A in an optically denser medium is inferred to be around -167.4°<span "=""> for a confocal cavity and -201.1° for a parallel cavity. Given the <i>n</i><sub>1</sub>, <i>n</i><sub>3</sub>, <i>φ</i><sub>1</sub>, <i>φ</i><sub>3</sub>, <i>λ</i></span><span "="">, and Δ, the elliptic formula tan(<i>ψ</i>)exp(<i>i</i>Δ) = <i>R<sub>p</sub></i>/<i>R<sub>s</sub></i> is used to find a solution for thickness d and refractive index </span><i>n</i><sub>2</sub><span "=""> of the thin film coated on point A, where <i>R<sub>s</sub></i> and <i>R<sub>p</sub></i> are total refractive index of <i>s</i> and<i> p</i> component of light related to two unknown values. Since it is hard to deduce an analytical solution for thickness and refractive index of the film, we firstly used exhaustion method to find the set of solution about thickness and refractive index when assumed there is no light absorption by the film and then Particle Swarm Optimization (PSO) to find a set of solution of thickness and complex refractive index which accounts the light absorption by the film.