This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission...This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.展开更多
To quantitatively study the location errors induced by deviation of sonic speed, the line and plane location tests were carried out. A broken pencil was simulated as acoustic emission source in the rocks. The line and...To quantitatively study the location errors induced by deviation of sonic speed, the line and plane location tests were carried out. A broken pencil was simulated as acoustic emission source in the rocks. The line and plane location tests were carried out in the granite rod using two sensors and the cube of marble using four sensors, respectively. To compare the position accuracy between line and plane positions, the line poison test was also carried out on the marble surface. The results show that for line positioning, the maximum error of absolute distance is about 0.8 cm. With the speed difference of 200 m/s, the average value of absolute difference from the position error is about 0.4 cm. For the plane positioning, in the case of the sensor array of 30 cm, the absolute positioning distance is up to 8.7 cm. It can be seen that the sonic speed seriously impacts on the plane positioning accuracy. The plane positioning error is lager than the line positioning error, which means that when the line position can satisfy the need in practical engineering, it is better to use the line position instead of the plane location. The plane positioning error with the diagonal speed is the minimum one.展开更多
In long transmission lines,the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location.To improve the accuracy of fault location,this paper presents a novel scheme,whe...In long transmission lines,the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location.To improve the accuracy of fault location,this paper presents a novel scheme,where two Digital Fault Recorders(DFRs)are installed in a line.They can send the transient data of the faults to the both ends of a line.To estimate the distance of a fault,impedance based fault location methods are applied with transient fault data of both ends protection relays and both DFRs installed in a line.To evaluate the proposed scheme,a laboratory setup has been developed.In the lab,several faults have been simulated and associated voltages and currents are injected to a relay IED to compare experimental results.展开更多
This paper presents results of model tests for the landslide dam failure of a single dam and cascade dams in a sloping channel. The dams were designed to be regular trapezoid with fine sand. A new measuring method nam...This paper presents results of model tests for the landslide dam failure of a single dam and cascade dams in a sloping channel. The dams were designed to be regular trapezoid with fine sand. A new measuring method named the labeled line locating method was used to digitalize the captured instantaneous pictures. Under two different inflow discharges, the morphological evolution and the flow patterns during one dam failure and the failure of cascade dams were investigated. The results indicate that when the inflow discharge is large, the deformation pattern of the downstream dam is similar to that of the upstream dam, and both dams are characterized with the overtopping scour throughout the dam failure process. When the inflow discharge is small, the upstream dam is scoured mainly through a sluice slot formed by the longitudinal incision, and the downstream dam is characterized with the overtopping scour. The data set presented in this paper can be used for the validation of numerical models and provide a reference for the flood risk management of cascade landslide dams.展开更多
文摘This paper describes the functions and the features of the integrated system of aerial survey and tower locations optimization for transmission lines, which includes all stages from data acquisition, data transmission and data processing to automatic optimization of the tower locations and drawing. The paper also briefly describes the economic benefit gained from this system, and finally proposes the directions of the future development for this system.
基金Projects (50934006, 10872218) supported by the National Natural Science Foundation of ChinaProject (2010CB732004) supported by the National Basic Research Program of ChinaProject (kjdb2010-6) supported by Doctoral Candidate Innovation Research Support Program of Science & Technology Review, China
文摘To quantitatively study the location errors induced by deviation of sonic speed, the line and plane location tests were carried out. A broken pencil was simulated as acoustic emission source in the rocks. The line and plane location tests were carried out in the granite rod using two sensors and the cube of marble using four sensors, respectively. To compare the position accuracy between line and plane positions, the line poison test was also carried out on the marble surface. The results show that for line positioning, the maximum error of absolute distance is about 0.8 cm. With the speed difference of 200 m/s, the average value of absolute difference from the position error is about 0.4 cm. For the plane positioning, in the case of the sensor array of 30 cm, the absolute positioning distance is up to 8.7 cm. It can be seen that the sonic speed seriously impacts on the plane positioning accuracy. The plane positioning error is lager than the line positioning error, which means that when the line position can satisfy the need in practical engineering, it is better to use the line position instead of the plane location. The plane positioning error with the diagonal speed is the minimum one.
文摘In long transmission lines,the charging current caused by the shunt capacitance decreases the accuracy in impedance based fault location.To improve the accuracy of fault location,this paper presents a novel scheme,where two Digital Fault Recorders(DFRs)are installed in a line.They can send the transient data of the faults to the both ends of a line.To estimate the distance of a fault,impedance based fault location methods are applied with transient fault data of both ends protection relays and both DFRs installed in a line.To evaluate the proposed scheme,a laboratory setup has been developed.In the lab,several faults have been simulated and associated voltages and currents are injected to a relay IED to compare experimental results.
基金supported by the National Basic Research and Development Program of China(973 Program,Grant No.2007CB714105)the National Natural Science Foundation of China(Grant No.50909067)
文摘This paper presents results of model tests for the landslide dam failure of a single dam and cascade dams in a sloping channel. The dams were designed to be regular trapezoid with fine sand. A new measuring method named the labeled line locating method was used to digitalize the captured instantaneous pictures. Under two different inflow discharges, the morphological evolution and the flow patterns during one dam failure and the failure of cascade dams were investigated. The results indicate that when the inflow discharge is large, the deformation pattern of the downstream dam is similar to that of the upstream dam, and both dams are characterized with the overtopping scour throughout the dam failure process. When the inflow discharge is small, the upstream dam is scoured mainly through a sluice slot formed by the longitudinal incision, and the downstream dam is characterized with the overtopping scour. The data set presented in this paper can be used for the validation of numerical models and provide a reference for the flood risk management of cascade landslide dams.