Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of t...Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of the line topology switched Ethernet as a data acquisition network.Network calculus theory,which has been successfully applied to assess the real-time performance of packet-switched networks,is used to analyze the networks.To properly describe the activity of switches,a novel approach of modeling data flows into or out of switches is addressed.Based on our model,a concisely analytical expression of the maximal end-to-end delay in line topology switched Ethernet is derived.Finally,the relative simulation results are demonstrated.These results agree well with the analytical results,and thus they validate the data flow modeling techniques.展开更多
Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit mo...Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.展开更多
Introduction: Over the past years, efforts have been made to expand access to antiretroviral combinations (cART) in low-income countries. However, major concerns are noted with drug resistance emergence, as treatment ...Introduction: Over the past years, efforts have been made to expand access to antiretroviral combinations (cART) in low-income countries. However, major concerns are noted with drug resistance emergence, as treatment failure result and need to introduce a second line treatment, more expensive and difficult to implement. The objective was to study the incidence of switch to second line, reasons for switch and risk factors using a cohort of people living with HIV in an Ambulatory Treatment Center in Dakar. Methodology: This was a cohort study of people living with HIV under cART from January 2004 to December 2013. Naive patients monitored for at least six months, regardless of their profile and regimen with baseline CD4 counts Results: The median age of the 827 patients included was 44 [IQR = 18 - 78]. The switch to second-line treatment was observed in 72 patients (8.7%) after an average of 38.5 months of follow-up. The overall incidence rate of switch to second line of antiretroviral treatment was 1.59 per 100 persons-years. Most of changes in first-line treatment were motivated by virological failures (n = 60, 83.3%) under treatment with AZT/3TC/NVP (n = 25, 34.7%) or AZT/3TC/EFV21 (29.2%). 9.7% of switch occurred after immunological failure, 1.4% after clinical failure, 4.2% after severe toxicity and 1.4% was not documented. Predictive factors identifying failures at the end of the multivariate analysis were age Conclusions: In total, CTA identified a low incidence rate of treatment failure of the first line of treatment. Associated risk factors were age < 44 years, CD4 counts below 100 cells/mm<sup>3</sup> and high viral load at treatment initiation.展开更多
The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investi...The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investigate the characteristics of the transmission line, many tests were performed on the line before and after its operation. The results indicate that all electrical parameters are perfectly identical to the design.展开更多
文摘Recently,switched Ethernet has become an active area of research because of its wide uses in industry.However,its uses have various real-time constraints on data communications.This paper analyzes the performance of the line topology switched Ethernet as a data acquisition network.Network calculus theory,which has been successfully applied to assess the real-time performance of packet-switched networks,is used to analyze the networks.To properly describe the activity of switches,a novel approach of modeling data flows into or out of switches is addressed.Based on our model,a concisely analytical expression of the maximal end-to-end delay in line topology switched Ethernet is derived.Finally,the relative simulation results are demonstrated.These results agree well with the analytical results,and thus they validate the data flow modeling techniques.
基金supported by National Natural Science Foundation of China(Nos.51307141,51077111)by the State Key Laboratory Foundational Research Funds of China(Nos.SKLIPR1302Z,SKLIPR1306)
文摘Based on the transmission line code (TLCODE), a circuit model is developed here for analyses of main switches in the high pulsed-power facilities. With the structure of the ZR main switch as an example, a circuit model topology of the switch is proposed, and in particular, calculation methods of the dynamic inductance and resistance of the switching arc are described. Moreover, a set of closed equations used for calculations of various node voltages are theoretically derived and numericMly discretized. Based on these discrete equations and the Matlab program, a simulation procedure is established for analyses of the ZR main switch. Voltages and currents at different key points are obtained, and comparisons are made with those of a PSpice L-C model. The comparison results show that these two models are perfectly in accord with each other with discrepancy less than 0.1%, which verifies the effectiveness of the TLCODE model to a certain extent.
文摘Introduction: Over the past years, efforts have been made to expand access to antiretroviral combinations (cART) in low-income countries. However, major concerns are noted with drug resistance emergence, as treatment failure result and need to introduce a second line treatment, more expensive and difficult to implement. The objective was to study the incidence of switch to second line, reasons for switch and risk factors using a cohort of people living with HIV in an Ambulatory Treatment Center in Dakar. Methodology: This was a cohort study of people living with HIV under cART from January 2004 to December 2013. Naive patients monitored for at least six months, regardless of their profile and regimen with baseline CD4 counts Results: The median age of the 827 patients included was 44 [IQR = 18 - 78]. The switch to second-line treatment was observed in 72 patients (8.7%) after an average of 38.5 months of follow-up. The overall incidence rate of switch to second line of antiretroviral treatment was 1.59 per 100 persons-years. Most of changes in first-line treatment were motivated by virological failures (n = 60, 83.3%) under treatment with AZT/3TC/NVP (n = 25, 34.7%) or AZT/3TC/EFV21 (29.2%). 9.7% of switch occurred after immunological failure, 1.4% after clinical failure, 4.2% after severe toxicity and 1.4% was not documented. Predictive factors identifying failures at the end of the multivariate analysis were age Conclusions: In total, CTA identified a low incidence rate of treatment failure of the first line of treatment. Associated risk factors were age < 44 years, CD4 counts below 100 cells/mm<sup>3</sup> and high viral load at treatment initiation.
文摘The paper deals with the tests on the first 500 kV compact transmission line. The transmission line stretches from Fangshan Substation to Changping Substation nearby Beijing with a length of 83 km. In order to investigate the characteristics of the transmission line, many tests were performed on the line before and after its operation. The results indicate that all electrical parameters are perfectly identical to the design.