A design for instantaneous neutron flux signal acquisition system is being carried out for reactivity measurement of the nuclear research reactor. It is a computer-based digital data acquisition system that can perfor...A design for instantaneous neutron flux signal acquisition system is being carried out for reactivity measurement of the nuclear research reactor. It is a computer-based digital data acquisition system that can perform continuous monitor and measurement of reactivity inserted into or removed from the research reactor. The acquisition system accomplishes with two major parts. The first part is an interfacing PCI based data acquisition card and the corresponding driver software intending to on-line acquisition of neutron flux signals from plant instrumentation channel. The second part incorporates the high-level Visual Basic real time program, indigenously developed for computation of reactivity by the solution of neutron point kinetic equations and other relevant functional modules like input file logging, reactivity calculation, graphics demonstration etc.展开更多
The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV)...The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.展开更多
针对中国石油化工股份有限公司广州分公司的1.5 Mt/a S Zorb装置,考察了影响装置长周期平稳运行的因素。采取使用国产高通量滤芯及在转剂线上使用耐磨管件,对再生取热盘管进行改造,对闭锁料斗程控阀进行预防性维修等措施解决了装置长周...针对中国石油化工股份有限公司广州分公司的1.5 Mt/a S Zorb装置,考察了影响装置长周期平稳运行的因素。采取使用国产高通量滤芯及在转剂线上使用耐磨管件,对再生取热盘管进行改造,对闭锁料斗程控阀进行预防性维修等措施解决了装置长周期运行瓶颈,实现了在95.06%设计负荷工况下连续平稳运行超过49个月的目标,关键设备反应器过滤器运行超过4 a,期间压差未超过30 kPa。展开更多
文摘A design for instantaneous neutron flux signal acquisition system is being carried out for reactivity measurement of the nuclear research reactor. It is a computer-based digital data acquisition system that can perform continuous monitor and measurement of reactivity inserted into or removed from the research reactor. The acquisition system accomplishes with two major parts. The first part is an interfacing PCI based data acquisition card and the corresponding driver software intending to on-line acquisition of neutron flux signals from plant instrumentation channel. The second part incorporates the high-level Visual Basic real time program, indigenously developed for computation of reactivity by the solution of neutron point kinetic equations and other relevant functional modules like input file logging, reactivity calculation, graphics demonstration etc.
基金ABB (China) Research Ltd. and National Natural Science Foundation of China(No.50477037)
文摘The overvoltage phenomena of ultra high voltage (UHV) transmission lines are analyzed and verified by EMTDC/PSCAD simulation. Referring to the theoretical analyses and operating experiences of extra high voltage (EHV) transmission lines in China and UHV transmission lines in Russia and Japan, the methods to suppress the internal overvoltage in UHV transmission lines by protection and control strategies are discussed. Through the cooperation among the recloser, shunt reactor, tripping and closing resistance, and metal oxide varistor(MOV), the overvoltage can be restrained within an acceptable level.