Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in c...Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations.In this paper,to check the offset from the mechanical to electrical center in low temperature(77 K),Fourier's law and finite element method are used to simulate cryo-deformation.Laser tracker and micro-alignment telescope are employed in combined BPM calibration,installation and monitoring.The calibration error is<0.02 mm,and the installation and monitoring precision are 0.06 mm and 0.01 mm,respectively.The monitored cryo-deformation agrees well with the simulation results.These indicate that the combined alignment can improve performance of the BPM system.All these guaranteed the success of running the 9.55 MeV@2.14 mA cw protons.展开更多
The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the or...The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity.展开更多
In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of r...In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.展开更多
Beam position monitors(BPMs)have been widely used in all kinds of measurement systems,feedback systems and other areas in particle accelerator field these days.The malfunction of a single BPM can cause serious consequ...Beam position monitors(BPMs)have been widely used in all kinds of measurement systems,feedback systems and other areas in particle accelerator field these days.The malfunction of a single BPM can cause serious consequences such as the failure of the orbit feedback and the transverse feedback.A troubleshooting has been made to prevent the defective BPMs from affecting the accuracy and stability of the storage ring in Shanghai Synchrotron Radiation Facility(SSRF).Different types of malfunctions have been successfully identified by using the idea of principal component analysis(PCA).展开更多
The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ...The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.展开更多
In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used t...In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used to correct the position drift and angle variation of the light source at the same time.On introducing the feedback principle,the transfer function matrix is calibrated,indicating that the new system is workable and effective.展开更多
Beam position monitors(BPMs)are important to monitor the beam moving steadily.Keeping the beam's normal motion is an important mission for Shanghai Synchrotron Radiation Facility.Effective diagnostic analysis is a...Beam position monitors(BPMs)are important to monitor the beam moving steadily.Keeping the beam's normal motion is an important mission for Shanghai Synchrotron Radiation Facility.Effective diagnostic analysis is an important way to accomplish this task.This paper develops a new method based on clustering analysis to diagnose the healthy of BPMs with basic running data,i.e.,the β oscillation of X and Y directions and noise data.The analysis results showed that all beam position monitors(140 BPMs)can be classified into three groups:normal group,worse performance group,and fault group,respectively.In addition,the abnormal BPMs(including worse performance)could be marked.The new method showed its ability to handle faulty BPMs and it could instruct daily maintenance.On the other hand,it will be a useful supplement for data analysis in accelerator physics.展开更多
As an important part of the beam diagnostic system, the synchrotron light beam position measurement has a very high value in the high quality and high stability light source applied research. A new photon beam positio...As an important part of the beam diagnostic system, the synchrotron light beam position measurement has a very high value in the high quality and high stability light source applied research. A new photon beam position monitor based on position-sensitive detector (PSD) has been developed to measure the photon beam position in vertical and horizontal directions at the same time at HLS (Hefei Light Source). The new PBPM based on the PSD has fast response speed, high sensitivity and wide dynamic range. This PBPM system also includes the C4674 signal processing circuit, NI USB-9215 data acquisition device and the LABVIEW data acquisition program. This PBPM system has been calibrated vertically and horizontally on-line, and then has been applied in the beam line B3EA of HLS to measure the position of the synchrotron light. As the results shown, the resolution of the system is better than 3 mm.展开更多
A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods...A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and compared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is investigated. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn(TBT) position resolution better than 1 μm is achieved, and the slow-acquisition(SA) position resolution is improved from 4.28 μm to 0.17 μm.展开更多
Purpose The absolute beam position measurement in the booster and storage ring of the high energy photon source(HEPS)requires the offset between the electrical and mechanical centers of the beam position monitor(BPM)....Purpose The absolute beam position measurement in the booster and storage ring of the high energy photon source(HEPS)requires the offset between the electrical and mechanical centers of the beam position monitor(BPM).Method Traditionally,an RF signal is sent to an antenna or stretched wire aligned with the vacuum chamber,and the signal at each electrode is measured.Conversely,a replacement method using a vector network analyzer,which was proposed by Lambertson,does not involve mechanical alignment and can be used for electrical offset determination.Results and conclusions The electro-mechanical offsets of booster BPMs of the HEPS were measured using the Lambertson method.The result shows good agreement with the stretched wire method within a 30μm error.展开更多
Beam Position Monitors(BPMs) for the low-β beam of the Chinese Accelerator Driven Subcritical system(CADS) Proton linac are of the capacitive pick-up type.They provide higher output signals than that of the induc...Beam Position Monitors(BPMs) for the low-β beam of the Chinese Accelerator Driven Subcritical system(CADS) Proton linac are of the capacitive pick-up type.They provide higher output signals than that of the inductive type.This paper will describe the design and tests of the capacitive BPM system for the low-β proton linac,including the pick-ups,the test bench and the read-out electronics.The tests done with an actual proton beam show a good agreement between the measurements and the simulations in the time domain.展开更多
In this paper, the 2-D electrostatic field software, POISSON, is used to calculate the characteristic impedance of a BPM (beam position monitor) for a high current proton linac. Furthermore, the time-domain 3-D modu...In this paper, the 2-D electrostatic field software, POISSON, is used to calculate the characteristic impedance of a BPM (beam position monitor) for a high current proton linac. Furthermore, the time-domain 3-D module of MAFIA with a beam microbunch at a varying offset from the axis is used to compute the induced voltage on the electrodes as a function of time. Finally, the effect of low β beams on the induced voltage, the sensitivity and the signal dynamic range of the BPM are discussed.展开更多
The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline ele...The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.展开更多
Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron ...Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron Positron Collider(BEPCII),which brings great challenges to the test work.In order to achieve accurate,fast,and complete mass production tests of DBPMs,an automatic test system(ATS)has been developed in this article.Methods According to the test items of DBPM,the standardized testing softwareflow is designed based on virtual instru-ment program control technology and experimental physics and industrial control system(EPICS),which realize automatic adjustment of test parameters and automatic acquisition of test result data.Results and conclusions The ATS can realize one-button testing of channel coefficients,channel linearity,attenuator linearity,beam current dependence(BCD)and sampling signal-to-noise ratio(SNR),and generate test reports.The total test time is less than 3 minutes,which is significantly more efficient compared to manual testing.More than 90 BEPCII DBPMs has been tested by this ATS in the lab.The test results proved that such a system could automatically recognize defective products and satisfy the requirements of mass testing.展开更多
The beam diagnostic instrumentation for the Heifei Light Source (HLS)is described. It provides sufficient parameters for machine study during the commi-sioning and common operation. The measured results are presented.
为满足高能同步辐射光源(High Energy Photon Source,HEPS)束流位置测量的需求,研制了各种类型的束流位置探测器(Beam Position Monitor,BPM)。位置灵敏度系数是BPM的一项重要参数,通过它可以精确计算束流的位置。使用边界元法计算束流...为满足高能同步辐射光源(High Energy Photon Source,HEPS)束流位置测量的需求,研制了各种类型的束流位置探测器(Beam Position Monitor,BPM)。位置灵敏度系数是BPM的一项重要参数,通过它可以精确计算束流的位置。使用边界元法计算束流位置探测器的灵敏度系数,适用于在无法使用天线模拟束流进行实际测量和有限元软件进行模拟的场合。以HEPS储存环BPM的参数为例,首先用边界元法分析计算了具有圆形横截面的BPM的位置灵敏度系数,在此基础上,分析了椭圆形(HEPS增强器)与八边形(BEPCⅡ储存环)管道的系数。将该方法应用于BPM的设计与分析中,确定了高能光源增强器BPM纽扣电极的方位角和北京正负电子对撞机BPM的纽扣电极间距。此外,计算了上述BPM的位置灵敏度系数分布Mapping图。圆形管道BPM的位置灵敏度系数结果与解析值接近,相对误差在1%左右,椭圆形与八边形管道BPM的计算结果与实际测量结果的偏差都在2%左右,证明了边界元法计算束流位置探测器的位置灵敏度系数是一种可靠的方法,可用于BPM的设计与相关问题的分析。展开更多
基金supported by the National Natural Science Foundation of China(No.11605262)
文摘Significant temperature difference(300-77 K or even 4 K) can cause large deformations and displacements of the beam position monitors(BPMs),which affect BPMs measurement resolution or even cause their malfunction in cryogenic situations.In this paper,to check the offset from the mechanical to electrical center in low temperature(77 K),Fourier's law and finite element method are used to simulate cryo-deformation.Laser tracker and micro-alignment telescope are employed in combined BPM calibration,installation and monitoring.The calibration error is<0.02 mm,and the installation and monitoring precision are 0.06 mm and 0.01 mm,respectively.The monitored cryo-deformation agrees well with the simulation results.These indicate that the combined alignment can improve performance of the BPM system.All these guaranteed the success of running the 9.55 MeV@2.14 mA cw protons.
基金Supported by Project of Building a High-level University Well-known Both in China and in the World (KY2901), and Project of Hi-tech Research and Development Program of China (863-410-8-2)
文摘The parameters of beam transverse positions at HLS 200 MeV LINAC are very important to injection ef-ficiency. We have designed a new non-interceptive strip line beam position monitor (BPM) as a substitution for the original interceptive fluorescent target. This paper gives out the theoretical analysis and bench test result of the strip line BPM. The BPM has a characteristic impedance of (50±5)?, a reflection coefficient of less than –4 dB, a band-width of 400 MHz, a coupling coefficient of less than -15 dB, and a sensitivity of 1.16 dB/mm. Additionally, the strip line BPM has a good linearity.
基金Supported by National Natural Science Foundaion of China(No.11075198)
文摘In this paper,in order to achieve the output signal processing of cavity beam position monitor(CBPM),we develop a digital intermediate frequency receiver architecture based signal processing system,which consists of radio frequency(RF) front end and high speed data acquisition board.The beam position resolution in the CBPM signal processing system is superior to 1μm.Two signal processing algorithms,fast Fourier transform(FFT) and digital down converter(DDC),are evaluated offline using MATLAB platform,and both can be used to achieve,the CW input signal,position resolutions of 0.31μm and 0.10μm at -16 dBm.The DDC algorithm for its good compatibility is downloaded into the FPGA to realize online measurement,reaching the position resolution of 0.49μm due to truncation error.The whole system works well and the performance meets design target.
基金Supported by National Natural Science Foundation of China(No.11075198)
文摘Beam position monitors(BPMs)have been widely used in all kinds of measurement systems,feedback systems and other areas in particle accelerator field these days.The malfunction of a single BPM can cause serious consequences such as the failure of the orbit feedback and the transverse feedback.A troubleshooting has been made to prevent the defective BPMs from affecting the accuracy and stability of the storage ring in Shanghai Synchrotron Radiation Facility(SSRF).Different types of malfunctions have been successfully identified by using the idea of principal component analysis(PCA).
文摘The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.
基金Supported by National Natural Science Foundation of China(No.10675118,and No.11175173)
文摘In this paper,in order to stabilize the position and angle of the light source point,a new photon beam position feedback system based on the Photon Beam Position Monitors was developed on Hefei Light Source,and used to correct the position drift and angle variation of the light source at the same time.On introducing the feedback principle,the transfer function matrix is calibrated,indicating that the new system is workable and effective.
基金Ten Thousand Talent Program and Chinese Academy of Sciences Key Technology Talent Program (No.Y91G201B01)。
文摘Beam position monitors(BPMs)are important to monitor the beam moving steadily.Keeping the beam's normal motion is an important mission for Shanghai Synchrotron Radiation Facility.Effective diagnostic analysis is an important way to accomplish this task.This paper develops a new method based on clustering analysis to diagnose the healthy of BPMs with basic running data,i.e.,the β oscillation of X and Y directions and noise data.The analysis results showed that all beam position monitors(140 BPMs)can be classified into three groups:normal group,worse performance group,and fault group,respectively.In addition,the abnormal BPMs(including worse performance)could be marked.The new method showed its ability to handle faulty BPMs and it could instruct daily maintenance.On the other hand,it will be a useful supplement for data analysis in accelerator physics.
基金Supported by the National Science Foundation of China (10675118, 11175173)
文摘As an important part of the beam diagnostic system, the synchrotron light beam position measurement has a very high value in the high quality and high stability light source applied research. A new photon beam position monitor based on position-sensitive detector (PSD) has been developed to measure the photon beam position in vertical and horizontal directions at the same time at HLS (Hefei Light Source). The new PBPM based on the PSD has fast response speed, high sensitivity and wide dynamic range. This PBPM system also includes the C4674 signal processing circuit, NI USB-9215 data acquisition device and the LABVIEW data acquisition program. This PBPM system has been calibrated vertically and horizontally on-line, and then has been applied in the beam line B3EA of HLS to measure the position of the synchrotron light. As the results shown, the resolution of the system is better than 3 mm.
基金Supported by the Knowledge Innovation Program of the Chinese Academy of Sciences(No.KJCX2-YW-N27)National Natural Science Foundation of China(Nos.11205153 and 11175176)
文摘A fully digital beam position monitoring system(DBPM) has been designed for SSRF(Shanghai Synchrotron Radiation Facility). As analog-to-digital converter(ADC) is a crucial part in the DBPM system, the sampling methods should be studied to achieve optimum performance. Different sampling modes were used and compared through tests. Long term variation among four sampling channels, which would introduce errors in beam position measurement, is investigated. An interleaved distribution scheme was designed to address this issue. To evaluate the sampling methods, in-beam tests were conducted in SSRF. Test results indicate that with proper sampling methods, a turn-by-turn(TBT) position resolution better than 1 μm is achieved, and the slow-acquisition(SA) position resolution is improved from 4.28 μm to 0.17 μm.
基金funded by the Youth Innovation Promotion Association CAS(No.2019013 and Y202005)the National Natural Science Foundation of China(No.11975254).
文摘Purpose The absolute beam position measurement in the booster and storage ring of the high energy photon source(HEPS)requires the offset between the electrical and mechanical centers of the beam position monitor(BPM).Method Traditionally,an RF signal is sent to an antenna or stretched wire aligned with the vacuum chamber,and the signal at each electrode is measured.Conversely,a replacement method using a vector network analyzer,which was proposed by Lambertson,does not involve mechanical alignment and can be used for electrical offset determination.Results and conclusions The electro-mechanical offsets of booster BPMs of the HEPS were measured using the Lambertson method.The result shows good agreement with the stretched wire method within a 30μm error.
基金Supported by National Natural Science Foundation of China(11405240)"Western Light" Talents Training Program of Chinese Academy of Sciences
文摘Beam Position Monitors(BPMs) for the low-β beam of the Chinese Accelerator Driven Subcritical system(CADS) Proton linac are of the capacitive pick-up type.They provide higher output signals than that of the inductive type.This paper will describe the design and tests of the capacitive BPM system for the low-β proton linac,including the pick-ups,the test bench and the read-out electronics.The tests done with an actual proton beam show a good agreement between the measurements and the simulations in the time domain.
文摘In this paper, the 2-D electrostatic field software, POISSON, is used to calculate the characteristic impedance of a BPM (beam position monitor) for a high current proton linac. Furthermore, the time-domain 3-D module of MAFIA with a beam microbunch at a varying offset from the axis is used to compute the induced voltage on the electrodes as a function of time. Finally, the effect of low β beams on the induced voltage, the sensitivity and the signal dynamic range of the BPM are discussed.
基金Supported by National Natural Science Foundation of China(11175173,11375178,11105141)
文摘The new beam position monitor(BPM) system of the injector at the upgrade project of the Hefei Light Source(HLS II) has 19 stripline beam position monitors. Most consist of four orthogonally symmetric stripline electrodes. Differences in electronic gain and mismachining tolerance can cause changes in the beam response of the BPM electrodes. This variation will couple the two measured horizontal positions, resulting in measuring error. To alleviate this effect, a new technique to measure the relative response of the four electrodes has been developed. It is independent of the beam charge, and the related coefficient can be calculated theoretically. The effect of electrode coupling on this technique is analyzed. The calibration data is used to fit the gain for all 19 injector beam position monitors. The results show the standard deviation of the distribution of measured gains is about 5%.
基金funded by the Foundation ofYouth Innovation Promotion Association,CAS(No.Y202005)the Major achievements cultivation project of major scientific and technological infrastructure,CAS(No.NE01G74Y2)the National Natural Science Foundation of China(No.11805221).
文摘Purpose Hundreds of digital beam position monitor processors(DBPM)are required to be produced during the construction of projects such as High Energy Photon Source(HEPS)and the upgrade project of the Beijing Electron Positron Collider(BEPCII),which brings great challenges to the test work.In order to achieve accurate,fast,and complete mass production tests of DBPMs,an automatic test system(ATS)has been developed in this article.Methods According to the test items of DBPM,the standardized testing softwareflow is designed based on virtual instru-ment program control technology and experimental physics and industrial control system(EPICS),which realize automatic adjustment of test parameters and automatic acquisition of test result data.Results and conclusions The ATS can realize one-button testing of channel coefficients,channel linearity,attenuator linearity,beam current dependence(BCD)and sampling signal-to-noise ratio(SNR),and generate test reports.The total test time is less than 3 minutes,which is significantly more efficient compared to manual testing.More than 90 BEPCII DBPMs has been tested by this ATS in the lab.The test results proved that such a system could automatically recognize defective products and satisfy the requirements of mass testing.
文摘The beam diagnostic instrumentation for the Heifei Light Source (HLS)is described. It provides sufficient parameters for machine study during the commi-sioning and common operation. The measured results are presented.
文摘为满足高能同步辐射光源(High Energy Photon Source,HEPS)束流位置测量的需求,研制了各种类型的束流位置探测器(Beam Position Monitor,BPM)。位置灵敏度系数是BPM的一项重要参数,通过它可以精确计算束流的位置。使用边界元法计算束流位置探测器的灵敏度系数,适用于在无法使用天线模拟束流进行实际测量和有限元软件进行模拟的场合。以HEPS储存环BPM的参数为例,首先用边界元法分析计算了具有圆形横截面的BPM的位置灵敏度系数,在此基础上,分析了椭圆形(HEPS增强器)与八边形(BEPCⅡ储存环)管道的系数。将该方法应用于BPM的设计与分析中,确定了高能光源增强器BPM纽扣电极的方位角和北京正负电子对撞机BPM的纽扣电极间距。此外,计算了上述BPM的位置灵敏度系数分布Mapping图。圆形管道BPM的位置灵敏度系数结果与解析值接近,相对误差在1%左右,椭圆形与八边形管道BPM的计算结果与实际测量结果的偏差都在2%左右,证明了边界元法计算束流位置探测器的位置灵敏度系数是一种可靠的方法,可用于BPM的设计与相关问题的分析。