The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Gi...The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.展开更多
A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glip...A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.展开更多
In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoid...In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-O-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.展开更多
A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation ...A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile(60:40, v/v). Ciprofloxacin(CIPRO) was used as an internal standard. The analyte and internal standard(CIPRO) were monitored in the multiple reaction monitoring mode(MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision(relative standard deviation) and accuracy(relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.展开更多
通过固相萃取富集伏马菌素,采用液相色谱-电喷雾串联质谱法测定玉米和芦笋中的伏马菌素B1(FB1)、伏马菌素B2(FB2).在最佳色谱条件下,伏马菌素B1、伏马菌素B2的保留时间分别为5.2 min 和8.8 min,样品空白无干扰.离子化技术采用电喷雾正...通过固相萃取富集伏马菌素,采用液相色谱-电喷雾串联质谱法测定玉米和芦笋中的伏马菌素B1(FB1)、伏马菌素B2(FB2).在最佳色谱条件下,伏马菌素B1、伏马菌素B2的保留时间分别为5.2 min 和8.8 min,样品空白无干扰.离子化技术采用电喷雾正离子方式,以多反应监测(MRM)方式进行检测.该法检出限为80 pg;线性定量范围为0.01~10mg/L;回收率为78.3%~104.9%;相对标准偏差为2.2%~14.2%.利用ESI/MS/MS对伏马菌素B1、伏马菌素B2进行了质谱解析,分别选择特征离子峰m/z 352、528和m/z 336、512作为伏马菌素B1、伏马菌素B2准确定性的依据.方法灵敏度高,选择性好,准确度高,可为食品中伏马菌素的风险评估提供灵敏、准确的分析方法.展开更多
建立了鸡肉中3种氯霉素类抗生素残留的高效液相色谱 电喷雾电离三级四极杆质谱(HPLC ESI MS MS)测定法。该方法采用多反应监测(MRM)负离子模式,可一次对鸡肉中的氯霉素、甲砜霉素和氟甲砜霉素进行定性和定量。该方法仅需1g样品,并省去...建立了鸡肉中3种氯霉素类抗生素残留的高效液相色谱 电喷雾电离三级四极杆质谱(HPLC ESI MS MS)测定法。该方法采用多反应监测(MRM)负离子模式,可一次对鸡肉中的氯霉素、甲砜霉素和氟甲砜霉素进行定性和定量。该方法仅需1g样品,并省去固相萃取步骤,具有操作简便、有机试剂消耗量少、测定周期短等优点。方法的检出限为0 010μg/kg,测定低限为0 100μg/kg,线性范围为0 050~1 00μg/L,加标回收率为69 0%~92 8%,相对标准偏差为6 3%~12 9%。展开更多
文摘The ginkgo terpenoids including bilobalide and ginkgolides are the main pharmaceutical components in the leaves or extracts of Ginkgo biloba L. In this paper, the analysis of bilobalide and ginkgolides in leaves of Ginkgo biloba L. by high performance liquid chromatography (HPLC)-electrospray ionization (ESI)-mass spectrometry (MS) was carried out. The separation was performed on Inertsil ODS3 column with methanol-water (36:64) as mobile phase, with 1 mL·min -1 of flow rate at 35℃. Then the mass spectrum analysis was conducted by ZMD micromass electrospray ionization (ESI)-mass spectrometer (MS). The HPLC total ion chromatogram and selected ion chromatogram (with 325, 407, 423, 439 of m/z) of the sample and ESI-/MS mass spectra of the peaks in the chromatograms were obtained. So bilobalide, ginkgolide A, B, C and J in Ginkgo biloba L. leaves were identified. The method is easy and rapid, with a good accuracy.
文摘A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.
文摘In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-O-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.
文摘A rapid and sensitive liquid chromatography tandem mass spectrometry(LC-MS/MS) method has been developed and validated for the determination of moxifloxacin(MOXI) in human plasma. After a simple protein precipitation using acetonitrile, the post treatment samples were analysed on a C18 column interfaced with a Triple Quadropole Tandem Mass Spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of 0.1% formic acid–acetonitrile(60:40, v/v). Ciprofloxacin(CIPRO) was used as an internal standard. The analyte and internal standard(CIPRO) were monitored in the multiple reaction monitoring mode(MRM). The mass transition ion-pair has been followed as m/z 402→358.2 for MOXI and 332→288.1 for CIPRO. The method was linear in the concentration range of 25–5000 ng/mL. The lower limit of quantification was 25 ng/mL. The intra- and inter-day precision(relative standard deviation) and accuracy(relative error) values were within 12.4%. Each plasma sample was analyzed within 3 min.