This paper presents the characteristics of a double helix capacitance sensor for measurement of the liquid holdup in horizontal oil–water two-phase flow. The finite element method is used to calculate the sensitivity...This paper presents the characteristics of a double helix capacitance sensor for measurement of the liquid holdup in horizontal oil–water two-phase flow. The finite element method is used to calculate the sensitivity field of the sensor in a pipe with 20 mm inner diameter and the effect of sensor geometry on the distribution of sensitivity field is presented. Then, a horizontal oil–water two-phase flow experiment is carried out to measure the response of the double helix capacitance sensor, in which a novel method is proposed to calibrate the liquid holdup based on three pairs of parallel-wire capacitance probes. The performance of the sensor is analyzed in terms of the flow structures detected by mini-conductance array probes.展开更多
Zero net-liquid flow (ZNLF) is a special case of upward gas-liquid two-phase flow. It is a phenomenon observed as a gas-liquid mixture flows in a conduit but the net liquid flow rate is zero. Investigation on the liqu...Zero net-liquid flow (ZNLF) is a special case of upward gas-liquid two-phase flow. It is a phenomenon observed as a gas-liquid mixture flows in a conduit but the net liquid flow rate is zero. Investigation on the liquid holdup of ZNLF is conducted in a vertical ten-meter tube with diameter of 76 mm, both for Newtonian and nonNewtonian fluids. The gas phase is air. The Newtonian fluid is water and the non-Newtonian fluids are water-based guar gel solutions. The correlations developed for predicting liquid holdup on the basis of Lockhart-Martinelli parameter are not suitable to ZNLF. A constitutive correlation for the liquid holdup of vertical ZNLF was put forward by using the mass balance. It is found that the liquid holdup in ZNLF is dependent on both the gas flow rate and the flow distribution coefficient.展开更多
Accurate measurement of gas-liquid phase fraction is essential for the proper modelling of the pressure drop, heat transfer coefficient, mass transfer rate and interfacial area in two-phase flows. In this paper, takin...Accurate measurement of gas-liquid phase fraction is essential for the proper modelling of the pressure drop, heat transfer coefficient, mass transfer rate and interfacial area in two-phase flows. In this paper, taking the issue of optical distortion into account, an analytical model was proposed to estimate and correct the liquid holdup in gas-liquid annular flow through a circular pipe using high-speed camera method. The error in the liquid holdup measurement generated from different refractive indices among transparent circular pipe, liquid film and air core was firstly theoretically analyzed based on the geometric optics. Experimental tests were then carried out to identify the difference as well as to validate the proposed model. Results indicated that the prediction of the liquid holdup has a good performance with the experimental data(i.e., mean relative error is 4.1%) and the measured liquid holdup is larger than the real one. It was found that the measured liquid holdup is larger than the real one. Generally, when the real liquid holdup gets smaller, the discrepancy between the measured liquid holdup by image and the real liquid holdup becomes more significant. Thus, after measuring the liquid holdup from the images, the value of the measured liquid holdup must be corrected by the present model in order to obtain the real liquid holdup.展开更多
Axial and radial profiles of gas and solids holdups have been studied in agas-liquid-solid circulating fluidized bed at 140mm i.d..Experimental results indicate that the axialand radial profiles of gas and solids hold...Axial and radial profiles of gas and solids holdups have been studied in agas-liquid-solid circulating fluidized bed at 140mm i.d..Experimental results indicate that the axialand radial profiles of gas and solids holdups are more uniform than those in a conventionalfluidized bed.Axial and radial liquid dispersion coefficients in the gas-liquid-solid circulating fluidizedbed are investigated for the first time.It is found that axial and radial liquid dispersioncoefficients increases with increaes in gas velocity and solids holdup.The liquid velocity has littleinfluence on the axial liquid dispersion coefficient,but would adversely affect the redial liquiddispersion coefficient.It can be concluded that the gas-liquid-solid circulating fluidized bed hasadvantages such as better interphase contact and lower liquid dispersion along the axial directionover the expanded bed.展开更多
Rotor–stator reactor(RSR), an efficient mass transfer enhancer, has been applied in many fields. However,the hydrodynamic characteristics of liquid flow in RSR are still a mystery despite they are fundamental for the...Rotor–stator reactor(RSR), an efficient mass transfer enhancer, has been applied in many fields. However,the hydrodynamic characteristics of liquid flow in RSR are still a mystery despite they are fundamental for the mass transfer performance and processing capacity. In view of the above, this paper studies the liquid–liquid flow and liquid holdup in RSR under various conditions with a high-speed camera. The paper firstly demonstrates two flow patterns and liquid holdup patterns that we obtained from our experiment and then presents in succession a flow pattern and a liquid holdup criterion for the transition of film flow to filament flow and complete filling to incomplete filling. It is found that experimental parameters, including rotor–stator distance, rotational speed and volume flow rate exert great influence on the average droplet diameter and size distribution. Besides, by comparison and contrast, we also find that the experimental values match well with our previous predicted calculations of the average diameter, and the relation between the average diameter and the mean energy dissipation rate.展开更多
基金Supported by the National Natural Science Foundation of China(50974095,41174109,61104148)the National Science and Technology Major Projects(2011ZX05020-006)
文摘This paper presents the characteristics of a double helix capacitance sensor for measurement of the liquid holdup in horizontal oil–water two-phase flow. The finite element method is used to calculate the sensitivity field of the sensor in a pipe with 20 mm inner diameter and the effect of sensor geometry on the distribution of sensitivity field is presented. Then, a horizontal oil–water two-phase flow experiment is carried out to measure the response of the double helix capacitance sensor, in which a novel method is proposed to calibrate the liquid holdup based on three pairs of parallel-wire capacitance probes. The performance of the sensor is analyzed in terms of the flow structures detected by mini-conductance array probes.
文摘Zero net-liquid flow (ZNLF) is a special case of upward gas-liquid two-phase flow. It is a phenomenon observed as a gas-liquid mixture flows in a conduit but the net liquid flow rate is zero. Investigation on the liquid holdup of ZNLF is conducted in a vertical ten-meter tube with diameter of 76 mm, both for Newtonian and nonNewtonian fluids. The gas phase is air. The Newtonian fluid is water and the non-Newtonian fluids are water-based guar gel solutions. The correlations developed for predicting liquid holdup on the basis of Lockhart-Martinelli parameter are not suitable to ZNLF. A constitutive correlation for the liquid holdup of vertical ZNLF was put forward by using the mass balance. It is found that the liquid holdup in ZNLF is dependent on both the gas flow rate and the flow distribution coefficient.
基金the National Natural Science Foundation of China(No.51276140)
文摘Accurate measurement of gas-liquid phase fraction is essential for the proper modelling of the pressure drop, heat transfer coefficient, mass transfer rate and interfacial area in two-phase flows. In this paper, taking the issue of optical distortion into account, an analytical model was proposed to estimate and correct the liquid holdup in gas-liquid annular flow through a circular pipe using high-speed camera method. The error in the liquid holdup measurement generated from different refractive indices among transparent circular pipe, liquid film and air core was firstly theoretically analyzed based on the geometric optics. Experimental tests were then carried out to identify the difference as well as to validate the proposed model. Results indicated that the prediction of the liquid holdup has a good performance with the experimental data(i.e., mean relative error is 4.1%) and the measured liquid holdup is larger than the real one. It was found that the measured liquid holdup is larger than the real one. Generally, when the real liquid holdup gets smaller, the discrepancy between the measured liquid holdup by image and the real liquid holdup becomes more significant. Thus, after measuring the liquid holdup from the images, the value of the measured liquid holdup must be corrected by the present model in order to obtain the real liquid holdup.
文摘Axial and radial profiles of gas and solids holdups have been studied in agas-liquid-solid circulating fluidized bed at 140mm i.d..Experimental results indicate that the axialand radial profiles of gas and solids holdups are more uniform than those in a conventionalfluidized bed.Axial and radial liquid dispersion coefficients in the gas-liquid-solid circulating fluidizedbed are investigated for the first time.It is found that axial and radial liquid dispersioncoefficients increases with increaes in gas velocity and solids holdup.The liquid velocity has littleinfluence on the axial liquid dispersion coefficient,but would adversely affect the redial liquiddispersion coefficient.It can be concluded that the gas-liquid-solid circulating fluidized bed hasadvantages such as better interphase contact and lower liquid dispersion along the axial directionover the expanded bed.
基金Supported by the National Natural Science Foundation of China(21776180,21776181,21306116)Hou Hua Ku Project of Sichuan University(2018SCUH0012).
文摘Rotor–stator reactor(RSR), an efficient mass transfer enhancer, has been applied in many fields. However,the hydrodynamic characteristics of liquid flow in RSR are still a mystery despite they are fundamental for the mass transfer performance and processing capacity. In view of the above, this paper studies the liquid–liquid flow and liquid holdup in RSR under various conditions with a high-speed camera. The paper firstly demonstrates two flow patterns and liquid holdup patterns that we obtained from our experiment and then presents in succession a flow pattern and a liquid holdup criterion for the transition of film flow to filament flow and complete filling to incomplete filling. It is found that experimental parameters, including rotor–stator distance, rotational speed and volume flow rate exert great influence on the average droplet diameter and size distribution. Besides, by comparison and contrast, we also find that the experimental values match well with our previous predicted calculations of the average diameter, and the relation between the average diameter and the mean energy dissipation rate.