The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level ne...The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.展开更多
Many kinds of high temperature superconductor (HTS) power machines such as HTS cable, HTS fault current limitcr and HTS magnet are cooled by liquid nitrogen. The level of liquid nitrogen should be monitored and cont...Many kinds of high temperature superconductor (HTS) power machines such as HTS cable, HTS fault current limitcr and HTS magnet are cooled by liquid nitrogen. The level of liquid nitrogen should be monitored and controlled to ensure the thermal stability and the dielectric strength as well. To measure the level, capacitance method and differential pressure method are usually used. However, each method has installation difficulties and measurement errors for unsteady state operation with varying system pressure. A new liquid level meter using a 2G HTS conductor is described, which has similar structure with the liquid helium level meter with NbTi filament. The level meter is fabricated with a parallel connected heater, which helps the separation of the superconducting region and normal region, considering the critical temperature, large heat capacity of conductor and cooling characteristics. The level of liquid nitrogen can be obtained from the measured voltage signal along the 2G HTS conductor. Design, fabrication and test results of the new liquid nitrogen level meter are presented.展开更多
基金Supported by National Science Foundation of China(11055003,11175117)Science and Technology Commission of Shanghai Municipality(11PJ1405300)Ministry of Science and Technology of China(2010CB833005)
文摘The two-phase xenon detector is at the frontier of dark matter direct search. This kind of detector uses liquid xenon as the sensitive target and is operated in two-phase (liquid/gas) mode, where the liquid level needs to be monitored and controlled in sub-millimeter precision. In this paper, we present a detailed design and study of two kinds of level meters for the PandaX dark matter detector. The long level meter is used to monitor the overall liquid level while short level meters are used to monitor the inclination of the detector. These level meters are cylindrical capacitors that are custom-made from two concentric metal tubes. Their capacitance values are read out by a universal transducer interface chip and are recorded by the PandaX slow control system. We present the developments that lead to level meters with long-term stability and sub-millimeter precision. Fluctuations (standard deviations) of less than 0.02 mm for the short level meters and less than 0.2 mm for the long level meter were achieved during a few days of test operation.
基金Project supported by the Second Stage of Brain Korea 21 Projects
文摘Many kinds of high temperature superconductor (HTS) power machines such as HTS cable, HTS fault current limitcr and HTS magnet are cooled by liquid nitrogen. The level of liquid nitrogen should be monitored and controlled to ensure the thermal stability and the dielectric strength as well. To measure the level, capacitance method and differential pressure method are usually used. However, each method has installation difficulties and measurement errors for unsteady state operation with varying system pressure. A new liquid level meter using a 2G HTS conductor is described, which has similar structure with the liquid helium level meter with NbTi filament. The level meter is fabricated with a parallel connected heater, which helps the separation of the superconducting region and normal region, considering the critical temperature, large heat capacity of conductor and cooling characteristics. The level of liquid nitrogen can be obtained from the measured voltage signal along the 2G HTS conductor. Design, fabrication and test results of the new liquid nitrogen level meter are presented.