A novel process to recovery natural gas liquids from oil field associated gas with liquefied natural gas (LNG)cryogenic energy utilization is proposed.Compared to the current electric refrigeration process,the propose...A novel process to recovery natural gas liquids from oil field associated gas with liquefied natural gas (LNG)cryogenic energy utilization is proposed.Compared to the current electric refrigeration process,the proposed process uses the cryogenic energy of LNG and saves 62.6%of electricity.The proposed process recovers ethane, liquid petroleum gas(propane and butane)and heavier hydrocarbons,with total recovery rate of natural gas liquids up to 96.8%.In this paper,exergy analysis and the energy utilization diagram method(EUD)are used to assess the new process and identify the key operation units with large exergy loss.The results show that exergy efficiency of the new process is 44.3%.Compared to the electric refrigeration process,exergy efficiency of the new process is improved by 16%.The proposed process has been applied and implemented in a conceptual design scheme of the cryogenic energy utilization for a 300 million tons/yr LNG receiving terminal in a northern Chinese harbor.展开更多
This article presents a device for the storage and gasification of cryogenic working fluid,which is named a cryogenic fuelling tank.A cryogenic fuel tank can serve both as a fuel vessel and a pressure accumulator due ...This article presents a device for the storage and gasification of cryogenic working fluid,which is named a cryogenic fuelling tank.A cryogenic fuel tank can serve both as a fuel vessel and a pressure accumulator due to the regasification process that takes place inside.Application of this tank is slowed by the lack of theoretical and experimental research on its working process.This article deals with an investigation of the working process of the energy plant based on a cryogenic fuel tank coupled with a rotor-vane expander.Developed mathematical models include evaporation and condensation processes within the tank,heat exchange between gas chambers and between the tank and environment,and changes in energy due to incoming and leaving mass.Mechanical work used to determine the efficiency of a power plant is generated by a steam expander.Research shows that it is possible to achieve specific work outputs up to 110-160 kJ/kg with relative deviation of power and specific work determination equal to 1.4% and 1.9%correspondingly.展开更多
基金Supported by the National Natural Science Foundation of China(20876056,20536020)the PhD Program Fund from Ministry of Education of China(20100172110016)
文摘A novel process to recovery natural gas liquids from oil field associated gas with liquefied natural gas (LNG)cryogenic energy utilization is proposed.Compared to the current electric refrigeration process,the proposed process uses the cryogenic energy of LNG and saves 62.6%of electricity.The proposed process recovers ethane, liquid petroleum gas(propane and butane)and heavier hydrocarbons,with total recovery rate of natural gas liquids up to 96.8%.In this paper,exergy analysis and the energy utilization diagram method(EUD)are used to assess the new process and identify the key operation units with large exergy loss.The results show that exergy efficiency of the new process is 44.3%.Compared to the electric refrigeration process,exergy efficiency of the new process is improved by 16%.The proposed process has been applied and implemented in a conceptual design scheme of the cryogenic energy utilization for a 300 million tons/yr LNG receiving terminal in a northern Chinese harbor.
基金using the equipment of the Research Educational Center“REC-Vibration Strengthand Reliability of Aerospace Products”with financial support from the Ministry of Science and Higher Education of the Russian Federation(Project No FSSS-2024-0017).
文摘This article presents a device for the storage and gasification of cryogenic working fluid,which is named a cryogenic fuelling tank.A cryogenic fuel tank can serve both as a fuel vessel and a pressure accumulator due to the regasification process that takes place inside.Application of this tank is slowed by the lack of theoretical and experimental research on its working process.This article deals with an investigation of the working process of the energy plant based on a cryogenic fuel tank coupled with a rotor-vane expander.Developed mathematical models include evaporation and condensation processes within the tank,heat exchange between gas chambers and between the tank and environment,and changes in energy due to incoming and leaving mass.Mechanical work used to determine the efficiency of a power plant is generated by a steam expander.Research shows that it is possible to achieve specific work outputs up to 110-160 kJ/kg with relative deviation of power and specific work determination equal to 1.4% and 1.9%correspondingly.