One-dimensional ring power system is discredited to a number of nodes each containing a generator with internal reactance and load branch of resistance and reactance with a certain power factor. When a disturbance occ...One-dimensional ring power system is discredited to a number of nodes each containing a generator with internal reactance and load branch of resistance and reactance with a certain power factor. When a disturbance occurs at any machine in the power system, simulative analysis is performed to verify how the variation of load power factor affecting the behavior of electromechanical wave propagation by using the MATLAB package, from which different situations are presented and discussed. These results show the type of load has no effect on the behavior of electromechanical wave propagation.展开更多
The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unba...The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unbalance loading are investigated simultaneously for electrical railway systems. Special traction transformers (i.e. single-phase, V/V, Wye-Delta, Scott, and Le Blanc) are used between the utility grid and the traction load. For analysis, different defini-tions of power factors are considered, which are presented by IEEE Std.1459. The detailed simulation study is made with MATLAB/SIMULINK program to represent the impacts of harmonic components and unbalance loading on the power factor behavior in the Electrical Railway systems.展开更多
Power factor correction is a major issue for all industries, since a typical industrial load is causing current delays, as well as higher order current harmonics. Power factor correction is often mandatory from the po...Power factor correction is a major issue for all industries, since a typical industrial load is causing current delays, as well as higher order current harmonics. Power factor correction is often mandatory from the power companies, usually by charging the reactive power that the company consumes. Many solutions for power factor correction have been presented in the bibliography;in this paper, the most significant power factor correction topologies will be reviewed and simulated with SABER RD software. Finally, a prototype design will be presented, based on a mass/cost analysis of the selected topologies and with an aim to manufacture 10 kW modules. The main outcome of this work is the feasibility for an SME to manufacture a competitive modular power factor correction product for industrial applications.展开更多
A magnetohydrodynamic (MHD) power generator system involves several subjects such as magnetohydrodynamics, plasma physics, material science, and structure mechanics. Therefore, the performance of the MHD power gener...A magnetohydrodynamic (MHD) power generator system involves several subjects such as magnetohydrodynamics, plasma physics, material science, and structure mechanics. Therefore, the performance of the MHD power generator is affected by many factors, among which the load coefficient k is of great importance. This paper reveals the effect of some system parameters on the performance by three-dimensional (3D) numerical simulation for a Faraday type MHD power generator using He/Xe as working plasma. The results show that average electrical conductivity increases first and then decreases with the addition of magnetic field intensity. Electrical conductivity reaches the maximum value of 11.05 S/m, while the applied magnetic field strength is B = 1.75 T. When B 〉 3 T, the ionization rate along the midline well keeps stable, which indicates that the ionization rate and three-body recombination rate (three kinds of particles combining to two kinds of particles) are approximately equal, and the relatively stable plasma structure of the mainstream is preserved. Efficiency of power generation of the Faraday type channel increases with an increment of the load factor. However, enthalpy extraction first increases to a certain value, and then decreases with the load factor. The enthalpy extraction rate reaches the maximum when the load coefficient k equals 0.625, which is the best performance of the power generator channel with the maximum electricity production.展开更多
When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor...When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor current mode. To solve this problem, this paper proposes a PFC control system, which can operate with load fluctuations up to 1 000 W by using duty cycle feed-forward control theory to achieve smooth switching mode. The duty cycles in the next period of the control system are pre-estimated in the current cycle, which enhances the speeds of AD samplers and switching frequency, and reduces the cost and volume of the equipment to some extent. Introductions of system decoupling and feed-forward of input-voltage greatly improve the system performance. Both theoretical simulation and experimental results prove the advantage of the proposed scheme.展开更多
文摘One-dimensional ring power system is discredited to a number of nodes each containing a generator with internal reactance and load branch of resistance and reactance with a certain power factor. When a disturbance occurs at any machine in the power system, simulative analysis is performed to verify how the variation of load power factor affecting the behavior of electromechanical wave propagation by using the MATLAB package, from which different situations are presented and discussed. These results show the type of load has no effect on the behavior of electromechanical wave propagation.
文摘The single-phase traction load has essentially an unbalance characteristic at the Point of Common Coupling (PCC), which injects harmonic into the utility grid. In this paper, the effect of harmonic distortion and unbalance loading are investigated simultaneously for electrical railway systems. Special traction transformers (i.e. single-phase, V/V, Wye-Delta, Scott, and Le Blanc) are used between the utility grid and the traction load. For analysis, different defini-tions of power factors are considered, which are presented by IEEE Std.1459. The detailed simulation study is made with MATLAB/SIMULINK program to represent the impacts of harmonic components and unbalance loading on the power factor behavior in the Electrical Railway systems.
文摘Power factor correction is a major issue for all industries, since a typical industrial load is causing current delays, as well as higher order current harmonics. Power factor correction is often mandatory from the power companies, usually by charging the reactive power that the company consumes. Many solutions for power factor correction have been presented in the bibliography;in this paper, the most significant power factor correction topologies will be reviewed and simulated with SABER RD software. Finally, a prototype design will be presented, based on a mass/cost analysis of the selected topologies and with an aim to manufacture 10 kW modules. The main outcome of this work is the feasibility for an SME to manufacture a competitive modular power factor correction product for industrial applications.
基金Project supported by the National Defense Basic Scientific Research Program of China(No.JCKY2013203B003)
文摘A magnetohydrodynamic (MHD) power generator system involves several subjects such as magnetohydrodynamics, plasma physics, material science, and structure mechanics. Therefore, the performance of the MHD power generator is affected by many factors, among which the load coefficient k is of great importance. This paper reveals the effect of some system parameters on the performance by three-dimensional (3D) numerical simulation for a Faraday type MHD power generator using He/Xe as working plasma. The results show that average electrical conductivity increases first and then decreases with the addition of magnetic field intensity. Electrical conductivity reaches the maximum value of 11.05 S/m, while the applied magnetic field strength is B = 1.75 T. When B 〉 3 T, the ionization rate along the midline well keeps stable, which indicates that the ionization rate and three-body recombination rate (three kinds of particles combining to two kinds of particles) are approximately equal, and the relatively stable plasma structure of the mainstream is preserved. Efficiency of power generation of the Faraday type channel increases with an increment of the load factor. However, enthalpy extraction first increases to a certain value, and then decreases with the load factor. The enthalpy extraction rate reaches the maximum when the load coefficient k equals 0.625, which is the best performance of the power generator channel with the maximum electricity production.
基金Supported by the National Basic Research Program of China("973"Program,No.2009CB219700)
文摘When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor current mode. To solve this problem, this paper proposes a PFC control system, which can operate with load fluctuations up to 1 000 W by using duty cycle feed-forward control theory to achieve smooth switching mode. The duty cycles in the next period of the control system are pre-estimated in the current cycle, which enhances the speeds of AD samplers and switching frequency, and reduces the cost and volume of the equipment to some extent. Introductions of system decoupling and feed-forward of input-voltage greatly improve the system performance. Both theoretical simulation and experimental results prove the advantage of the proposed scheme.