This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of i...This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.展开更多
Excess wind power produced in wind-inten- sive areas is normally delivered to remote load centers via long-distance transmission lines. This paper presents a comparison between long-distance transmission, which has ga...Excess wind power produced in wind-inten- sive areas is normally delivered to remote load centers via long-distance transmission lines. This paper presents a comparison between long-distance transmission, which has gained popularity, and local energy consumption, in which a fraction of the generated wind power can be locally consumed by energy-intensive industries. First, the challenges and solutions to the long-distance transmission and local consumption of wind power are presented. Then, the two approaches to the utilization of wind power are compared in terms of system security, reliability, cost, and capability to utilize wind energy. Finally, the economic feasibility and technical feasibility of the local consumption of wind power are demonstrated by a large and isolated industrial power system, or supermicrogrid, in China. The coal-fired generators together with the shortterm interruptible electrolytic aluminum load in the supermicrogrid are able to compensate for the intermit- tency of wind power. In the long term, the transfer of high- energy-consumption industries to wind-rich areas and their local consumption of the available wind power are beneficial.展开更多
远距离海上风电越来越多地选择柔性直流经海缆送出的方式。采用电缆的柔性直流(voltage source converter based high voltage direct current,VSC-HVDC)输电系统,其故障特性比传统架空线直流输电系统更加复杂。文中基于对称单极拓扑的...远距离海上风电越来越多地选择柔性直流经海缆送出的方式。采用电缆的柔性直流(voltage source converter based high voltage direct current,VSC-HVDC)输电系统,其故障特性比传统架空线直流输电系统更加复杂。文中基于对称单极拓扑的双端VSC-HVDC海上风电送出工程,简化了电缆和VSC-HVDC输电系统的数学模型,分析换流变阀侧交流系统单相接地和直流电缆线路单极接地等典型故障下的故障特性,运用叠加原理对故障机理进行解释;根据不同故障类型的故障源等效出不同的故障回路,得到了长距离电缆显著的电容效应对VSC-HVDC系统故障特征的复杂影响;利用实时数字仿真平台,搭建远海风电送出系统硬件在环仿真模型,验证了故障机理解析分析的正确性。展开更多
基金supported by Creative Challenge Research Program (2021R1I1A1A01052521)the BK-21 FOUR program through the National Research Foundation of Korea (NRF)under the Ministry of Education.
文摘This paper presents a performance analysis of novel doubledampedtuned alternating current (AC) filters in high voltage direct current(HVDC) systems. The proposed double-damped tuned AC filters offer theadvantages of improved performance of HVDC systems in terms of betterpower quality, high power factor, and lower total harmonic distortion (THD).The system under analysis consists of an 878 km long HVDC transmissionline connecting converter stations at Matiari and Lahore, two major cities inPakistan. The main focus of this research is to design a novel AC filter usingthe equivalent impedance method of two single-tuned and double-dampedtuned AC filters. Additionally, the impact of the damping resistor on the ACchannel is examined. TheTHDof theHVDCsystem with and without currentAC filters was also compared in this research and a double-damped tuned ACfilter was proposed. The results of the simulation represent that the proposeddouble-damped tuned AC filter is far smaller in size, offers better powerquality, and has a much lower THD compared to the AC filters currently inplace in the converter station. The simulation analysis was carried out utilizingpower systems computer-aided design (PSCAD) software.
基金This work was supported in part by the Ministry of Science and Technology of China (Grant No. 2016YFB0900105) and the National Natural Science Foundation of China (Grant Nos. 51190105 and 51477122).
文摘Excess wind power produced in wind-inten- sive areas is normally delivered to remote load centers via long-distance transmission lines. This paper presents a comparison between long-distance transmission, which has gained popularity, and local energy consumption, in which a fraction of the generated wind power can be locally consumed by energy-intensive industries. First, the challenges and solutions to the long-distance transmission and local consumption of wind power are presented. Then, the two approaches to the utilization of wind power are compared in terms of system security, reliability, cost, and capability to utilize wind energy. Finally, the economic feasibility and technical feasibility of the local consumption of wind power are demonstrated by a large and isolated industrial power system, or supermicrogrid, in China. The coal-fired generators together with the shortterm interruptible electrolytic aluminum load in the supermicrogrid are able to compensate for the intermit- tency of wind power. In the long term, the transfer of high- energy-consumption industries to wind-rich areas and their local consumption of the available wind power are beneficial.
文摘远距离海上风电越来越多地选择柔性直流经海缆送出的方式。采用电缆的柔性直流(voltage source converter based high voltage direct current,VSC-HVDC)输电系统,其故障特性比传统架空线直流输电系统更加复杂。文中基于对称单极拓扑的双端VSC-HVDC海上风电送出工程,简化了电缆和VSC-HVDC输电系统的数学模型,分析换流变阀侧交流系统单相接地和直流电缆线路单极接地等典型故障下的故障特性,运用叠加原理对故障机理进行解释;根据不同故障类型的故障源等效出不同的故障回路,得到了长距离电缆显著的电容效应对VSC-HVDC系统故障特征的复杂影响;利用实时数字仿真平台,搭建远海风电送出系统硬件在环仿真模型,验证了故障机理解析分析的正确性。