Based on tests and theoretical calculation an optimum steam admission mode is proposed which can effectively solve the steam-excited vibration.An operation mode jointly considering the valve point and operation load i...Based on tests and theoretical calculation an optimum steam admission mode is proposed which can effectively solve the steam-excited vibration.An operation mode jointly considering the valve point and operation load is proposed based on the analysis and study of a large number of unit operation optimization methods.According to the steam-excited vibration that occurs during the optimization process when the nozzle governing steam turbine switches from a single valve to multi-valves a steam admission optimization program is proposed.This comprehensive program considering the steam-excited vibration is applied to a 600 MW steam turbine unit to obtain the optimum sliding pressure curve and the optimum operation mode and the steam-excited vibration is solved successfully.展开更多
In this paper,we investigate sufficient and necessary conditions such that generalized Forelli-Rudin type operators T_(λ,τ,k),S_(λ,τ,k),Q_(λ,τ,k)and R_(λ,τ,k)are bounded between Lebesgue type spaces.In order t...In this paper,we investigate sufficient and necessary conditions such that generalized Forelli-Rudin type operators T_(λ,τ,k),S_(λ,τ,k),Q_(λ,τ,k)and R_(λ,τ,k)are bounded between Lebesgue type spaces.In order to prove the main results,we first give some bidirectional estimates for several typical integrals.展开更多
Production planning models generated by common modeling systems do not involve constraints for process operations, and a solution optimized by these models is called a quasi-optimal plan. The quasi-optimal plan cannot...Production planning models generated by common modeling systems do not involve constraints for process operations, and a solution optimized by these models is called a quasi-optimal plan. The quasi-optimal plan cannot be executed in practice some time for no corresponding operating conditions. In order to determine a practi- cally feasible optimal plan and corresponding operating conditions of fluidized catalytic cracking unit (FCCU), a novel close-loop integrated strategy, including determination of a quasi-optimal plan, search of operating conditions of FCCU and revision of the production planning model, was proposed in this article. In the strategy, a generalized genetic algorithm (GA) coupled with a sequential process simulator of FCCU was applied to search operating conditions implementing the quasi-optimal plan of FCCU and output the optimal individual in the GA search as a final genetic individual. When no corresponding operating conditions were found, the final genetic individual based correction (FGIC) method was presented to revise the production planning model, and then a new quasi-optimal production plan was determined. The above steps were repeated until a practically feasible optimal plan and corresponding operating conditions of FCCU were obtained. The close-loop integrated strategy was validated by two cases, and it was indicated that the strategy was efficient in determining a practically executed optimal plan and corresponding operating conditions of FCCU.展开更多
Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running...Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...展开更多
There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas incre...There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas increases,which will lead to fouling,erosion and plugging of downstream equipment. In this study,the main effects of SO_3 on the safety,stability and efficiency of units were analyzed,and measures to control SO_3 were proposed.展开更多
Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on f...Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on four types of agar media and incubated at 25℃. Forty-five fungal species representing 23 genera were isolated and identified. The most prevalent genera recorded were Cladosporium, Aspergillus, Penicillium and Fusarium. The total colony forming units of airborne fungi recovered in I.C.U. and O.R. ranged between 31.13-49.61 colonies/m3 on the four types of media usedl The fungal total catch of the dust samples collected from the air conditioning system filters in I.C.U. and O.R. were ranged from 65.5-170 colonies/mg dust. Since, the interest to replace synthetic xenobiotics by natural compounds with low environmental persistence and biodegradable to control such airborne fungal contaminants is needed. In this respect, essential oils showed to possess a broad spectrum of antifungal activity. Fungal static ability of six oils was tested on 30 different fungal isolates. Vapors of common thyme oil exhibited the strongest inhibitory effects on the tested isolates, whereas the headspace vapors of blue gum and ginger had no inhibitory effects on the tested fungal isolates. These data revealed that the air conditioning systems may be an important source of contamination in I.C.U. and O.R. of Assiut university hospitals. Thus, patients may be in risk of being exposed to contaminated atmospheric air by opportunistic fungi and the use of essential oils as an alternative option to control hospital wards from fungal contaminants needs further studies.展开更多
This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009.The units brought into the statistical analysis include 100-MW or abov...This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009.The units brought into the statistical analysis include 100-MW or above thermal generating units,40-MW or above hydro generating units,and all nuclear generating units.The reliability indices embodied include utilization hours,times and hours of scheduled outages,times and hours of unscheduled outages,equivalent forced outage rate and equivalent availability factor.展开更多
On December 25, 2009, after the 72-hour trail operation, Unit 2 of Laxiwa Hydropower Station on the Yellow River, constructed by CPI Yellow River Hydropower Corporation, was formally
In the process of designing a municipal rainwater and sewage pumping station,it is necessary to accurately grasp the design points,reasonably determine the scale of the rainwater and sewage pumping station,scientifica...In the process of designing a municipal rainwater and sewage pumping station,it is necessary to accurately grasp the design points,reasonably determine the scale of the rainwater and sewage pumping station,scientifically select the location and layout,and select materials reasonably.After completing the process design of the municipal rainwater and sewage pumping station and putting it into operation,in order to ensure the normal and stable operation of the pumping station,it is necessary to focus on strengthening the operation and management of diving equipment,cleaning equipment,and electromechanical equipment.The author analyzes the key points and specific design path of the process design of municipal rainwater and sewage pumping stations,and puts forward effective strategies for operation management,hoping to contribute to the scientific design and stable operation of municipal rainwater and sewage pumping stations.展开更多
Coal preparation is an integral part of the coal commodity supply chain. This stage of post-mining, pre-utilization beneficiation uses low-cost separation technologies to remove unwanted mineral matter and moisture wh...Coal preparation is an integral part of the coal commodity supply chain. This stage of post-mining, pre-utilization beneficiation uses low-cost separation technologies to remove unwanted mineral matter and moisture which hinder the value of the coal product. Coal preparation plants typically employ several parallel circuits of cleaning and dewatering operations, with each circuit designed to optimally treat a specific size range of coal. Recent innovations in coal preparation have increased the efficiency and capac- ity of individual unit operations while reinforcing the standard parallel cleaning approach. This article, which describes the historical influences and state-of-the-art design for the various coal preparation unit operations, is organized to distinguish between coarse/intermediate coal cleaning and fine/ultrafine coal cleaning. Size reduction, screening, classification, cleaning, dewatering, waste disposal unit operations are particularly highlighted, with a special focus on the LI.S. design philosophy. Notable differences between the U.S. and international operations are described as appropriate.展开更多
Operation optimization is an effective method to explore potential economic benefits for existing plants. The m.aximum potential benefit from operationoptimization is determined by the distances between current operat...Operation optimization is an effective method to explore potential economic benefits for existing plants. The m.aximum potential benefit from operationoptimization is determined by the distances between current operating point and process constraints, which is related to the margins of design variables. Because of various ciisturbances in chemical processes, some distances must be reserved for fluctuations of process variables and the optimum operating point is not on some process constraints. Thus the benefit of steady-state optimization can not be fully achied(ed while that of dynamic optimization can be really achieved. In this study, the steady-state optimizationand dynamic optimization are used, and the potential benefit-is divided into achievable benefit for profit and unachievable benefit for control. The fluid catalytic cracking unit (FCCU) is used for case study. With the analysis on how the margins of design variables influence the economic benefit and control performance, the bottlenecks of process design are found and appropriate control structure can be selected.展开更多
This paper deals with the boundedness and compactness of the weighted composition operators from the F(p, q, s) spaces, including Hardy space, Bergman space, Qp space, BMOA space, Besov space and α-Bloch space, to ...This paper deals with the boundedness and compactness of the weighted composition operators from the F(p, q, s) spaces, including Hardy space, Bergman space, Qp space, BMOA space, Besov space and α-Bloch space, to Bers-type spaces Hv^∞( or little Bers-type spaces Hv,o∞ ), where v is normal.展开更多
In this paper we mainly consider little Hankel operators with squareintegrable symbols on the weighted Bergman spaces of the unit ball.We obtain that Schatten class of little Hankel operators is equivalent to Schatten...In this paper we mainly consider little Hankel operators with squareintegrable symbols on the weighted Bergman spaces of the unit ball.We obtain that Schatten class of little Hankel operators is equivalent to Schatten class of positive Toeplitz operators under the conditions that SMO(f) ∈ L p/2 (B n,dλ) and 2 ≤ p ∞,which is very important to research the relation between Toeplitz operators and little Hankel operators.展开更多
基金The National Natural Science Foundation of China(No.51176031)
文摘Based on tests and theoretical calculation an optimum steam admission mode is proposed which can effectively solve the steam-excited vibration.An operation mode jointly considering the valve point and operation load is proposed based on the analysis and study of a large number of unit operation optimization methods.According to the steam-excited vibration that occurs during the optimization process when the nozzle governing steam turbine switches from a single valve to multi-valves a steam admission optimization program is proposed.This comprehensive program considering the steam-excited vibration is applied to a 600 MW steam turbine unit to obtain the optimum sliding pressure curve and the optimum operation mode and the steam-excited vibration is solved successfully.
基金supported by the Natural Science Foundation of Hunan Province of China(2022JJ30369)the Education Department Important Foundation of Hunan Province in China(23A0095)。
文摘In this paper,we investigate sufficient and necessary conditions such that generalized Forelli-Rudin type operators T_(λ,τ,k),S_(λ,τ,k),Q_(λ,τ,k)and R_(λ,τ,k)are bounded between Lebesgue type spaces.In order to prove the main results,we first give some bidirectional estimates for several typical integrals.
文摘Production planning models generated by common modeling systems do not involve constraints for process operations, and a solution optimized by these models is called a quasi-optimal plan. The quasi-optimal plan cannot be executed in practice some time for no corresponding operating conditions. In order to determine a practi- cally feasible optimal plan and corresponding operating conditions of fluidized catalytic cracking unit (FCCU), a novel close-loop integrated strategy, including determination of a quasi-optimal plan, search of operating conditions of FCCU and revision of the production planning model, was proposed in this article. In the strategy, a generalized genetic algorithm (GA) coupled with a sequential process simulator of FCCU was applied to search operating conditions implementing the quasi-optimal plan of FCCU and output the optimal individual in the GA search as a final genetic individual. When no corresponding operating conditions were found, the final genetic individual based correction (FGIC) method was presented to revise the production planning model, and then a new quasi-optimal production plan was determined. The above steps were repeated until a practically feasible optimal plan and corresponding operating conditions of FCCU were obtained. The close-loop integrated strategy was validated by two cases, and it was indicated that the strategy was efficient in determining a practically executed optimal plan and corresponding operating conditions of FCCU.
基金Supported by National Natural Science Foundation of China (No. 50578048)"Heating, Gas, Ventilation and Air Conditioning" Key Laboratory Open Subject in Beijing (No. KF200710)the Postdoctoral Researcher Science Foundation of China (No. 20090450986)
文摘Sewage source heat pump unit operates under partial load most of the time, and study on the law of coefficient of performance (COP) of the unit varying with load ratio can provide basis for the heat pump units running in high efficiency. A mathematical model determining COP, evaporation temperature and condensation temperature of a single unit was proposed. Under the condition of uniform load distribution, the model was established according to different ways of bearing partial load with the same type multi...
基金Supported by National High Technology Research and Development Program of China(863 Program)(2013AA065401)
文摘There exists a certain amount of SO_3 in flue gas discharged from coal-fired power plants. With the operation of the selective catalystic reduction( SCR) denitrification system,SO_3 concentration in the flue gas increases,which will lead to fouling,erosion and plugging of downstream equipment. In this study,the main effects of SO_3 on the safety,stability and efficiency of units were analyzed,and measures to control SO_3 were proposed.
文摘Mycoflora of atmospheric air and dust samples collected from air conditioning systems in 12 of each I.C.U. (intensive care units) and O.R. (operation rooms) were tested using settle and dilution plate methods on four types of agar media and incubated at 25℃. Forty-five fungal species representing 23 genera were isolated and identified. The most prevalent genera recorded were Cladosporium, Aspergillus, Penicillium and Fusarium. The total colony forming units of airborne fungi recovered in I.C.U. and O.R. ranged between 31.13-49.61 colonies/m3 on the four types of media usedl The fungal total catch of the dust samples collected from the air conditioning system filters in I.C.U. and O.R. were ranged from 65.5-170 colonies/mg dust. Since, the interest to replace synthetic xenobiotics by natural compounds with low environmental persistence and biodegradable to control such airborne fungal contaminants is needed. In this respect, essential oils showed to possess a broad spectrum of antifungal activity. Fungal static ability of six oils was tested on 30 different fungal isolates. Vapors of common thyme oil exhibited the strongest inhibitory effects on the tested isolates, whereas the headspace vapors of blue gum and ginger had no inhibitory effects on the tested fungal isolates. These data revealed that the air conditioning systems may be an important source of contamination in I.C.U. and O.R. of Assiut university hospitals. Thus, patients may be in risk of being exposed to contaminated atmospheric air by opportunistic fungi and the use of essential oils as an alternative option to control hospital wards from fungal contaminants needs further studies.
文摘This paper presents the data on operation reliability indices and relevant analyses toward China's conventional power generating units in 2009.The units brought into the statistical analysis include 100-MW or above thermal generating units,40-MW or above hydro generating units,and all nuclear generating units.The reliability indices embodied include utilization hours,times and hours of scheduled outages,times and hours of unscheduled outages,equivalent forced outage rate and equivalent availability factor.
文摘On December 25, 2009, after the 72-hour trail operation, Unit 2 of Laxiwa Hydropower Station on the Yellow River, constructed by CPI Yellow River Hydropower Corporation, was formally
文摘In the process of designing a municipal rainwater and sewage pumping station,it is necessary to accurately grasp the design points,reasonably determine the scale of the rainwater and sewage pumping station,scientifically select the location and layout,and select materials reasonably.After completing the process design of the municipal rainwater and sewage pumping station and putting it into operation,in order to ensure the normal and stable operation of the pumping station,it is necessary to focus on strengthening the operation and management of diving equipment,cleaning equipment,and electromechanical equipment.The author analyzes the key points and specific design path of the process design of municipal rainwater and sewage pumping stations,and puts forward effective strategies for operation management,hoping to contribute to the scientific design and stable operation of municipal rainwater and sewage pumping stations.
文摘Coal preparation is an integral part of the coal commodity supply chain. This stage of post-mining, pre-utilization beneficiation uses low-cost separation technologies to remove unwanted mineral matter and moisture which hinder the value of the coal product. Coal preparation plants typically employ several parallel circuits of cleaning and dewatering operations, with each circuit designed to optimally treat a specific size range of coal. Recent innovations in coal preparation have increased the efficiency and capac- ity of individual unit operations while reinforcing the standard parallel cleaning approach. This article, which describes the historical influences and state-of-the-art design for the various coal preparation unit operations, is organized to distinguish between coarse/intermediate coal cleaning and fine/ultrafine coal cleaning. Size reduction, screening, classification, cleaning, dewatering, waste disposal unit operations are particularly highlighted, with a special focus on the LI.S. design philosophy. Notable differences between the U.S. and international operations are described as appropriate.
基金Supported by the National Natural Science Foundation of China(21006127)the National Basic Research Program of China(2012CB720500)the Science Foundation of China University of Petroleum(KYJJ2012-05-28)
文摘Operation optimization is an effective method to explore potential economic benefits for existing plants. The m.aximum potential benefit from operationoptimization is determined by the distances between current operating point and process constraints, which is related to the margins of design variables. Because of various ciisturbances in chemical processes, some distances must be reserved for fluctuations of process variables and the optimum operating point is not on some process constraints. Thus the benefit of steady-state optimization can not be fully achied(ed while that of dynamic optimization can be really achieved. In this study, the steady-state optimizationand dynamic optimization are used, and the potential benefit-is divided into achievable benefit for profit and unachievable benefit for control. The fluid catalytic cracking unit (FCCU) is used for case study. With the analysis on how the margins of design variables influence the economic benefit and control performance, the bottlenecks of process design are found and appropriate control structure can be selected.
基金Supported by the National Natural Science Foundation of China (10771064)the Natural Science Foundation of Zhejiang province (Y6090036+1 种基金Y7080197,Y606197)the Foundation of Department of Education of Zhejiang Province (20070482)
文摘This paper deals with the boundedness and compactness of the weighted composition operators from the F(p, q, s) spaces, including Hardy space, Bergman space, Qp space, BMOA space, Besov space and α-Bloch space, to Bers-type spaces Hv^∞( or little Bers-type spaces Hv,o∞ ), where v is normal.
文摘In this paper we mainly consider little Hankel operators with squareintegrable symbols on the weighted Bergman spaces of the unit ball.We obtain that Schatten class of little Hankel operators is equivalent to Schatten class of positive Toeplitz operators under the conditions that SMO(f) ∈ L p/2 (B n,dλ) and 2 ≤ p ∞,which is very important to research the relation between Toeplitz operators and little Hankel operators.