The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It...The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It is found that the estimated local largest Lyapunov exponent is positive in all cases and the profile is similar to that of the local fractal dimension in this reactor. The positive largest Lyapunov exponent shows that the reactor is a nonlinear chaotic system. The obvious distribution indicates that the local nonlinear characteristic parameters such as the Lyapunov exponent and the fractal dimension could be applied to further study the flow characteristics such as the flow regine transitions and flow structures of the multi phase reactors.展开更多
Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressur...Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressure fluctuations obtained from a gas liquid solid three phase self aspirated reversed flow jet loop reactor,respectively.The results indicate that the local fractal dimensions and the local largest Lyapunov exponents in both the jet region and the tubular region inside the draft tube increase with the increase in the jet liquid flowrates and the solid loadings,the local fractal dimension profiles are similar to those of the largest Lyapunov exponent,the local largest lyapunov exponents are positive for all cases,and the flow behavior of such a reactor is chaotic.The local nonlinear characteristic parameters such as the local fractal dimension and the local largest Lyapunov exponent could be applied to further study the flow properties such as the flow regime transitions and flow structures of this three phase jet loop reactor.展开更多
The local liquid--phase characteristics of the gas--liquid two-phase and gas--liquid--solid threephase self-aspirated reversed flow jet loop reactor with a concentric gas--liquid injection nozzle were studied experime...The local liquid--phase characteristics of the gas--liquid two-phase and gas--liquid--solid threephase self-aspirated reversed flow jet loop reactor with a concentric gas--liquid injection nozzle were studied experimentally. They facilitate the evaluation of local phenomena. The local instantaneous liquid velocities at different axial positions of the reactor were measured by using the modified pilot tube.The local liquid-phase turbulent structural parameters such as time-averaged velocity. turbulent nuctuating velocity and turbulent micro scale were calculated with the aid of the statistical theory of turbulence. In particular, effects of liquid jet flowrates and solid loadings on the profiles of the liquid--phase turbulent structural parameter both in the jet effective region and in the tubular region inside the draft tube were discussed.展开更多
Dedicated experiments and numerical simulations have been conducted to investigate the splitting characteristics of a gas-liquid two phase flow at a T junction.The experiments were carried out for different gas-liquid...Dedicated experiments and numerical simulations have been conducted to investigate the splitting characteristics of a gas-liquid two phase flow at a T junction.The experiments were carried out for different gas-liquid velocities.The flow rates in the two branches were measured accurately to determine how the two considered phases distribute in the two outlets.The experimental results have shown that when the two outlet pressures are asymmetric,the two-phase flow always tends to flow into the outlet which has a lower pressure.As the inlet liquid velocity increases,however,the two-phase flow gradually tends to split evenly.Compared with the experiment results,the pressure difference between the two outlets can be determined more accurately by means of numerical simulation.The trends of experimental results and simulations are in very good agreement.展开更多
Some crude oils with high water cut have the capability to flow below the oil gel point, while the oil particles adhere to the pipe wall in the form of paste, also called "wall sticking". Wall sticking is a ...Some crude oils with high water cut have the capability to flow below the oil gel point, while the oil particles adhere to the pipe wall in the form of paste, also called "wall sticking". Wall sticking is a serious problem during the pipeline transportation, leading to partial or total blockage of the pipeline and energy wastage. In this paper, a series of laboratory flow loop experiments were conducted to observe the wall sticking characteristics of crude oil with high water cut, high viscosity and high gel point at low transportation temperatures. The effects of shear stress and water cut on the wall sticking rate and occurrence temperature were investigated. Experimental results indicated that the wall sticking rate and occurrence temperature were lower under stronger shear stress and higher water cut conditions. A criterion of wall sticking occurrence temperature(WSOT) and a regression model of wall sticking rate were then established. Finally, the software was developed to calculate the pressure drop along the pipelines of crude oils with high water-cut. It was able to predict the wall sticking thickness of gelled oil and then calculate the pressure drop along the pipelines. A typical case study indicated that the prediction results obtained from the software were in agreement with actual measured values.展开更多
The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),ma...The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),may be the reason and the solution to the loop flows.In this paper,the critical existence condition of the APLF is newly integrated into the simultaneous power flow model for the system and UPFC.Compared with the existing method of alternatively solving the simultaneous power flow and sensitivity-based approaching to the critical existing condition,the integrated power flow needs less iterations and calculation time.Besides,with wind power fluctuation,the interval power flow(IPF)is introduced into the integrated power flow,and solved with the affine Krawcyzk iteration to make sure that the range of active power setting of the UPFC not yielding the APLF.Compared with Monte Carlo simulation,the IPF has the similar accuracy but less time.展开更多
文摘The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It is found that the estimated local largest Lyapunov exponent is positive in all cases and the profile is similar to that of the local fractal dimension in this reactor. The positive largest Lyapunov exponent shows that the reactor is a nonlinear chaotic system. The obvious distribution indicates that the local nonlinear characteristic parameters such as the Lyapunov exponent and the fractal dimension could be applied to further study the flow characteristics such as the flow regine transitions and flow structures of the multi phase reactors.
文摘Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressure fluctuations obtained from a gas liquid solid three phase self aspirated reversed flow jet loop reactor,respectively.The results indicate that the local fractal dimensions and the local largest Lyapunov exponents in both the jet region and the tubular region inside the draft tube increase with the increase in the jet liquid flowrates and the solid loadings,the local fractal dimension profiles are similar to those of the largest Lyapunov exponent,the local largest lyapunov exponents are positive for all cases,and the flow behavior of such a reactor is chaotic.The local nonlinear characteristic parameters such as the local fractal dimension and the local largest Lyapunov exponent could be applied to further study the flow properties such as the flow regime transitions and flow structures of this three phase jet loop reactor.
文摘The local liquid--phase characteristics of the gas--liquid two-phase and gas--liquid--solid threephase self-aspirated reversed flow jet loop reactor with a concentric gas--liquid injection nozzle were studied experimentally. They facilitate the evaluation of local phenomena. The local instantaneous liquid velocities at different axial positions of the reactor were measured by using the modified pilot tube.The local liquid-phase turbulent structural parameters such as time-averaged velocity. turbulent nuctuating velocity and turbulent micro scale were calculated with the aid of the statistical theory of turbulence. In particular, effects of liquid jet flowrates and solid loadings on the profiles of the liquid--phase turbulent structural parameter both in the jet effective region and in the tubular region inside the draft tube were discussed.
基金the National Science and Technology Major Project of China(No.2016ZX05028-004-003).
文摘Dedicated experiments and numerical simulations have been conducted to investigate the splitting characteristics of a gas-liquid two phase flow at a T junction.The experiments were carried out for different gas-liquid velocities.The flow rates in the two branches were measured accurately to determine how the two considered phases distribute in the two outlets.The experimental results have shown that when the two outlet pressures are asymmetric,the two-phase flow always tends to flow into the outlet which has a lower pressure.As the inlet liquid velocity increases,however,the two-phase flow gradually tends to split evenly.Compared with the experiment results,the pressure difference between the two outlets can be determined more accurately by means of numerical simulation.The trends of experimental results and simulations are in very good agreement.
基金the support from the projects of the National Natural Science Foundation of China(No.51374224)for this research
文摘Some crude oils with high water cut have the capability to flow below the oil gel point, while the oil particles adhere to the pipe wall in the form of paste, also called "wall sticking". Wall sticking is a serious problem during the pipeline transportation, leading to partial or total blockage of the pipeline and energy wastage. In this paper, a series of laboratory flow loop experiments were conducted to observe the wall sticking characteristics of crude oil with high water cut, high viscosity and high gel point at low transportation temperatures. The effects of shear stress and water cut on the wall sticking rate and occurrence temperature were investigated. Experimental results indicated that the wall sticking rate and occurrence temperature were lower under stronger shear stress and higher water cut conditions. A criterion of wall sticking occurrence temperature(WSOT) and a regression model of wall sticking rate were then established. Finally, the software was developed to calculate the pressure drop along the pipelines of crude oils with high water-cut. It was able to predict the wall sticking thickness of gelled oil and then calculate the pressure drop along the pipelines. A typical case study indicated that the prediction results obtained from the software were in agreement with actual measured values.
基金the National Natural Science Foundation of China(Grant No.51877061).
文摘The active power loop flow(APLF)may be caused by impropriate network configuration,impropriate parameter settings,and/or stochastic bus powers.The power flow controllers,e.g.,the unified power flow controller(UPFC),may be the reason and the solution to the loop flows.In this paper,the critical existence condition of the APLF is newly integrated into the simultaneous power flow model for the system and UPFC.Compared with the existing method of alternatively solving the simultaneous power flow and sensitivity-based approaching to the critical existing condition,the integrated power flow needs less iterations and calculation time.Besides,with wind power fluctuation,the interval power flow(IPF)is introduced into the integrated power flow,and solved with the affine Krawcyzk iteration to make sure that the range of active power setting of the UPFC not yielding the APLF.Compared with Monte Carlo simulation,the IPF has the similar accuracy but less time.