Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressur...Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressure fluctuations obtained from a gas liquid solid three phase self aspirated reversed flow jet loop reactor,respectively.The results indicate that the local fractal dimensions and the local largest Lyapunov exponents in both the jet region and the tubular region inside the draft tube increase with the increase in the jet liquid flowrates and the solid loadings,the local fractal dimension profiles are similar to those of the largest Lyapunov exponent,the local largest lyapunov exponents are positive for all cases,and the flow behavior of such a reactor is chaotic.The local nonlinear characteristic parameters such as the local fractal dimension and the local largest Lyapunov exponent could be applied to further study the flow properties such as the flow regime transitions and flow structures of this three phase jet loop reactor.展开更多
The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It...The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It is found that the estimated local largest Lyapunov exponent is positive in all cases and the profile is similar to that of the local fractal dimension in this reactor. The positive largest Lyapunov exponent shows that the reactor is a nonlinear chaotic system. The obvious distribution indicates that the local nonlinear characteristic parameters such as the Lyapunov exponent and the fractal dimension could be applied to further study the flow characteristics such as the flow regine transitions and flow structures of the multi phase reactors.展开更多
Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 ...Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 flow rate, ultrasonic intensity and initial concentration of dimethoate on degradation rate were investigated. UALR imposed a synergistic effect combining sonochemical merit with high O3 transfer rate. The results showed that UALR not only increased degradation rate, but also was better than the simole sum of degradation by O3 and ultrasound separately. Under the operation conditions of O3 flow of 0.34 m^3·h^-1, ultrasonic intensity 3.71 W.cm^-2, and initial concentration of dimethoate at 20 mg·L^- 1, the degradation rate of dimethoate increased to 80%. UALR seems an advisable choice for treating organic wastewater and this process may have wide application prospect in industry.展开更多
A solution of 0.1 mol/L to 1.0 mol/L H2SO4 can dissolve alkali metals and alkaline earth metals which weaken an active site of SCR catalyst. The waste catalyst washed with 0.5 mol/L H2SO4 regained the best catalytic a...A solution of 0.1 mol/L to 1.0 mol/L H2SO4 can dissolve alkali metals and alkaline earth metals which weaken an active site of SCR catalyst. The waste catalyst washed with 0.5 mol/L H2SO4 regained the best catalytic activity. When a concentration of the sulfuric acid is less than 0.5 mol/L, sufficient cleaning effects cannot be obtained. In contrast, when the concentration is greater than 1.0 tool/L, the active components, vanadium and tungsten are undesirably eluted. The total BET surface of the catalyst regenerated by air lift loop reactor showed almost the same as that of fresh catalyst due to the removal of insoluble compounds which may be penetrated into pores of catalyst. The addition of a solution of 0.075 mol/L ammonium vanadate (NHnVO3) and 0.075 mol/L ammonium paratungstate (5(NH4)20· 12WO3-5H20) to 0.1 mol/L H2SO4 significantly increases the activity of the waste catalyst.展开更多
A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mas...A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mass transfer properties. Based on the analysis of geometrical construction and fluid properties of gas and slurry, MIALR was divided into six flow regions. In these flow regions, the local hydrodynamic characteristics were investigated over a wide range of operating variables. Furthermore, a new method was developed to measure the dissolved oxygen concentration. The volumetric mass-transfer coefficient in six flow regions was also calculated for comparison.展开更多
The mechanically stirred internal loop airlift reactors equipped with or without static mixers are devised for intensification of gas-liquid mass transfer rate. The influences of superficial gas velocity, agitation o...The mechanically stirred internal loop airlift reactors equipped with or without static mixers are devised for intensification of gas-liquid mass transfer rate. The influences of superficial gas velocity, agitation or static mixers on gas hold-up, mixing time, liquid circulating velocity and volumetric mass transfer coefficient have been investigated with tap water and carboxymethyl cellulose (CMC) aqueous solution. The experimental results indicate that mechanical agitation is more efficacious than static mixer in highly viscous media for improving mass transfer in airlift reactors. The empirical correlation of volumetric mass transfer coefficient with apparent viscosity, and energy consumption for mechanical agitation and aeration is developed.展开更多
Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-ge...Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-gen gas flow rate on the conversion of cyclohexene and selectivity of cyclohexene oxide were investigated and dis-cussed, and the optimal operation condition was found, under which 95.2% conversion of cyclohexene and 90.7% selectivity of cyclohexene oxide were achieved. The ultrasonic airlift loop reactor utilizes the synergistic effect of sonochemsitry and higher oxygen transfer rate. Possible reaction mechanisms were outlined and the reason of ul-trasound promotion of epoxidation reactionwas analyzed.展开更多
Flow characteristics, such as flow pattern, gas holdup, and bubble size distribution, in an internal loop reactor with external liquid circulation, are simulated to investigate the influence of reactor internals by us...Flow characteristics, such as flow pattern, gas holdup, and bubble size distribution, in an internal loop reactor with external liquid circulation, are simulated to investigate the influence of reactor internals by using the computational fluid dynamics (CFD)-population balance equations (PBE) coupled model. Numerical results reveal that introducing a downcomer tube and a draft tube can help to improve the mass and heat transfer of the reactor through enhanced liquid circulation, increased gas holdup and reduced bubble diameter. The hydrodynamic behavior in the internal loop reactor with external liquid circulation can be managed effectively by adjusting the diameter and axial position of the draft tube.展开更多
A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas vel...A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas velocity, the cross areas of riser and downcomer, gas hold-up and the local frictional loss coefficient. The experimental data indicate that either increase of gas flow rate or reduction of the downcomer diameter contributes to higher liquid circulation rate. The correlation between total and the local frictional loss coefficients was also established.Effects of gas flowrate in two risers and diameter of downcomer on the liquid circulation rate were examined. The value of total frictional loss coefficient was measured as a function of the cross area of downcomer and independent of the gas flow rate. The calculated results of liquid circulation rates agreed well with the experimental data with an average relative error of 9.6%.展开更多
Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in ...Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in multiphase systems. According to the model of macro-scale mass transfer in airlift loop reactors, it was proved that the airlift loop reactor can be regarded as a continuous stirred tank reactor for measuring mass transfer coefficient. The calculated mass transfer coefficient on such a basis is different from the volumetric mass transfer coefficient in the macro-scale model and the difference is discussed. To describe the time delay of the probe response to the change of oxygen concentration in the liquid phase, a model taking into account the time constant of response is es-tablished. Sensitivity analysis shows that this model can be used to measure the volumetric mass transfer coefficient. Applying this model to the measurement of volumetric mass transfer coefficient in the loop reactor, results that co-incide with the turbulence theory in the literate were obtained.展开更多
The estimation of the amount of reactive impurities in a loop reactor is of strategic importance to the propylene polymerization industry. It is essential to investigate the level of impurities in order to develop rel...The estimation of the amount of reactive impurities in a loop reactor is of strategic importance to the propylene polymerization industry. It is essential to investigate the level of impurities in order to develop reliable monitoring and control strategies. This paper described one approach based on generation function technique with the following two steps. First, a new mechanism for propylene polymerization was proposed by considering the effects of the reactive impurities in the material on the propylene polymerization. Second, a series of equations of population balance for the propylene polymerization in loop reactors were established based on the proposed mechanism. Accordingly, the equations were transformed into the mathematic matrix through the generation function technique to investigate the effects of the reactive impurities on the propylene polymerization. Significant effects of the reactive impurities were analyzed through computational simulation. The results show that the concentration of active centre on catalysts and the polymerization conversion both decrease with the increase of the initial concentration of any reactive impurity; hydrogen concentration decreases with the increase of the initial concentration of ethylene or butylenes, whereas, it increases with the increase of the initial concentration of propadiene; the simulated weight average molecular weight and the molecular weight distribution index of polymer resins both increase with the increase of the initial concentration of ethylene or butylenes. They decrease with the increase of the initial concentration of propadiene.展开更多
A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp...A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp, Qg and dD/dR were optimized. The average molar yield and purity of 2-chloro-5-chloromethylpyridine obtained were 79% and 98.5% respectively under the optimum operating conditions. Finally, the efficiency for the preparation of 2-chloro-5-chloromethylpyridine with ALR and stirred tank reactor (STR) respectively was compared.展开更多
Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared thr...Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared through several flow mixing models. The modeling results of two-parameter model indicated that there were higher ratio of full mixing zones and lower ratio of bypass flow in AL than in BC. Then a completely mixed-plug flow parallel combined (four-parameter) model was established. Modeling results show that it is more precise and more obvious than two-parameter model.展开更多
The hydrodynamic instability of the axial flow pump in a loop reactor has long been a troubling issue to be solved in the polyethylene industry due to the lack of a better mechanismic understanding.Generally,the insta...The hydrodynamic instability of the axial flow pump in a loop reactor has long been a troubling issue to be solved in the polyethylene industry due to the lack of a better mechanismic understanding.Generally,the instability of an axial flow pump can be reflected by the fluctuation of the pump head.In this study,the transient computational fluid dynamics(CFD)simulation is adopted to study the hydrodynamic instability of the axial flow pump used in an ethylene polymerization loop reactor.The results show that the pump head under single liquid phase nearly remains constant while the pump head under slurry phase fluctuates due to the variation of solid volume fraction distribution in the pump.Besides,under the combined effect of the maximum solid volume fraction difference in the pump and the turbulence intensity of the liquid phase,the fluctuation of the pump head under slurry phase increases when the solid volume fraction in the loop reactor increases from 0.10 to 0.29,and the fluctuation decreases,when the solid volume fraction increases from 0.29 to 0.35.Furthermore,there is a negative correlation between the pump head and the solid volume fraction in the pump;with the increase of solid volume fraction in the loop reactor,and the correlation coefficient increases as well.Moreover,a‘spiral particulate band’phenomenon is formed in the ascending leg caused by three mechanisms,viz.:the segregation of particles in all bends,the dispersion of particles by the secondary flow in the ascending leg,and the rotational movement of particles in the pump.展开更多
Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemi...Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemical method was adapted to measure local gas holdup andliquid velocity.A two-dimensional two-fluid model based on the first principles was established andimplemented to model the flow in airlift loop reactors.A corrected turbulent model was incorporatedin the simulation.The shear rate,shear stress and energy dissipation are evaluated from the flowfield.The numerically predicted results and experimental data obtained from this work as well as thesereported in literature are analyzed and compared.展开更多
Understanding of hydrodynamics in liquid jet loop reactors is a prerequisite step for the fur-ther study of multi-phase flow in loop reactors.A hydrodynamic simulation for liquid jet loop reac-tors is developed from t...Understanding of hydrodynamics in liquid jet loop reactors is a prerequisite step for the fur-ther study of multi-phase flow in loop reactors.A hydrodynamic simulation for liquid jet loop reac-tors is developed from the first principles of transport phenomena in this paper.The turbulence istaken into account by using the standard k-ε model.This approach is used to study the influence ofconfiguration and viscosity on the hydrodynamics.The results are in very reasonable coincidence to ex-perimental data in literature.展开更多
1 INTRODUCTIONGas and liquid distributions in a self-aspirated reverse flow jet loop reactor dependchiefly on the aspiration and the breakup against gas phase by the liquid nozzle aswell as the redistribution in the d...1 INTRODUCTIONGas and liquid distributions in a self-aspirated reverse flow jet loop reactor dependchiefly on the aspiration and the breakup against gas phase by the liquid nozzle aswell as the redistribution in the draft tube.It has also been noted that effective diffu-sion or backmixing in the reactor has great influence on the flow and mass transferrates.In this case,accurate descriptions about the fluid flow and diffusion conditions inthe reactor are most necessary for effective amplification of them.展开更多
1 INTRODUCTIONSelf-aspirated reversed flow jet loop reactors,characterized by a well defined flow pat-tern,well better dispersing effects,relatively low power consumption and a high masstransfer coefficient,are widely...1 INTRODUCTIONSelf-aspirated reversed flow jet loop reactors,characterized by a well defined flow pat-tern,well better dispersing effects,relatively low power consumption and a high masstransfer coefficient,are widely used in chemical engineering,especially in biochemicalengineering.The characteristics of such reactors are highly random or stochastic due tothe influence of a variety of phenomena such as jetting and bubbling of the展开更多
The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the ge...The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the geometry, the operating parameters and the physical properties of the liquid phase on gas hold-up and mass transfer coefficient were measuered. Compared with other types of gas-liquid reactor, D-JLR shows higher mass transfer coefficient and lower energy dissipation rate, the optimum diameter ratio was found to be about 0.42-0.6. A model for gas hold-up in D-JLR with Newtonian and non-Newtonian fluids has been developed on the basis of the equation of motion and the concept of average mixing length. The prediction of gas hold-up with the model agreed with the experimental results of this work.展开更多
Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empiric...Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empirical correlations for gas holdup and liquid velocity are proposed to ease the reactor design and scale-up.Different bubble circulation regimes were displayed in the first(lower) and second(upper) stages.Increasing superficial gas velocity and solid loading can promote regime transition of the second stage,and the gas holdup of the second stage is higher than that of the lower stage.In addition,the effects of solid loading on bubble behaviour are experimentally investigated for each stage.It is found that bubble size in the downcomer decreases with the presence of solid particles,and bubble size distribution widens under higher superficial gas velocity and lower solid loading.展开更多
文摘Hursts rescaled range (R/S) analysis and Wolfs attractor reconstruction technique have been adopted to estimate the local fractal dimensions and the local largest Lyapunov exponents in terms of the time series pressure fluctuations obtained from a gas liquid solid three phase self aspirated reversed flow jet loop reactor,respectively.The results indicate that the local fractal dimensions and the local largest Lyapunov exponents in both the jet region and the tubular region inside the draft tube increase with the increase in the jet liquid flowrates and the solid loadings,the local fractal dimension profiles are similar to those of the largest Lyapunov exponent,the local largest lyapunov exponents are positive for all cases,and the flow behavior of such a reactor is chaotic.The local nonlinear characteristic parameters such as the local fractal dimension and the local largest Lyapunov exponent could be applied to further study the flow properties such as the flow regime transitions and flow structures of this three phase jet loop reactor.
文摘The local chaos characteristics of the time series pressure fluctuations of gas liquid two phase flow in a self aspirated reversed flow jet loop reactor are studied by the deterministic chaos analysis technique. It is found that the estimated local largest Lyapunov exponent is positive in all cases and the profile is similar to that of the local fractal dimension in this reactor. The positive largest Lyapunov exponent shows that the reactor is a nonlinear chaotic system. The obvious distribution indicates that the local nonlinear characteristic parameters such as the Lyapunov exponent and the fractal dimension could be applied to further study the flow characteristics such as the flow regine transitions and flow structures of the multi phase reactors.
文摘Ultrasonic airlift loop reactor (UALR) shows potential and wide application for wastewater treatment. In this paper the performance and efficiency of UALR in dimethoate degradation were presented. The effects of O3 flow rate, ultrasonic intensity and initial concentration of dimethoate on degradation rate were investigated. UALR imposed a synergistic effect combining sonochemical merit with high O3 transfer rate. The results showed that UALR not only increased degradation rate, but also was better than the simole sum of degradation by O3 and ultrasound separately. Under the operation conditions of O3 flow of 0.34 m^3·h^-1, ultrasonic intensity 3.71 W.cm^-2, and initial concentration of dimethoate at 20 mg·L^- 1, the degradation rate of dimethoate increased to 80%. UALR seems an advisable choice for treating organic wastewater and this process may have wide application prospect in industry.
基金Project(2009T100100602) supported by the Korea Institute of Energy Technology Evaluation and Planning,Korea
文摘A solution of 0.1 mol/L to 1.0 mol/L H2SO4 can dissolve alkali metals and alkaline earth metals which weaken an active site of SCR catalyst. The waste catalyst washed with 0.5 mol/L H2SO4 regained the best catalytic activity. When a concentration of the sulfuric acid is less than 0.5 mol/L, sufficient cleaning effects cannot be obtained. In contrast, when the concentration is greater than 1.0 tool/L, the active components, vanadium and tungsten are undesirably eluted. The total BET surface of the catalyst regenerated by air lift loop reactor showed almost the same as that of fresh catalyst due to the removal of insoluble compounds which may be penetrated into pores of catalyst. The addition of a solution of 0.075 mol/L ammonium vanadate (NHnVO3) and 0.075 mol/L ammonium paratungstate (5(NH4)20· 12WO3-5H20) to 0.1 mol/L H2SO4 significantly increases the activity of the waste catalyst.
文摘A modified internal-loop airlif reactor (MIALR) with a continuous slurry phase was studied to investigate the local hydrodynamic characteristics, including gas holdup, bubble size, bubble rise velocity and local mass transfer properties. Based on the analysis of geometrical construction and fluid properties of gas and slurry, MIALR was divided into six flow regions. In these flow regions, the local hydrodynamic characteristics were investigated over a wide range of operating variables. Furthermore, a new method was developed to measure the dissolved oxygen concentration. The volumetric mass-transfer coefficient in six flow regions was also calculated for comparison.
文摘The mechanically stirred internal loop airlift reactors equipped with or without static mixers are devised for intensification of gas-liquid mass transfer rate. The influences of superficial gas velocity, agitation or static mixers on gas hold-up, mixing time, liquid circulating velocity and volumetric mass transfer coefficient have been investigated with tap water and carboxymethyl cellulose (CMC) aqueous solution. The experimental results indicate that mechanical agitation is more efficacious than static mixer in highly viscous media for improving mass transfer in airlift reactors. The empirical correlation of volumetric mass transfer coefficient with apparent viscosity, and energy consumption for mechanical agitation and aeration is developed.
基金Supported by Qinglan Project Foundation of Jiangsu Province and Doctoral Dissertation Innovate Foundation of Nanjing Uni-versity of Technology (No.BSCS200508).
文摘Epoxidation of cyclohexene to cyclohexene oxide was studied in a new type reactor—the ultrasound airlift loop reactor. The influences of ultrasound intensity, molar ratio of isobutyraldehyde to cyclohexene and oxy-gen gas flow rate on the conversion of cyclohexene and selectivity of cyclohexene oxide were investigated and dis-cussed, and the optimal operation condition was found, under which 95.2% conversion of cyclohexene and 90.7% selectivity of cyclohexene oxide were achieved. The ultrasonic airlift loop reactor utilizes the synergistic effect of sonochemsitry and higher oxygen transfer rate. Possible reaction mechanisms were outlined and the reason of ul-trasound promotion of epoxidation reactionwas analyzed.
基金Financial support from the Central Universities (12QN02)National Natural Science Foundation of China (51025624and 51076043)111 Project (B12034)
文摘Flow characteristics, such as flow pattern, gas holdup, and bubble size distribution, in an internal loop reactor with external liquid circulation, are simulated to investigate the influence of reactor internals by using the computational fluid dynamics (CFD)-population balance equations (PBE) coupled model. Numerical results reveal that introducing a downcomer tube and a draft tube can help to improve the mass and heat transfer of the reactor through enhanced liquid circulation, increased gas holdup and reduced bubble diameter. The hydrodynamic behavior in the internal loop reactor with external liquid circulation can be managed effectively by adjusting the diameter and axial position of the draft tube.
基金Supported by Liaoning Provincial Natural Science Foundation(No.972050).
文摘A multi-tube air-lift loop reactor (MT-ALR) is presented in this paper. Based on the energy conservation, a mathematical model describing the liquid circulation flow rate was developed, which was determined by gas velocity, the cross areas of riser and downcomer, gas hold-up and the local frictional loss coefficient. The experimental data indicate that either increase of gas flow rate or reduction of the downcomer diameter contributes to higher liquid circulation rate. The correlation between total and the local frictional loss coefficients was also established.Effects of gas flowrate in two risers and diameter of downcomer on the liquid circulation rate were examined. The value of total frictional loss coefficient was measured as a function of the cross area of downcomer and independent of the gas flow rate. The calculated results of liquid circulation rates agreed well with the experimental data with an average relative error of 9.6%.
基金Supported by the Specialized Research Fund for the Program of Higher Education (No.20050003030) and byTsinghua-Zhongda Postdoctoral Fellowship Program (No.20283600131).
文摘Inter-phase mass transfer is important to the design and performance of airlift loop reactors for either chemical or biochemical applications, and a good measurement technique is crucial for studying mass transfer in multiphase systems. According to the model of macro-scale mass transfer in airlift loop reactors, it was proved that the airlift loop reactor can be regarded as a continuous stirred tank reactor for measuring mass transfer coefficient. The calculated mass transfer coefficient on such a basis is different from the volumetric mass transfer coefficient in the macro-scale model and the difference is discussed. To describe the time delay of the probe response to the change of oxygen concentration in the liquid phase, a model taking into account the time constant of response is es-tablished. Sensitivity analysis shows that this model can be used to measure the volumetric mass transfer coefficient. Applying this model to the measurement of volumetric mass transfer coefficient in the loop reactor, results that co-incide with the turbulence theory in the literate were obtained.
基金This work was financially supported by the National Natural Science Foundation of China (No. 20406016)Fujian Petrochemical Company of SINOPEC (No. MS/FJ-08-JS-15-2005-01)
文摘The estimation of the amount of reactive impurities in a loop reactor is of strategic importance to the propylene polymerization industry. It is essential to investigate the level of impurities in order to develop reliable monitoring and control strategies. This paper described one approach based on generation function technique with the following two steps. First, a new mechanism for propylene polymerization was proposed by considering the effects of the reactive impurities in the material on the propylene polymerization. Second, a series of equations of population balance for the propylene polymerization in loop reactors were established based on the proposed mechanism. Accordingly, the equations were transformed into the mathematic matrix through the generation function technique to investigate the effects of the reactive impurities on the propylene polymerization. Significant effects of the reactive impurities were analyzed through computational simulation. The results show that the concentration of active centre on catalysts and the polymerization conversion both decrease with the increase of the initial concentration of any reactive impurity; hydrogen concentration decreases with the increase of the initial concentration of ethylene or butylenes, whereas, it increases with the increase of the initial concentration of propadiene; the simulated weight average molecular weight and the molecular weight distribution index of polymer resins both increase with the increase of the initial concentration of ethylene or butylenes. They decrease with the increase of the initial concentration of propadiene.
基金Natural Science Foundation of Tianjin(No.013605711)National Natural Science Foundation of China(No.20176040)
文摘A new process for the direct chlorination of 2-chloro-5-methylpyridine to yield 2-chloro-5-chloro-methylpyridine in an airlift loop reactor (ALR) has been studied. Five main reaction conditions including TR, na/ns, cp, Qg and dD/dR were optimized. The average molar yield and purity of 2-chloro-5-chloromethylpyridine obtained were 79% and 98.5% respectively under the optimum operating conditions. Finally, the efficiency for the preparation of 2-chloro-5-chloromethylpyridine with ALR and stirred tank reactor (STR) respectively was compared.
文摘Residence time distribution (RTD) analysis of liquid phase was conducted in an internal airlift loop reactor (AL) and a bubble column (BC) with the tracer response technique. These data were simulated and compared through several flow mixing models. The modeling results of two-parameter model indicated that there were higher ratio of full mixing zones and lower ratio of bypass flow in AL than in BC. Then a completely mixed-plug flow parallel combined (four-parameter) model was established. Modeling results show that it is more precise and more obvious than two-parameter model.
基金financial supports from Projects of the National Natural Science Foundation of China for Young (No.21808198)the Major Research Project of National Natural Science Foundation of China (No.91834303)the Science Fund for Creative Research Groups of National Natural Science Foundation of China (No.61621002)
文摘The hydrodynamic instability of the axial flow pump in a loop reactor has long been a troubling issue to be solved in the polyethylene industry due to the lack of a better mechanismic understanding.Generally,the instability of an axial flow pump can be reflected by the fluctuation of the pump head.In this study,the transient computational fluid dynamics(CFD)simulation is adopted to study the hydrodynamic instability of the axial flow pump used in an ethylene polymerization loop reactor.The results show that the pump head under single liquid phase nearly remains constant while the pump head under slurry phase fluctuates due to the variation of solid volume fraction distribution in the pump.Besides,under the combined effect of the maximum solid volume fraction difference in the pump and the turbulence intensity of the liquid phase,the fluctuation of the pump head under slurry phase increases when the solid volume fraction in the loop reactor increases from 0.10 to 0.29,and the fluctuation decreases,when the solid volume fraction increases from 0.29 to 0.35.Furthermore,there is a negative correlation between the pump head and the solid volume fraction in the pump;with the increase of solid volume fraction in the loop reactor,and the correlation coefficient increases as well.Moreover,a‘spiral particulate band’phenomenon is formed in the ascending leg caused by three mechanisms,viz.:the segregation of particles in all bends,the dispersion of particles by the secondary flow in the ascending leg,and the rotational movement of particles in the pump.
基金Supported by the National Natural Science Foundation of China.
文摘Hydrodynamics of airlift loop reactors was studied in detail experimentally andtheoretically.An internal airlift loop reactor was designed and set up for this study.An instru-mentation system based on the electrochemical method was adapted to measure local gas holdup andliquid velocity.A two-dimensional two-fluid model based on the first principles was established andimplemented to model the flow in airlift loop reactors.A corrected turbulent model was incorporatedin the simulation.The shear rate,shear stress and energy dissipation are evaluated from the flowfield.The numerically predicted results and experimental data obtained from this work as well as thesereported in literature are analyzed and compared.
基金Supported by the National Natural Science Foundation of China.
文摘Understanding of hydrodynamics in liquid jet loop reactors is a prerequisite step for the fur-ther study of multi-phase flow in loop reactors.A hydrodynamic simulation for liquid jet loop reac-tors is developed from the first principles of transport phenomena in this paper.The turbulence istaken into account by using the standard k-ε model.This approach is used to study the influence ofconfiguration and viscosity on the hydrodynamics.The results are in very reasonable coincidence to ex-perimental data in literature.
基金This work was supported by the National Science Foundation of China.
文摘1 INTRODUCTIONGas and liquid distributions in a self-aspirated reverse flow jet loop reactor dependchiefly on the aspiration and the breakup against gas phase by the liquid nozzle aswell as the redistribution in the draft tube.It has also been noted that effective diffu-sion or backmixing in the reactor has great influence on the flow and mass transferrates.In this case,accurate descriptions about the fluid flow and diffusion conditions inthe reactor are most necessary for effective amplification of them.
基金Supported by the Science Foundation of the ChineseAcademy of Science.
文摘1 INTRODUCTIONSelf-aspirated reversed flow jet loop reactors,characterized by a well defined flow pat-tern,well better dispersing effects,relatively low power consumption and a high masstransfer coefficient,are widely used in chemical engineering,especially in biochemicalengineering.The characteristics of such reactors are highly random or stochastic due tothe influence of a variety of phenomena such as jetting and bubbling of the
文摘The hydrodynamic and mass transfer characteristics of a downflow liquid jet loop reactor (D-JLR) were studied experimentally with water/air and CMC (carboxymethyl cellulose) solution/air systems. The effects of the geometry, the operating parameters and the physical properties of the liquid phase on gas hold-up and mass transfer coefficient were measuered. Compared with other types of gas-liquid reactor, D-JLR shows higher mass transfer coefficient and lower energy dissipation rate, the optimum diameter ratio was found to be about 0.42-0.6. A model for gas hold-up in D-JLR with Newtonian and non-Newtonian fluids has been developed on the basis of the equation of motion and the concept of average mixing length. The prediction of gas hold-up with the model agreed with the experimental results of this work.
基金Supported by the State Key Laboratory of Chemical Engineering(SKL-ChE-16B01)China Postdoctoral Science Foundation(2016M601263)
文摘Local hydrodynamics of a gas–liquid–solid system,such as bubble circulation regime,gas holdup,liquid velocity and axial profile of solid concentration,are studied in a two-stage internal loop airlift reactor.Empirical correlations for gas holdup and liquid velocity are proposed to ease the reactor design and scale-up.Different bubble circulation regimes were displayed in the first(lower) and second(upper) stages.Increasing superficial gas velocity and solid loading can promote regime transition of the second stage,and the gas holdup of the second stage is higher than that of the lower stage.In addition,the effects of solid loading on bubble behaviour are experimentally investigated for each stage.It is found that bubble size in the downcomer decreases with the presence of solid particles,and bubble size distribution widens under higher superficial gas velocity and lower solid loading.