In modern gas turbines, rim seal located between the stator-disc and rotor-disc is used to prevent hot-gas ingestion into the inner stage-gap of high pressure turbine. However, the purge flow supplied to the cavity th...In modern gas turbines, rim seal located between the stator-disc and rotor-disc is used to prevent hot-gas ingestion into the inner stage-gap of high pressure turbine. However, the purge flow supplied to the cavity through the rim seal interacts with the main flow, producing additional aerodynamic loss due to the mixing process which plays a significant role in the formation, development and evolution of downstream secondary flow. In this paper, a set of cascade representative of low aspect ratio turbine is selected to numerically investigate the influence of upstream cavity purge flow on the hub secondary flow structure and aerodynamic loss. Cascade with/without upstream cavity and four different purge mass flow rates are all taken into account in this simulation. Then, a deep insight into the loss mechanism of interaction between purge flow and main flow is gained. The results show that the presence of cavity and purge flow has a significant impact on the main flow which not only changes the vortex structure in both the passage and upstream cavity, but also alters the cascade exit flow angle distribution along the spanwise. Moreover, aerodynamic loss in the cascade rises with the increase of purge flow rate while the sealing effect is also enhanced. Therefore, the effect of upstream cavity purge flow must be considered in the process of turbine aerodynamic design. What is more, it is necessary to minimize the purge flow rate in order to reduce aerodynamic loss on the premise of satisfying cooling requirements.展开更多
The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying ...The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.展开更多
This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Nonc...This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Noncontact lap splices of rebars are used in vertical joints connecting adjacent precast panels for automated prefabrication and easy in situ erection. The seismic behavior of EVE walls was examined through a series of tests on six wall specimens with aspect ratios of 1.0~1.3. Test results showed that EVE wall specimens with inside cast-in situ concrete achieved the desired “strong bending and weak shear” and failed in shear mode. Common main diagonal cracks and brittle shear failure in squat cast-in situ walls were prevented. Inside cast-in situ concrete could signifi cantly improve the shear strength and stiff ness of EVE walls. The details of boundary elements (cast-in situ or prefabricated) and vertical joints (contiguous or spaced) had little eff ect on the global behavior of EVE walls. Noncontact lap splices in vertical joints could enable EVE walls to exhibit stable load-carrying capacity through extensive deformations. Evaluation on design codes revealed that both JGJ 3-2010 and ACI 318-14 provide conservative estimation of shear strength of EVE walls, and EVE walls achieved shear strength reserves comparative to cast-in situ walls. The recommended eff ective stiff ness for cast-in situ walls in ASCE 41-17 appeared to be appropriate for EVE walls.展开更多
基金Key Laboratory Foundation (9140C4103091003C) for funding this work
文摘In modern gas turbines, rim seal located between the stator-disc and rotor-disc is used to prevent hot-gas ingestion into the inner stage-gap of high pressure turbine. However, the purge flow supplied to the cavity through the rim seal interacts with the main flow, producing additional aerodynamic loss due to the mixing process which plays a significant role in the formation, development and evolution of downstream secondary flow. In this paper, a set of cascade representative of low aspect ratio turbine is selected to numerically investigate the influence of upstream cavity purge flow on the hub secondary flow structure and aerodynamic loss. Cascade with/without upstream cavity and four different purge mass flow rates are all taken into account in this simulation. Then, a deep insight into the loss mechanism of interaction between purge flow and main flow is gained. The results show that the presence of cavity and purge flow has a significant impact on the main flow which not only changes the vortex structure in both the passage and upstream cavity, but also alters the cascade exit flow angle distribution along the spanwise. Moreover, aerodynamic loss in the cascade rises with the increase of purge flow rate while the sealing effect is also enhanced. Therefore, the effect of upstream cavity purge flow must be considered in the process of turbine aerodynamic design. What is more, it is necessary to minimize the purge flow rate in order to reduce aerodynamic loss on the premise of satisfying cooling requirements.
基金The project supported by the Ministry of Education, Culture, Sports, Science and Technology (MEXT) Nuclear Researchers Exchange Program of Japan
文摘The center post is the most critical component as an inboard part of the toroidal field coil for the low aspect ratio tokamak. During the discharge it endures not only a tremendous ohmic heating owing to its carrying a rather high current but also a large nuclear heating and irradiation owing to the plasma operation. All the severe operating conditions, including the structure stress intensity and the stability of the structure, largely limit the maximum allowable current density. But in order to contain a very high dense plasma, it is hoped that the fusion power plant system can operate with a much high maximum magnetic field BT ≥12 T-15 T in the center post. A new method is presented in this paper to improve the maximum magnetic field up to 17 T and to investigate the possibility of the normal conducting center post to be used in the future fusion tokamak power plant.
基金Beijing Everest Green Building Technology Ltd. for the funding
文摘This study proposes an innovative precast shear wall system, called an EVE precast hollow shear wall structure (EVE-PHSW). Precast panels in EVE-PHSW are simultaneously precast with vertical and horizontal holes. Noncontact lap splices of rebars are used in vertical joints connecting adjacent precast panels for automated prefabrication and easy in situ erection. The seismic behavior of EVE walls was examined through a series of tests on six wall specimens with aspect ratios of 1.0~1.3. Test results showed that EVE wall specimens with inside cast-in situ concrete achieved the desired “strong bending and weak shear” and failed in shear mode. Common main diagonal cracks and brittle shear failure in squat cast-in situ walls were prevented. Inside cast-in situ concrete could signifi cantly improve the shear strength and stiff ness of EVE walls. The details of boundary elements (cast-in situ or prefabricated) and vertical joints (contiguous or spaced) had little eff ect on the global behavior of EVE walls. Noncontact lap splices in vertical joints could enable EVE walls to exhibit stable load-carrying capacity through extensive deformations. Evaluation on design codes revealed that both JGJ 3-2010 and ACI 318-14 provide conservative estimation of shear strength of EVE walls, and EVE walls achieved shear strength reserves comparative to cast-in situ walls. The recommended eff ective stiff ness for cast-in situ walls in ASCE 41-17 appeared to be appropriate for EVE walls.