期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Comparison of central corneal thickness measurements with three new optical devices and a standard ultrasonic pachymeter 被引量:8
1
作者 Hasan Ali Bayhan Seray Aslan Bayhan Iz.zet Can 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第2期302-308,共7页
AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their ag... AIM:To compare the RTVue spectral optical coherence tomography(SD-OCT),Sirius Scheimpflug-Placido topographer,Lenstar optical low coherence reflectometry(OLCR)and ultrasound pachymetry(USP)devices in terms of their agreement and repeatability of measuring central corneal thickness(CCT).METHODS:In this prospective study,50 eyes of 50patients were included.Three repeated measures were obtained using SD-OCT,Scheimpflug-Placido topographer and USP and five measurements were determined with the OLCR.Bland-Altman plots were used to assess agreement among the instruments,and 95%limits of agreement(LoA)for each comparison were calculated.Intra-examiner repeatability was assessed using intraclass correlation coefficients(ICCs).RESULTS:The mean CCT by SD-OCT,ScheimpflugPlacido topographer,OLCR,and USP were 525.90±34.08μm,525.92±34.10μm,530.30±35.62μm,and543.50±37.11μm respectively.All 4 modalities of CCT measurements correlated closely with each other,with Pearson correlation coefficients ranging from 0.977 to0.995.The mean differences(and upper/lower LoA)for CCT measurements were-0.05±6.77μm(13.3/-13.3)between SD-OCT and Scheimpflug-Placido topographer,4.38±3.79μm(11.8/-3.1)between OLCR and SD-OCT,4.38±6.03μm(16.2/-7.5)between OLCR and ScheimpflugPlacido topographer,13.20±6.46μm(25.9/0.5)between USP and OLCR,17.59±6.76μm(30.8/4.3)between USP and SD-OCT,and 17.58±8.13μm(33.5/1.6)between USP and Scheimpflug-Placido topographer.Intra-examiner repeatability was excellent for all devices with ICCs】0.98.CONCLUSION:For most practical purposes,CCT measurements with the RTVue,Sirius and Lenstar can be used interchangeably.Although highly correlated,CCTmeasurement differences between USP and these 3optical instruments can be significant depending on the clinical situation. 展开更多
关键词 central corneal thickness optical low coherence reflectometry spectral optical coherence tomography Scheimpflug-Placido topographer
下载PDF
Long term integration of radar signals with unknown Doppler shift for ubiquitous radar 被引量:4
2
作者 Qinglong Bao Zengping Chen Yue Zhang Jian Yang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2011年第2期219-227,共9页
Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range target... Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range targets impacts selection of waveform parameters. The coherent processing interval (CPI) must be long enough to achieve a certain signal-to-noise ratio (SNR) that ensures the efficiency of detection. The condition of detection in the case of low SNR is analyzed, and three different cases that would occur during integration are discussed and a method to determine the CPI is presented. The simulation results show that targets detection with SNR as low as -26 dB in the experimental system can possibly determine the CPI. 展开更多
关键词 ubiquitous radar low signal-to-noise ratio (SNR) coherent processing interval (CPI) coherent integration non-coherent integration.
下载PDF
Comparison of a new optical biometer and a standard biometer in cataract patients 被引量:7
3
作者 Pipat Kongsap 《Eye and Vision》 SCIE 2016年第1期283-288,共6页
Background:Cataract surgery is the most common surgical procedure in ophthalmology.Biometry data and accurate intraocular lens(IOL)calculations are very important in achieving the desired refractive outcomes.The aim o... Background:Cataract surgery is the most common surgical procedure in ophthalmology.Biometry data and accurate intraocular lens(IOL)calculations are very important in achieving the desired refractive outcomes.The aim of this study was to compare measurements using a new optical low coherence reflectometry(OLCR)biometer(OA-2000)and the gold standard partial coherence interferometry(PCI)optical biometer(IOLMaster 500).Methods:Ocular biometry of cataract patients were measured by the OA-2000 and IOLMaster 500 to compare keratometry(K),axial length(AL),anterior chamber depth(ACD),white-to-white(WTW)diameter,and IOL power using the SRK/T formula.Results:One hundred and two eyes of 68 cataract patients were evaluated with the two optical biometers.The mean values of the AL,K,ACD,and WTW differed very little(OCLR biometer,23.12 mm,44.50 diopters(D),3.06,and 11.64 mm,respectively;PCI biometer,23.18 mm,44.6 D,3.15,and 11.86 mm,respectively),but the differences were significant(all,p≤0.05).The AL,K,and ACD showed excellent correlations(r=0.999,0.980,and 0.824,respectively;all p<0.001);however,there was a weak correlation of the WTW diameter between the two devices(r=0.256).The IOL powers using the SRK-T formula derived from both instruments were very similar,with an excellent correlation(r=0.989).The mean difference between the two instruments was 0.32 D.Conclusions:The OLCR biometer showed very a strong agreement with the standard PCI optical biometer for almost all ocular biometry measurements,except for the WTW diameter.Trial registration:TCTR20160614003;date 06/09/2016;‘retrospectively registered’. 展开更多
关键词 Intraocular lens power calculation Partial coherence interferometry Optical low coherence reflectometer Optical biometer Cataract surgery
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部