期刊文献+
共找到5,189篇文章
< 1 2 250 >
每页显示 20 50 100
Establishment of NaLuF_(4):15%Tb-based low dose X-PDT agent and its application on efficient antitumor therapy
1
作者 Yi Tian Zhiguang Fu +7 位作者 Xiaosheng Zhu Chunjing Zhan Jinwei Hu Li Fan Chaojun Song Qian Yang Yu Wang Mei Shi 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第3期599-610,共12页
X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.Howev... X-ray excited photodynamic therapy(X-PDT)is the bravo answer of photodynamic therapy(PDT)for deep-seated tumors,as it employs X-ray as the irradiation source to overcome the limitation of light penetration depth.However,high X-ray irradiation dose caused organ lesions and side effects became the major barrier to X-PDT application.To address this issue,this work employed a classic-al co-precipitation reaction to synthesize NaLuF_(4):15%Tb^(3+)(NLF)with an average particle size of(23.48±0.91)nm,which was then coupled with the photosensitizer merocyanine 540(MC540)to form the X-PDT system NLF-MC540 with high production of singlet oxygen.The system could induce antitumor efficacy to about 24%in relative low dose X-ray irradiation range(0.1-0.3 Gy).In vivo,when NLF-MC540 irradiated by 0.1 Gy X-ray,the tumor inhibition percentage reached 89.5%±5.7%.The therapeutic mechanism of low dose X-PDT was found.A significant increase of neutrophils in serum was found on the third day after X-PDT.By immunohistochemical staining of tumor sections,the Ly6G^(+),CD8^(+),and CD11c^(+)cells infiltrated in the tumor microenvironment were studied.Utilizing the bilat-eral tumor model,the NLF-MC540 with 0.1 Gy X-ray irradiation could inhibit both the primary tumor and the distant tumor growth.De-tected by enzyme linked immunosorbent assay(ELISA),two cytokines IFN-γand TNF-αin serum were upregulated 7 and 6 times than negative control,respectively.Detected by enzyme linked immune spot assay(ELISPOT),the number of immune cells attributable to the IFN-γand TNF-αlevels in the group of low dose X-PDT were 14 and 6 times greater than that in the negative control group,respectively.Thus,it conclude that low dose X-PDT system could successfully upregulate the levels of immune cells,stimulate the secretion of cy-tokines(especially IFN-γand TNF-α),activate antitumor immunity,and finally inhibit colon tumor growth. 展开更多
关键词 x-ray excited photodynamic therapy singlet oxygen low dose x-ray irradiation efficient antitumor therapy anti-tumor immunity
下载PDF
Organic X-Ray Image Sensors Using a Medium Bandgap Polymer Donor with Low Dark Current
2
作者 Jong-Woon Ha Seung Hun Eom +11 位作者 Bo Kyung Cha Seyeong Song Hyeong Ju Eun Jong H.Kim Jong Mok Park BongSoo Kim Byoungwook Park Seo-Jin Ko Sung Cheol Yoon Changjin Lee In Hwan Jung Do-Hoon Hwang 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2024年第6期230-237,共8页
The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations.However,this is quite challenging because of the heavy weight of the scintillator and s... The development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations.However,this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors.The weight and thickness of X-ray detectors can be reduced by replacing the silicon layer with an organic photodetectors.This study presents a novel bithienopyrroledione-based polymer donor that exhibits excellent photodetection properties even in a thick photoactive layer(~700 nm),owing to the symmetric backbone and highly soluble molecular structure of bithienopyrroledione.The ability of bithienopyrroledione-based polymer donor to strongly suppress the dark current density(Jd~10−10 A cm^(−2))at a negative bias(−2.0 V)while maintaining high responsivity(R=0.29 A W−1)even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of D_(sh)^(*)=2.18×10^(13)Jones in the organic photodetectors.Printed organic photodetectors are developed by slot-die coating for use in X-ray detectors,which exhibit D_(sh)^(*)=2.73×10^(12)Jones with clear rising(0.26 s)and falling(0.29 s)response times upon X-ray irradiation.Detection reliability is also proven by linear response of the X-ray detector,and the X-ray detection limit is 3 mA. 展开更多
关键词 low dark current low detection limit organic photodetector printable x-ray
下载PDF
Investigation of bubbles escape behavior from low basicity mold flux for high-Mn high-Al steels using 3D X-ray microscope
3
作者 Qiang Liu Xiang Li +3 位作者 Shen Du Ming Gao Yanbin Yin Jiongming Zhang 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS 2025年第1期102-110,共9页
During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a rest... During the continuous casting process of high-Mn high-Al steels,various types of gases such as Ar need to escape through the top of the mold.In which,the behavior of bubbles traversing the liquid slag serves as a restrictive link,closely associated with viscosity and the thickness of liquid slag.In contrast to two-dimensional surface observation,three-dimensional(3D)analysis method can offer a more intuitive,accurate,and comprehensive information.Therefore,this study employs a 3D X-ray microscope(3D-XRM)to obtained spatial distribution and 3D morphological characteristics of residual bubbles in mold flux under different basicity of liquid slag,different temperatures,and different holding times.The results indicate that as basicity of slag increases from 0.52 to 1.03,temperature increases from 1423 to 1573 K,the viscosity of slag decreases,the floating rate of bubbles increases.In addition,when holding time increases from 10 to 30 s,the bubbles floating distance increases,and the volume fraction and average equivalent sphere diameter of the bubbles solidified in the mold flux gradually decreases.In one word,increasing the basicity,temperature,and holding time leading to an increase in the removal rate of bubbles especially for the large.These findings of bubbles escape behavior provide valuable insights into optimizing low basicity mold flux for high-Mn high-Al steels. 展开更多
关键词 mold flux low basicity BUBBLES three-dimensional x-ray microscope VISCOSITY
下载PDF
Effect of low dose laser cycloplasty on deepening anterior chamber in chronic angle-closure glaucoma 被引量:2
4
作者 Xuan-Li Zheng Hai-Shuang Lin +4 位作者 Xiao-Jie Wang Jia-Qian Li Yan-Qian Xie Shao-Dan Zhang Yuan-Bo Liang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第12期2011-2017,共7页
AIM:To describe the outcome of using low-dose laser cycloplasty(LCP)in chronic angle-closure glaucoma(CACG).METHODS:A retrospective case series.Medical charts of CACG patients who underwent LCP in the Eye Hospital of ... AIM:To describe the outcome of using low-dose laser cycloplasty(LCP)in chronic angle-closure glaucoma(CACG).METHODS:A retrospective case series.Medical charts of CACG patients who underwent LCP in the Eye Hospital of Wenzhou Medical University were reviewed.The main outcomes included intraocular pressure(IOP),the number of glaucoma medication,anterior segment parameters and surgery-related complications.RESULTS:A total of 7 eyes of 7 CACG patients(age 38.9±11.0y)underwent LCP with a mean follow-up of 27.1±13.7mo(range 16-48mo).Following LCP,mean IOP and glaucoma medications decreased from 26.1±6.1 mm Hg with 3.1±1.1 glaucoma medications pre-treatment to 14.9±3.1 mm Hg(P=0.027)with 0.4±1.1 glaucoma medications(P=0.001)at final follow-up.The anterior chamber depth(ACD),angle opening distance500 and trabecular-iris angle increased from 1.65±0.33 mm,0.05 mm(range 0-0.30 mm)and 5.1°(range,0-31.97°)at baseline to 1.98±0.43 mm(P=0.073),0.53 mm(range 0.42-0.91 mm,P=0.015),45.9°(range,40.2°-59.4°),(P=0.015)in the long-term follow-up,respectively.The deepening of ACD and reopening of anterior chamber angle(ACA)was observed in 6 eyes(85.7%).CONCLUSION:LCP is a promising treatment option for patients with CACG via reducing IOP and glaucoma medication without serious complications.In addition,LCP can bring a significant deepening in ACD and reopening of ACA. 展开更多
关键词 chronic angle-closure glaucoma low dose laser cycloplasty anterior chamber depth intraocular pressure
下载PDF
Variant Wasserstein Generative Adversarial Network Applied on Low Dose CT Image Denoising
5
作者 Anoud A.Mahmoud Hanaa A.Sayed Sara S.Mohamed 《Computers, Materials & Continua》 SCIE EI 2023年第5期4535-4552,共18页
Computed Tomography(CT)images have been extensively employed in disease diagnosis and treatment,causing a huge concern over the dose of radiation to which patients are exposed.Increasing the radiation dose to get a be... Computed Tomography(CT)images have been extensively employed in disease diagnosis and treatment,causing a huge concern over the dose of radiation to which patients are exposed.Increasing the radiation dose to get a better image may lead to the development of genetic disorders and cancer in the patients;on the other hand,decreasing it by using a Low-Dose CT(LDCT)image may cause more noise and increased artifacts,which can compromise the diagnosis.So,image reconstruction from LDCT image data is necessary to improve radiologists’judgment and confidence.This study proposed three novel models for denoising LDCT images based on Wasserstein Generative Adversarial Network(WGAN).They were incorporated with different loss functions,including Visual Geometry Group(VGG),Structural Similarity Loss(SSIM),and Structurally Sensitive Loss(SSL),to reduce noise and preserve important information on LDCT images and investigate the effect of different types of loss functions.Furthermore,experiments have been conducted on the Graphical Processing Unit(GPU)and Central Processing Unit(CPU)to compare the performance of the proposed models.The results demonstrated that images from the proposed WGAN-SSIM,WGAN-VGG-SSIM,and WGAN-VGG-SSL were denoised better than those from state-of-the-art models(WGAN,WGAN-VGG,and SMGAN)and converged to a stable equilibrium compared with WGAN and WGAN-VGG.The proposed models are effective in reducing noise,suppressing artifacts,and maintaining informative structure and texture details,especially WGAN-VGG-SSL which achieved a high peak-signalto-noise ratio(PNSR)on both GPU(26.1336)and CPU(25.8270).The average accuracy of WGAN-VGG-SSL outperformed that of the state-ofthe-art methods by 1 percent.Experiments prove that theWGAN-VGG-SSL is more stable than the other models on both GPU and CPU. 展开更多
关键词 Machine learning deep learning image denoising low dose CT loss function
下载PDF
Efficacy of Low Dose Naltrexone on Pain Reduction in Chronic Pain Syndromes: A Meta Analysis
6
作者 Haroutiun Hamzoian Shehzad Choudry 《Pain Studies and Treatment》 2023年第3期15-25,共11页
Chronic pain is a multifaceted debilitating experience often associated with significant physical and emotional burden. Low dose naltrexone (LDN) has gained attention in recent years for its potential utility in the m... Chronic pain is a multifaceted debilitating experience often associated with significant physical and emotional burden. Low dose naltrexone (LDN) has gained attention in recent years for its potential utility in the management of fibromyalgia, irritable bowel syndrome, multiple sclerosis, and painful diabetic neuropathy. LDN’s analgesic effects have been associated with its ability to increase the production of endorphins while reducing the production of tumor necrosis factor-alpha, interleukin-6, reactive oxygen species and nitric oxide. This meta-analysis aims to systematically review and synthesize the available evidence on efficacy of LDN as an analgesic in pain syndromes, with a focus on chronic (neuro) inflammatory diseases. The goal is to provide clinicians with a more comprehensive estimate of the effectiveness of LDN as a non-opioid option for managing chronic pain and guide future research in the area. Thirteen randomized control trials, published from 1990 to 2022, were selected for the analysis that satisfied inclusion criteria. The overall effects in these studies were calculated using the standardized mean difference (SMD) between the LDN and placebo groups. We found an overall SMD of -10.77 (95% CI: -13.96 to -7.58) with a p-value of 0.002. This indicated that the LDN group experienced a statistically significant reduction in pain compared to placebo. This meta-analysis provides evidence for the potential efficacy of low dose naltrexone in reducing pain and enhancing analgesia in various pain syndromes. LDN may be a useful treatment option for patients suffering from chronic pain, particularly with fibromyalgia, multiple sclerosis, or diabetic neuropathy. However, further research is needed to confirm the efficacy and safety of low dose naltrexone for chronic pain conditions, especially with larger sample sizes, standardized dosing regimens and treatment durations. 展开更多
关键词 Pain Management LDN PAIN ANESTHESIOLOGY NEUROLOGY low dose Naltrexone Chronic Pain
下载PDF
Evaluation of Entrance Skin Dose from Paediatric Diagnostic X-Ray Examination
7
作者 Moromoke Oluwayemisi Adelayi Oladele Samuel Ajayi 《Open Journal of Radiology》 2023年第1期26-33,共8页
As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while consideri... As children are prone to be more radiosensitive than adults, it is imperative to assess the Entrance Skin Doses (ESDs) for patients being examined by X-rays, in order to ensure the optimization of dose while considering a number of other fickles. The ESD received by 50 paediatrics (aged 1-13 years) undergoing 8 types of X-ray examinations were measured at Federal Teaching Hospital, Ido-Ekiti, Ekiti, Nigeria, within a period of February 2019 to March 2020 using thermoluminescent dosimeters. The mean ± SD of ESDs were 0.85 ± 0.32, 2.04 ± 0.75, 0.60 ± 0.07, 0.62 ± 0.22, 0.57 ± 0.24, 1.75 ± 0.76, 0.93 ± 0.31 and 0.63 ± 0.06 mGy for Chest, Skull, Hand, Forearm, Knee, Abdomen, Leg and Feet, respectively. The mean ESDs were found to be within the recommended reference dose in all examinations, except for the Chest examination which was higher. The data obtained in this study will serve as existing data in Nigeria for future research works, as it would assist in optimizing dose to patients, especially the paediatrics. 展开更多
关键词 Entrance Skin dose PAEDIATRICS x-rays
下载PDF
Effective Dose Screening of Low Level Red Light in Different Cell Indexes
8
作者 Qiu Shuting Pan Zhi +3 位作者 Jiang Xiao Hu Fan Zhang Hao Wu Fengjuan 《China Detergent & Cosmetics》 CAS 2023年第3期41-50,共10页
The low level red light irradiation dose that produced positive response on different cell indexes was selected through experiments.In fibroblast detection model,the low level red light irradiation dose that had posit... The low level red light irradiation dose that produced positive response on different cell indexes was selected through experiments.In fibroblast detection model,the low level red light irradiation dose that had positive response to the four indicators of mitochondrial membrane potential,ATP release,cell migration and collagen synthesis was screened.The experimental results showed that low level red light with a irradiation dose of 2 J/cm^(2) had a positive response to the above four indexes in fibroblast.The test model on fibroblast was later transferred to dermal papilla cells for further experimental verification.The results showed that low level red light with a irradiation dose of 2 J/cm^(2) also had a positive response to the four indicators of dermal papilla cells,namely,mitochondrial membrane potential,ATP release,cell proliferation rate and collagen synthesis.It is proved that the low level red light with a irradiation dose of 2 J/cm^(2) could improve the mitochondrial function,cell migration and collagen synthesis of fibroblast and dermal papilla cell,thus providing energy for cell activities,improving cell repair ability and cell anti-aging ability. 展开更多
关键词 low level red light dose screening mitochondrial function collagen synthesis cell migration
下载PDF
Local low-dose X-ray radiation promotes homing of mesenchymal stem cells to the injured mouse spinal cord
9
作者 Panjun Wang Xiaohui Zhang +7 位作者 Leixi Xue Yu Sun Songguang Ju Liesong Chen Jiasheng Hu Hong Zhang Xueguang Zhang Jinxiang Fu 《Neural Regeneration Research》 SCIE CAS CSCD 2010年第5期331-336,共6页
BACKGROUND: Bone marrow-derived mesenchymal stem cells (BMSCs) are a potentially useful source for cell replacement therapy following spinal cord injury. However, the homing characteristics of BMSCs in vivo remain ... BACKGROUND: Bone marrow-derived mesenchymal stem cells (BMSCs) are a potentially useful source for cell replacement therapy following spinal cord injury. However, the homing characteristics of BMSCs in vivo remain unclear. Low-dose radiation has been shown to promote homing of BMSCs to exposed sites. OBJECTIVE: To investigate the effects of low-dose local radiation to non-injured areas on the ability of human BMSCs to home to the injured mouse spinal cord, as well as recovery of spinal cord injury. DESIGN, TIME AND SE'I-FING: A randomized, controlled, animal experiment was performed at the Central Laboratory, Second Affiliated Hospital of Soochow University between October 2007 and October 2008. MATERIALS: BMSCs were isolated from four adult, human donors. METHODS: Fifty adult, female, Balb/c mice were subjected to adjusted weight-drop impact resulting in complete paraplegia. Three days later, mice were randomly assigned to a radiation + transplantation group (n = 23) and a transplantation group (n = 20). In total, 2 x 106 carboxyfluorescein diacetate succinimidyl ester-labeled BMSCs were injected into each mouse via the caudal vein. Mice in the radiation + transplantation group received 2.5 Gy local X-ray irradiation 2 hours before BMSCs injection. MAIN OUTCOME MEASURES: The homing of BMSCs to injured cord and irradiated skin after transplantation was observed by fluorescence microscope; the structure recovery of injured cord was assessed by magnetic resonance imaging. RESULTS: Compared with the transplantation group, at 24 hours after transplantation, the number of BMSCs was significantly increased in the injured area and the exposed site (P 〈 0.05), and inflammation and edema were significantly alleviated in the injured cord in the radiation + transplantation group. CONCLUSION: Local low-dose radiation has the potential to promote homing of BMSCs and recovery of spinal cord injury, although the radiated region was not injured area. 展开更多
关键词 low-dose radiation bone marrow-derived mesenchymal stem cells spinal cord injury cell therapy neural regeneration
下载PDF
Effects of Low Dose Radiation on Tumor Apoptosis, Cell Cycle and Apoptosis-Related Protein Bcl-2 in Tumor-Bearing Mice 被引量:2
10
作者 于洪升 宋爱琴 +2 位作者 费从合 王卓敏 邱文生 《The Chinese-German Journal of Clinical Oncology》 CAS 2005年第2期89-92,共4页
To study the effects of low dose radiation (LDR) on tumor apoptosis, cellcycle progression and changes of apoptosis-related protein Bcl-2 in tumor-bearing mice. Methods:Male mice of Kunming strain were implanted subcu... To study the effects of low dose radiation (LDR) on tumor apoptosis, cellcycle progression and changes of apoptosis-related protein Bcl-2 in tumor-bearing mice. Methods:Male mice of Kunming strain were implanted subcutaneously with S180 sarcoma cells in the left inguenas an in situ experimental animal model. Seven days later, the mice were subjected to 75 mGywhole-body γ-irradiation. At 24 and 48 h after the irradiation, all mice were sacrificed. The tumorsizes were measured, and tumor cell apoptosis and cell cycle progression were analyzed by flowcytometry. The expression of apoptosis-related protein Bcl-2 and the apoptotic rate of tumor cellswere observed by immunohistochemistry and electron microscopy. Results: Tumors grew significantlyslower after LDR (P 【 0.05). The tumor cells were arrested in G1 phrase and the expression of Bcl-2protein decreased at 24 h. Apoptotic rate of tumor cells was increased significantly at 48 h afterLDR (P 【 0.01). Conclusion: LDR could cause a G1-phase arrest and increase the apoptosis of tumorcells through the low level of apoptosis-related protein bcl-2 in the tumor-bearing mice. Theorganized immune function and anti-tumor ability are markedly increased after LDR. Our studyprovides practical evidence of clinical application to cancer treatment. 展开更多
关键词 low dose radiation S180 sarcoma APOPTOSIS cell cycle BCL-2
下载PDF
Interaction between Helicobacter pylori infection, nonsteroidal anti-inflammatory drugs and/or low-dose aspirin use: Old question new insights 被引量:8
11
作者 Carlos Sostres Carla Jerusalen Gargallo Angel Lanas 《World Journal of Gastroenterology》 SCIE CAS 2014年第28期9439-9450,共12页
Previous reports clearly demonstrated that Helicobacter pylori(H.pylori)infection,nonsteroidal anti-inflammatory drugs(NSAID)or low dose aspirin(ASA)use significantly and independently increased the risk for the devel... Previous reports clearly demonstrated that Helicobacter pylori(H.pylori)infection,nonsteroidal anti-inflammatory drugs(NSAID)or low dose aspirin(ASA)use significantly and independently increased the risk for the development of peptic ulcer disease.Today,the presence of H.pylori infection associated with low dose ASA and/or NSAID use in the same patient is becoming more frequent and therefore the potential interaction between these factors and the consequences of it has important implications.Whether NSAID intake in the presence of H.pylori infection may further increase the risk of peptic ulcer carried by the presence of only one risk factor is still a matter of debate.Studies on the interaction between the two risk factors yielded conflicting data and no consensus has been reached in the last years.In addition,the interaction between H.pylori infection and low-dose ASA remains even more controversial.In real clinical practice,we can find different clinical scenarios involving these three factors associated with the presence of different gastrointestinal and cardiovascular risk factors.These huge variety of possible combinations greatly hinder the decision making process of physicians. 展开更多
关键词 Nonsteroidal anti-inflammatory drugs low dose aspirin Helicobacter pylori infection Helicobacter pylori eradication Peptic ulcer disease
下载PDF
Involvement of Endoplasmic Reticulum Stress in Apoptosis of Testicular Cells Induced by Low-dose Radiation 被引量:7
12
作者 王志成 王剑锋 +4 位作者 李艳博 郭彩霞 刘扬 方芳 龚守良 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第4期551-558,共8页
Summary: The study examined the role of endoplasmic reticulum stress (ERS) and signaling pathways of inositol-requiring enzyme-1 (IRE1), RNA-activated protein kinase-like ER kinase (PERK) and activating transcr... Summary: The study examined the role of endoplasmic reticulum stress (ERS) and signaling pathways of inositol-requiring enzyme-1 (IRE1), RNA-activated protein kinase-like ER kinase (PERK) and activating transcription factor-6 (ATF6) in apoptosis of mouse testicular cells treated with low-dose radiation (LDR). In the dose-dependent experiment, the mice were treated with whole-body X-ray irradiation at different doses (25, 50, 75, 100 or 200 mGy) and sacrificed 12 h later. In the time-dependent experiment, the mice were exposed to 75 mGy X-ray irradiation and killed at different time points (3, 6, 12, 18 or 24 h). Testicular cells were harvested for experiments. H202 and NO concentrations, and Ca2+-ATPase activity were detected by biochemical assays, the calcium ion concentration ([Ca2+]i) by flow cytometry using fluo-3 probe, and GRP78 mRNA and protein expressions by quantitative real-time RT-PCR (qRT-PCR) and Western blotting, respectively. The mRNA expressions of S-XBP1, JNK, caspase-12 and CHOP were measured by qRT-PCR, and the protein expressions of IREla, S-XBP1, p-PERK, p-elF2a, ATF6 p50, p-JNK, pro-caspase-12, cleaved caspase-12 and CHOP by Western blot- ting. The results showed that the concentrations of H202 and NO, the mR_NA expressions of GRP78, S-XBP1, JNK, caspase-12 and CHOP, and the protein expressions of GRP78, S-XBP1, IREla, p-PERK, p-elF2a, ATF6 p50, p-JNK, pro-caspase-12, cleaved caspase-12 and CHOP were significantly increased in a time- and dose-dependent manner after LDR. But the [Ca2]i and Ca2-ATPase activities were sig nificantly decreased in a time and dose-dependent manner. It was concluded that the ERS, regulated by IRE 1, PERK and ATF6 pathways, is involved in the apoptosis of testicular cells in LDR mice, which is associated with ERS-apoptotic signaling molecules of JNK, caspase-12 and CHOP. 展开更多
关键词 low dose radiation testicular cells endoplasmic reticulum stress APOPTOSIS SIGNALINGPATHWAY
下载PDF
Slice-wise reconstruction for low-dose cone-beam CT using a deep residual convolutional neural network 被引量:4
13
作者 Hong-Kai Yang Kai-Chao Liang +1 位作者 Ke-Jun Kang Yu-Xiang Xing 《Nuclear Science and Techniques》 SCIE CAS CSCD 2019年第4期53-61,共9页
Because of the growing concern over the radiation dose delivered to patients, X-ray cone-beam CT(CBCT) imaging of low dose is of great interest. It is difficult for traditional reconstruction methods such as Feldkamp ... Because of the growing concern over the radiation dose delivered to patients, X-ray cone-beam CT(CBCT) imaging of low dose is of great interest. It is difficult for traditional reconstruction methods such as Feldkamp to reduce noise and keep resolution at low doses. A typical method to solve this problem is using optimizationbased methods with careful modeling of physics and additional constraints. However, it is computationally expensive and very time-consuming to reach an optimal solution. Recently, some pioneering work applying deep neural networks had some success in characterizing and removing artifacts from a low-dose data set. In this study,we incorporate imaging physics for a cone-beam CT into a residual convolutional neural network and propose a new end-to-end deep learning-based method for slice-wise reconstruction. By transferring 3D projection to a 2D problem with a noise reduction property, we can not only obtain reconstructions of high image quality, but also lower the computational complexity. The proposed network is composed of three serially connected sub-networks: a cone-to-fan transformation sub-network, a 2D analytical inversion sub-network, and an image refinement sub-network. This provides a comprehensive solution for end-to-end reconstruction for CBCT. The advantages of our method are that the network can simplify a 3D reconstruction problem to a 2D slice-wise reconstruction problem and can complete reconstruction in an end-to-end manner with the system matrix integrated into the network design. Furthermore, reconstruction can be less computationally expensive and easily parallelizable compared with iterative reconstruction methods. 展开更多
关键词 CONE-BEAM CT Slice-wise RESIDUAL U-net low dose Image DENOISING
下载PDF
Correlation between Low Tube Voltage in Dual Source CT Coronary Artery Imaging with Image Quality and Radiation Dose 被引量:6
14
作者 雷子乔 韩萍 +2 位作者 徐海波 余建明 刘红利 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第4期616-620,共5页
The influence of low tube voltage in dual source CT(DSCT) coronary artery imaging on image quality and radiation dose and its application value in clinical practice were investigated. Totally, 300 cases of chest pai... The influence of low tube voltage in dual source CT(DSCT) coronary artery imaging on image quality and radiation dose and its application value in clinical practice were investigated. Totally, 300 cases of chest pain with low body mass index(BMI 〈18.5 kg/m2) subjected to DSCT coronary artery imaging were prospectively enrolled. The heart rate in all patients were greater than 65/min. The retrospective ECG gated scanning mode and simple random sampling method were used to assign the patients into groups A, B and C(n=100 each). The patients in groups A, B and C experienced 120-, 100-, and 80-kV tube voltage imaging respectively, and the image quality was evaluated. The CT volume dose index(CTDIvol) and dose length product(DLP) were recorded, and the effective dose(ED) was calculated in each group. The image quality scores and radiation doses in groups were compared, and the influence of tube voltage on image quality and radiation dose was analyzed. The results showed that the excellent rate of image quality in groups A, B and C was 95.69%, 94.72% and 96.33% respectively with the difference being not statistically significant among the three groups(P〉0.05). The CTDIvol values in groups A, B and C were 51.35±12.21, 21.28±7.13 and 6.34±3.34 mGy, respectively, with the difference being statistically significant(P〈0.05). The ED values in groups A, B and C were 9.27±1.63, 4.56±2.29 and 2.29±1.69 mSv, respectively, with the difference being statistically significant(P〈0.05). It was suggested that for the patients with low BMI, the application of DSCT coronary artery imaging with low tube voltage can obtain satisfactory image quality, and simultaneously, significantly reduce the radiation dose. 展开更多
关键词 dual source CT coronary angiography TOMOGRAPHY radiation dose low body mass index
下载PDF
Increased Levels of p53 and PARP-1 in EL-4 Cells Probably Related with the Immune Adaptive Response Induced by Low Dose Ionizing Radiation in vitro 被引量:6
15
作者 GUANG-HUI CHENG NING WU +4 位作者 DE-Fu JIANG HONG-GUANG ZHAO QIAN ZHANG JIAN-FENG WANG SHou-LIANG GONG 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2010年第6期487-495,共9页
Objective This paper is to explore the DNA repair mechanism of immune adaptive response (AR) induced by low dose radiation (LDR), the changes of mRNA levels and protein expressions of p53, ATM, DNA-PK catalytic su... Objective This paper is to explore the DNA repair mechanism of immune adaptive response (AR) induced by low dose radiation (LDR), the changes of mRNA levels and protein expressions of p53, ATM, DNA-PK catalytic subunit (DNA-PKcs) and PARP-1 genes in the LDR-induced AR in EL-4 cells. Methods The apoptosis and cell cycle progression of EL-4 cells were detected by flow cytometry in 12 h after the cells received the pre-exposure of 0.075 Gy X-rays (inductive dose, D 1) and the succeeding high dose irradiation (challenge dose, D2; 1.0, 1.5, and 2.0 Gy X-rays, respectively) with or without wortmannin (inhibitor of ATM and DNA-PK) and 3-aminobenzamid (inhibitor of PARP-1). And the protein expressions and mRNA levels related to these genes were detected with flow cytometry and reverse transcription-polymerase chain reaction in 12 h after irradiation with D2. Results The mRNA and protein expressions of p53 and PARP-1 in EL-4 cells in the D1 + D2 groups were much lower than those in the D2 groups, and those of PARP-1 in the 3-AB + D2 and the 3-AB + D1 + D2 groups were much lower than those in the D2 and the D1 + D2 groups. The percentage of apoptotic EL-4 cells in the 3-AB + D1 + D2 groups was much higher than that in the D1 + D2 groups, that in the G0/G1 and the G2 + M phases was much higher, and that in the S phase were much lower. Although the ATM and DNA-PKcs mRNA and protein expressions in wortmannin + D1 + D2 groups were much lower than those in the D1 + D2 groups, there were no significant changes in the apoptosis and cell cycle progression between the wortmannin + D1 + D2 and the D1 + D2 groups. Conclusion PARP-1 and p53 might play important roles in AR induced by LDR. 展开更多
关键词 low dose radiation (LDR) Adaptive response (AR) DNA repair
下载PDF
Low contrast medium and radiation dose for hepatic computed tomography perfusion of rabbit VX2 tumor 被引量:2
16
作者 Cai-Yuan Zhang Yan-Fen Cui +4 位作者 Chen Guo Jing Cai Ya-Fang Weng Li-Jun Wang Deng-Bin Wang 《World Journal of Gastroenterology》 SCIE CAS 2015年第17期5259-5270,共12页
AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning... AIM:To evaluate the feasibility of low contrast medium and radiation dose for hepatic computed tomography(CT) perfusion of rabbit VX2 tumor.METHODS:Eleven rabbits with hepatic VX2 tumor underwent perfusion CT scanning with a 24-h interval between a conventional tube potential(120 k Vp) protocol with 350 mg I/m L contrast medium and filtered back projection,and a low tube potential(80 k Vp) protocol with 270 mg I/m L contrast medium with iterative reconstruction.Correlation and agreement among perfusion parameters acquired by the conventional and low dose protocols were assessed for the viable tumor component as well as whole tumor.Image noise and tumor-to-liver contrast to noise ratio during arterial and portal venous phases were evaluated.RESULTS:A 38% reduction in contrast medium dose(360.1 ± 13.3 mg I/kg vs 583.5 ± 21.5 mg I/kg,P < 0.001) and a 73% decrease in radiation dose(1898.5 m Gy·cm vs 6951.8 m Gy·cm) were observed.Interestingly,there was a strong positive correlation in hepatic arterial perfusion(r = 0.907,P < 0.001;r = 0.879,P < 0.001),hepatic portal perfusion(r = 0.819,P = 0.002;r = 0.831,P = 0.002),and hepatic blood flow(r = 0.945,P < 0.001;r = 0.930,P < 0.001) as well as a moderate correlation in hepatic perfusion index(r = 0.736,P = 0.01;r = 0.636,P = 0.035) between the low dose protocol with iterative reconstruction and the conventional protocol for the viable tumor component and the whole tumor.These two imaging protocols provided a moderate but acceptable agreement for perfusion parameters and similar tumorto-liver CNR during arterial and portal venous phases(5.63 ± 2.38 vs 6.16 ± 2.60,P = 0.814;4.60 ± 1.27 vs 5.11 ± 1.74,P = 0.587).CONCLUSION:Compared with the conventional protocol,low contrast medium and radiation dose with iterative reconstruction has no significant influence on hepatic perfusion parameters for rabbits VX2 tumor. 展开更多
关键词 low radiation dose low concentrationcontrast MEDIUM PERFUSION COMPUTED tomography Liver VX2 tumor
下载PDF
A retrospective analysis of the safety and efficacy of low dose tacrolimus (FK506) for living donor liver transplant recipients 被引量:3
17
作者 Zhengshan Wu Qingyang Meng +2 位作者 Yongxiang Xia Feng Zhang Wei You 《The Journal of Biomedical Research》 CAS 2013年第4期305-309,共5页
We sought to evaluate the efficacy and effects of low-dose tacrolimus (FK506) to recipients with living donor liver transplantation (LDLT). A total of 66 patients who underwent LDLT between 2001 and 2007 were enro... We sought to evaluate the efficacy and effects of low-dose tacrolimus (FK506) to recipients with living donor liver transplantation (LDLT). A total of 66 patients who underwent LDLT between 2001 and 2007 were enrolled in this study. According to different doses of tacrolimus, the recipients were randomly divided into two groups: the low-dose tacrolimus group (group A) and the normal-dose tacrolimus group (group B). The blood concentration of tacrolimus and its side effects including infection, hyperglycemia, hypertension, high blood creatinine and jaundice were monitored once a week at the perioperative period, and once a month thereafter. Besides, the survival rates of the recipients were analyzed at the 1and 3-year time point after operation. Among these patients, no significant acute rejection was detected after LDLT. The incidences of infection, hyperglycemia, liver dysfunction and renal impairment in group A were markedly lower than those in group B. However, no significant differences were detected in the incidence of hypertension between the two groups. Moreover, the recipients in each group had a similar survival rate according to the results of 1and 3-year follow-up. The incidence of side effects that associated with tacrolimus positively correlated with tacrolimus blood concentration. In conclusion, long-term and low-dose administration of tacrolimus is a safe and effective treatment for LDLT recipients. 展开更多
关键词 living donor liver transplantation TACROLIMUS low dose side effect survival rate
下载PDF
Current status of low dose multi-detector CT in the urinary tract 被引量:4
18
作者 Mi Kim Sung Sarabjeet Singh Mannudeep K Kalra 《World Journal of Radiology》 CAS 2011年第11期256-265,共10页
Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems ca... Over the past several years,advances in the technical domain of computed tomography(CT) have influenced the trend of imaging modalities used in the clinical evaluation of the urinary system.Renal collecting systems can be illustrated more precisely with the advent of multi-detector row CT through thinner slices,high speed acquisitions,and enhanced longitudinal spatial resolution resulting in improved reformatted coronal images.On the other hand,a significant increase in exposure to ionizing radiation,especially in the radiosensitive organs,such as the gonads,is a concern with the increased utilization of urinary tract CT.In this article,we discuss the strategies and techniques availablefor reducing radiation dose for a variety of urinary tractCT protocols with metabolic clinical examples.We also reviewed CT for hematuria evaluation and related scan parameter optimization such as,reducing the number of acquisition phases,CT angiography of renal donors and lowering tube potential,when possible. 展开更多
关键词 HEMATURIA evaluation low dose COMPUTEDTOMOGRAPHY Multi-detector row COMPUTED TOMOGRAPHY Renal donor COMPUTED TOMOGRAPHY angiography Urinary TRACT imaging
下载PDF
Value of low-dose and optimized-length computed tomography(CT)scan in CT-guided percutaneous transthoracic needle biopsy of pulmonary nodules 被引量:6
19
作者 Hui Yuan Da Li +2 位作者 Yan Zhang Xiaozhen Xie Lujun Shen 《Journal of Interventional Medicine》 2021年第3期143-148,共6页
Objective:To investigate the value of application of low-dose and optimized length CT scan on puncture results,complications and patients’radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules(PTN... Objective:To investigate the value of application of low-dose and optimized length CT scan on puncture results,complications and patients’radiation dosage during CT-guided percutaneous biopsy of pulmonary nodules(PTNB).Methods:A total of 231 patients with PTNB under CT guidance were collected.Low dose scanning utilized tube current of 20 mA as compared with 40 mA in conventional dosage.Optimized length in CT is defined as intentionally narrowing the range of CT scanning just to cover 25 mm(5 layers)around the target layer during needle adjustment.According to whether low-dose scans and optimized length scans techniques were utilized,patients were divided into three groups:conventional group(conventional sequence+no optimization),optimized length group(conventional sequence+optimized length),and low-dose optimized length group(low dose sequence+optimized length).The ED(effective dose),the DLP(dose length product),the average CTDIvol(Volume CT dose index),total milliampere second between subgroups were compared.Results:Compared with the conventional group,ED,intraoperative guidance DLP,total milliseconds and operation time in the optimized length group were reduced by 18.2%(P=0.01),37%(P=0.003),17.5%(P=0.013)and13.3%(P=0.021)respectively.Compared with the optimized length group,the ED was reduced by 87%,preoperative positioning,intraoperative guidance and postoperative review DLP were also reduced by 88%,total milliampere second was reduced by 79%,with an average CTDIvol was reduced by 86%,in the low-dose optimized length group(P<0.001 for all).Conclusion:Optimizing the length during CT scanning can effectively reduce the intraoperative radiation dose and reduce the operation time compared with conventional plan;low-dose and optimized length CT scan can further reduce the total radiation dose compared with optimized length group with no differences on intraoperative complications,biopsy results and operation time. 展开更多
关键词 Lung biopsy CT guided low dose Radiation dose Optimized scan
下载PDF
INVOLVEMENT OF THE Ca^(2+) PROTEIN KINASE C AND ADENYLATE CYCLACE SIGNAL PATHWAYS IN THE ACTIVATION OF THYMOCYTES IN RESPONSE TO WHOLE BODY IRRADIATION WITH LOW DOSE X RAYS 被引量:8
20
作者 刘树铮 谢风 《Chinese Medical Sciences Journal》 CAS CSCD 2000年第1期1-7,共7页
WT5”BZ] To study the molecular mechanism of the stimulatory effect of low dose radiation(LDR) on T cell activation. [WT5”BX]Methods.[WT5”BZ] Thymocytes from Kunming mice exposed to whole body irradiation(WBI) with ... WT5”BZ] To study the molecular mechanism of the stimulatory effect of low dose radiation(LDR) on T cell activation. [WT5”BX]Methods.[WT5”BZ] Thymocytes from Kunming mice exposed to whole body irradiation(WBI) with different doses of X rays were analyzed for the changes in signal molecules of the phospholipase C phosphatidylinositol biphosphate(PLC IP2) and G protein adenylate cyclase(AC) pathways. [WT5”BX]Results.[WT5”BZ]It was found that[Ca 2+ ] i increased in response to doses within 0 2 Gy which was most marked after 0 075 Gy and the increase was accentuated in the presence of Con A. The changes in CD3 and calcineurin(CN) expression of the thymocytes followed the same pattern as the alterations in [Ca 2+ ] i after LDR. The expression of α,β1 and β2 isoforms of protein kinase C(PKC) was all up regulated after 0 075 Gy with the increase in PKC β1 expression being most marked. The cAMP/cGMP ratio and PKA activity of the thymocytes was lowered after low dose radiation and increased after doses above 0 5 Gy in a dose dependent manner, thus giving rise to J shaped dose response curves. The Ca antagonist TMB 8 and cAMP stimulant cholera toxin suppressed the augmented thymocyte proliferation induced by LDR. [WT5”BX]Conclusion.[WT5”BZ]Data presented in the present paper suggest that activation of the PLC PIP2 signal pathway and suppression of the AC cAMP signal pathway are involved in the stimulation of the thymocytes following WBI with low dose X rays. 展开更多
关键词 WT5BZ]low dose radiation intracellular Ca^(2+) PKC isoforms cAMP/cGMP ratio
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部