To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an impr...To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.展开更多
For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving e...For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.展开更多
The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The resul...The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water.展开更多
To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) metho...To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.展开更多
An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the ...An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.展开更多
Low temperature heat adsorption pumps represent the innovative cooling systems, where cold is generated through adsorption/desorption cycle of water by a suitable adsorbent with good adsorption and high thermal conduc...Low temperature heat adsorption pumps represent the innovative cooling systems, where cold is generated through adsorption/desorption cycle of water by a suitable adsorbent with good adsorption and high thermal conductive properties. In this work, the hydrothermal synthesis of zeolite SAPO-34 on thermal conductive grapbitic supports, aiming at the development of highly pertbrming adsorbent materials, is reported. The synthesis was carried out using as-received and oxidized commercial carbon papers, and graphite plate. Composites were characterized by XRD, SEM and also by a thermogravimetric method, using a Cahn microbalance. The water adsorbing capacity showed typical S-shape trend and the maximum water loading was around 25 wt%, a value close to water adsorption capability of pure SAPO-34. These results are very promising for their application in heat adsorption pumps.展开更多
The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy source...The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy sources and its conversion to useful electrical power. The thermal performance analysis is based on the utilization of R-123, R-134a, R-290, R-245fa, R-1234ze-E, and R-1233zd-E fluids in a simple organic Rankine cycle (SORC). A waste energy source from an industrial sector is suggested to be available at a temperature greater than 110 °C. A hypothetical organic Rankine cycle of 10 kW nominal heat recovery was implemented to evaluate the cycle performance. It operates at evaporation and condensation temperatures of 90 °C and 45 °C, respectively. The selected vapor superheat degree at the expander entrance was 5 °C - 15 °C, and the liquid was subcooled by 5 °C at the discharge port of condenser. The estimated first law cycle thermal efficiency fell in the range of 6.4% - 7.7%. The results showed that the thermal efficiencies of R-134a, R-123, R-245fa, R-1233zd-E, and R-1234ze-E were higher than that of R-290 by 10% - 14%, 11% - 12%, 9% - 12%, 4% - 7% and 1% - 3%, respectively. R-1233zd-E, R-1234ze-E, and R-290 showed close thermal efficiency values, and it fell in the range of 6.7% - 7% for the (SORC) at a superheat degree of 15 °C. At the same superheat degree, the corresponding range of thermal efficiency for R-134a, R-123 and R-245fa fell within 7.5% - 7.7%. R-134a possessed the highest net power output of the (SORC);it reached a value of 0.91 kW as predicted at 15 °C superheat degree. Increasing the expander volumetric efficiency value by 10% improved the cycle thermal efficiency by 10% - 12%.展开更多
The amount of low-temperature heat generated in industrial processes is high,but recycling is limited due to low grade and low recycling efficiency,which is one of the reasons for low energy efficiency.It implies that...The amount of low-temperature heat generated in industrial processes is high,but recycling is limited due to low grade and low recycling efficiency,which is one of the reasons for low energy efficiency.It implies that there is a great potential for low-temperature heat recovery and utilization.This article provided a detailed review of recent advances in the development of low-temperature thermal upgrades,power generation,refrigeration,and thermal energy storage.The detailed description will be given from the aspects of system structure improvement,work medium improvement,and thermodynamic and economic performance evaluation.It also pointed out the development bottlenecks and future development trends of various technologies.The low-temperature heat combined utilization technology can recover waste heat in an all-round and effective manner,and has great development prospects.展开更多
This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system....This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.展开更多
During air injection into an oil reservoir,an oxidation reaction generates some heat to raise the reservoir temperature.When the reservoir temperature reaches an ignition temperature,spontaneous ignition occurs.There ...During air injection into an oil reservoir,an oxidation reaction generates some heat to raise the reservoir temperature.When the reservoir temperature reaches an ignition temperature,spontaneous ignition occurs.There is a time delay from the injection to ignition.There are mixed results regarding the feasibility of spontaneous ignition in real-field projects and in laboratory experiments.No analytical model is available in the literature to estimate the oxidation time required to reach spontaneous ignition with heat loss.This paper discusses the feasibility of spontaneous ignition from theoretical points and experimental and field project observations.An analytical model considering heat loss is proposed.Analytical models with and without heat loss investigate the factors that affect spontaneous ignition.Based on the discussion and investigations,we find that it is more difficult for spontaneous ignition to occur in laboratory experiments than in oil reservoirs;spontaneous ignition is strongly affected by the initial reservoir temperature,oil activity,and heat loss;spontaneous ignition is only possible when the initial reservoir temperature is high,the oil oxidation rate is high,and the heat loss is low.展开更多
A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of...A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.展开更多
This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the conditi...This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment.展开更多
文摘To enhance system stability,solar collectors have been integrated with air-source heat pumps.This integration facilitates the concurrent utilization of solar and air as energy sources for the system,leading to an improvement in the system’s heat generation coefficient,overall efficiency,and stability.In this study,we focus on a residential building located in Lhasa as the target for heating purposes.Initially,we simulate and analyze a solar-air source heat pump combined heating system.Subsequently,while ensuring the system meets user requirements,we examine the influence of solar collector installation angles and collector area on the performance of the solar-air source heat pump dual heating system.Through this analysis,we determine the optimal installation angle and collector area to optimize system performance.
基金This work was supported by the National Key Research and Development Program of China(No.2019YFE0193200 KY202001)Science and Technology Planning Project of Beijing(No.Z201100008320001 KY191004).
文摘For heating systems based on electricity storage coupled with solar energy and an air source heat pump(ECSA),choosing the appropriate combination of heat sources according to local conditions is the key to improving economic efficiency.In this paper,four cities in three climatic regions in China were selected,namely Nanjing in the hot summer and cold winter region,Tianjin in the cold region,Shenyang and Harbin in the severe cold winter region.The levelized cost of heat(LCOH)was used as the economic evaluation index,and the energy consumption and emissions of different pollutants were analyzed.TRNSYS software was used to simulate and analyze the system performance.The Hooke-Jeeves optimization algorithm and GenOpt software were used to optimize the system parameters.The results showed that ECSA systemhad an excellent operation effect in cold region and hot summer and cold winter region.Compared with ECS system,the systemenergy consumption,and the emission of different pollutants of ECSA system can be reduced by a maximum of 1.37 times.In cold region,the initial investment in an air source heat pump is higher due to the lower ambient temperature,resulting in an increase in the LOCH value of ECSA system.After the LOCH value of ECSA system in each region was optimized,the heating cost of the system was reduced,but also resulted in an increase in energy consumption and the emission of different pollutant gases.
基金Supported by Scientific Research Fund of Ningxia University [(E) ndzr09-23]
文摘The principle and development prospect of air source heat pump water heat were introduced,as well as the designation of condenser (storage water tank),experimental study on installations was also carried out.The results showed that air source heat pump water heater was superior to conventional system.Under the operation of cooling and heating,heat pump comprehensive utilization equipment could improve heating performance,reduce energy consumption,and recycle condensing heat to provide hot water.
基金Project(50606007) supported by the National Natural Science Foundation of China
文摘To solve the fundamental problem of insufficient heat available during defrosting while ensuring the efficient and safe system operation for air-source heat pumps (ASHPs). A novel reverse-cycle defrosting (NRCD) method based on thermal energy storage to eliminate frost off the outdoor coil surface was developed. Comparative experiments using both the stand reverse cycle defrosting (SRCD) method and the NRCD method were carried out on an experimental ASHP unit with a nominal 2.5 kW heating capacity. The results indicate that during defrosting operation, using the NRCD method improves discharge and suction pressures by 0.24 MPa and 0.19 MPa, respectively, shortens defrosting duration by 60%, and reduces the defrosting energy consumption by 48.1% in the experimental environment, compared with those by the use of SRCD method. Therefore, using the NRCD method can shorten the defrosting duration, improve the indoor thermal comfort, and reduce the defrosting energy consumption in defrosting.
基金Supported bythe"11th Five-Year Plan"for National Plans of Major Technology Projects
文摘An air source heat pump system (ASHPS) used in an office building is set up and studied experimentally. Its operating performance in winter is evaluated based on test data and a comparative discussion is given on the effect of climate conditions and heating load ratio on the operation behavior. Then heating capacity variation caused by evaporator frosting is analyzed as well. Finally, the defrosting parameters and the technical feasibility are studied for a constant heating demand. The experimental results indicate that both the outlet water temperature drop and the system COP should be taken into account when setting defrosting parameters, and ASHPS is a viable technology for space heating and hot-water production in winter in Tianjin, which can maintain the room temperature above 19 ℃ when the outdoor temperature is -2 ℃.
基金partially funded by "Fondo per la Ricerca per il Sistema Elettrico-AdP MSE-CNR"
文摘Low temperature heat adsorption pumps represent the innovative cooling systems, where cold is generated through adsorption/desorption cycle of water by a suitable adsorbent with good adsorption and high thermal conductive properties. In this work, the hydrothermal synthesis of zeolite SAPO-34 on thermal conductive grapbitic supports, aiming at the development of highly pertbrming adsorbent materials, is reported. The synthesis was carried out using as-received and oxidized commercial carbon papers, and graphite plate. Composites were characterized by XRD, SEM and also by a thermogravimetric method, using a Cahn microbalance. The water adsorbing capacity showed typical S-shape trend and the maximum water loading was around 25 wt%, a value close to water adsorption capability of pure SAPO-34. These results are very promising for their application in heat adsorption pumps.
文摘The low-grade heat source recovery is usually constrained by the physical characteristics of the hot fluid medium. The present work focuses on the importance of energy recovery from low-temperature waste energy sources and its conversion to useful electrical power. The thermal performance analysis is based on the utilization of R-123, R-134a, R-290, R-245fa, R-1234ze-E, and R-1233zd-E fluids in a simple organic Rankine cycle (SORC). A waste energy source from an industrial sector is suggested to be available at a temperature greater than 110 °C. A hypothetical organic Rankine cycle of 10 kW nominal heat recovery was implemented to evaluate the cycle performance. It operates at evaporation and condensation temperatures of 90 °C and 45 °C, respectively. The selected vapor superheat degree at the expander entrance was 5 °C - 15 °C, and the liquid was subcooled by 5 °C at the discharge port of condenser. The estimated first law cycle thermal efficiency fell in the range of 6.4% - 7.7%. The results showed that the thermal efficiencies of R-134a, R-123, R-245fa, R-1233zd-E, and R-1234ze-E were higher than that of R-290 by 10% - 14%, 11% - 12%, 9% - 12%, 4% - 7% and 1% - 3%, respectively. R-1233zd-E, R-1234ze-E, and R-290 showed close thermal efficiency values, and it fell in the range of 6.7% - 7% for the (SORC) at a superheat degree of 15 °C. At the same superheat degree, the corresponding range of thermal efficiency for R-134a, R-123 and R-245fa fell within 7.5% - 7.7%. R-134a possessed the highest net power output of the (SORC);it reached a value of 0.91 kW as predicted at 15 °C superheat degree. Increasing the expander volumetric efficiency value by 10% improved the cycle thermal efficiency by 10% - 12%.
基金Supported by the National Natural Science Foundation of China(21476119,21406124)Major Science and Technology Innovation Project of Shandong Province(2018CXGC1102).
文摘The amount of low-temperature heat generated in industrial processes is high,but recycling is limited due to low grade and low recycling efficiency,which is one of the reasons for low energy efficiency.It implies that there is a great potential for low-temperature heat recovery and utilization.This article provided a detailed review of recent advances in the development of low-temperature thermal upgrades,power generation,refrigeration,and thermal energy storage.The detailed description will be given from the aspects of system structure improvement,work medium improvement,and thermodynamic and economic performance evaluation.It also pointed out the development bottlenecks and future development trends of various technologies.The low-temperature heat combined utilization technology can recover waste heat in an all-round and effective manner,and has great development prospects.
基金Supported by Hubei Provincial Natural Science Foundation(2008CDB363)
文摘This paper simulated the optimal refrigerant charge inventory of a refrigeration system in air-conditioning operation and heat-pump operation respectively,and studied the refrigerant control strategies in this system.The void fraction in two-phase fluid region was calculated by Harms model.And based on distributed parameter model and Harms model,the refrigerant charge inventory in condenser and evaporator were calculated and analyzed in air-conditioning conditions and heat-pump conditions,respectively.The calculating results of different refrigerant mass between refrigeration and heating conditions indicate that the optimal refrigerant charge inventory in heat-pump conditions is lower than that in air-conditioning conditions.To avoid the decrease of COP due to the surplus refrigerant in heating conditions,we introduced the liquid reservoir control method and associate capillary control method.Both of them could increase the heating capacity of the air-source heat pump.The difference of optimal refrigerant charge inventory in air-conditioning and heat-pump system can be controlled by the liquid reservoir or the associate capillary.
基金supported by the National Natural Science Foundation of China (No.51974334)Hainan Province Science and Technology Special Fund (ZDYF2022SHFZ107)local efficient reform and development funds for personnel training projects supported by the central government,Heilongjiang Postdoctoral Scientific Research Fund (LBH-Q21012)。
文摘During air injection into an oil reservoir,an oxidation reaction generates some heat to raise the reservoir temperature.When the reservoir temperature reaches an ignition temperature,spontaneous ignition occurs.There is a time delay from the injection to ignition.There are mixed results regarding the feasibility of spontaneous ignition in real-field projects and in laboratory experiments.No analytical model is available in the literature to estimate the oxidation time required to reach spontaneous ignition with heat loss.This paper discusses the feasibility of spontaneous ignition from theoretical points and experimental and field project observations.An analytical model considering heat loss is proposed.Analytical models with and without heat loss investigate the factors that affect spontaneous ignition.Based on the discussion and investigations,we find that it is more difficult for spontaneous ignition to occur in laboratory experiments than in oil reservoirs;spontaneous ignition is strongly affected by the initial reservoir temperature,oil activity,and heat loss;spontaneous ignition is only possible when the initial reservoir temperature is high,the oil oxidation rate is high,and the heat loss is low.
基金the National Natural Science Foundation of China(No.51776117)。
文摘A new type of microchannel condenser applied in the air source heat pump water heater(ASHPWH)with cyclic heating was proposed in this study.The operating performance of the ASHPWH was frst tested.Then,the structure of the microchannel condenser was optimized with the implement of vortex generators.Finally,a numerical model of the ASHPWH was established and the optimized microchannel condenser was studied.The experimental results showed that the average coefficient of performance(COP)of the 1HP(735 W)ASHPWH reached 3.48.In addition,the optimized microchannel condenser could be matched with a 3 HP(2430W)ASHPWH with an average heating capacity of 10.30 kW,and achieving an average COP of 4.24,14.6%higher than the limit value in the national standard.
文摘This paper uses FLUENT software building the three-dimensional unsteady state model of ground source heat pump single U and double U underground pipe to study on heat exchange of underground pipe system in the condition of unsteady state long-term continuous running, analyzes the change of soil temperature filed around underground pipe and performance of underground pipe heat exchange between single U and double U pipe system. The results show that double U pipe system is better than single U system, which can improve unit depth heat exchange efficiency, reduce the number of wells and reduce the initial investment.