AIM To evaluate the safety and feasibility of a new technology combining low-pressure pneumoperitoneum(LPP) and abdominal wall lift(AWL) in laparoscopic total mesorectal excision(TME) for rectal cancer.METHODS From No...AIM To evaluate the safety and feasibility of a new technology combining low-pressure pneumoperitoneum(LPP) and abdominal wall lift(AWL) in laparoscopic total mesorectal excision(TME) for rectal cancer.METHODS From November 2015 to July 2017,26 patients underwent laparoscopic TME for rectal cancer using LPP(6-8 mm Hg) with subcutaneous AWL in Qilu Hospital of Shandong University,Jinan,China.Clinical data regarding patients' demographics,intraoperative monitoring indices,operation-related indices andpathological outcomes were prospectively collected.RESULTS Laparoscopic TME was performed in 26 cases(14 anterior resection and 12 abdominoperineal resection) successfully,without conversion to open or laparoscopic surgery with standard-pressure pneumoperitoneum.Intraoperative monitoring showed stable heart rate,blood pressure and paw airway pressure.The mean operative time was 194.29 ± 41.27 min(range:125-270 min) and 200.41 ± 20.56 min(range:170-230 min) for anterior resection and abdominoperineal resection,respectively.The mean number of lymph nodes harvested was 16.71 ± 5.06(range:7-27).There was no positive circumferential or distal resection margin.No local recurrence was observed during a median follow-up period of 11.96 ± 5.55 mo(range:5-23 mo).CONCLUSION LPP combined with AWL is safe and feasible for laparoscopic TME.The technique can provide satisfactory exposure of the operative field and stable operative monitoring indices.展开更多
Styrene-acrylate latex with high glass transition temperature (T), low minimum film forming temperature(MFT) and good stability was prepared via core-shell emulsion polymerization. With semicontinuous process, hig...Styrene-acrylate latex with high glass transition temperature (T), low minimum film forming temperature(MFT) and good stability was prepared via core-shell emulsion polymerization. With semicontinuous process, high conversion rate of monomer and low gel rate were achieved. The weight ratio of core monomer to shell monomer was approximately 1.35. It is found that many factors such as emulsifiers, initiators, reaction temperature, pH value and polymerization technology have influences on the permormance of styrene-acrylate latex. The prepared latex was characterized by TEM and FTIR. The obtained latex with T of 20.57 ℃, MFT or5.0 ℃, and good stability, had good stability of film forming.展开更多
The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-indu...The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-induced spectral filtering effect, the dual-wavelength lasing operation can be achieved. In order to enhance the cross coupling effect between the two lasing beams for domain wall pulse formation, a 215-m HNLF is incorporated into the laser cavity. Experimentally, it is found that the dual-wavelength domain wall pulse with a repetition rate of 77.67 kHz could be efficiently obtained through simply rotating the polarization controller (PC). At a maximum pump power of 322 mW, the 655-nJ single pulse energy in cavity is obtained. The proposed configuration provides a simpler and more efficient way to generate high energy pulse with a low repetition rate.展开更多
Microwave-absorbing polymeric composites based on single-walled carbon nanotubes (SWNTs) are fabricated via a simple yet versatile method, and these SWNT-epoxy composites exhibit very impressive microwave absorption...Microwave-absorbing polymeric composites based on single-walled carbon nanotubes (SWNTs) are fabricated via a simple yet versatile method, and these SWNT-epoxy composites exhibit very impressive microwave absorption perfor- mances in a range of 2 GHz-18 GHz. For instance, a maximum absorbing value as high as 28 dB can be achieved for each of these SWNT-epoxy composites (1.3-mm thickness) with only 1 wt% loading of SWNTs, and about 4.8 GHz bandwidth, corresponding to a microwave absorption performance higher than 10 dB, is obtained. Furthermore, such low and appro- priate loadings of SWNTs also enhance the mechanical strength of the composite. It is suggested that these remarkable results are mainly attributable to the excellent intrinsic properties of SWNTs and their homogeneous dispersion state in the polymer matrix.展开更多
The work compared the differences of low fiber mutation rice (LF, Nendao) that selectedthrough gamma-ray (γ) with parental variety Shuangkezao (CK) on their biologicaldevelopment and cell wall composing after rice he...The work compared the differences of low fiber mutation rice (LF, Nendao) that selectedthrough gamma-ray (γ) with parental variety Shuangkezao (CK) on their biologicaldevelopment and cell wall composing after rice heading stage. Comparing with parentalrice, LF rice revealed an advantage on its vegetative growing by increasing the yieldsof leave blade, leave sheath and stem for 27.77, 30.19 and 37.96% respectively. And thecellulose content of LF rice straw was decreased remarkably for 23.9%, the hemicellulose,lignin and biogenic silicon contents were increased contrarily for 11.94, 8.79 and 5.60%respectively. Moreover, the crude protein content was increased by 20.71% for LF rice andwith an improvement on its solubility for 63.49% concomitantly. The results indicatedthat the low-fiber mutation rice exhibited its potential as a fodder-rice variety or asdual-purpose rice to improve fiber degradability of straw.展开更多
The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry...The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak.展开更多
基金Supported by the Special Found for Taishan Scholar Project of Shandong Province,China
文摘AIM To evaluate the safety and feasibility of a new technology combining low-pressure pneumoperitoneum(LPP) and abdominal wall lift(AWL) in laparoscopic total mesorectal excision(TME) for rectal cancer.METHODS From November 2015 to July 2017,26 patients underwent laparoscopic TME for rectal cancer using LPP(6-8 mm Hg) with subcutaneous AWL in Qilu Hospital of Shandong University,Jinan,China.Clinical data regarding patients' demographics,intraoperative monitoring indices,operation-related indices andpathological outcomes were prospectively collected.RESULTS Laparoscopic TME was performed in 26 cases(14 anterior resection and 12 abdominoperineal resection) successfully,without conversion to open or laparoscopic surgery with standard-pressure pneumoperitoneum.Intraoperative monitoring showed stable heart rate,blood pressure and paw airway pressure.The mean operative time was 194.29 ± 41.27 min(range:125-270 min) and 200.41 ± 20.56 min(range:170-230 min) for anterior resection and abdominoperineal resection,respectively.The mean number of lymph nodes harvested was 16.71 ± 5.06(range:7-27).There was no positive circumferential or distal resection margin.No local recurrence was observed during a median follow-up period of 11.96 ± 5.55 mo(range:5-23 mo).CONCLUSION LPP combined with AWL is safe and feasible for laparoscopic TME.The technique can provide satisfactory exposure of the operative field and stable operative monitoring indices.
文摘Styrene-acrylate latex with high glass transition temperature (T), low minimum film forming temperature(MFT) and good stability was prepared via core-shell emulsion polymerization. With semicontinuous process, high conversion rate of monomer and low gel rate were achieved. The weight ratio of core monomer to shell monomer was approximately 1.35. It is found that many factors such as emulsifiers, initiators, reaction temperature, pH value and polymerization technology have influences on the permormance of styrene-acrylate latex. The prepared latex was characterized by TEM and FTIR. The obtained latex with T of 20.57 ℃, MFT or5.0 ℃, and good stability, had good stability of film forming.
基金supported by the National Natural Science Foundation of China(Grant Nos.11074078,61378036,61307058,11304101,and 61177077)the Specialized Research Fund for the Doctoral Program of Higher Education,China(Grant No.20094407110002)the Ph.D.Start-up Fund of the Natural Science Foundation of Guangdong Province,China(Grant No.S2013040016320)
文摘The generation of high-energy dual-wavelength domain wall pulse with a low repetition rate is demonstrated in a highly nonlinear fiber (HNLF)-based fiber ring laser. By introducing the intracavity birefringence-induced spectral filtering effect, the dual-wavelength lasing operation can be achieved. In order to enhance the cross coupling effect between the two lasing beams for domain wall pulse formation, a 215-m HNLF is incorporated into the laser cavity. Experimentally, it is found that the dual-wavelength domain wall pulse with a repetition rate of 77.67 kHz could be efficiently obtained through simply rotating the polarization controller (PC). At a maximum pump power of 322 mW, the 655-nJ single pulse energy in cavity is obtained. The proposed configuration provides a simpler and more efficient way to generate high energy pulse with a low repetition rate.
基金Project supported by the National Basic Research Program of China(Grant Nos.2012CB933401 and 2014CB643502)the National Natural Science Foundation of China(Grant Nos.21374050,51273093,and 51373078)
文摘Microwave-absorbing polymeric composites based on single-walled carbon nanotubes (SWNTs) are fabricated via a simple yet versatile method, and these SWNT-epoxy composites exhibit very impressive microwave absorption perfor- mances in a range of 2 GHz-18 GHz. For instance, a maximum absorbing value as high as 28 dB can be achieved for each of these SWNT-epoxy composites (1.3-mm thickness) with only 1 wt% loading of SWNTs, and about 4.8 GHz bandwidth, corresponding to a microwave absorption performance higher than 10 dB, is obtained. Furthermore, such low and appro- priate loadings of SWNTs also enhance the mechanical strength of the composite. It is suggested that these remarkable results are mainly attributable to the excellent intrinsic properties of SWNTs and their homogeneous dispersion state in the polymer matrix.
文摘The work compared the differences of low fiber mutation rice (LF, Nendao) that selectedthrough gamma-ray (γ) with parental variety Shuangkezao (CK) on their biologicaldevelopment and cell wall composing after rice heading stage. Comparing with parentalrice, LF rice revealed an advantage on its vegetative growing by increasing the yieldsof leave blade, leave sheath and stem for 27.77, 30.19 and 37.96% respectively. And thecellulose content of LF rice straw was decreased remarkably for 23.9%, the hemicellulose,lignin and biogenic silicon contents were increased contrarily for 11.94, 8.79 and 5.60%respectively. Moreover, the crude protein content was increased by 20.71% for LF rice andwith an improvement on its solubility for 63.49% concomitantly. The results indicatedthat the low-fiber mutation rice exhibited its potential as a fodder-rice variety or asdual-purpose rice to improve fiber degradability of straw.
基金Project supported by the National Natural Science Foundation of China(Nos.1332006,11272233,11202122,and 11411130150)the National Fundamental Research Program of China(973 Program)(No.2012CB720101)
文摘The relationship between the in the logarithmic law (log-law) region of bursting event and the low/high-speed streak a turbulent boundary layer is investigated. A tomographic time-resolved particle image velocimetry (TRPIV) system is used to measure the instantaneous three-dimensional-three-component (3D-3C) velocity field. The momentum thickness based Reynolds number is about 2 460. The topological information in the log-law region is obtained experimentally. It is found that the existence of the quadrupole topological structure implies a three-pair hairpin-like vortex packet, which is in connection with the low/high-speed streak. An idealized 3D topological model is then proposed to characterize the observed hairpin vortex packet and low/high-speed streak.