期刊文献+
共找到821篇文章
< 1 2 42 >
每页显示 20 50 100
Analysis of Recent Secure Scan Test Techniques
1
作者 Cheng Xing Sungju Park Ji Zhao 《Journal of Software Engineering and Applications》 2016年第3期91-101,共11页
Side channel attack may result in user key leakage as scan test techniques are applied for crypto-graphic chips. Many secure scan designs have been proposed to protect the user key. This paper meticulously selects thr... Side channel attack may result in user key leakage as scan test techniques are applied for crypto-graphic chips. Many secure scan designs have been proposed to protect the user key. This paper meticulously selects three current scan test techniques, analyses their advantages and disadvantages and also compares them in security and area overhead. Users can choose one of them according to the requirements and further combination can be implemented to achieve better performance. 展开更多
关键词 Side Channel Attack scan Test techniques Secure scan Designs
下载PDF
Nonlinear optical properties of [(CH3)4N]Au(dmit)2 using Z-scan technique 被引量:1
2
作者 孙香冰 任诠 +5 位作者 王新强 张光辉 杨洪亮 冯林 许东 刘智波 《Chinese Physics B》 SCIE EI CAS CSCD 2006年第11期2618-2622,共5页
The third-order optical nonlinearities of [(CH3)4N]Au(dmit)2 (dmit = 4,5-dithiolate-1,3-dithiole-2-thione) at 532 nm and 1064 nm are investigated using the Z-scan technique with pulses of picoseconds duration. T... The third-order optical nonlinearities of [(CH3)4N]Au(dmit)2 (dmit = 4,5-dithiolate-1,3-dithiole-2-thione) at 532 nm and 1064 nm are investigated using the Z-scan technique with pulses of picoseconds duration. The Z-scan spectra reveal a strong nonlinear absorption (reverse saturable absorption) and a negative nonlinear refraction at 532 nm. No nonlinear absorption is observed at 1064 nm. The molecular second-order hyperpolarizability γ for the [(CH3)4N]Au(dmit)2 molecule at 532nm is estimated to be as high as (2.1 ±0.1) × 10^-31 esu, which is nearly three times larger than that at 1064 nm. The mechanism responsible for the difference between the results is analysed. Nonlinear transmission measurements suggest that this material has potential applications in optical limiting. 展开更多
关键词 third-order optical nonlinearity organo-metallic compounds Z-scan technique
下载PDF
Effects of combining multiple dose reduction techniques on coronary computed tomography angiography
3
作者 Xiao-Lu Hu Pei-Kai Huang +2 位作者 Meng Zhang Jun Chen Meng-Qiang Xiao 《World Journal of Radiology》 2023年第2期32-41,共10页
BACKGROUND Coronary computed tomography angiography(CCTA)is the preferred noninvasive examination method for coronary heart disease.However,the radiation from computed tomography has become a concern since public awar... BACKGROUND Coronary computed tomography angiography(CCTA)is the preferred noninvasive examination method for coronary heart disease.However,the radiation from computed tomography has become a concern since public awareness of radiation hazards continue to increase.AIM To explore the value of multiple dose reduction techniques for CCTA.METHODS Consecutive normal and overweight patients were prospectively divided into two groups:Group A1,patients who received multiple dose reduction scans(n=82);and group A2,patients who received conventional scans(n=39).The scan parameters for group A1 were as follows:Isocentric scan,tube voltage=80 kV,and tube current control using 80%smart milliampere.The scan parameters for group A2 were as follows:Normal position,tube voltage=100 kV,and smart milliampere.RESULTS The average effective doses(EDs)for groups A1 and A2 were 1.13±0.35 and 3.36±1.30 mSv,respectively.There was a statistically significant difference in ED between the two groups(P<0.01).Furthermore,noise was significantly lower,and both signal-to-noise ratio and contrast signal-to-noise ratio were higher in group A2 when compared to group A1(P<0.01).Moreover,the subjective image quality(IQ)scores were excellent in both groups,in which there was no significant difference in subjective IQ score between the two groups(P=0.12).CONCLUSION Multiple dose reduction scan techniques can significantly decrease the ED of patients receiving CCTA examinations for clinical diagnosis. 展开更多
关键词 Isocentric scanning Coronary heart disease Dose reduction techniques Coronary computed tomography angiography RADIATION
下载PDF
Nonlinear optical characterization of phosphate glasses based on ZnO using the Z-scan technique
4
作者 Masoumeh Shokati Mojdehi Wan Mahmood Mat Yunus +2 位作者 Khor Shing Fhan Zainal Abidin Talib N.Tamchek 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第11期594-598,共5页
The nonlinear optical properties of a phosphate vitreous system [(ZnO)x-(MgO)30-x-(P2O5)70], where x=8, 10, 15, 18, and 20 mol% synthesized through the melt-quenching technique have been investigated by using th... The nonlinear optical properties of a phosphate vitreous system [(ZnO)x-(MgO)30-x-(P2O5)70], where x=8, 10, 15, 18, and 20 mol% synthesized through the melt-quenching technique have been investigated by using the Z-scan technique. In the experiment, a continuous-wave laser with a wavelength of 405 nm was utilized to determine the sign and value of the nonlinear refractive (NLR) index and the absorption coefficient with closed and opened apertures of the Z-scan setup. The NLR index was found to increase with the ZnO concentration in the glass samples by an order of 10-10 cm2·W-1. The real and imaginary parts of the third-order nonlinear susceptibility were calculated by referring to the NLR index (n2) and absorption coefficient (β) of the samples. The value of the third-order nonlinear susceptibility was presented by nonlinear refractive or absorptive behavior of phosphate glasses for proper utilization in nonlinear optical devices. Based on the measurement, the positive sign of the NLR index shows a self-focusing phenomenon. The figures of merit for each sample were calculated to judge the potential of phosphate glasses for application in optical switching. 展开更多
关键词 Z-scan technique nonlinear refractive index nonlinear absorption coefficient phosphate glasses
下载PDF
Z-Scan technique: To measure the total protein and albumin in blood
5
作者 A.N. Dhinaa P.K. Palanisamy 《Journal of Biomedical Science and Engineering》 2010年第3期285-290,共6页
Z-scan technique is an effective tool for measuring the optical nonlinearity of the materials. By using this technique the measurement was made for total protein and albumin. The nonlinear refractive index of the tota... Z-scan technique is an effective tool for measuring the optical nonlinearity of the materials. By using this technique the measurement was made for total protein and albumin. The nonlinear refractive index of the total protein and albumin were found to vary linearly with concentration. Hence by calculating the nonlinear refractive index it is possible to measure their concentration in the sample. The values measured thus are found in equivalence with conventional colorimetric method. 展开更多
关键词 Z-scan technique Nonlinear Refractive INDEX TOTAL PROTEIN ALBUMIN
下载PDF
Investigation on Third-Order Optical Nonlinearities of Two Organometallic Dmit2- Complexes Using Z-Scan Technique
6
作者 He-Liang Fan Quan Ren +6 位作者 Xin-Qiang Wang Ting-Bin Li Jing Sun Guang-Hui Zhang Dong Xu Gang Yu Zhi-Hua Sun 《Natural Science》 2009年第2期136-141,共6页
The third-order nonlinear optical properties of two dmit organometallic complexes, [(CH3)4N] [Au(C3S5)2] (MeAu) and [(CH3)4N][Ni(C3S5)2] (Me Ni) in acetone solutions, were characterized us- ing a short pulse Z-scan te... The third-order nonlinear optical properties of two dmit organometallic complexes, [(CH3)4N] [Au(C3S5)2] (MeAu) and [(CH3)4N][Ni(C3S5)2] (Me Ni) in acetone solutions, were characterized us- ing a short pulse Z-scan technique at 1064 nm wavelength. Self-defocusing effects were found in both samples and stronger saturable absorp-tion was observed in MeNi solution comparing with that of MeAu. The origins were analyzed for the differences between the results. Two figures of merit W and T were also calculated to evalu-ate the suitability of two materials for all-optical integrated devices. The results of W=22.84 and T≈0 of MeAu make it an excellent candidate for the all-optical applications. 展开更多
关键词 Z-scan technique THIRD-ORDER Nonlinearity Metal-dmit COMPLEXES Figure of Merit.
下载PDF
用双色Z-SCAN法研究热效应的弛豫过程 被引量:1
7
作者 贾振红 周骏 +1 位作者 傅冠久 李劬 《量子电子学报》 CAS CSCD 1997年第1期40-43,共4页
用双色Z-SCAN法研究了热效应的弛豫过程,首次给出了为得到最大的测量灵敏度所满足的泵浦光束和参考光束的几何条件.在实验上对偶氮染料有机物热弛豫时间进行了测量。
关键词 热效应 双色Z-scan 弛豫过程 泵浦光 激光
下载PDF
i-scan成像技术与碘染色对Barrett食管诊断价值和对比分析 被引量:4
8
作者 卢秀珊 张梅 +2 位作者 梁达强 谢金霞 朱柏桂 《中国医药科学》 2017年第21期177-180,共4页
目的探究i-scan成像技术与碘染色对Barrett食管诊断价值。方法选取2016年1月~2017年7月由于各种上消化道症状至我院行内镜检查而疑诊为BE的患者120例作为研究对象,按照随机分配的原则将其分为碘染色组﹑i-scan成像组及对照组,各40例。... 目的探究i-scan成像技术与碘染色对Barrett食管诊断价值。方法选取2016年1月~2017年7月由于各种上消化道症状至我院行内镜检查而疑诊为BE的患者120例作为研究对象,按照随机分配的原则将其分为碘染色组﹑i-scan成像组及对照组,各40例。三组患者分别采用碘染色﹑i-scan成像和常规内镜随机4象限活检,比较三组患者的病理符合率及BE中肠化﹑不典型增生和早期腺癌的检出率。结果三组患者病理符合率的差异有统计学意义(P<0.05),碘染色组和i-scan成像组的病理符合率均显著高于对照组(P<0.05),但碘染色组和i-scan成像组的病理符合率的比较并无统计学意义(P>0.05);三组患者BE中肠化﹑不典型增生和早期腺癌检出率的比较均无统计学意义(P>0.05)。结论 i-scan成像技术与碘染色同随机4象限活检相比,具有较高的病理符合率,对于BE的诊断价值大,但是对于BE食管中肠化﹑不典型增生和早期腺癌的检出率的提升并没有意义,尚需要更进一步的探索和研究。 展开更多
关键词 i-scan成像技术 碘染色 Barrett食管(BE) 诊断
下载PDF
Tobacco Sorter和Tobacco Scan 6000烟草异物剔除系统的比较 被引量:11
9
作者 唐向阳 张勇 +3 位作者 黄岗 谢红万 关宏 李江有 《烟草科技》 EI CAS 2004年第2期13-16,共4页
对TobaccoSorter和TobaccoScan 60 0 0系列的烟草异物剔除系统进行了对比 ,从系统组成、烟叶单层化及稳定传送装置、图像获取方式及识别算法、异物的剔除方法、照明光源等方面进行了详细的比较和分析 ,由此看出 :随着相关技术的快速发... 对TobaccoSorter和TobaccoScan 60 0 0系列的烟草异物剔除系统进行了对比 ,从系统组成、烟叶单层化及稳定传送装置、图像获取方式及识别算法、异物的剔除方法、照明光源等方面进行了详细的比较和分析 ,由此看出 :随着相关技术的快速发展 ,应用线性CCD摄像机作为检测装置的异物剔除系统将具有越来越明显的优势。 展开更多
关键词 TOBACCO Sorter TOBACCO scan6000系列 烟草异物剔除系统 计算机视觉技术 数字图像处理
下载PDF
飞秒Z—scan法测量有机溶液的双光子吸收截面
10
作者 王明建 李德川 李健 《山东师范大学学报(自然科学版)》 CAS 2009年第1期52-54,共3页
按照单光束Z—scan法,利用飞秒激光脉冲对Rb甲醇溶液进行了测量研究,详细研究了光强大小对实验结果的影响,通过对样品池和溶剂进行Z扫描,排除了样品池和溶剂发生非线性吸收带来的误差,利用薄样品理论对测量数据进行计算处理,所得... 按照单光束Z—scan法,利用飞秒激光脉冲对Rb甲醇溶液进行了测量研究,详细研究了光强大小对实验结果的影响,通过对样品池和溶剂进行Z扫描,排除了样品池和溶剂发生非线性吸收带来的误差,利用薄样品理论对测量数据进行计算处理,所得结果与其他方法测得的结果相吻合,证明了此实验方法对有机溶液的测量和处理方法的合理性和有效性. 展开更多
关键词 单光束Z—scan技术 有机溶液 双光子吸收系数 飞秒激光
下载PDF
Evaluation of the Functional Impression Technique with Various Impression Materials on the Surface Topography of Dental Stone Casts and Their Effect on Retention
11
作者 Manal R. Alammari 《Open Journal of Stomatology》 2018年第7期258-270,共13页
Background: The accuracy of the final prosthesis is affected by the final impression technique and master cast production. The aim of the present study was to evaluate the effect of the functional impression technique... Background: The accuracy of the final prosthesis is affected by the final impression technique and master cast production. The aim of the present study was to evaluate the effect of the functional impression technique with various impression materials on the surface characteristic of dental stone casts and their clinical effect on the retention of complete dentures. Method: Specimens of three impression materials/stone casts were fabricated. The specimens of the impression materials/stone casts were divided into three equal groups (I, II, and III). The impression materials used were as follows: tissue conditioner group (I), zinc oxide (ZEO) (group II) and poly (vinyl siloxane) (PVS) (group III). Cylindrical split aluminium moulds were designed to receive the impression materials and the stone mixture. The surface roughness of the stone cast specimens of the three groups (I, II, and III) was measured with a surface profilometer and analyzed by a scanning electron microscope. A clinical study included five severely resorbed mandibular edentulous alveolar ridges and edentulous maxillary arches. Each subject received three heat-cured acrylic resin dentures, fabricated using the functional impression technique. The three dentures were identical except for the different impression materials used from Groups I, II and III. The retentive force of each denture for each subject was measured. Result: The results of this study revealed that the mean value of surface roughness of the stone cast surface of group I was higher than group II and group III. A statistically significant difference was observed in surface roughness and the retentive dislodging force between the three studied groups. Although using a tissue conditioner as a functional impression material led to a high level of surface roughness and good retention, it could not produce the same smooth surface quality of PVS or ZEO. These data were supported by SEM analysis. The complete dentures for these patients require important oral and denture hygiene care. Conclusion: Complete dentures made using functional impression technique with PVC as a final impression material are more comfortable, retentive and stable. 展开更多
关键词 IMPRESSION techniques IMPRESSION Materials Surface Roughness scanning Electron MICROSCOPE and Retention of Complete DENTURE
下载PDF
Immediate-release Mechanism of Dehydrotrametenolic Acid and Dehydroeburicoic Acid in Poriae Cutis Total Triterpenoids Tablets Based on Liquid-solid Compact Technique
12
作者 Xuesheng YAN Dandan SUN +2 位作者 Yanwei GUO Xingang XU Beibei YU 《Medicinal Plant》 2017年第4期37-39,47,共4页
[Objectives]To study the immediate-release mechanism of dehydrotrametenolic acid and dehydroeburicoic acid in Poriae Cutis total triterpenoids tablets by liquid-solid compacts technique.[Methods] Taking dehydrotramete... [Objectives]To study the immediate-release mechanism of dehydrotrametenolic acid and dehydroeburicoic acid in Poriae Cutis total triterpenoids tablets by liquid-solid compacts technique.[Methods] Taking dehydrotrametenolic acid and dehydroeburicoic acid as indicators,differences in dissolution were compared between liquid-solid compressed tablets and crude drug of total triterpenoids in Poriae Cutis;crude drug,powder of liquid-solid compressed tablets and excipients of liquid-solid compressed tablets were characterized by differential scanning calorimetry( DSC).[Results]Liquid-solid compact technique could significantly improve dissolution rate of dehydrotrametenolic acid and dehydroeburicoic acid. The total dissolution rate of dehydrotrametenolic acid and dehydroeburicoic acid in Poriae Cutis total triterpenoids tablets was 92%,t50( time for 50% total dissolution rate) and t_D( time for 63. 2% total dissolution rate) were 11. 18 min and 22. 71 min; the total dissolution rate of dehydrotrametenolic acid and dehydroeburicoic acid in crude drug of total triterpenoids was 29%,and t50 and t_D were231. 06 min and 359. 23 min. DSC showed that there was no mutual interaction between excipients and total triterpenoids in Poriae Cutis; on the DSC curve for powder of liquid-solid compressed tablets,the absorption peak vanished completely,indicating that the drug exists in the amorphous form in the liquid-solid powder.[Conclusions] Liquid-solid compact technique can increase the dissolution rate of total triterpenoids in Poriae Cutis and allow rapid release of poorly water soluble drugs. 展开更多
关键词 Liquid-solid compact technique Poriae Cutis Total TRITERPENOIDS In VITRO dissolution Differential scanning CALORIMETRY
下载PDF
科宝尿分析系统Combi Scan XS/XL尿液检验分析及性能评价 被引量:1
13
作者 梁敏华 吴英 《现代医药卫生》 2013年第11期1632-1633,共2页
目的对科宝尿分析流水线Combi Scan XS/XL进行性能验证,以确认该设备能够满足使用需求。方法随机选取近年住院患者尿液样本100份,对样本采用科宝尿分析流水线进行检测分析,同时与手工镜检结果进行比较。结果科宝Combi Scan XL干化学分... 目的对科宝尿分析流水线Combi Scan XS/XL进行性能验证,以确认该设备能够满足使用需求。方法随机选取近年住院患者尿液样本100份,对样本采用科宝尿分析流水线进行检测分析,同时与手工镜检结果进行比较。结果科宝Combi Scan XL干化学分析检测结果尿潜血、尿白细胞(酯酶)阳性率分别为33.0%、60.0%,高于手工镜检(29.0%、54.0%),差异有统计学意义(P<0.05);科宝Combi Scan XS沉渣分析检测结果与手工镜检中红细胞、白细胞、上皮细胞阳性率比较,差异无统计学意义(P>0.05),管型比较,差异有统计学意义(P<0.05)。结论按照验证方案规定,对科宝尿分析流水线Combi Scan XS/XL进行性能验证,所得结果与手工镜检结果有较高符合率,同时假阳性率低,能够满足实验室检测需求,可用于医院患者尿样沉渣分析。 展开更多
关键词 尿分析 仪器和设备 实验室技术和方法 科宝尿分析系统 性能评价
下载PDF
Third Order Optical Nonlinearities of C<sub>450</sub>Doped Polymer Thin Film Investigated by the Z-Scan
14
作者 Zainab S. Sadik Dhia H. Al-Amiedy Amal F. Jaffar 《Advances in Materials Physics and Chemistry》 2012年第1期43-49,共7页
In the present work, z-scan technique was used to study the nonlinear properties, represented by nonlinear refractive index and nonlinear absorption coefficient for Coumarin 450 (C450) doped PMMA as a function of conc... In the present work, z-scan technique was used to study the nonlinear properties, represented by nonlinear refractive index and nonlinear absorption coefficient for Coumarin 450 (C450) doped PMMA as a function of concentration for two different solvents. The results show change of the effect from self-focusing to self-defocusing in closed aperture z-can (or change of the effect from two photon absorption to saturable absorption in open aperture z-scan), when the sample dissolved in low viscosity and more polar 展开更多
关键词 Nonlinear OPTICS SOLVENT Effect Z-scan technique
下载PDF
磁共振药代动力灌注扫描在鉴别段样强化肉芽肿性乳腺炎与浸润性导管癌中的价值研究 被引量:1
15
作者 陈艳 吴晓燕 +3 位作者 张敏 黄学菁 成建明 郑李韵 《磁共振成像》 CAS CSCD 北大核心 2024年第3期177-182,共6页
目的 探讨基于压缩感知技术的磁共振药代动力灌注扫描对段样强化的特发性肉芽肿性乳腺炎(idiopathic granulomatous mastitis,IGM)与浸润性导管癌(invasive ductal carcinoma,IDC)的鉴别诊断价值。材料与方法 回顾性分析27例段样强化、... 目的 探讨基于压缩感知技术的磁共振药代动力灌注扫描对段样强化的特发性肉芽肿性乳腺炎(idiopathic granulomatous mastitis,IGM)与浸润性导管癌(invasive ductal carcinoma,IDC)的鉴别诊断价值。材料与方法 回顾性分析27例段样强化、无脓肿型IGM和15例IDC患者的临床及影像资料,均行磁共振药代动力灌注扫描。采用Fisher精确检验、t检验、χ^(2)检验比较两组月经状态、年龄、内部强化方式的差异,采用t检验、Mann Whitney U检验筛选出两组容积转运常数(volume transport constant,K^(trans))、速率常数(rate constant,K_(ep))、血管外细胞外间隙容积分数(extravascular extracellular volume fraction,Ve)值中的差异项,用二元logistic线性回归分析其与IDC的危险系数,并绘制受试者工作特征(receiver operating characteristic,ROC)曲线。结果 两组年龄、月经状态差异均有统计学意义(P=0.001、0.003),而内部强化方式差异无统计学意义(P=0.883)。磁共振药代动力灌注扫描:IGM组K^(trans)值[(0.274±0.163)min^(-1)]低于IDC组[(0.451±0.257) min^(-1)],IGM组K_(ep)值[(0.618±0.245)min^(-1)]低于IDC组[(0.856±0.420) min^(-1)],且两组间K^(trans)及K_(ep)值的差异有统计学意义(P=0.013,0.012)。两组Ve值为IGM组(0.531±0.320)min^(-1)、IDC组(0.629±0.323)min^(-1),差异无统计学意义(P=0.182)。二元logistic线性回归:K^(trans)值的优势比(odds ratios,OR)=2.243[95%置信区间(confidence interval,CI):0.652~6.294](P=0.021),绘制ROC曲线显示,约登指数、敏感度、特异度分别为0.585、73.3%、85.2%,曲线下面积(area under the curve,AUC)=0.778 (95%CI:0.623~0.891)(P=0.001)。结论 基于压缩感知技术的磁共振药代动力灌注扫描所得K^(trans)值对以段样强化为表现的IGM、IDC有鉴别诊断价值。 展开更多
关键词 特发性肉芽肿性乳腺炎 浸润性导管癌 磁共振药代动力灌注扫描 压缩感知 磁共振成像
下载PDF
数字化印模技术应用于口腔种植修复的精度分析 被引量:2
16
作者 唐天弘 朱陈元 翁维民 《口腔颌面修复学杂志》 2024年第2期97-102,共6页
目的:通过口内扫描杆获取的数字化印模与传统硅橡胶印模在种植修复中精度的差异,为临床提供更加准确可靠的种植印模方式。方法:本研究根据排纳标准将20位受试者的32颗种植体纳入研究。将传统硅橡胶印模法和口内扫描数字化印模法确定的... 目的:通过口内扫描杆获取的数字化印模与传统硅橡胶印模在种植修复中精度的差异,为临床提供更加准确可靠的种植印模方式。方法:本研究根据排纳标准将20位受试者的32颗种植体纳入研究。将传统硅橡胶印模法和口内扫描数字化印模法确定的种植体位置与CBCT相比较。测量参数为种植体植入点、根尖点和角度偏差。测量结果由SPSS 21.0进行统计学分析。结果:传统方式测量的种植体植入点偏差为(0.731±0.296)mm,根尖点为(0.982±0.310)mm;数字化印模方式测量的种植体植入点偏差为(0.755±0.274)mm,根尖点为(0.921±0.390)mm。两种方式测得的种植体植入点和根尖点的位置偏差无统计学意义(P>0.05)。数字化印模方式测定的种植体角度偏差(1.172±0.262)°显著优于传统印模方法(2.805±0.908)°(P<0.05)。结论:传统硅橡胶印模法和口内扫描数字化印模法的精度在种植体植入点、根尖点上无差异,在角度上口内扫描数字化印模法精度优于传统硅橡胶印模法。在短跨度牙列的种植印模中,口内扫描数字化有良好的应用前景。 展开更多
关键词 印模精度 数字化印模技术 口内扫描杆
下载PDF
一种旋转移相式高功率微波反射阵列天线
17
作者 许亮 张强 +4 位作者 袁成卫 刘金亮 孙云飞 龚鸿州 刘东琪 《强激光与粒子束》 CAS CSCD 北大核心 2024年第1期5-11,共7页
利用旋转移相技术的几何相位调控方法,提出一种基于传输相位差概念的波束扫描高功率微波反射阵列天线。电磁仿真结果表明,所设计的三叉戟形反射阵列天线单元工作于9.5~10.5 GHz,在0~40°入射角度下具有360°范围内的线性相位调... 利用旋转移相技术的几何相位调控方法,提出一种基于传输相位差概念的波束扫描高功率微波反射阵列天线。电磁仿真结果表明,所设计的三叉戟形反射阵列天线单元工作于9.5~10.5 GHz,在0~40°入射角度下具有360°范围内的线性相位调控能力,真空条件下的功率容量达到1.11 GW。采用该单元设计了半径为200 mm的圆形口径反射阵列天线,并使用全波仿真软件进行验证,利用口径相位分布的可重构特性,所设计的反射阵列天线可以实现±40°范围内的波束扫描。在10 GHz时,波束扫描过程中的增益下降小于1.7 dB,最大增益达到31.1 dBi,对应口径效率为73.42%,最低口径效率超过50%,副瓣电平和轴比始终低于-18.7 dB和1.6 dB。 展开更多
关键词 旋转移相技术 波束扫描 反射阵列天线 高功率微波 功率容量
下载PDF
Study on Estimation Method of Rock Mass Discontinuity Shear Strength Based on Three-Dimensional Laser Scanning and Image Technique 被引量:22
18
作者 唐辉明 葛云峰 +3 位作者 王亮清 苑谊 黄磊 孙淼军 《Journal of Earth Science》 SCIE CAS CSCD 2012年第6期908-913,共6页
The estimation of shear strength of rock mass discontinuity is always a focal, but difficult, problem in the field of geotechnical engineering. Considering the disadvantages and limitation of exist- ing estimation met... The estimation of shear strength of rock mass discontinuity is always a focal, but difficult, problem in the field of geotechnical engineering. Considering the disadvantages and limitation of exist- ing estimation methods, a new approach based on the shadow area percentage (SAP) that can be used to quantify surface roughness is proposed in this article. Firstly, by the help of laser scanning technique, the three-dimensional model of the surface of rock discontinuity was established. Secondly, a light source was simulated, and there would be some shadows produced on the model surface. Thirdly, to obtain the value of SAP of each specimen, the shadow detection technique was introduced for use. Fourthly, compared with the result from direct shear testing and based on statistics, an empirical for- mula was found among SAP, normal stress, and shear strength. Data of Yujian (~ River were used as an example, and the following conclusions have been made. (1) In the case of equal normal stress, the peak shear stress is positively proportional to the SAP. (2) The formula for estimating was derived, and the predictions of peak-shear strength made with this equation well agreed with the experimental re- suits obtained in laboratory tests. 展开更多
关键词 rock mechanics rock mass discontinuity shear strength estimation method three-dimensional laser scanning technique image recognition technique.
原文传递
高强低合金钢焊接接头在海水中的初期腐蚀行为
19
作者 刘雪辉 张慧霞 +2 位作者 隋永强 仝宏韬 李相波 《腐蚀与防护》 CAS CSCD 北大核心 2024年第11期49-55,共7页
通过电化学方法和表面分析技术,研究了高强低合金钢焊接接头在海水中的初期腐蚀行为。结果表明:浸泡前母材区的初始电位较低,腐蚀倾向最大,浸泡后母材区电位波动最大;该焊接接头在初期腐蚀呈现阳极溶解速率由高向低转变的特征,其中母材... 通过电化学方法和表面分析技术,研究了高强低合金钢焊接接头在海水中的初期腐蚀行为。结果表明:浸泡前母材区的初始电位较低,腐蚀倾向最大,浸泡后母材区电位波动最大;该焊接接头在初期腐蚀呈现阳极溶解速率由高向低转变的特征,其中母材区阳极溶解电流密度最大;焊接接头在海水中的初期腐蚀以全面腐蚀和点蚀两种形式发展,腐蚀产物主要成分为α-Fe_(2)O_(3),α-FeOOH和γ-FeOOH。在海水中浸泡初期,焊接接头各区域耐蚀性从低到高排序为母材区、热影响区、焊缝区。 展开更多
关键词 高强低合金钢 焊接接头 初期腐蚀 扫描开尔文探针(SKP) 扫描振动电极技术(SVET)
下载PDF
Processing technique of target capsule's micro inflation hole with a scanning probe 被引量:7
20
作者 SUN Tao, YAN Yongda, GAO Dangzhong, TANG Yongjian, FU Yibei & DONG ShenPrecision Engineering Research Institute, Harbin Institute of Technology, Harbin 150001, China Research Centre of Laser Fusion, Chinese Academy of Engineering Plysics, Mianyang 621900, China Institute of Nuclear Physics and Chemistry, Chinese Academy of Engineering Physics, Mianyang 621900, China 《Science China(Technological Sciences)》 SCIE EI CAS 2004年第1期77-84,共8页
To resolve inflation of inertial confinement fusion (ICF) target and encapsulation of micro inflation hole with adhesive, a scanning probe microscope (SPM) diamond microprobe was used as the cutting tool with SPM in c... To resolve inflation of inertial confinement fusion (ICF) target and encapsulation of micro inflation hole with adhesive, a scanning probe microscope (SPM) diamond microprobe was used as the cutting tool with SPM in contact mode. Some parameters influencing the quality of micro inflation hole, such as the scanning direction of the diamond tip, the scanning rate and the contact force are discussed. Accurate taper hole was achieved whose climension and precision could meet the requirements of inflation and encapsulation technique of micro hole. The experimental results show that using SPM diamond microprobe as the cutting tool and with special processing technique, the precision machining of target capsule's taper inflation hole can be realized. A novel operative technology for filling high Z gas to target is provided. 展开更多
关键词 target capsule scanning probe microscope (SPM) diamond microprobe PROCESSING technique BRITTLE material.
原文传递
上一页 1 2 42 下一页 到第
使用帮助 返回顶部