期刊文献+
共找到194篇文章
< 1 2 10 >
每页显示 20 50 100
Histopathological and Ultrasound Correlation in Women Presenting with Breast Lumps in Yaoundé, Cameroon
1
作者 Yann Chris Mannel Eng Ambroise Merci Seme Engoumou +3 位作者 Armel Philippe Awana Sandrine Prisca Ndongo Onembele Junie Annick Metogo Ntsama Odile Fernande Zeh 《Open Journal of Radiology》 2023年第4期218-231,共14页
Context: Breast cancer is very deadly among women with higher rates in the developing world. Imaging tools such as ultrasound, can be used to differentiate between the types of breast lumps. This study aimed to determ... Context: Breast cancer is very deadly among women with higher rates in the developing world. Imaging tools such as ultrasound, can be used to differentiate between the types of breast lumps. This study aimed to determine the value of ultrasound as a first-line examination in the diagnosis of breast masses. Methods: This was a retrospective cross-sectional study of women presenting with breast lumps from November 2022 to June 2023 at the Yaounde General Hospital, which lasted seven months, from November 2022 to June 2023. The sampling was exhaustive and consecutive. Association between variables was studied using the x<sup>2</sup> test and concordance between ultrasound and histopathological findings was assessed using the Kappa correlation coefficient. Results: 234 women were included in the study. Their mean age was 46.3 ± 11.4 years. Overall, 15 (6.4%) lumps were benign while 219 (93.6%) were malignant. Triple negative (5.6%) was the most recurrent genomic classification. The correlation between the ultrasound and histopathological findings was significant, with an observed concordance rate at 85.1%, kappa = 0.322 and a p-value Conclusion: The performance of ultrasound in differentiating benign and malignant lesion was high. However, the discordant cases highlight the need for a diagnosis system which blends histopathological and radiological findings for an improved management of patients with breast lumps. 展开更多
关键词 ULTRASOUND Histopathological Diagnosis Breast lumps Yaoundé
下载PDF
Collisions Between Lumps/Rogue Waves and Solitons for A(3+1)-Dimensional Generalized Variable-Coefficient Shallow Water Wave Equation
2
作者 WU Xiao-yu DU Zhong 《China Ocean Engineering》 SCIE EI CSCD 2022年第5期808-813,共6页
In this paper,we investigate a(3+1)-dimensional generalized variable-coefficient shallow water wave equation,which can be used to describe the flow below a pressure surface in oceanography and atmospheric science.Empl... In this paper,we investigate a(3+1)-dimensional generalized variable-coefficient shallow water wave equation,which can be used to describe the flow below a pressure surface in oceanography and atmospheric science.Employing the Kadomtsev−Petviashvili hierarchy reduction,we obtain the semi-rational solutions which describe the lumps and rogue waves interacting with the kink solitons.We find that the lump appears from one kink soliton and fuses into the other on the x−y and x−t planes.However,on the x−z plane,the localized waves in the middle of the parallel kink solitons are in two forms:lumps and line rogue waves.The effects of the variable coefficients on the two forms are discussed.The dispersion coefficient influences the speed of solitons,while the background coefficient influences the background’s height. 展开更多
关键词 variable-coefficient shallow water wave equation lumps linear rogue waves Kadomtsev-Petviashvili hierarchy reduction
下载PDF
Analysis of High-Frequency Ultrasound in the differential Diagnosis of Lumps in Foot and Hand
3
作者 Huitong Yan Heying Li +1 位作者 Jianmei Han Yingbo Tang 《Proceedings of Anticancer Research》 2020年第4期27-31,共5页
Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in ha... Objective:To investigate the ultrasonogram characteristics of common lumps in hand and foot,pursuing for greater understanding of hand and foot lumps.Methods:65 cases of ultrasonographic characteristics of lumps in hand and foot were retrospectively analyzed,including the location,size,shape,boundary,internal echo and posterior echo,surrounding relationship and blood flow.Results:Among 65 cases,there were 26 cases of tendon sheath cyst,16 cases of tenosynovitis giant cell tumor,10 cases of hemangioma,4 cases of tendon sheath fibroma,3 cases of epidermoid cyst,2 cases of Schwannoma,2 cases of fibrolipoma,1 case of angiolipoma and 1 case of neurofibroma.The preoperative and postoperative pathological diagnoses of 45 cases,accounting for 69.23%,were consistent,3 cases(4.62%)were misdiagnosed,which included that 2 cases of tenosynovitis giant cell tumor were misdiagnosed as tendon sheath cyst,1 case of neurofibroma as epidermoid cyst,and the preoperative diagnosis of the rest 17 cases(26.15%)were indefinite.Conclusion:The high-frequency ultrasound can diagnose properties of lumps in foot and hand well,providing diagnosis basis for further treatment in clinic. 展开更多
关键词 High-frequency ultrasound lumps Hand and foot Publication
下载PDF
Antidiastole Value of Three-dimensional Ultrasonography and Power Doppler between Uterine Parenchyma Lumps and Endometrial Cancer:A Retrospective Study 被引量:11
4
作者 Yan ZHANG Jing CHEN +1 位作者 Zeng ZHEN Xiao-yan XU 《Current Medical Science》 SCIE CAS 2019年第5期816-819,共4页
Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensi... Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensional(3D)power Doppler ultrasonography angiography(PDA)between endometrial cancer and uterine parenchyma lumps.The data of the blood flow indices in 3D-PDA including the vascularization index(VI),flow index(FI),and vascularization flow index(VFI)in 40 patients with endometrial cancer and 41 patients with uterine parenchyma lumps(endometrial polyps and submucosal myomas)were retrospectively analysed and compared utilizing Virtual Organ Computer-aided AnaLysis(VOCAL)software.The results showed that all the blood flow parameters(VI,FI,VFI)were significantly higher in women with endometrial cancer than in those with uterine parenchyma lumps(P<0.001).The area under the curve of ROC of VI,FI,and VFI was 0.98,0.84,and 0.97,respectively.Thus,the best predictor of endometrial carcinoma was VI with a sensitivity of 97.0% and a specificity of 91.0%.The optimal cutoff value of VI was 4.06%.Our data demonstrated that all of the blood flow signal parameters(including VI,FI,and VFI)in 3D power Doppler ultrasonography had significant antidiastole values between endometrial cancer and uterine parenchyma lumps to assist clinicians in properly diagnosing patients. 展开更多
关键词 power DOPPLER three-dimensional ultrasound UTERINE PARENCHYMA lump ENDOMETRIAL CARCINOMA BLOOD flow signal parameter
下载PDF
Repeated lumps and infections: A case report on breast augmentation complications 被引量:2
5
作者 Ming-Xuan Zhang Shi-Yan Li +3 位作者 Li-Long Xu Bo-Wen Zhao Xiao-Yan Cai Guang-Lan Wang 《World Journal of Clinical Cases》 SCIE 2019年第20期3322-3328,共7页
BACKGROUND Polyacrylamide hydrogel(PAAG)injections were once common in breast augmentation and have been prohibited for augmentation mammaplasty in China since a large number of patients who underwent breast augmentat... BACKGROUND Polyacrylamide hydrogel(PAAG)injections were once common in breast augmentation and have been prohibited for augmentation mammaplasty in China since a large number of patients who underwent breast augmentation with PAAG injections have continued to seek medical advice as a result of related complications.Among all these complications,distant migration is relatively rare.CASE SUMMARY A 49-year-old female presented at the hospital with a one-year history of a vulvar lump.The sonography of the lump showed several subcutaneous fluid-filled regions from the left vulva to the pubic symphysis,which suggested possible fat liquefaction.An enhanced magnetic resonance imaging(MRI)revealed a cystic area,which was considered a benign lesion.Intraoperative observations showed that the mass did not have an obvious capsule,the subcutaneous tissue presented as a cavity,and some yellow material came out of this cavity.A culture of the drainage did not show bacterial contamination.Histopathology revealed a foreign body granuloma.After resection and closed drainage,lumps were successively observed in the left lower abdomen and the bilateral hypochondriac region with infections.Sonography found that the hypoechoic areas in the bilateral hypochondriac region seemed continuous with deep in the breasts.The patient reported that she had undergone surgery with PAAG injections 20 years ago after she was repeatedly asked about her past history.Finally,a diagnosis of distant migration of PAAG was made.CONCLUSION PAAG gel can migrate after long periods of time.A diagnosis should not be limited to the area where the symptom develops. 展开更多
关键词 BREAST augmentation DISTANT MIGRATION Repeated lump Repeated INFECTION Case report
下载PDF
General M-lumps, T-breathers, and hybrid solutions to (2+1)-dimensional generalized KDKK equation
6
作者 袁培森 齐家馨 +1 位作者 李子良 安红利 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第4期173-183,共11页
A special transformation is introduced and thereby leads to the N-soliton solution of the(2+1)-dimensional generalized Konopelchenko-Dubrovsky-Kaup-Kupershmidt(KDKK) equation.Then,by employing the long wave limit and ... A special transformation is introduced and thereby leads to the N-soliton solution of the(2+1)-dimensional generalized Konopelchenko-Dubrovsky-Kaup-Kupershmidt(KDKK) equation.Then,by employing the long wave limit and imposing complex conjugate constraints to the related solitons,various localized interaction solutions are constructed,including the general M-lumps,T-breathers,and hybrid wave solutions.Dynamical behaviors of these solutions are investigated analytically and graphically.The solutions obtained are very helpful in studying the interaction phenomena of nonlinear localized waves.Therefore,we hope these results can provide some theoretical guidance to the experts in oceanography,atmospheric science,and weather forecasting. 展开更多
关键词 KDKK equation Hirota bilinear method high-order lump solution T-breather solution hybrid solution
下载PDF
Localized wave solutions and interactions of the (2+1)-dimensional Hirota-Satsuma-Ito equation
7
作者 巩乾坤 王惠 王云虎 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期409-416,共8页
This paper studies the(2+1)-dimensional Hirota-Satsuma-Ito equation.Based on an associated Hirota bilinear form,lump-type solution,two types of interaction solutions,and breather wave solution of the(2+1)-dimensional ... This paper studies the(2+1)-dimensional Hirota-Satsuma-Ito equation.Based on an associated Hirota bilinear form,lump-type solution,two types of interaction solutions,and breather wave solution of the(2+1)-dimensional Hirota-Satsuma-Ito equation are obtained,which are all related to the seed solution of the equation.It is interesting that the rogue wave is aroused by the interaction between one-lump soliton and a pair of resonance stripe solitons,and the fusion and fission phenomena are also found in the interaction between lump solitons and one-stripe soliton.Furthermore,the breather wave solution is also obtained by reducing the two-soliton solutions.The trajectory and period of the one-order breather wave are analyzed.The corresponding dynamical characteristics are demonstrated by the graphs. 展开更多
关键词 lump solution rogue wave solution breather wave solution (2+1)-dimensional Hirota-Satsuma-Ito equation
下载PDF
High-Order Soliton Solutions and Hybrid Behavior for the (2 + 1)-Dimensional Konopelchenko-Dubrovsky Equations
8
作者 Xingying Li Yin Ji 《Journal of Applied Mathematics and Physics》 2024年第7期2452-2466,共15页
In this paper, the evolutionary behavior of N-solitons for a (2 + 1)-dimensional Konopelchenko-Dubrovsky equations is studied by using the Hirota bilinear method and the long wave limit method. Based on the N-soliton ... In this paper, the evolutionary behavior of N-solitons for a (2 + 1)-dimensional Konopelchenko-Dubrovsky equations is studied by using the Hirota bilinear method and the long wave limit method. Based on the N-soliton solution, we first study the evolution from N-soliton to T-order (T=1,2) breather wave solutions via the paired-complexification of parameters, and then we get the N-order rational solutions, M-order (M=1,2) lump solutions, and the hybrid behavior between a variety of different types of solitons combined with the parameter limit technique and the paired-complexification of parameters. Meanwhile, we also provide a large number of three-dimensional figures in order to better show the degeneration of the N-soliton and the interaction behavior between different N-solitons. 展开更多
关键词 Konopelchenko-Dubrovsky Equations Hirota Bilinear Method M-Order Lump Solutions High-Order Hybrid Solutions Interaction Behavior
下载PDF
Preliminary study on CT perfusion imaging in guiding biopsy of pulmonary lumps 被引量:7
9
作者 KANG Li-qing SONG Zhao-wei +4 位作者 LI Zhong-xin YU Shu-jing LIU Feng-hai CHEN Yue-feng XING Rong-ge 《Chinese Medical Journal》 SCIE CAS CSCD 2009年第7期807-812,共6页
Background CT perfusion imaging (CTP) has been proved to be a powerful functional imaging technique. This study aimed to evaluate the value of CTP in guiding biopsy of pulmonary lumps. Methods A total of 147 patient... Background CT perfusion imaging (CTP) has been proved to be a powerful functional imaging technique. This study aimed to evaluate the value of CTP in guiding biopsy of pulmonary lumps. Methods A total of 147 patients with pulmonary lumps who had CT guided biopsies were enrolled in this study from February 2005 to June 2007. The patients were assigned to 3 groups: 33 cases guided by CTP as group 1, 45 cases guided by contrast-enhanced scan of CT as group Ⅱ, and 69 cases guided by plain scan of CT as group Ⅲ. Each group was subdivided into central and peripheral types according to the location of the lumps. The achievement ratio of biopsy, the accuracy in grouping, and grading of lung cancer, and the incidence of complication were compared. Results The total achievement ratios of biopsy from group Ⅰ to Ⅲ were 100% (33/33), 91% (41/45), and 80% (55/69) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ (P 〈0.05). For the central type, they were 100% (18/18), 88% (15/17), and 79% (11/14) respectively, and the difference was also statistically significant between group Ⅰand Ⅲ (P 〈0.05). For the peripheral type, they were 100% (15/15), 93% (26/28), and 80% (44/55) respectivelies, and the difference was not statistically significant among the three groups. The total accuracies in grouping and grading of lung cancer from group Ⅰ to Ⅲ were 100% (27/27), 91% (31/34), and 72% (33/46) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ and between group Ⅱ and Ⅲ (P 〈0.05). For the central type, they were 100% (16/16), 94% (16/17), and 70% (8/12) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ (P〈0.05). For the peripheral type, they were 100% (11/11), 88% (15/17), and 72% (26/36) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ (P 〈0.05). The total incidence of complication from group Ⅰ to Ⅲ were 15% (5/33), 27% (12/45), and 43% (30/69) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ (P 〈0.01). For the central type, they were 11% (2/18), 24% (4/17), and 57% (8/14) respectively, and the difference was statistically significant between group Ⅰ and Ⅲ (P 〈0.01). For the peripheral type, they were 20% (3/15), 29% (8/28), and 40% (22/55) respectively, and no statistically significant difference was found among the three groups. Conclusions CTP guided biopsy of pulmonary lumps using multi-detector row CT has the potential to improve the accuracy of histopathological diagnosis with a lower risk and higher achievement ratio. More research and technical improvements are needed before it is widelv used. 展开更多
关键词 pulmonary lump tomography X-ray computerized perfusion imaging BIOPSY
原文传递
广义(3+1)维KP方程的精确有理解
10
作者 胡英武 《金华职业技术学院学报》 2023年第6期70-73,共4页
利用Hirota方法及Maple,得到了一类带9个二阶导数项的(3+1)维KP方程的精确有理解。在一定条件下,方程有lump型解,解中有八个自由参数,在特定参数下,通过定量与作图分析给出了解的数值模拟。
关键词 广义(3+1)维KP方程 HIROTA方法 有理解 lump型解
下载PDF
Dynamics of lump chains for the BKP equation describing propagation of nonlinear waves 被引量:1
11
作者 赵忠龙 和玲超 Abdul-Majid Wazwaz 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期226-236,共11页
A large member of lump chain solutions of the(2+1)-dimensional Bogoyavlenskii-Kadomtsev-Petviashvili(BKP)equation are constructed by means of theτ-function in the form of Grammian.The lump chains are formed by period... A large member of lump chain solutions of the(2+1)-dimensional Bogoyavlenskii-Kadomtsev-Petviashvili(BKP)equation are constructed by means of theτ-function in the form of Grammian.The lump chains are formed by periodic arrangement of individual lumps and travel with distinct group and velocities.An analytical method related dominant regions of polygon is developed to analyze the interaction dynamics of the multiple lump chains.The degenerate structures of parallel,superimposed,and molecular lump chains are presented.The interaction solutions between lump chains and kink-solitons are investigated,where the kink-solitons lie on the boundaries of dominant region determined by the constant term in theτ-function.Furthermore,the hybrid solutions consisting of lump chains and individual lumps controlled by the parameter with high rank and depth are investigated.The analytical method presented in this paper can be further extended to other integrable systems to explore complex wave structures. 展开更多
关键词 lump chains interaction solutions BKP equation
下载PDF
广义(3+1)维KdV方程的lump解、相互作用解和呼吸子解 被引量:1
12
作者 于明惠 王云虎 《应用数学和力学》 CSCD 北大核心 2023年第8期1007-1016,共10页
基于广义(3+1)维KdV方程的双线性形式,得到了方程的lump解、相互作用解及呼吸子解.证明了lump解在空间各个方向上都是有理局域的,并在lump波与线孤子的相互作用过程中观察到了“聚变”和“裂变”现象,最后得到了方程的呼吸子解.
关键词 广义(3+1)维KdV方程 lump解 相互作用解 呼吸子解
下载PDF
From breather solutions to lump solutions:A construction method for the Zakharov equation
13
作者 袁丰 Behzad Ghanbari +1 位作者 张永帅 Abdul Majid Wazwaz 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第12期162-169,共8页
Periodic solutions of the Zakharov equation are investigated.By performing the limit operationλ_(2l-1)→λ_(1)on the eigenvalues of the Lax pair obtained from the n-fold Darboux transformation,an order-n breather-pos... Periodic solutions of the Zakharov equation are investigated.By performing the limit operationλ_(2l-1)→λ_(1)on the eigenvalues of the Lax pair obtained from the n-fold Darboux transformation,an order-n breather-positon solution is first obtained from a plane wave seed.It is then proven that an order-n lump solution can be further constructed by taking the limitλ_(1)→λ_(0)on the breather-positon solution,because the unique eigenvalueλ_(0)associated with the Lax pair eigenfunctionΨ(λ_(0))=0 corresponds to the limit of the infinite-periodic solutions.A convenient procedure of generating higher-order lump solutions of the Zakharov equation is also investigated based on the idea of the degeneration of double eigenvalues in multi-breather solutions. 展开更多
关键词 Zakharov equation breather solution b-positon solution lump solution
下载PDF
Different wave patterns for two-coupled Maccari's system with complex structure via truncated Painlevéapproach
14
作者 马红彩 戚心茹 邓爱平 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第12期293-298,共6页
We focused on the two-coupled Maccari's system.With the help of truncated Painlevéapproach(TPA),we express local solution in the form of arbitrary functions.From the solution obtained,using its appropriate ar... We focused on the two-coupled Maccari's system.With the help of truncated Painlevéapproach(TPA),we express local solution in the form of arbitrary functions.From the solution obtained,using its appropriate arbitrary functions,we have generated the rogue wave pattern solutions,rogue wave solutions,and lump solutions.In addition,by controlling the values of the parameters in the solutions,we show the dynamic behaviors of the rogue wave pattern solutions,rogue wave solutions,and lump solutions with the aid of Maple tool.The results of this study will contribute to the understanding of nonlinear wave dynamics in higher dimensional Maccari's systems. 展开更多
关键词 two-coupled Maccari's system rogue wave lump wave truncated Painlevéapproach
下载PDF
Rheological and Morphological Characterization of Modified Bitumen with Cup Lump Rubber
15
作者 Mohammed Albuaymi Suleiman Abdulrahman +2 位作者 Fayez Alanazi Hani Alanazi Musa Adamu 《Journal of Renewable Materials》 SCIE EI 2023年第5期2433-2451,共19页
Pure bitumen is not suitable for heavy traffic loads;hence modifiers are used to improve the bitumen performance.Recently,cup lump rubber(CLR)has become a preferred modifier due to its outstanding performance and less... Pure bitumen is not suitable for heavy traffic loads;hence modifiers are used to improve the bitumen performance.Recently,cup lump rubber(CLR)has become a preferred modifier due to its outstanding performance and less cost.However,little is known about the interactions between CLR and bitumen.Thus,this study investigates the behavior of bitumen with CLR.Four percentages of CLR(2.5%,5.0%,7.5%,and 10.0%by weight of bitumen)were used to modify conventional 60/70 penetration grade bitumen.The modified bitumen was evaluated through different laboratory testing such as dynamic shear rheometer,rotational viscosity,softening point,bending beam rheometer,ductility,and elastic recovery.The testing results show that the addition of CLR increased the bitumen’s rutting resistance by 3 PG grades at high temperatures.At low pavement temperatures,the cup lump rubber modified bitumen(CMB)can withstand up to−34℃.Fourier Transform Infrared(FTIR)analysis shows that the Aromaticity index at 1600 cm^(−1) rose as the CLR percentage increased,indicating the formation of a binder with a compact structure.This is expected to improve the elasticity of bitumen throughπ-πinteractions.Atomic Force Microscopy(AFM)results showed the Catana phase increased in size and quantity at 5.0%and 7.5%CLR content.While contact angle measurement revealed that the binders are hydrophobic and tend to repel the dropped water on the bitumen surface. 展开更多
关键词 Cup lump rubber polymer modified bitumen HYDROPHOBICITY natural rubber
下载PDF
Resonant interactions among two-dimensional nonlinear localized waves and lump molecules for the(2+1)-dimensional elliptic Toda equation
16
作者 庞福忠 葛根哈斯 赵雪梅 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期200-217,共18页
The(2+1)-dimensional elliptic Toda equation is a high-dimensional generalization of the Toda lattice and a semidiscrete Kadomtsev–Petviashvili I equation.This paper focuses on investigating the resonant interactions ... The(2+1)-dimensional elliptic Toda equation is a high-dimensional generalization of the Toda lattice and a semidiscrete Kadomtsev–Petviashvili I equation.This paper focuses on investigating the resonant interactions between two breathers,a breather/lump and line solitons as well as lump molecules for the(2+1)-dimensional elliptic Toda equation.Based on the N-soliton solution,we obtain the hybrid solutions consisting of line solitons,breathers and lumps.Through the asymptotic analysis of these hybrid solutions,we derive the phase shifts of the breather,lump and line solitons before and after the interaction between a breather/lump and line solitons.By making the phase shifts infinite,we obtain the resonant solution of two breathers and the resonant solutions of a breather/lump and line solitons.Through the asymptotic analysis of these resonant solutions,we demonstrate that the resonant interactions exhibit the fusion,fission,time-localized breather and rogue lump phenomena.Utilizing the velocity resonance method,we obtain lump–soliton,lump–breather,lump–soliton–breather and lump–breather–breather molecules.The above works have not been reported in the(2+1)-dimensional discrete nonlinear wave equations. 展开更多
关键词 (2+1)-dimensional elliptic Toda equation resonant interaction lump molecules
下载PDF
Simulation of anchor chain based on lumped mass method
17
作者 Xiaobin Jiang Jian Gan Shiyang Teng 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2023年第4期311-319,共9页
In order to develop a anchoring operation simulation system and improve safety during anchoring operations,a relatively accurate mathematical model of anchoring operations needs to be established.In this paper,the str... In order to develop a anchoring operation simulation system and improve safety during anchoring operations,a relatively accurate mathematical model of anchoring operations needs to be established.In this paper,the stress condition of anchor chain under environmental and subsea geological conditions is further studied and the stress condition of anchor chain is analyzed based on the previous research.In this paper,a quasi-static model based on catenary method is used as the basis of dynamic analysis,and the dynamic model of anchor chain is established based on the concentrated mass method,which fully considers the influence of anchor chain weight,hydrodynamic force,ocean current and interaction with the seabed.The fourth-order Runge Kutta method was used to solve the model numerically,and a calculation procedure was developed.The accuracy of the model was verified by comparing the calculated results with the experimental results,indicating that the constructed anchor chain dynamics model has a high accuracy. 展开更多
关键词 Lump mass method Anchor chain Dynamic analysis
下载PDF
Interaction solutions for the second extended(3+1)-dimensional Jimbo–Miwa equation
18
作者 马红彩 毛雪 邓爱平 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第6期112-121,共10页
Based on the Hirota bilinear method,the second extended(3+1)-dimensional Jimbo–Miwa equation is established.By Maple symbolic calculation,lump and lump-kink soliton solutions are obtained.The interaction solutions be... Based on the Hirota bilinear method,the second extended(3+1)-dimensional Jimbo–Miwa equation is established.By Maple symbolic calculation,lump and lump-kink soliton solutions are obtained.The interaction solutions between the lump and multi-kink soliton,and the interaction between the lump and triangular periodic soliton are derived by combining a multi-exponential function or trigonometric sine and cosine functions with quadratic functions.Furthermore,periodiclump wave solution is derived via the ansatz including hyperbolic and trigonometric functions.Finally,3D plots,2D curves,density plots,and contour plots with particular choices of the suitable parameters are depicted to illustrate the dynamical features of these solutions. 展开更多
关键词 Hirota bilinear method second extended(3+1)-dimensional Jimbo–Miwa equation lump solution interaction solution
下载PDF
Effect of lump ore ratio on the metallurgical properties of blast furnace charge
19
作者 TAN Chenglin MAO Xiaoming XU Wanren 《Baosteel Technical Research》 CAS 2023年第4期28-34,共7页
We conducted a series of experimental studies on the metallurgical properties of N-lump and F-lump ores used in Baosteel’s blast furnace, including thermal cracking, low-temperature reduction pulverization, reducibil... We conducted a series of experimental studies on the metallurgical properties of N-lump and F-lump ores used in Baosteel’s blast furnace, including thermal cracking, low-temperature reduction pulverization, reducibility, and droplet properties.The results show that the thermal burst properties of N-lump ore are better than those of F-lump ore.The low-temperature reduction degradation index(RDI) pulverization of the charge is the best when the ratios of N-lump ore and F-lump ore account for 35% each.The reduction performance of the charge is improved when F-lump and N-lump ores are mixed with sinter.In the softening-melting performance experiment, when the proportion of N-lump ore is 40%,the characteristic area value(S) as the charge permeability index is the smallest.When F-lump ore is mixed with sinter, its droplet performance improves compared with that of single F-lump ore.The proportion of F-lump ore should not exceed 15%. 展开更多
关键词 lump ore ratio metallurgical property experiment softening-melting property the RDI pulverization reduction property
下载PDF
Introduction to Mesh Based Generated Lumped Parameter Models for Electromagnetic Problems using Triangular Elements
20
作者 Haidar Y.Diab Salim Asfirane +2 位作者 Nicolas Bracikowski Frédéric Gillon Yacine Amara 《CES Transactions on Electrical Machines and Systems》 CSCD 2023年第1期21-34,共14页
This paper is an introduction to mesh based generated reluctance network modeling using triangular elements.Many contributions on mesh based generated reluctance networks using rectangular shaped elements have been pu... This paper is an introduction to mesh based generated reluctance network modeling using triangular elements.Many contributions on mesh based generated reluctance networks using rectangular shaped elements have been published,but very few on those generated from a mesh using triangular elements.The use of triangular elements is aimed at extending the application of the approach to any shape of modeled devices.Basic concepts of the approach are presented in the case of electromagnetic devices.The procedure for coding the approach in the case of a flat linear permanent magnet machine is presented.Codes developed under MATLAB environment are also included. 展开更多
关键词 Lumped parameter modeling Finite element method MESH Triangular elements Electromagnetic devices MODELING
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部