BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model ...BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.展开更多
HT7U is a large fusion experimental device. It will be built in the Institute of Plasma Physics of Chinese Academy of Sciences. The mission of HT-7U is to develop the scientific basis for a continuously operating toka...HT7U is a large fusion experimental device. It will be built in the Institute of Plasma Physics of Chinese Academy of Sciences. The mission of HT-7U is to develop the scientific basis for a continuously operating tokama-k fusion reactor. This paper describes only a toroidal field (TF) superconducting magnet system of HT7U. In this paper, design criteria of conductor and stability analysis, coil winding and support structure design of magnet system, mechanical calculation and stress analysis, heat load evaluation are given.展开更多
A 5.8 T cryogen-free superconducting magnet (SCM) system with a warm bore hole of 160 mm in diameter, used for gyrotrons operating in the frequency range from 68 GHz to 140 GHz, is installed on the site of the HL-2A...A 5.8 T cryogen-free superconducting magnet (SCM) system with a warm bore hole of 160 mm in diameter, used for gyrotrons operating in the frequency range from 68 GHz to 140 GHz, is installed on the site of the HL-2A tokamak. The SCM consists of two separate solenoidal magnetic coils connected in series, a 4.2 K Gifford-McMahon (GM) refrigerator, a com- pressor, a coil power supply and two temperature monitors. The performance, test and preliminary experimental results of this SCM system are described in this paper. The magnetic field distribu- tion was measured along the axis, and a dummy tube was used for adjusting the magnet system. Finally, the magnet was used for the operation of a 68 GHz/500 kW gyrotron, which is part of an electron cyclotron resonance heating (ECRH) system. With an additional auxiliary coil and after adjusting tile magnet system, a maximum output power for the ECRH system of up to 400 kW was achieved.展开更多
The mission of Korea Superconducting Tokamak Advanced Research (KSTAR)project is to develop an advanced steady-state superconducting tokamak for establishing a scientificand technological basis for an attractive fusio...The mission of Korea Superconducting Tokamak Advanced Research (KSTAR)project is to develop an advanced steady-state superconducting tokamak for establishing a scientificand technological basis for an attractive fusion reactor. Because one of the KSTAR mission is toachieve a steady-state operation, the use of superconducting coils is an obvious choice for themagnet system. The KSTAR superconducting magnet system consists of 16 Toroidal Field (TF) coils and14 Poloidal Field (PF) coils. Internally-cooled Cable-In-Conduit Conductors (CICC) are put into usein both the TF and PF coil systems. The TF coil system provides a field of 3.5 T at the plasmacenter and the PF coil system is able to provide a flux swing of 17 V-sec. The major achievement inKSTAR magnet-system development includes the development of CICC, the development of a full-size TFmodel coil, the development of a coil system for background magnetic-field generation , theconstruction of a large-scale superconducting magnet and CICC test facility. TF and PF coils are inthe stage of fabrication to pave the way for the scheduled completion of KSTAR by the end of 2006.展开更多
For power plants heliotron-type reactors have attractive advantages, such asno current-disruptions, no current-drive, and wide space between helical coils for the maintenanceof in-vessel components. However, one disad...For power plants heliotron-type reactors have attractive advantages, such asno current-disruptions, no current-drive, and wide space between helical coils for the maintenanceof in-vessel components. However, one disadvantage is that a major radius has to be large enough toobtain large Q-value or to produce sufficient space for blankets. Although the larger radius isconsidered to increase the construction cost, the influence has not been understood clearly, yet.Scale effects on superconducting magnet systems have been estimated under the conditions of aconstant energy confinement time and similar geometrical parameters. Since the necessary magneticfield with a larger radius becomes lower, the increase rate of the weight of the coil support to themajor radius is less than the square root. The necessary major radius will be determined mainly bythe blanket space. The appropriate major radius will be around 13 m for a reactor similar to theLarge Helical Device (LHD).展开更多
Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to t...Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field.展开更多
The modeling and self-excited vibration mechanism in the magnetic levitation-collision interface coupling system are investigated.The effects of the control and interface parameters on the system's stability are a...The modeling and self-excited vibration mechanism in the magnetic levitation-collision interface coupling system are investigated.The effects of the control and interface parameters on the system's stability are analyzed.The frequency range of self-excited vibrations is investigated from the energy point of view.The phenomenon of self-excited vibrations is elaborated with the phase trajectory.The corresponding control strategies are briefly analyzed with respect to the vibration mechanism.The results show that when the levitation objects collide with the mechanical interface,the system's vibration frequency becomes larger with the decrease in the collision gap;when the vibration frequency exceeds the critical frequency,the electromagnetic system continues to provide energy to the system,and the collision interface continuously dissipates energy so that the system enters the self-excited vibration state.展开更多
Magnetic reconnection processes in three-dimensional(3D)complex field configurations have been investigated in different magneto-plasma systems in space,laboratory,and astrophysical systems.Two-dimensional(2D)features...Magnetic reconnection processes in three-dimensional(3D)complex field configurations have been investigated in different magneto-plasma systems in space,laboratory,and astrophysical systems.Two-dimensional(2D)features of magnetic reconnection have been well developed and applied successfully to systems with symmetrical property,such as toroidal fusion plasmas and laboratory experiments with an axial symmetry.But in asymmetric systems,the 3D features are inevitably different from those in the 2D case.Magnetic reconnection structures in multiple celestial body systems,particularly star-planet-Moon systems,bring fresh insights to the understanding of the 3D geometry of reconnection.Thus,we take magnetic reconnection in an ancient solar-lunar terrestrial magneto-plasma system as an example by using its crucial parameters approximately estimated already and also some specific applications in pathways for energy and matter transports among Earth,ancient Moon,and the interplanetary magnetic field(IMF).Then,magnetic reconnection of the ancient lunar-terrestrial magnetospheres with the IMF is investigated numerically in this work.In a 3D simulation for the Earth-Moon-IMF system,topological features of complex magnetic reconnection configurations and dynamical characteristics of magnetic reconnection processes are studied.It is found that a coupled lunar-terrestrial magnetosphere is formed,and under various IMF orientations,multiple X-points emerge at distinct locations,showing three typical magnetic reconnection structures in such a geometry,i.e.,the X-line,the triple current sheets,and the A-B null pairs.The results can conduce to further understanding of reconnection physics in 3D for plasmas in complex magnetic configurations,and also a possible mechanism for energy and matters transport in evolutions of similar astrophysical systems.展开更多
A high-sensitivity magnetic sensing system based on giant magneto-impedance(GMI)effect is designed and fabricated.The system comprises a GMI sensor equipped with a gradient probe and an signal acquisition and processi...A high-sensitivity magnetic sensing system based on giant magneto-impedance(GMI)effect is designed and fabricated.The system comprises a GMI sensor equipped with a gradient probe and an signal acquisition and processing module.A segmented superposition algorithm is used to increase target signal and reduce the random noise.The results show that under unshielded,room temperature conditions,the system achieves successful detection of weak magnetic fields down to 2 pT with a notable sensitivity of 1.84×108V/T(G=1000).By applying 17 overlays,the segmented superposition algorithm increases the power proportion of the target signal at 31 Hz from6.89%to 45.91%,surpassing the power proportion of the 2 Hz low-frequency interference signal.Simultaneously,it reduces the power proportion of the 20 Hz random noise.The segmented superposition process effectively cancels out certain random noise elements,leading to a reduction in their respective power proportions.This high-sensitivity magnetic sensing system features a simple structure,and is easy to operate,making it highly valuable for both practical applications and broader dissemination.展开更多
BACKGROUND The liver imaging reporting and data system(LI-RADS)diagnostic table has 15 cells and is too complex.The diagnostic performance of LI-RADS for hepatocellular carcinoma(HCC)is not satisfactory on gadoxetic a...BACKGROUND The liver imaging reporting and data system(LI-RADS)diagnostic table has 15 cells and is too complex.The diagnostic performance of LI-RADS for hepatocellular carcinoma(HCC)is not satisfactory on gadoxetic acid-enhanced magnetic resonance imaging(EOB-MRI).AIM To evaluate the ability of the simplified LI-RADS(sLI-RADS)to diagnose HCC on EOB-MRI.METHODS A total of 331 patients with 356 hepatic observations were retrospectively analysed.The diagnostic performance of sLI-RADS A-D using a single threshold was evaluated and compared with LI-RADS v2018 to determine the optimal sLIRADS.The algorithms of sLI-RADS A-D are as follows:The single threshold for sLI-RADS A and B was 10 mm,that is,classified observations≥10mm using an algorithm of 10-19 mm observations(sLI-RADS A)and≥20 mm observations(sLI-RADS B)in the diagnosis table of LI-RADS v2018,respectively,while the classification algorithm remained unchanged for observations<10 mm;the single threshold for sLI-RADS C and D was 20 mm,that is,for<20 mm observations,the algorithms for<10 mm observations(sLI-RADS C)and 10-19 mm observations(sLI-RADS D)were used,respectively,while the algorithm remained unchanged for observations≥20 mm.With hepatobiliary phase(HBP)hypointensity as a major feature(MF),the final sLI-RADS(F-sLI-RADS)was formed according to the optimal sLI-RADS,and its diagnostic performance was evaluated.The times needed to classify the observations according to F-sLIRADS and LI-RADS v2018 were compared.RESULTS The optimal sLI-RADS was sLI-RADS D(with a single threshold of 20 mm),because its sensitivity was greater than that of LI-RADS v2018(89.8%vs 87.0%,P=0.031),and its specificity was not lower(89.4%vs 90.1%,P>0.999).With HBP hypointensity as an MF,the sensitivity of F-sLI-RADS was greater than that of LI-RADS v2018(93.0%vs 87.0%,P<0.001)and sLI-RADS D(93.0%vs 89.8%,P=0.016),without a lower specificity(86.5%vs 90.1%,P=0.062;86.5%vs 89.4%,P=0.125).Compared with that of LI-RADS v2018,the time to classify lesions according to FsLI-RADS was shorter(51±21 s vs 73±24 s,P<0.001).CONCLUSION The use of sLI-RADS with HBP hypointensity as an MF may improve the sensitivity of HCC diagnosis and reduce lesion classification time.展开更多
Permanent magnet synchronous motor(PMSM)speed control systems with conventional linear active disturbance rejection control(CLADRC)strategy encounter issues regarding the coupling between dynamic response and disturba...Permanent magnet synchronous motor(PMSM)speed control systems with conventional linear active disturbance rejection control(CLADRC)strategy encounter issues regarding the coupling between dynamic response and disturbance suppression and have poor performance in suppressing complex nonlinear disturbances.In order to address these issues,this paper proposes an improved two-degree-of-freedom LADRC(TDOF-LADRC)strategy,which can enhance the disturbance rejection performance of the system while decoupling entirely the system's dynamic and anti-disturbance performance to boost the system robustness and simplify controller parameter tuning.PMSM models that consider total disturbances are developed to design the TDOF-LADRC speed controller accurately.Moreover,to evaluate the control performance of the TDOF-LADRC strategy,its stability is proven,and the influence of each controller parameter on the system control performance is analyzed.Based on it,a comparison is made between the disturbance observation ability and anti-disturbance performance of TDOF-LADRC and CLADRC to prove the superiority of TDOF-LADRC in rejecting disturbances.Finally,experiments are performed on a 750 W PMSM experimental platform,and the results demonstrate that the proposed TDOF-LADRC exhibits the properties of two degrees of freedom and improves the disturbance rejection performance of the PMSM system.展开更多
BACKGROUND After approval for clinical use in 2017 early investigations of ultra-high-field abdominal magnetic resonance imaging(MRI)have demonstrated the feasibility as well as diagnostic capabilities of liver,kidney...BACKGROUND After approval for clinical use in 2017 early investigations of ultra-high-field abdominal magnetic resonance imaging(MRI)have demonstrated the feasibility as well as diagnostic capabilities of liver,kidney,and prostate MRI at 7-Tesla.However,the elevation of the field strength to 7-Tesla not only brought advantages to abdominal MRI but also presented considerable challenges and drawbacks,primarily stemming from heightened artifacts and limitations in Specific Absorption Rate,etc.Furthermore,evidence in the literature is relatively scarce concerning human studies in comparison to phantom/animal studies which necessitates an investigation into the evidence so far in humans and summarizing all relevant evidence.AIM To offer a comprehensive overview of current literature on clinical abdominal 7T MRI that emphasizes current trends,details relevant challenges,and provides a concise set of potential solutions.METHODS This systematic review adheres to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.A PubMed search,utilizing Medical Subject Headings terms such as"7-Tesla"and organ-specific terms,was conducted for articles published between January 1,1985,and July 25,2023.Eligibility criteria included studies exploring 7T MRI for imaging human abdominal organs,encompassing various study types(in-vivo/ex-vivo,method development,reviews/meta-analyses).Exclusion criteria involved animal studies and those lacking extractable data.Study selection involved initial identification via title/abstract,followed by a full-text review by two researchers,with discrepancies resolved through discussion.Data extraction covered publication details,study design,population,sample size,7T MRI protocol,image characteristics,endpoints,and conclusions.RESULTS The systematic review included a total of 21 studies.The distribution of clinical 7T abdominal imaging studies revealed a predominant focus on the prostate(n=8),followed by the kidney(n=6)and the hepatobiliary system(n=5).Studies on these organs,and in the pancreas,demonstrated clear advantages at 7T.However,small bowel studies showed no significant improvements compared to traditional MRI at 1.5T.The majority of studies evaluated originated from Germany(n=10),followed by the Netherlands(n=5),the United States(n=5),Austria(n=2),the United Kingdom(n=1),and Italy(n=1).CONCLUSION Further increase of abdominal clinical MRI field strength to 7T demonstrated high imaging potential,yet also limitations mainly due to the inhomogeneous radiofrequency(RF)excitation field relative to lower field strengths.Hence,further optimization of dedicated RF coil elements and pulse sequences are expected to better optimize clinical imaging at high magnetic field strength.展开更多
Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanism...Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanisms underlying strabismic amblyopia and anisometropic amblyopia may be different.Therefore,we performed a systematic review of magnetic resonance imaging studies investigating brain alterations in patients with these two subtypes of amblyopia;this study is registered with PROSPERO(registration ID:CRD42022349191).We searched three online databases(PubMed,EMBASE,and Web of Science) from inception to April 1,2022;39 studies with 633 patients(324patients with anisometropic amblyo pia and 309 patients with strabismic amblyopia) and 580 healthy controls met the inclusion criteria(e.g.,case-control designed,pee r-reviewed articles) and were included in this review.These studies highlighted that both strabismic amblyopia and anisometropic amblyopia patients showed reduced activation and distorted topological cortical activated maps in the striate and extrastriate co rtices during tas k-based functional magnetic resonance imaging with spatial-frequency stimulus and retinotopic representations,respectively;these may have arisen from abnormal visual experiences.Compensations for amblyopia that are reflected in enhanced spontaneous brain function have been reported in the early visual cortices in the resting state,as well as reduced functional connectivity in the dorsal pathway and structural connections in the ventral pathway in both anisometro pic amblyopia and strabismic amblyopia patients.The shared dysfunction of anisometro pic amblyopia and strabismic amblyopia patients,relative to controls,is also chara cterized by reduced spontaneous brain activity in the oculomotor co rtex,mainly involving the frontal and parietal eye fields and the cerebellu m;this may underlie the neural mechanisms of fixation instability and anomalous saccades in amblyopia.With regards to specific alterations of the two forms of amblyo pia,anisometropic amblyo pia patients suffer more microstructural impairments in the precortical pathway than strabismic amblyopia patients,as reflected by diffusion tensor imaging,and more significant dysfunction and structural loss in the ventral pathway.Strabismic amblyopia patients experience more attenuation of activation in the extrastriate co rtex than in the striate cortex when compared to anisometropic amblyopia patients.Finally,brain structural magnetic resonance imaging alterations tend to be lateralized in the adult anisometropic amblyopia patients,and the patterns of brain alterations are more limited in amblyopic adults than in childre n.In conclusion,magnetic resonance imaging studies provide important insights into the brain alterations underlying the pathophysiology of amblyopia and demonstrate common and specific alte rations in anisometropic amblyo pia and strabismic amblyopia patients;these alterations may improve our understanding of the neural mechanisms underlying amblyopia.展开更多
The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magne...The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning.展开更多
In EAST long-pulsed discharge(hundreds of seconds),electric magnetic diagnosis(EMD)is very important,since EMD not only monitors tokamak security status but also provides accurate measurement accuracy for reconstructi...In EAST long-pulsed discharge(hundreds of seconds),electric magnetic diagnosis(EMD)is very important,since EMD not only monitors tokamak security status but also provides accurate measurement accuracy for reconstruction of the plasma boundary.To avoid current measurement drift,a fiber optic current sensor,based on the Faraday effect,is developed and used for poloidal and plasma current feedback control for the first time,relative current measurement accuracy is within 0.5%.To ensure plasma boundary control accuracy,a detailed set of magnetic measurement calibration methods is developed before the plasma discharge.The maximum relative error is less than 1%,the corresponding control accuracy is within 1 cm.To minimize integrator drift error,a long-pulse integrator test is essential,the corresponding drift error needs to be subtracted in plasma control system.Besides,the saddle coil and Mirnov coil not only help to detect MHD issues,but are also utilized for plasma disruption prediction during the long-pulse discharge.展开更多
To determine the cause(s)of perturbations seen in dayside equatorial ground magnetograms,we conducted a systematic survey of simultaneous ground-based and geosynchronous satellite-based observations during the 90-day ...To determine the cause(s)of perturbations seen in dayside equatorial ground magnetograms,we conducted a systematic survey of simultaneous ground-based and geosynchronous satellite-based observations during the 90-day period from December 1,2020 to February 28,2021.We examined Huancayo ground magnetometer observations from 14:00:00 to 20:00:00 UT each day,during which Huancayo passed through local noon.From those data we chose perturbation events selected on the basis of large(>20 nT)event amplitude and classified the selected events as responding primarily to solar wind pressure,or to variations in the north/south component of the interplanetary magnetic field(IMF Bz),or perhaps in part to both.The results show that an equivalent number of events were identified for each model during this 90-day period.Variations in the lagged solar wind dynamic pressure routinely correspond to nearly simultaneous sudden impulses recorded at both geosynchronous orbit and on the ground.Variations in IMF Bz produce erosion signatures at geosynchronous orbit and can correspond to ground events if lag times for reconnection to enhance convection in the magnetosphere are taken into account.展开更多
A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware a...A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware and source-mapping techniques used by the LFM-LMS were introduced;both Monte Carlo simulations and the observation of rocket-triggered lightning examples were employed to examine the location accuracy and detection effectiveness of the LFM-LMS.We estimated that the system’s location accuracy about 100−200 m horizontally and~200 m vertically.A natural intra-cloud lightning flash and a rocket-triggered lightning flash,both with intricate structures and discharging processes,were examined using the three-dimensional mapping results.The progressing path of negative lightning leaders is usually well-defined,and its propagation speed is estimated to be(0.5−1.4)×10^(6)m/s.In summary,the LFM-LMS can reconstruct the three-dimensional morphology of lightning flashes;this technology provides a efficient method for investigating the characteristics of lightning development,as well as the overall electrical strucuture of thunderstorms.展开更多
We construct a mapped bilayer quantum Hall system to realize the proposal that two nearly flatbands have opposite Chern numbers.For the C=±1 case,the two Landau levels of the bilayer experience opposite magnetic ...We construct a mapped bilayer quantum Hall system to realize the proposal that two nearly flatbands have opposite Chern numbers.For the C=±1 case,the two Landau levels of the bilayer experience opposite magnetic fields.We consider a mapped bilayer quantum Hall system at total fillingν_(t)=1/2+1/2where the intralayer interaction is repulsive and the interlayer interaction is attractive.We take exact diagonalization(ED)calculations on a torus to study the phase transition when the separation distance d/l_(B)is driven.The critical point at d_(c)/l_(B)=0.68 is characterized by a collapse of degeneracy and a crossing of energy levels.In the region d/l_(B)<d_(c)/l_(B),the states of each level are highly degenerate.The pair-correlation function indicates electrons with opposite pseudo-spins are strong correlated at r=0.We find an exciton stripe phase composed of bound pairs.The ferromagnetic ground state is destroyed by the strong effective attractive potential.An electron composite-Fermion(eCF)and a hole composite Fermion(hCF)are tightly bound.In the region d/lB>d_(c)/l_(B),a crossover from the d→d_(c)limit to the large d limit is observed.The electron and hole composite Fermion liquids(CFL)are realized by composite Fermions(CF)which attach opposite fluxes,respectively.展开更多
Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise supp...Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise suppression system. On the one hand, we have optimized the magnetic shielding performance of the portable optical clock by reducing its apertures and optimizing its geometry;on the other hand, we have introduced an active magnetic field noise suppression system to further suppress the magnetic field noise experienced by the ions. These efforts reduced the ambient magnetic field noise by about 10000 times, significantly reduced the linewidth of the clock transition spectrum, improved the stability of the portable40Ca+optical clock, and created the conditions for using portable optical clocks in non-laboratory magnetic field environments. This active magnetic field suppression scheme has the advantages of simple installation and wide applicability.展开更多
This paper presents a theoretical and experimental study on controller design for the AMBs in a small-scale flywheel energy storage system,where the main goals are to achieve low energy consumption and improved rotord...This paper presents a theoretical and experimental study on controller design for the AMBs in a small-scale flywheel energy storage system,where the main goals are to achieve low energy consumption and improved rotordynamic stability.A H-infinity optimal control synthesis procedure is defined for the permanent-magnet-biased AMB-rotor system with 4 degrees of freedom.Through the choice of design weighting functions,notch filter characteristics are incorporated within the controller to reduce AMB current components caused by rotor vibration at the synchronous frequency and higher harmonics.Experimental tests are used to validate the controller design methodology and provide comparative results on performance and efficiency.The results show that the H-infinity controller is able to achieve stable rotor levitation and reduce AMB power consumption by more than 40%(from 4.80 to 2.64 Watts)compared with the conventional PD control method.Additionally,the H-infinity controller can prevent vibrational instability of the rotor nutation mode,which is prone to occur when operating with high rotational speeds.展开更多
基金Supported by the Key Research&Development Program of Shaanxi Province of China,No.2024SF-YBXM-447Institutional Foundation of The First Affiliated Hospital of Xi’an Jiaotong University,No.2022MS-07+1 种基金Fundamental Research Funds for the Central Universities,No.xzy022023068Natural Science Foundation of Shaanxi Province,No.2023-JC-QN-0814.
文摘BACKGROUND The magnetic compression technique has been used to establish an animal model of tracheoesophageal fistula(TEF),but the commonly shaped magnets present limitations of poor homogeneity of TEF and poor model control.We designed a Tshaped magnet system to overcome these problems and verified its effectiveness via animal experiments.AIM To investigate the effectiveness of a T-shaped magnet system for establishing a TEF model in beagle dogs.METHODS Twelve beagles were randomly assigned to groups in which magnets of the Tshaped scheme(study group,n=6)or normal magnets(control group,n=6)were implanted into the trachea and esophagus separately under gastroscopy.Operation time,operation success rate,and accidental injury were recorded.After operation,the presence and timing of cough and the time of magnet shedding were observed.Dogs in the control group were euthanized after X-ray and gastroscopy to confirm establishment of TEFs after coughing,and gross specimens of TEFs were obtained.Dogs in the study group were euthanized after X-ray and gastroscopy 2 wk after surgery,and gross specimens were obtained.Fistula size was measured in all animals,and then harvested fistula specimens were examined by hematoxylin and eosin(HE)and Masson trichrome staining.RESULTS The operation success rate was 100%for both groups.Operation time did not differ between the study group(5.25 min±1.29 min)and the control group(4.75 min±1.70 min;P=0.331).No bleeding,perforation,or unplanned magnet attraction occurred in any animal during the operation.In the early postoperative period,all dogs ate freely and were generally in good condition.Dogs in the control group had severe cough after drinking water at 6-9 d after surgery.X-ray indicated that the magnets had entered the stomach,and gastroscopy showed TEF formation.Gross specimens of TEFs from the control group showed the formation of fistulas with a diameter of 4.94 mm±1.29 mm(range,3.52-6.56 mm).HE and Masson trichrome staining showed scar tissue formation and hierarchical structural disorder at the fistulas.Dogs in the study group did not exhibit obvious coughing after surgery.X-ray examination 2 wk after surgery indicated fixed magnet positioning,and gastroscopy showed no change in magnet positioning.The magnets were removed using a snare under endoscopy,and TEF was observed.Gross specimens showed well-formed fistulas with a diameter of 6.11 mm±0.16 mm(range,5.92-6.36 mm),which exceeded that in the control group(P<0.001).Scar formation was observed on the internal surface of fistulas by HE and Masson trichrome staining,and the structure was more regular than that in the control group.CONCLUSION Use of the modified T-shaped magnet scheme is safe and feasible for establishing TEF and can achieve a more stable and uniform fistula size compared with ordinary magnets.Most importantly,this model offers better controllability,which improves the flexibility of follow-up studies.
文摘HT7U is a large fusion experimental device. It will be built in the Institute of Plasma Physics of Chinese Academy of Sciences. The mission of HT-7U is to develop the scientific basis for a continuously operating tokama-k fusion reactor. This paper describes only a toroidal field (TF) superconducting magnet system of HT7U. In this paper, design criteria of conductor and stability analysis, coil winding and support structure design of magnet system, mechanical calculation and stress analysis, heat load evaluation are given.
基金supported by the Intemational Thermonuclear Experimental Reactor Special Fund of China(No.2009GB102001)Cooperation on Key Technology of Plasma Heating in Tokamak(No.2010DFA63860)Critical Technology Research of Nuclear Fusion and Physical Experiments and on HL-2A Tokamak(No.H660003)
文摘A 5.8 T cryogen-free superconducting magnet (SCM) system with a warm bore hole of 160 mm in diameter, used for gyrotrons operating in the frequency range from 68 GHz to 140 GHz, is installed on the site of the HL-2A tokamak. The SCM consists of two separate solenoidal magnetic coils connected in series, a 4.2 K Gifford-McMahon (GM) refrigerator, a com- pressor, a coil power supply and two temperature monitors. The performance, test and preliminary experimental results of this SCM system are described in this paper. The magnetic field distribu- tion was measured along the axis, and a dummy tube was used for adjusting the magnet system. Finally, the magnet was used for the operation of a 68 GHz/500 kW gyrotron, which is part of an electron cyclotron resonance heating (ECRH) system. With an additional auxiliary coil and after adjusting tile magnet system, a maximum output power for the ECRH system of up to 400 kW was achieved.
基金The project supported by the Korea Ministry of Science and Technology under the KSTAR Project
文摘The mission of Korea Superconducting Tokamak Advanced Research (KSTAR)project is to develop an advanced steady-state superconducting tokamak for establishing a scientificand technological basis for an attractive fusion reactor. Because one of the KSTAR mission is toachieve a steady-state operation, the use of superconducting coils is an obvious choice for themagnet system. The KSTAR superconducting magnet system consists of 16 Toroidal Field (TF) coils and14 Poloidal Field (PF) coils. Internally-cooled Cable-In-Conduit Conductors (CICC) are put into usein both the TF and PF coil systems. The TF coil system provides a field of 3.5 T at the plasmacenter and the PF coil system is able to provide a flux swing of 17 V-sec. The major achievement inKSTAR magnet-system development includes the development of CICC, the development of a full-size TFmodel coil, the development of a coil system for background magnetic-field generation , theconstruction of a large-scale superconducting magnet and CICC test facility. TF and PF coils are inthe stage of fabrication to pave the way for the scheduled completion of KSTAR by the end of 2006.
文摘For power plants heliotron-type reactors have attractive advantages, such asno current-disruptions, no current-drive, and wide space between helical coils for the maintenanceof in-vessel components. However, one disadvantage is that a major radius has to be large enough toobtain large Q-value or to produce sufficient space for blankets. Although the larger radius isconsidered to increase the construction cost, the influence has not been understood clearly, yet.Scale effects on superconducting magnet systems have been estimated under the conditions of aconstant energy confinement time and similar geometrical parameters. Since the necessary magneticfield with a larger radius becomes lower, the increase rate of the weight of the coil support to themajor radius is less than the square root. The necessary major radius will be determined mainly bythe blanket space. The appropriate major radius will be around 13 m for a reactor similar to theLarge Helical Device (LHD).
基金the scope of the CICS-UBI projects UIDP/Multi/00709/2019,UIDB/Multi/00709/2019,UIDP/00709/2020,UIDB/00709/2020,financed by national funds through the Portuguese Foundation for Science and Technology/MCTESby funds to the PPBI-Portuguese Platform of Bio Imaging through the Project POCI-01-0145-FEDER-022122(to GB,MVP,NP)supported by a grant from the Portuguese Foundation for Science and Technology/MCTES(2021.07854.BD)(to IS)。
文摘Repetitive transcranial magnetic stimulation has been increasingly studied in different neurological diseases,and although most studies focus on its effects on neuronal cells,the contribution of nonneuronal cells to the improvement trigge red by repetitive transcranial magnetic stimulation in these diseases has been increasingly suggested.To systematically review the effects of repetitive magnetic stimulation on non-neuronal cells two online databases.Web of Science and PubMed were searched fo r the effects of high-frequency-repetitive transcranial magnetic stimulation,low-frequencyrepetitive transcranial magnetic stimulation,intermittent theta-bu rst stimulation,continuous thetaburst stimulation,or repetitive magnetic stimulation on non-neuronal cells in models of disease and in unlesioned animals or cells.A total of 52 studies were included.The protocol more frequently used was high-frequency-repetitive magnetic stimulation,and in models of disease,most studies report that high-frequency-repetitive magnetic stimulation led to a decrease in astrocyte and mic roglial reactivity,a decrease in the release of pro-inflammatory cyto kines,and an increase of oligodendrocyte proliferation.The trend towards decreased microglial and astrocyte reactivity as well as increased oligodendrocyte proliferation occurred with intermittent theta-burst stimulation and continuous theta-burst stimulation.Few papers analyzed the low-frequency-repetitive transcranial magnetic stimulation protocol,and the parameters evaluated were restricted to the study of astrocyte reactivity and release of pro-inflammatory cytokines,repo rting the absence of effects on these paramete rs.In what concerns the use of magnetic stimulation in unlesioned animals or cells,most articles on all four types of stimulation reported a lack of effects.It is also important to point out that the studies were developed mostly in male rodents,not evaluating possible diffe rential effects of repetitive transcranial magnetic stimulation between sexes.This systematic review supports that thro ugh modulation of glial cells repetitive magnetic stimulation contributes to the neuroprotection or repair in various neurological disease models.Howeve r,it should be noted that there are still few articles focusing on the impact of repetitive magnetic stimulation on non-neuronal cells and most studies did not perform in-depth analyses of the effects,emphasizing the need for more studies in this field.
基金Project supported by the National Natural Science Foundation of China(No.12372005)。
文摘The modeling and self-excited vibration mechanism in the magnetic levitation-collision interface coupling system are investigated.The effects of the control and interface parameters on the system's stability are analyzed.The frequency range of self-excited vibrations is investigated from the energy point of view.The phenomenon of self-excited vibrations is elaborated with the phase trajectory.The corresponding control strategies are briefly analyzed with respect to the vibration mechanism.The results show that when the levitation objects collide with the mechanical interface,the system's vibration frequency becomes larger with the decrease in the collision gap;when the vibration frequency exceeds the critical frequency,the electromagnetic system continues to provide energy to the system,and the collision interface continuously dissipates energy so that the system enters the self-excited vibration state.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.11975087,42261134533,and 42011530086)the National Magnetic Confinement Fusion Energy Research and Development Program of China(Grant No.2022YFE03190400)the Heilongjiang Touyan Innovation Team Program,China.
文摘Magnetic reconnection processes in three-dimensional(3D)complex field configurations have been investigated in different magneto-plasma systems in space,laboratory,and astrophysical systems.Two-dimensional(2D)features of magnetic reconnection have been well developed and applied successfully to systems with symmetrical property,such as toroidal fusion plasmas and laboratory experiments with an axial symmetry.But in asymmetric systems,the 3D features are inevitably different from those in the 2D case.Magnetic reconnection structures in multiple celestial body systems,particularly star-planet-Moon systems,bring fresh insights to the understanding of the 3D geometry of reconnection.Thus,we take magnetic reconnection in an ancient solar-lunar terrestrial magneto-plasma system as an example by using its crucial parameters approximately estimated already and also some specific applications in pathways for energy and matter transports among Earth,ancient Moon,and the interplanetary magnetic field(IMF).Then,magnetic reconnection of the ancient lunar-terrestrial magnetospheres with the IMF is investigated numerically in this work.In a 3D simulation for the Earth-Moon-IMF system,topological features of complex magnetic reconnection configurations and dynamical characteristics of magnetic reconnection processes are studied.It is found that a coupled lunar-terrestrial magnetosphere is formed,and under various IMF orientations,multiple X-points emerge at distinct locations,showing three typical magnetic reconnection structures in such a geometry,i.e.,the X-line,the triple current sheets,and the A-B null pairs.The results can conduce to further understanding of reconnection physics in 3D for plasmas in complex magnetic configurations,and also a possible mechanism for energy and matters transport in evolutions of similar astrophysical systems.
基金National Natural Science Foundation of China(No.51977214)。
文摘A high-sensitivity magnetic sensing system based on giant magneto-impedance(GMI)effect is designed and fabricated.The system comprises a GMI sensor equipped with a gradient probe and an signal acquisition and processing module.A segmented superposition algorithm is used to increase target signal and reduce the random noise.The results show that under unshielded,room temperature conditions,the system achieves successful detection of weak magnetic fields down to 2 pT with a notable sensitivity of 1.84×108V/T(G=1000).By applying 17 overlays,the segmented superposition algorithm increases the power proportion of the target signal at 31 Hz from6.89%to 45.91%,surpassing the power proportion of the 2 Hz low-frequency interference signal.Simultaneously,it reduces the power proportion of the 20 Hz random noise.The segmented superposition process effectively cancels out certain random noise elements,leading to a reduction in their respective power proportions.This high-sensitivity magnetic sensing system features a simple structure,and is easy to operate,making it highly valuable for both practical applications and broader dissemination.
基金by The Tianjin Key Medical Discipline(Specialty)Construction Project,No.TJYXZDXK-074C.
文摘BACKGROUND The liver imaging reporting and data system(LI-RADS)diagnostic table has 15 cells and is too complex.The diagnostic performance of LI-RADS for hepatocellular carcinoma(HCC)is not satisfactory on gadoxetic acid-enhanced magnetic resonance imaging(EOB-MRI).AIM To evaluate the ability of the simplified LI-RADS(sLI-RADS)to diagnose HCC on EOB-MRI.METHODS A total of 331 patients with 356 hepatic observations were retrospectively analysed.The diagnostic performance of sLI-RADS A-D using a single threshold was evaluated and compared with LI-RADS v2018 to determine the optimal sLIRADS.The algorithms of sLI-RADS A-D are as follows:The single threshold for sLI-RADS A and B was 10 mm,that is,classified observations≥10mm using an algorithm of 10-19 mm observations(sLI-RADS A)and≥20 mm observations(sLI-RADS B)in the diagnosis table of LI-RADS v2018,respectively,while the classification algorithm remained unchanged for observations<10 mm;the single threshold for sLI-RADS C and D was 20 mm,that is,for<20 mm observations,the algorithms for<10 mm observations(sLI-RADS C)and 10-19 mm observations(sLI-RADS D)were used,respectively,while the algorithm remained unchanged for observations≥20 mm.With hepatobiliary phase(HBP)hypointensity as a major feature(MF),the final sLI-RADS(F-sLI-RADS)was formed according to the optimal sLI-RADS,and its diagnostic performance was evaluated.The times needed to classify the observations according to F-sLIRADS and LI-RADS v2018 were compared.RESULTS The optimal sLI-RADS was sLI-RADS D(with a single threshold of 20 mm),because its sensitivity was greater than that of LI-RADS v2018(89.8%vs 87.0%,P=0.031),and its specificity was not lower(89.4%vs 90.1%,P>0.999).With HBP hypointensity as an MF,the sensitivity of F-sLI-RADS was greater than that of LI-RADS v2018(93.0%vs 87.0%,P<0.001)and sLI-RADS D(93.0%vs 89.8%,P=0.016),without a lower specificity(86.5%vs 90.1%,P=0.062;86.5%vs 89.4%,P=0.125).Compared with that of LI-RADS v2018,the time to classify lesions according to FsLI-RADS was shorter(51±21 s vs 73±24 s,P<0.001).CONCLUSION The use of sLI-RADS with HBP hypointensity as an MF may improve the sensitivity of HCC diagnosis and reduce lesion classification time.
文摘Permanent magnet synchronous motor(PMSM)speed control systems with conventional linear active disturbance rejection control(CLADRC)strategy encounter issues regarding the coupling between dynamic response and disturbance suppression and have poor performance in suppressing complex nonlinear disturbances.In order to address these issues,this paper proposes an improved two-degree-of-freedom LADRC(TDOF-LADRC)strategy,which can enhance the disturbance rejection performance of the system while decoupling entirely the system's dynamic and anti-disturbance performance to boost the system robustness and simplify controller parameter tuning.PMSM models that consider total disturbances are developed to design the TDOF-LADRC speed controller accurately.Moreover,to evaluate the control performance of the TDOF-LADRC strategy,its stability is proven,and the influence of each controller parameter on the system control performance is analyzed.Based on it,a comparison is made between the disturbance observation ability and anti-disturbance performance of TDOF-LADRC and CLADRC to prove the superiority of TDOF-LADRC in rejecting disturbances.Finally,experiments are performed on a 750 W PMSM experimental platform,and the results demonstrate that the proposed TDOF-LADRC exhibits the properties of two degrees of freedom and improves the disturbance rejection performance of the PMSM system.
文摘BACKGROUND After approval for clinical use in 2017 early investigations of ultra-high-field abdominal magnetic resonance imaging(MRI)have demonstrated the feasibility as well as diagnostic capabilities of liver,kidney,and prostate MRI at 7-Tesla.However,the elevation of the field strength to 7-Tesla not only brought advantages to abdominal MRI but also presented considerable challenges and drawbacks,primarily stemming from heightened artifacts and limitations in Specific Absorption Rate,etc.Furthermore,evidence in the literature is relatively scarce concerning human studies in comparison to phantom/animal studies which necessitates an investigation into the evidence so far in humans and summarizing all relevant evidence.AIM To offer a comprehensive overview of current literature on clinical abdominal 7T MRI that emphasizes current trends,details relevant challenges,and provides a concise set of potential solutions.METHODS This systematic review adheres to Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines.A PubMed search,utilizing Medical Subject Headings terms such as"7-Tesla"and organ-specific terms,was conducted for articles published between January 1,1985,and July 25,2023.Eligibility criteria included studies exploring 7T MRI for imaging human abdominal organs,encompassing various study types(in-vivo/ex-vivo,method development,reviews/meta-analyses).Exclusion criteria involved animal studies and those lacking extractable data.Study selection involved initial identification via title/abstract,followed by a full-text review by two researchers,with discrepancies resolved through discussion.Data extraction covered publication details,study design,population,sample size,7T MRI protocol,image characteristics,endpoints,and conclusions.RESULTS The systematic review included a total of 21 studies.The distribution of clinical 7T abdominal imaging studies revealed a predominant focus on the prostate(n=8),followed by the kidney(n=6)and the hepatobiliary system(n=5).Studies on these organs,and in the pancreas,demonstrated clear advantages at 7T.However,small bowel studies showed no significant improvements compared to traditional MRI at 1.5T.The majority of studies evaluated originated from Germany(n=10),followed by the Netherlands(n=5),the United States(n=5),Austria(n=2),the United Kingdom(n=1),and Italy(n=1).CONCLUSION Further increase of abdominal clinical MRI field strength to 7T demonstrated high imaging potential,yet also limitations mainly due to the inhomogeneous radiofrequency(RF)excitation field relative to lower field strengths.Hence,further optimization of dedicated RF coil elements and pulse sequences are expected to better optimize clinical imaging at high magnetic field strength.
文摘Amblyopia is the most common cause of vision loss in children and can persist into adulthood in the absence of effective intervention.Previous clinical and neuroimaging studies have suggested that the neural mechanisms underlying strabismic amblyopia and anisometropic amblyopia may be different.Therefore,we performed a systematic review of magnetic resonance imaging studies investigating brain alterations in patients with these two subtypes of amblyopia;this study is registered with PROSPERO(registration ID:CRD42022349191).We searched three online databases(PubMed,EMBASE,and Web of Science) from inception to April 1,2022;39 studies with 633 patients(324patients with anisometropic amblyo pia and 309 patients with strabismic amblyopia) and 580 healthy controls met the inclusion criteria(e.g.,case-control designed,pee r-reviewed articles) and were included in this review.These studies highlighted that both strabismic amblyopia and anisometropic amblyopia patients showed reduced activation and distorted topological cortical activated maps in the striate and extrastriate co rtices during tas k-based functional magnetic resonance imaging with spatial-frequency stimulus and retinotopic representations,respectively;these may have arisen from abnormal visual experiences.Compensations for amblyopia that are reflected in enhanced spontaneous brain function have been reported in the early visual cortices in the resting state,as well as reduced functional connectivity in the dorsal pathway and structural connections in the ventral pathway in both anisometro pic amblyopia and strabismic amblyopia patients.The shared dysfunction of anisometro pic amblyopia and strabismic amblyopia patients,relative to controls,is also chara cterized by reduced spontaneous brain activity in the oculomotor co rtex,mainly involving the frontal and parietal eye fields and the cerebellu m;this may underlie the neural mechanisms of fixation instability and anomalous saccades in amblyopia.With regards to specific alterations of the two forms of amblyo pia,anisometropic amblyo pia patients suffer more microstructural impairments in the precortical pathway than strabismic amblyopia patients,as reflected by diffusion tensor imaging,and more significant dysfunction and structural loss in the ventral pathway.Strabismic amblyopia patients experience more attenuation of activation in the extrastriate co rtex than in the striate cortex when compared to anisometropic amblyopia patients.Finally,brain structural magnetic resonance imaging alterations tend to be lateralized in the adult anisometropic amblyopia patients,and the patterns of brain alterations are more limited in amblyopic adults than in childre n.In conclusion,magnetic resonance imaging studies provide important insights into the brain alterations underlying the pathophysiology of amblyopia and demonstrate common and specific alte rations in anisometropic amblyo pia and strabismic amblyopia patients;these alterations may improve our understanding of the neural mechanisms underlying amblyopia.
基金support from the UK Space Agency under Grant Number ST/T002964/1partly supported by the International Space Science Institute(ISSI)in Bern,through ISSI International Team Project Number 523(“Imaging the Invisible:Unveiling the Global Structure of Earth’s Dynamic Magnetosphere”)。
文摘The Solar wind Magnetosphere Ionosphere Link Explorer(SMILE)Soft X-ray Imager(SXI)will shine a spotlight on magnetopause dynamics during magnetic reconnection.We simulate an event with a southward interplanetary magnetic field turning and produce SXI count maps with a 5-minute integration time.By making assumptions about the magnetopause shape,we find the magnetopause standoff distance from the count maps and compare it with the one obtained directly from the magnetohydrodynamic(MHD)simulation.The root mean square deviations between the reconstructed and MHD standoff distances do not exceed 0.2 RE(Earth radius)and the maximal difference equals 0.24 RE during the 25-minute interval around the southward turning.
基金supported by the National Magnetic Confinement Fusion Program of China(Nos.2018YFE0302100 and 2022YFE03010002)National Natural Science Foundation of China(Nos.12205195)。
文摘In EAST long-pulsed discharge(hundreds of seconds),electric magnetic diagnosis(EMD)is very important,since EMD not only monitors tokamak security status but also provides accurate measurement accuracy for reconstruction of the plasma boundary.To avoid current measurement drift,a fiber optic current sensor,based on the Faraday effect,is developed and used for poloidal and plasma current feedback control for the first time,relative current measurement accuracy is within 0.5%.To ensure plasma boundary control accuracy,a detailed set of magnetic measurement calibration methods is developed before the plasma discharge.The maximum relative error is less than 1%,the corresponding control accuracy is within 1 cm.To minimize integrator drift error,a long-pulse integrator test is essential,the corresponding drift error needs to be subtracted in plasma control system.Besides,the saddle coil and Mirnov coil not only help to detect MHD issues,but are also utilized for plasma disruption prediction during the long-pulse discharge.
文摘To determine the cause(s)of perturbations seen in dayside equatorial ground magnetograms,we conducted a systematic survey of simultaneous ground-based and geosynchronous satellite-based observations during the 90-day period from December 1,2020 to February 28,2021.We examined Huancayo ground magnetometer observations from 14:00:00 to 20:00:00 UT each day,during which Huancayo passed through local noon.From those data we chose perturbation events selected on the basis of large(>20 nT)event amplitude and classified the selected events as responding primarily to solar wind pressure,or to variations in the north/south component of the interplanetary magnetic field(IMF Bz),or perhaps in part to both.The results show that an equivalent number of events were identified for each model during this 90-day period.Variations in the lagged solar wind dynamic pressure routinely correspond to nearly simultaneous sudden impulses recorded at both geosynchronous orbit and on the ground.Variations in IMF Bz produce erosion signatures at geosynchronous orbit and can correspond to ground events if lag times for reconnection to enhance convection in the magnetosphere are taken into account.
基金the National Key R&D Program of China(2017YFC1501501)the CAS Project of Stable Support for Youth Team in Basic Research Field(YSRR-018)+3 种基金the Youth Innovation Fund project of the university(WK2080000172)the National Natural Science Foundation of China(41875006,U1938115)the Chinese Meridian Projectthe International Partnership Program of Chinese Academy of Sciences(183311KYSB20200003).
文摘A low-frequency magnetic lightning mapping system(LFM-LMS)was built during the SHAndong Triggered Lightning Experiment(SHATLE),based on continuous measurements of magnetic field radiation from lightning.The hardware and source-mapping techniques used by the LFM-LMS were introduced;both Monte Carlo simulations and the observation of rocket-triggered lightning examples were employed to examine the location accuracy and detection effectiveness of the LFM-LMS.We estimated that the system’s location accuracy about 100−200 m horizontally and~200 m vertically.A natural intra-cloud lightning flash and a rocket-triggered lightning flash,both with intricate structures and discharging processes,were examined using the three-dimensional mapping results.The progressing path of negative lightning leaders is usually well-defined,and its propagation speed is estimated to be(0.5−1.4)×10^(6)m/s.In summary,the LFM-LMS can reconstruct the three-dimensional morphology of lightning flashes;this technology provides a efficient method for investigating the characteristics of lightning development,as well as the overall electrical strucuture of thunderstorms.
文摘We construct a mapped bilayer quantum Hall system to realize the proposal that two nearly flatbands have opposite Chern numbers.For the C=±1 case,the two Landau levels of the bilayer experience opposite magnetic fields.We consider a mapped bilayer quantum Hall system at total fillingν_(t)=1/2+1/2where the intralayer interaction is repulsive and the interlayer interaction is attractive.We take exact diagonalization(ED)calculations on a torus to study the phase transition when the separation distance d/l_(B)is driven.The critical point at d_(c)/l_(B)=0.68 is characterized by a collapse of degeneracy and a crossing of energy levels.In the region d/l_(B)<d_(c)/l_(B),the states of each level are highly degenerate.The pair-correlation function indicates electrons with opposite pseudo-spins are strong correlated at r=0.We find an exciton stripe phase composed of bound pairs.The ferromagnetic ground state is destroyed by the strong effective attractive potential.An electron composite-Fermion(eCF)and a hole composite Fermion(hCF)are tightly bound.In the region d/lB>d_(c)/l_(B),a crossover from the d→d_(c)limit to the large d limit is observed.The electron and hole composite Fermion liquids(CFL)are realized by composite Fermions(CF)which attach opposite fluxes,respectively.
基金supported by the National Key R&D Program of China (Grant Nos.2022YFB3904001, 2022YFB3904004, and 2018YFA0307500)the National Natural Science Foundation of China (Grant Nos. 12022414 and 12121004)+3 种基金the CAS Youth Innovation Promotion Association (Grant Nos. Y201963 and Y2022099)the Natural Science Foundation of Hubei Province (Grant No. 2022CFA013)the CAS Project for Young Scientists in Basic Research (Grant No. YSBR-055)the Interdisciplinary Cultivation Project of the Innovation Academy for Precision Measurement of Science and Technology (Grant No. S21S2201)。
文摘Future applications of portable40Ca^(+)optical clocks require reliable magnetic field stabilization to improve frequency stability, which can be achieved by implementing an active and passive magnetic field noise suppression system. On the one hand, we have optimized the magnetic shielding performance of the portable optical clock by reducing its apertures and optimizing its geometry;on the other hand, we have introduced an active magnetic field noise suppression system to further suppress the magnetic field noise experienced by the ions. These efforts reduced the ambient magnetic field noise by about 10000 times, significantly reduced the linewidth of the clock transition spectrum, improved the stability of the portable40Ca+optical clock, and created the conditions for using portable optical clocks in non-laboratory magnetic field environments. This active magnetic field suppression scheme has the advantages of simple installation and wide applicability.
基金supported by Thailand Science Research and Innovation and the National Research Council of Thailand under Grant RGU6280014.
文摘This paper presents a theoretical and experimental study on controller design for the AMBs in a small-scale flywheel energy storage system,where the main goals are to achieve low energy consumption and improved rotordynamic stability.A H-infinity optimal control synthesis procedure is defined for the permanent-magnet-biased AMB-rotor system with 4 degrees of freedom.Through the choice of design weighting functions,notch filter characteristics are incorporated within the controller to reduce AMB current components caused by rotor vibration at the synchronous frequency and higher harmonics.Experimental tests are used to validate the controller design methodology and provide comparative results on performance and efficiency.The results show that the H-infinity controller is able to achieve stable rotor levitation and reduce AMB power consumption by more than 40%(from 4.80 to 2.64 Watts)compared with the conventional PD control method.Additionally,the H-infinity controller can prevent vibrational instability of the rotor nutation mode,which is prone to occur when operating with high rotational speeds.