In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magne...In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magnetometer studied can reduce the frequency noise of system and improve the magnetic sensitivity by microwave frequency modulation.Firstly,ESR spectra by sweeping the microwave frequency was obtained.Further,the microwave frequency modulated was gained through the mixed high-frequency sinusoidal modulation signal generated by signal generator.In addition,the frequency through the lock-in amplifier was locked,and the signal which was proportional to the first derivative of the spectrum was obtained.The experimental results show that the sensitivity of magnetic field detection can reach 17.628 nT/Hz based on microwave frequency modulation technology.The method realizes high resolution and sensitivity for magnetic field detection.展开更多
Petroleum exploration is a strategic task for our country in its economic development.At present,petroleum production in most of east China’s oilfields is in the waning period after reaching a peak.To raise the oil r...Petroleum exploration is a strategic task for our country in its economic development.At present,petroleum production in most of east China’s oilfields is in the waning period after reaching a peak.To raise the oil recovery rate is a key measure for their production increase.Because of this,a major provision was included in the third cooperative protocol signed in 1986 by the展开更多
BACKGROUND Tibial plateau fracture is one of the common fracture types.It occurs mainly in teenagers and is usually caused by a fall.After the occurrence of fracture,knee swelling,pain,limited activity,etc.greatly aff...BACKGROUND Tibial plateau fracture is one of the common fracture types.It occurs mainly in teenagers and is usually caused by a fall.After the occurrence of fracture,knee swelling,pain,limited activity,etc.greatly affect the patient’s exercise habits and lifestyle.X-ray,computed tomography(CT)and magnetic resonance imaging(MRI)were used in this examination.X-rays are relatively new and easy to operate.However,there are some errors in the observation of fracture collapse and fracture displacement.In recent years,CT and MRI have been actively used to diagnose various types of clinical fractures.They have more diagnostic power than X-ray film.However,some scholars believe that CT is also prone to errors in clinical application.The volume effect leads to missed diagnosis and misdiagnosis in some cases,while the multidirection scanning of MRI technology can effectively overcome the shortcomings of CT.To facilitate the selection of clinical examination regimens,this study further observed the diagnostic ability of these two regimens in the diagnosis of tibial plateau fractures.AIM To explore the value of nuclear MRI and CT in the clinical diagnosis of tibial plateau fractures.METHODS A total of 120 patients with tibial plateau fractures admitted from September 2017 to August 2019 were included.All patients were examined by nuclear MRI and CT scanning.The results were sent to senior physicians in our hospital to complete the diagnosis.RESULTS Nuclear magnetic resonance showed the same effects as CT in four aspects:fracture displacement,bone defect,fracture site and fracture comminution.There was no significant difference in the score data(P>0.05).Nuclear magnetic resonance and CT tended to be consistent in the B3,C2 and C3 fracture diagnosis coincidence rate,combined injury detection rate and fracture detection rate.The diagnostic coincidence rate of type B1,B2 and C1 fractures and the accuracy rate of overall fracture classification indicated that the MRI technique was significantly better than that of CT(P>0.05).CONCLUSION MRI and CT have good diagnostic typing in the diagnosis of tibial plateau fractures,but MRI is more accurate and may be preferred.展开更多
Bit-Pattemed Magnetic Recording(BPMR)is one of the emerging data storage technologies,which promises an Areal Density(AD)of about 4 Tb/in2.However,a major problem practically encountered in a BPMR system is Inter-Trac...Bit-Pattemed Magnetic Recording(BPMR)is one of the emerging data storage technologies,which promises an Areal Density(AD)of about 4 Tb/in2.However,a major problem practically encountered in a BPMR system is Inter-Track Interference(ITI)that can deteriorate the overall system performance,especially at high ADs.This paper proposes an iterative ITI cancellation method for an m-head m-track BPMR system,which uses m heads to read m adjacent tracks and decodes them simultaneously.To cancel the ITI,we subtract the weighted readback signals of adjacent tracks,acting as the ITI signals,from the readback signal of the target track,before passing the refined readback signal to a turbo decoder.Then,the decoded data will be employed to reconstruct the ITI signal for the next turbo iteration.Experimental results indicate that the proposed system performs better than the conventional system that uses one head to read one data track.Furthermore,we also find out that the proposed system is more robust to media noise and track misregistration than the conventional system.展开更多
A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accu...A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accurately,we establish corresponding equivalent mathematical model considering magnetic leakage based on magnetic circuit and circuit dualistic transformation method.The distribution of magnetic leakage field of each winding is analyzed qualitatively,and the analytical calculation formulas of magnetizing inductance and leakage inductance of each winding are derived.Based on this,the analytical calculation formulas of short-circuit impedance and winding current of CRT under different working conditions are derived.The field-circuit coupling finite element model of the magnetic integrated CRT is established to simulate the current of each winding under different working conditions.The results show that the analytical calculation results of each winding current have good consistency with the finite element calculation results,indicating the validity of CRT equivalent mathematical model and correctness of the analytical formulas of leakage inductance,short-circuit impedance and winding current of CRT.The working winding current of CRT is increasing gradually with the operation of control winding in turn to realise the transition of CRT compensation capacity from zero to a rated value.展开更多
Nanofluids based direct absorption solar collectors(DASCs) are considered as the important alternative for further improve the utilization of solar energy. However the low-quality energy and aggregation of nanoparticl...Nanofluids based direct absorption solar collectors(DASCs) are considered as the important alternative for further improve the utilization of solar energy. However the low-quality energy and aggregation of nanoparticles obstructs their large-scale application. In this work, a new method of using magnetic nanofluids in DASCs is proposed. By this method, not only high-quality energy is got as well as the problems of blockage and corrosion in heat exchanger are well avoided. The result shows that the maximum temperature can reach 98℃ under 3 solar irradiations and the photothermal conversion efficiency can be further increased by 12.8% when the concentration is 500 ppm after adding an external rotating magnetic field. The highest viscosity of working fluid reduced by 21% when the concentration is 500 ppm at 95℃ after separating the Fe_(3)O_(4)@C nanoparticles from the nanofluids via magnetic separation technology. Meanwhile, the obtained pure base liquids with high temperature flow to heat exchanger, which also reduces the flow resistance in pipeline and avoids the problems such as blockage and corrosion in heat exchanger. This research promotes a new way for the efficient utilization of solar energy.展开更多
To classify different walnut varieties based on water and oil content of walnut,and determine their storage conditions,the low-field nuclear magnetic resonance(LFNMR)technology was used to obtain the NMR transverse re...To classify different walnut varieties based on water and oil content of walnut,and determine their storage conditions,the low-field nuclear magnetic resonance(LFNMR)technology was used to obtain the NMR transverse relaxation time(T 2)of the samples based on the physical and chemical indicators of the walnut quality.The relationship between the relaxation time and phase state of the internal material of the sample was investigated,and the characteristic parameters of the NMR spectrum signals were statistically analyzed using cluster analysis to determine the different walnut varieties,and three different components,as well as their contents,were detected by a LFNMR spectrometer:firmly bound water,weakly bound water,and weakly bound oil.Test results indicated that the oil peak was dominant in the overall signal intensity compared to the water peaks,in which the firmly bound water phase contributed more to the overall water signal between the water peaks.Using the analytic hierarchy process of cluster analysis,21 walnut samples were classified into three different classes,based on the characteristic parameters of the water-content and oil-content spectrum signals.The first class contains four walnut varieties characterized by least water and highest oil contents;the third class contains two walnut varieties,with the highest water content and least oil content;whereas,the second class contains 15 walnut varieties,with both water and oil contents at medium levels.The results showed that LFNMR led to a rapid detection of moisture and oil contents in walnuts,while cluster analysis classified different walnuts varieties based on these parameters.This study also provided the basis for optimizing the storage methods and storage conditions of walnuts.展开更多
This article introduces the solid acid catalyst for isobutene/butylenes alkylation, the HTS Ti/Si zeolite for ammonoxidation of cyclohexanone and the noncrystalline alloy catalyst and magnetically stabi- lized bed for...This article introduces the solid acid catalyst for isobutene/butylenes alkylation, the HTS Ti/Si zeolite for ammonoxidation of cyclohexanone and the noncrystalline alloy catalyst and magnetically stabi- lized bed for hydrofining of caprolactam that were developed recently by SINOPEC Research Institute of Petroleum Processing (RIPP).展开更多
基金National Natural Science Foundation of China(Nos.51635011,61503346,51727808)National Science Foundation of Shanxi Province(No.201701D121080)
文摘In view of the low resolution and accuracy of traditional magnetometer,a method of microwave frequency modulation technology based on nitrogen-vacancy(NV)center in diamond for magnetic detection was proposed.The magnetometer studied can reduce the frequency noise of system and improve the magnetic sensitivity by microwave frequency modulation.Firstly,ESR spectra by sweeping the microwave frequency was obtained.Further,the microwave frequency modulated was gained through the mixed high-frequency sinusoidal modulation signal generated by signal generator.In addition,the frequency through the lock-in amplifier was locked,and the signal which was proportional to the first derivative of the spectrum was obtained.The experimental results show that the sensitivity of magnetic field detection can reach 17.628 nT/Hz based on microwave frequency modulation technology.The method realizes high resolution and sensitivity for magnetic field detection.
文摘Petroleum exploration is a strategic task for our country in its economic development.At present,petroleum production in most of east China’s oilfields is in the waning period after reaching a peak.To raise the oil recovery rate is a key measure for their production increase.Because of this,a major provision was included in the third cooperative protocol signed in 1986 by the
文摘BACKGROUND Tibial plateau fracture is one of the common fracture types.It occurs mainly in teenagers and is usually caused by a fall.After the occurrence of fracture,knee swelling,pain,limited activity,etc.greatly affect the patient’s exercise habits and lifestyle.X-ray,computed tomography(CT)and magnetic resonance imaging(MRI)were used in this examination.X-rays are relatively new and easy to operate.However,there are some errors in the observation of fracture collapse and fracture displacement.In recent years,CT and MRI have been actively used to diagnose various types of clinical fractures.They have more diagnostic power than X-ray film.However,some scholars believe that CT is also prone to errors in clinical application.The volume effect leads to missed diagnosis and misdiagnosis in some cases,while the multidirection scanning of MRI technology can effectively overcome the shortcomings of CT.To facilitate the selection of clinical examination regimens,this study further observed the diagnostic ability of these two regimens in the diagnosis of tibial plateau fractures.AIM To explore the value of nuclear MRI and CT in the clinical diagnosis of tibial plateau fractures.METHODS A total of 120 patients with tibial plateau fractures admitted from September 2017 to August 2019 were included.All patients were examined by nuclear MRI and CT scanning.The results were sent to senior physicians in our hospital to complete the diagnosis.RESULTS Nuclear magnetic resonance showed the same effects as CT in four aspects:fracture displacement,bone defect,fracture site and fracture comminution.There was no significant difference in the score data(P>0.05).Nuclear magnetic resonance and CT tended to be consistent in the B3,C2 and C3 fracture diagnosis coincidence rate,combined injury detection rate and fracture detection rate.The diagnostic coincidence rate of type B1,B2 and C1 fractures and the accuracy rate of overall fracture classification indicated that the MRI technique was significantly better than that of CT(P>0.05).CONCLUSION MRI and CT have good diagnostic typing in the diagnosis of tibial plateau fractures,but MRI is more accurate and may be preferred.
基金This work was supported by Research and Development Institute,Nakhon Pathom Rajabhat University,Thailand,under Grant GP_6212.
文摘Bit-Pattemed Magnetic Recording(BPMR)is one of the emerging data storage technologies,which promises an Areal Density(AD)of about 4 Tb/in2.However,a major problem practically encountered in a BPMR system is Inter-Track Interference(ITI)that can deteriorate the overall system performance,especially at high ADs.This paper proposes an iterative ITI cancellation method for an m-head m-track BPMR system,which uses m heads to read m adjacent tracks and decodes them simultaneously.To cancel the ITI,we subtract the weighted readback signals of adjacent tracks,acting as the ITI signals,from the readback signal of the target track,before passing the refined readback signal to a turbo decoder.Then,the decoded data will be employed to reconstruct the ITI signal for the next turbo iteration.Experimental results indicate that the proposed system performs better than the conventional system that uses one head to read one data track.Furthermore,we also find out that the proposed system is more robust to media noise and track misregistration than the conventional system.
基金Weinan Science and Technology Plan Project(No.2020ZDYF-JCYJ-177)General Special Scientific Research Projects of Education Department of Shaanxi Provincial Government(No.21JK0582)+2 种基金Young and Middle-aged Scientific and Technological Talents Project of Shaanxi Railway Institute(No.KJRC202001)Scientific Research Fund Project of Shaanxi Railway Institute(No.KY2021-34)Science and Technology Innovation Team of Shaanxi Railway Institute(No.KJTD201901)。
文摘A novel magnetic integrated controllable reactor of transformer type(CRT)has the advantages of simple structure,flexible assembly,convenient maintenance and practicability.To analyze its operation characteristics accurately,we establish corresponding equivalent mathematical model considering magnetic leakage based on magnetic circuit and circuit dualistic transformation method.The distribution of magnetic leakage field of each winding is analyzed qualitatively,and the analytical calculation formulas of magnetizing inductance and leakage inductance of each winding are derived.Based on this,the analytical calculation formulas of short-circuit impedance and winding current of CRT under different working conditions are derived.The field-circuit coupling finite element model of the magnetic integrated CRT is established to simulate the current of each winding under different working conditions.The results show that the analytical calculation results of each winding current have good consistency with the finite element calculation results,indicating the validity of CRT equivalent mathematical model and correctness of the analytical formulas of leakage inductance,short-circuit impedance and winding current of CRT.The working winding current of CRT is increasing gradually with the operation of control winding in turn to realise the transition of CRT compensation capacity from zero to a rated value.
基金supported by National Natural Science Foundation of China(51590901&51876112&51906132&51906123)Shanghai Municipal Natural Science Foundation(Grant No.17ZR1411000)+1 种基金the Key Subject of Shanghai Polytechnic University(Material Science and engineeringGrant Nos.XXKZD1601 and EGD18YJ0042)。
文摘Nanofluids based direct absorption solar collectors(DASCs) are considered as the important alternative for further improve the utilization of solar energy. However the low-quality energy and aggregation of nanoparticles obstructs their large-scale application. In this work, a new method of using magnetic nanofluids in DASCs is proposed. By this method, not only high-quality energy is got as well as the problems of blockage and corrosion in heat exchanger are well avoided. The result shows that the maximum temperature can reach 98℃ under 3 solar irradiations and the photothermal conversion efficiency can be further increased by 12.8% when the concentration is 500 ppm after adding an external rotating magnetic field. The highest viscosity of working fluid reduced by 21% when the concentration is 500 ppm at 95℃ after separating the Fe_(3)O_(4)@C nanoparticles from the nanofluids via magnetic separation technology. Meanwhile, the obtained pure base liquids with high temperature flow to heat exchanger, which also reduces the flow resistance in pipeline and avoids the problems such as blockage and corrosion in heat exchanger. This research promotes a new way for the efficient utilization of solar energy.
基金This project was supported by National Natural Science Foundation of China(Grant Nos.31701318 and 31601216)National Natural Science Foundation of China Projects of International Cooperation and Exchanges(Grant No.31811540396)+1 种基金National Key Research and Development Program of China(Grant No.2017YFD0701205)Doctoral Research Fund of Liaoning Province,China(Grant No.20170520202).
文摘To classify different walnut varieties based on water and oil content of walnut,and determine their storage conditions,the low-field nuclear magnetic resonance(LFNMR)technology was used to obtain the NMR transverse relaxation time(T 2)of the samples based on the physical and chemical indicators of the walnut quality.The relationship between the relaxation time and phase state of the internal material of the sample was investigated,and the characteristic parameters of the NMR spectrum signals were statistically analyzed using cluster analysis to determine the different walnut varieties,and three different components,as well as their contents,were detected by a LFNMR spectrometer:firmly bound water,weakly bound water,and weakly bound oil.Test results indicated that the oil peak was dominant in the overall signal intensity compared to the water peaks,in which the firmly bound water phase contributed more to the overall water signal between the water peaks.Using the analytic hierarchy process of cluster analysis,21 walnut samples were classified into three different classes,based on the characteristic parameters of the water-content and oil-content spectrum signals.The first class contains four walnut varieties characterized by least water and highest oil contents;the third class contains two walnut varieties,with the highest water content and least oil content;whereas,the second class contains 15 walnut varieties,with both water and oil contents at medium levels.The results showed that LFNMR led to a rapid detection of moisture and oil contents in walnuts,while cluster analysis classified different walnuts varieties based on these parameters.This study also provided the basis for optimizing the storage methods and storage conditions of walnuts.
文摘This article introduces the solid acid catalyst for isobutene/butylenes alkylation, the HTS Ti/Si zeolite for ammonoxidation of cyclohexanone and the noncrystalline alloy catalyst and magnetically stabi- lized bed for hydrofining of caprolactam that were developed recently by SINOPEC Research Institute of Petroleum Processing (RIPP).