期刊文献+
共找到494,172篇文章
< 1 2 250 >
每页显示 20 50 100
Giant Magneto-Impedance Effect in Fe_(96-x)B_4 (x=7 or 10) Nanocrystalline Ribbons 被引量:1
1
作者 Zhichao LU and Wei HAN (National Amorphous and Nanocrystalline Alloy Engineering Research Center, Center Iron and Steel Research Institute, Beijing 100081, China) Deren LI (Department of Physics, Northeastern University, Shenyang 110006, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期148-150,共3页
The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples e... The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples exist the optimum annealing temperature and optimum frequency at which the relative change in ribbon voltage is strongest, and the sensitivity of the magnetic response of the annealed Fe_89Zr_7B_4 ribbon is two order of magnitude larger than that of the annealed Fe_86Zr_10 B4 ribbon. The effect of magnetic properties and structural characteristics on giant magneto-impedance was discussed. 展开更多
关键词 Giant magneto-impedance effect in Fe x=7 or 10 x)B4 X Nanocrystalline Ribbons GMI
下载PDF
Giant Magneto-Impedance Effect in Amorphous and Current Annealed Fe73.5Cu1Nb3Si13.5B9 Wire 被引量:4
2
作者 HAN Wei LI De-ren +1 位作者 LU Zhi-chao ZHOU Shao-xiong 《Journal of Iron and Steel Research International》 SCIE EI CAS CSCD 2002年第1期55-57,共3页
The magneto-impedance(MI) effect in amorphous and current annealed Fe_(73.5)Cu_1Nb_3Si_(13.5)B_9 wires has been measured to investigate the influence of DC annealing,highcurrent-density electropulsing annealing and te... The magneto-impedance(MI) effect in amorphous and current annealed Fe_(73.5)Cu_1Nb_3Si_(13.5)B_9 wires has been measured to investigate the influence of DC annealing,highcurrent-density electropulsing annealing and tensile stress applied during annealing process.The results showed that the MI of DC annealed sample exhibits a sharp maximum.The Maximum MI ratio of 60%was observed in the sample of high-current-density electropulsing annealed under applied tensile stress. 展开更多
关键词 amorphous wire DC annealing electropulsing annealing high current density magneto-impedance
下载PDF
Giant Magneto-impedance Effect in Composite Wires with Different Core Layer 被引量:1
3
作者 R.L.Wang X.Li +3 位作者 X.H.Kong Y.X.Guo J.Z.Ruan Z.J.Zhao 《Nano-Micro Letters》 SCIE EI CAS 2013年第2期140-144,共5页
Composite structure materials were potential sensing elements for magnetic sensors due to Giant magnetoimpedance(GMI) effect. Two kinds of composite wires with different magnetic/non-magnetic structures were fabricate... Composite structure materials were potential sensing elements for magnetic sensors due to Giant magnetoimpedance(GMI) effect. Two kinds of composite wires with different magnetic/non-magnetic structures were fabricated by using electroless deposition methods and the magnetoimpedance properties were investigated. The maximum GMI ratio of 114% was acquired at 60 MHz in the composite wires with a ferromagnetic core, whereas, 116% of maximum GMI ratio was found in the composite wires with a conductive core at low frequency of 600 k Hz. These results exhibit that the GMI ratio reaches the maximum when magnetoresistance ratio ?R/R and magnetoinductance ratio ?X/X make the comparative contributions to the total magnetoimpedance(MI). The obvious GMI effect obtained in the composite wires with conductive core frequency may provide a candidate for applications in magnetic sensors, especially at low frequencies. 展开更多
关键词 Composite wires Electroless deposition Giant Magnetoimpedance effect RESISTIVITY
下载PDF
Giant magneto-impedance effects in nanocrystalline soft magnetic alloy ribbons 被引量:5
4
作者 Ku, WJ Ge, FD +2 位作者 Yan, G Wang, XY Zhu, J 《Chinese Science Bulletin》 SCIE EI CAS 1997年第12期1049-1052,共4页
SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potentia... SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potential applications in industry. Amorphous (and nanocrys-talline) soft magnetic alloys have very large magnetic permeability, when an ac driving currentand an external magnetic field (EMF) are applied, the EMF will damp the magnetic fluxchange caused by the ac driving current, thus the magnetic permeability will decrease; as a re- 展开更多
关键词 GIANT magneto-impedance effects (GMI) MAGNETIC permeability penetration depth NANOCRYSTALLINE soft MAGNETIC alloy ribbon.
原文传递
Magneto-impedance effect in soft Fe-based nanocrystalline alloys 被引量:1
5
作者 Yang, JX Yang, XL +3 位作者 Chen, GO Hu, BY Shen, GT Jiang, KY 《Chinese Science Bulletin》 SCIE EI CAS 1997年第3期196-199,共4页
IN recent years, giant magneto-resistance (GMR) effects have been observed in some binary composite systems such as multi-layered and granular films of Fe, Co, Ni and Cr, Ag, Cu and attracted considerable interest due... IN recent years, giant magneto-resistance (GMR) effects have been observed in some binary composite systems such as multi-layered and granular films of Fe, Co, Ni and Cr, Ag, Cu and attracted considerable interest due to their potential applications in magnetic recording heads and field sensors. However, a notable GMR effect in these films always requires a strong external magnetic field at low temperature. More recently, Mohri et al. have discovered 展开更多
关键词 FE-BASED NANOCRYSTALLINE GIANT magneto-impedance effect TRANSVERSE magnetic field annealing.
原文传递
Design and Fabrication of Magnetic Sensor Based on Giant Magneto-Impedance Effect 被引量:1
6
作者 Guo Kai, Wang Sansheng, Yang Hui, Chu Xianghua, Xu Yan Beihang University, Beijing 100191, China 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2011年第S3期315-318,共4页
A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-imp... A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-impedance ratio is 475% and magnetic sensitivity of about 120%/Oe (1 Oe=80 A/m) at 20MHz, which is helpful to improve the sensitivity of magnetic sensor. The performances of the sensor were carefully studied in open-loop and closed-loop with negative feedback. The full measurement range of the magnetic field detection is 1.7-4 Oe presently, and the sensitivity achieves 176 mV/Oe. The sensor with negative feedback shows excellent linearity and good stability. The designed magnetic sensor can be applied in geomagnetic field measurement. 展开更多
关键词 MAGNETIC sensor GIANT magneto-impedance MAGNETIC field-annealing sensitivity
原文传递
Magnetic properties and giant magneto-impedance effect study of Fe-based nanocry-stalline powder 被引量:1
7
作者 ZHAO Zhenjie F.Bendjaballah +3 位作者 JIANG Keyu RUAN Jianzhong YANG Xielong YANG Deping 《Chinese Science Bulletin》 SCIE EI CAS 2002年第2期102-104,共3页
The macroscopic and microscopic magnetic properties for amorphous and nanocrystalline Fe73.5Cu1Nb3-Si13.5B9 powder have been investigated and their giant mag-neto-impedance (GMI) effect is reported for the first time.... The macroscopic and microscopic magnetic properties for amorphous and nanocrystalline Fe73.5Cu1Nb3-Si13.5B9 powder have been investigated and their giant mag-neto-impedance (GMI) effect is reported for the first time. The experimental results show that powder sample annealed at 510℃ possesses the optimum soft magnetic properties. However, the maximum longitudinally driven GMI (LDGMI) ratio (about 52%) is found in the sample annealed at 600℃. This means that the LDGMI ratio depends on not only their magnetic properties but also their electric properties. 展开更多
关键词 NANOCRYSTALLINE GMI effect Mossbauer spectroscopy
原文传递
Giant magneto-impedance effect of two paralleled amorphous microwires
8
作者 Shu-Ling Zhang Yue-Sheng Chai +3 位作者 Da-Qing Fang Lu-Cai Wang Da-Wei Xing Jian-Fei Sun 《Rare Metals》 SCIE EI CAS CSCD 2016年第4期344-348,共5页
Giant magneto-impedance (GMI) is effectively enhanced by the mutual magnetic interaction between two amorphous microwires. A comparative study on GMI properties of a single wire and two wires arranged in par- allel ... Giant magneto-impedance (GMI) is effectively enhanced by the mutual magnetic interaction between two amorphous microwires. A comparative study on GMI properties of a single wire and two wires arranged in par- allel mode was reported in this work. Two-peak (TP) of impedance characteristic is presented when the dc external field changed from 0 to 320 A,m-' in two-wire system, which is attributed to successive magnetization process in two wires induced by their magnetic interaction. And the evolution of single peak to TP phenomenon, when the distance between two wires is upto 8 ram, evidences a distance dependence of transformation from successive magnetization to simultaneous via a corresponding dis- tance dependence of magnetostatic interactions. It is pro- posed that the recombination of magnetic interaction and the shielding effect results in a distance dependency of GMI response. When the distance is 8 ram, the magneti- zation process is close to synchronous between two wires, which give rises to higher circular permeability and better GMI response. The impedance ratio AZ/Z increases from 74.5 % of single wire to 172.4 % at 10 MHz. However, when the distance is upto 12 mm, the magnetic interaction is weak and magnetization process is completely independent, and GMI response decreases, relatively. This indicates that the GMI response could be effectively improved in a two-wire connection with an optical distance, which is promising and useful for the application of high-performance GMI sensors. 展开更多
关键词 Amorphous microwire Magnetic interaction Giant magneto-impedance MAGNETIZATION
原文传递
Locally Enhanced Flow and Electric Fields Through a Tip Effect for Efficient Flow‑Electrode Capacitive Deionization
9
作者 Ziquan Wang Xiangfeng Chen +5 位作者 Yuan Zhang Jie Ma Zhiqun Lin Amor Abdelkader Maria‑Magdalena Titirici Libo Deng 《Nano-Micro Letters》 SCIE EI CAS 2025年第2期1-17,共17页
Low-electrode capacitive deionization(FCDI)is an emerging desalination technology with great potential for removal and/or recycling ions from a range of waters.However,it still suffers from inefficient charge transfer... Low-electrode capacitive deionization(FCDI)is an emerging desalination technology with great potential for removal and/or recycling ions from a range of waters.However,it still suffers from inefficient charge transfer and ion transport kinetics due to weak turbulence and low electric intensity in flow electrodes,both restricted by the current collectors.Herein,a new tip-array current collector(designated as T-CC)was developed to replace the conventional planar current collectors,which intensifies both the charge transfer and ion transport significantly.The effects of tip arrays on flow and electric fields were studied by both computational simulations and electrochemical impedance spectroscopy,which revealed the reduction of ion transport barrier,charge transport barrier and internal resistance.With the voltage increased from 1.0 to 1.5 and 2.0 V,the T-CC-based FCDI system(T-FCDI)exhibited average salt removal rates(ASRR)of 0.18,0.50,and 0.89μmol cm^(-2) min^(-1),respectively,which are 1.82,2.65,and 2.48 folds higher than that of the conventional serpentine current collectors,and 1.48,1.67,and 1.49 folds higher than that of the planar current collectors.Meanwhile,with the solid content in flow electrodes increased from 1 to 5 wt%,the ASRR for T-FCDI increased from 0.29 to 0.50μmol cm^(-2) min^(-1),which are 1.70 and 1.67 folds higher than that of the planar current collectors.Additionally,a salt removal efficiency of 99.89%was achieved with T-FCDI and the charge efficiency remained above 95%after 24 h of operation,thus showing its superior long-term stability. 展开更多
关键词 Flow-electrode Capacitive deionization Current collector Tip effect DESALINATION
下载PDF
Late effects of the treatment of childhood cancer
10
作者 Jelena Roganovic 《World Journal of Clinical Cases》 SCIE 2025年第7期6-12,共7页
Excellent progress has been made in the last few decades in the cure rates of pediatric malignancies,with more than 80%of children with cancer who have access to contemporary treatment being cured.However,the therapie... Excellent progress has been made in the last few decades in the cure rates of pediatric malignancies,with more than 80%of children with cancer who have access to contemporary treatment being cured.However,the therapies responsible for this survival can also produce adverse physical and psychological long-term outcomes,referred to as late effects,which appear months to years after the completion of cancer treatment.Research has shown that 60%to 90%of childhood cancer survivors(CCSs)develop one or more chronic health conditions,and 20%to 80%of survivors experience severe or life-threatening complications during adulthood.Therefore,understanding the late side effects of such treatments is important to improve the health and quality of life of the growing population of CCSs. 展开更多
关键词 SURVIVORSHIP CANCER CHILDREN TREATMENT Late effects
下载PDF
Wafer‑Scale Vertical 1D GaN Nanorods/2D MoS_(2)/PEDOT:PSS for Piezophototronic Effect‑Enhanced Self‑Powered Flexible Photodetectors
11
作者 Xin Tang Hongsheng Jiang +3 位作者 Zhengliang Lin Xuan Wang Wenliang Wang Guoqiang Li 《Nano-Micro Letters》 SCIE EI CAS 2025年第3期102-116,共15页
van der Waals(vdW)heterostructures constructed by lowdimensional(0D,1D,and 2D)materials are emerging as one of the most appealing systems in next-generation flexible photodetection.Currently,hand-stacked vdW-type phot... van der Waals(vdW)heterostructures constructed by lowdimensional(0D,1D,and 2D)materials are emerging as one of the most appealing systems in next-generation flexible photodetection.Currently,hand-stacked vdW-type photodetectors are not compatible with large-areaarray fabrication and show unimpressive performance in self-powered mode.Herein,vertical 1D GaN nanorods arrays(NRAs)/2D MoS_(2)/PEDOT:PSS in wafer scale have been proposed for self-powered flexible photodetectors arrays firstly.The as-integrated device without external bias under weak UV illumination exhibits a competitive responsivity of 1.47 A W^(−1)and a high detectivity of 1.2×10^(11)Jones,as well as a fast response speed of 54/71μs,thanks to the strong light absorption of GaN NRAs and the efficient photogenerated carrier separation in type-II heterojunction.Notably,the strain-tunable photodetection performances of device have been demonstrated.Impressively,the device at−0.78%strain and zero bias reveals a significantly enhanced photoresponse with a responsivity of 2.47 A W^(−1),a detectivity of 2.6×10^(11)Jones,and response times of 40/45μs,which are superior to the state-of-the-art self-powered flexible photodetectors.This work presents a valuable avenue to prepare tunable vdWs heterostructures for self-powered flexible photodetection,which performs well in flexible sensors. 展开更多
关键词 Vertical nanorod arrays van der Waals heterostructure Piezophototronic effect Self-powered photodetection Flexible sensors
下载PDF
Novel Methodologies for Preventing Crack Propagation in Steel Gas Pipelines Considering the Temperature Effect
12
作者 Nurlan Zhangabay Ulzhan Ibraimova +4 位作者 Marco Bonopera Ulanbator Suleimenov Konstantin Avramov Maryna Chernobryvko Aigerim Yessengali 《Structural Durability & Health Monitoring》 EI 2025年第1期1-23,共23页
Using the software ANSYS-19.2/Explicit Dynamics,this study performedfinite-element modeling of the large-diameter steel pipeline cross-section for the Beineu-Bozoy-Shymkent gas pipeline with a non-through straight crac... Using the software ANSYS-19.2/Explicit Dynamics,this study performedfinite-element modeling of the large-diameter steel pipeline cross-section for the Beineu-Bozoy-Shymkent gas pipeline with a non-through straight crack,strengthened by steel wire wrapping.The effects of the thread tensile force of the steel winding in the form of single rings at the crack edges and the wires with different winding diameters and pitches were also studied.The results showed that the strengthening was preferably executed at a minimum value of the thread tensile force,which was 6.4%more effective than that at its maximum value.The analysis of the influence of the winding dia-meters showed that the equivalent stresses increased by 32%from the beginning of the crack growth until the wire broke.The increment in winding diameter decelerated the disclosure of the edge crack and reduced its length by 8.2%.The analysis of the influence of the winding pitch showed that decreasing the distance between the winding turns also led to a 33.6%reduction in the length of the straight crack and a 7.9%reduction in the maximum stres-ses on the strengthened pipeline cross-section.The analysis of the temperature effect on the pipeline material,within a range from-40℃ to+50℃,resulted in a crack length change of up to 5.8%.As the temperature dropped,the crack length decreased.Within such a temperature range,the maximum stresses were observed along the cen-tral area of the crack,which were equal to 413 MPa at+50℃ and 440 MPa at-40℃.The results also showed that the presence of the steel winding in the pipeline significantly reduced the length of crack propagation up to 8.4 times,depending on the temperature effect and design parameters of prestressing.This work integrated the existing methods for crack localization along steel gas pipelines. 展开更多
关键词 Crack propagation finite-element internal pressure PRESTRESSING steel gas pipeline temperature effect
下载PDF
Relationship between parenting stress and behavioral and emotional problems in preschool children: A mediation effect analysis
13
作者 Zhi-Wei Fu Yue-Jing Li +3 位作者 Ran Yu Rui-Qing Guo Li-Xia Gao Sheng-Xia Zhao 《World Journal of Psychiatry》 SCIE 2025年第1期128-136,共9页
BACKGROUND Emotional reactions,such as anxiety,irritability,and aggressive behavior,have attracted clinical attention as behavioral and emotional problems in preschool-age children.AIM To investigate the current statu... BACKGROUND Emotional reactions,such as anxiety,irritability,and aggressive behavior,have attracted clinical attention as behavioral and emotional problems in preschool-age children.AIM To investigate the current status of family rearing,parental stress,and behavioral and emotional problems of preschool children and to analyze the mediating effect of the current status of family rearing on parental stress and behavioral/emo-tional problems.METHODS We use convenience sampling to select 258 preschool children in the physical examination center of our hospital from October 2021 to September 2023.The children and their parents were evaluated using a questionnaire survey.Pearson's correlation was used to analyze the correlation between child behavioral and emotional problems and parental stress and family rearing,and the structural equation model was constructed to test the mediating effect.RESULTS The score for behavioral/emotional problems of 258 preschool children was(27.54±3.63),the score for parental stress was(87.64±11.34),and the score for parental family rearing was(31.54±5.24).There was a positive correlation between the behavioral and emotional problems of the children and the“hostile/mandatory”parenting style;meanwhile,showed a negative correlation with the“support/participation”parenting style(all P<0.05).The intermediary effect value between the family upbringing of parents in parental stress and children's behavior problems was 29.89%.CONCLUSION Parental family upbringing has a mediating effect between parental stress and behavioral and emotional problems of children.Despite paying attention to the behavioral and emotional problems of preschool-age children,clinical medical staff should provide correct and reasonable parenting advice to their parents to promote the mental health of preschool-age children. 展开更多
关键词 Preschool children Parenting stress Children's behavioral and emotional problems Family rearing Mediating effect
下载PDF
Variations in quantifying patient reported outcome measures to estimate treatment effect
14
作者 Sathish Muthu Srujun Vadranapu 《World Journal of Methodology》 2025年第2期44-53,共10页
In the practice of healthcare,patient-reported outcomes(PROs)and PRO measures(PROMs)are used as an attempt to observe the changes in complex clinical situations.They guide us in making decisions based on the evidence ... In the practice of healthcare,patient-reported outcomes(PROs)and PRO measures(PROMs)are used as an attempt to observe the changes in complex clinical situations.They guide us in making decisions based on the evidence regarding patient care by recording the change in outcomes for a particular treatment to a given condition and finally to understand whether a patient will benefit from a particular treatment and to quantify the treatment effect.For any PROM to be usable in health care,we need it to be reliable,encapsulating the points of interest with the potential to detect any real change.Using structured outcome measures routinely in clinical practice helps the physician to understand the functional limitation of a patient that would otherwise not be clear in an office interview,and this allows the physician and patient to have a meaningful conver-sation as well as a customized plan for each patient.Having mentioned the rationale and the benefits of PROMs,understanding the quantification process is crucial before embarking on management decisions.A better interpretation of change needs to identify the treatment effect based on clinical relevance for a given condition.There are a multiple set of measurement indices to serve this effect and most of them are used interchangeably without clear demarcation on their differences.This article details the various quantification metrics used to evaluate the treatment effect using PROMs,their limitations and the scope of usage and implementation in clinical practice. 展开更多
关键词 Patient-reported outcome measures Treatment effect Minimal clinical important difference Patient-accepted symptom state Minimum detectable change ORTHOPEDICS
下载PDF
GIANT MAGNETO-IMPEDANCE OF PATTERNED FeSiB/Cu/FeSiB TRI-LAYER FILMS
15
作者 X.H. Mao, Y. Zhou, M.S. Wu and B.C. CaiKey Laboratory for Thin Film and Microfabrication of Ministry of Education, Research Institute of Micro/ Nanometer Science and Technology, Shanghai Jiaotong University, Shanghai 200030, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第5期327-331,共5页
Sensitive magnetic field sensor with good performances can be fabricated utilizing the giant magneto-impedance (GMI) effect of soft magnetic multi-layer thin films. The transverse and longitudinal GMI effect in patter... Sensitive magnetic field sensor with good performances can be fabricated utilizing the giant magneto-impedance (GMI) effect of soft magnetic multi-layer thin films. The transverse and longitudinal GMI effect in patterned FeSiB/Cu/FeSiB tri-layer films with the change of external magnetic field and frequency were studied at the same time. The change of the impedance of the films with the external magnetic fieldand frequency was shown. Comparing the longitudinal and transverse effect, the transverse effect has a larger linear range from zero magnetic field to a quite large magnetic field at all frequencies, and the change still were not saturated until the external magnetic field reached 1.2×104A/m, which illustrated that the films can be utilized to detect larger magnetic fields than now presented GMI sensors. 展开更多
关键词 giant magneto-impedance effect FeSiB/Cu/FeSiB films tri- layer films
下载PDF
240 nm AlGaN-based deep ultraviolet micro-LEDs:size effect versus edge effect 被引量:2
16
作者 Shunpeng Lu Jiangxiao Bai +6 位作者 Hongbo Li Ke Jiang Jianwei Ben Shanli Zhang Zi-Hui Zhang Xiaojuan Sun Dabing Li 《Journal of Semiconductors》 EI CAS CSCD 2024年第1期55-62,共8页
240 nm AlGaN-based micro-LEDs with different sizes are designed and fabricated.Then,the external quantum efficiency(EQE)and light extraction efficiency(LEE)are systematically investigated by comparing size and edge ef... 240 nm AlGaN-based micro-LEDs with different sizes are designed and fabricated.Then,the external quantum efficiency(EQE)and light extraction efficiency(LEE)are systematically investigated by comparing size and edge effects.Here,it is revealed that the peak optical output power increases by 81.83%with the size shrinking from 50.0 to 25.0μm.Thereinto,the LEE increases by 26.21%and the LEE enhancement mainly comes from the sidewall light extraction.Most notably,transversemagnetic(TM)mode light intensifies faster as the size shrinks due to the tilted mesa side-wall and Al reflector design.However,when it turns to 12.5μm sized micro-LEDs,the output power is lower than 25.0μm sized ones.The underlying mechanism is that even though protected by SiO2 passivation,the edge effect which leads to current leakage and Shockley-Read-Hall(SRH)recombination deteriorates rapidly with the size further shrinking.Moreover,the ratio of the p-contact area to mesa area is much lower,which deteriorates the p-type current spreading at the mesa edge.These findings show a role of thumb for the design of high efficiency micro-LEDs with wavelength below 250 nm,which will pave the way for wide applications of deep ultraviolet(DUV)micro-LEDs. 展开更多
关键词 ALGAN deep ultraviolet micro-LEDs light extraction efficiency size effect edge effect
下载PDF
Engineering Strategies for Suppressing the Shuttle Effect in Lithium–Sulfur Batteries 被引量:3
17
作者 Jiayi Li Li Gao +7 位作者 Fengying Pan Cheng Gong Limeng Sun Hong Gao Jinqiang Zhang Yufei Zhao Guoxiu Wang Hao Liu 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第1期187-221,共35页
Lithium–sulfur(Li–S)batteries are supposed to be one of the most potential next-generation batteries owing to their high theoretical capacity and low cost.Nevertheless,the shuttle effect of firm multi-step two-elect... Lithium–sulfur(Li–S)batteries are supposed to be one of the most potential next-generation batteries owing to their high theoretical capacity and low cost.Nevertheless,the shuttle effect of firm multi-step two-electron reaction between sulfur and lithium in liquid electrolyte makes the capacity much smaller than the theoretical value.Many methods were proposed for inhibiting the shuttle effect of polysulfide,improving corresponding redox kinetics and enhancing the integral performance of Li–S batteries.Here,we will comprehensively and systematically summarize the strategies for inhibiting the shuttle effect from all components of Li–S batteries.First,the electrochemical principles/mechanism and origin of the shuttle effect are described in detail.Moreover,the efficient strategies,including boosting the sulfur conversion rate of sulfur,confining sulfur or lithium polysulfides(LPS)within cathode host,confining LPS in the shield layer,and preventing LPS from contacting the anode,will be discussed to suppress the shuttle effect.Then,recent advances in inhibition of shuttle effect in cathode,electrolyte,separator,and anode with the aforementioned strategies have been summarized to direct the further design of efficient materials for Li–S batteries.Finally,we present prospects for inhibition of the LPS shuttle and potential development directions in Li–S batteries. 展开更多
关键词 Shuttle effect Designed strategies Li-S battery Lithium polysulfides
下载PDF
THEORETICAL STUDY OF GIANT MAGNETO-IMPEDANCE IN AMORPHOUS FILMS WITH LONGITUDINAL MAGNETIC ANISOTROPY
18
作者 Yu, J.Q. Zhou, Y. +1 位作者 Cai, B.C. Zhao, X.L. 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2000年第4期995-1000,共6页
Giant magneto-impedance (MI) effect in thin films with longitudinal magnetic anisotropy was studied theoretically. The effective permeability of films as a function of external magnetic field Ha, anisotropy field and ... Giant magneto-impedance (MI) effect in thin films with longitudinal magnetic anisotropy was studied theoretically. The effective permeability of films as a function of external magnetic field Ha, anisotropy field and other parameters of films was presented by Landau-Lifshitz-Gilbert theory. The theoretical results agree well with the experimental data, which shows a strong dependence of the impedance on the applied magnetic field. 展开更多
关键词 Electric currents Magnetic anisotropy Magnetic fields Skin effect
下载PDF
Giant magneto-impedance and permeability in Fe_(89)Zr_6Hf_1B_4 ribbons
19
作者 YUXiaojun HUJifan +3 位作者 LIBo QINHongwei WANGDonglin LIWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期174-177,共4页
The giant magneto-impedance (GMI) effect associated with the variation of transverse permeability for the ribbons Fe89Zr6Hf1B4 with different annealing temperatures T-A = 793, 823, 893, 923, 993, and 1033 K was invest... The giant magneto-impedance (GMI) effect associated with the variation of transverse permeability for the ribbons Fe89Zr6Hf1B4 with different annealing temperatures T-A = 793, 823, 893, 923, 993, and 1033 K was investigated. There is an optimum annealing temperature TA = 993 K for obtaining the largest GMI effect for the ribbons Fe89Zr6Hf1B4. The magneto-impedance GMI (Z) = (Z(H) - Z(0))/Z(0) for the ribbon with T-A = 993 K can reach -55.09% at a frequency f = 900 kHz under H = 7162 A/m. The relative changes of the real part of transverse permeability Delta mu'/mu'(0) = (mu'(H)- mu'(0))/mu'(0) under H = 7162 A center dot m(-1) at f = 1 MHz are -78.83%, -89.98% and -94.77 % for Fe89Zr6Hf1B4 ribbons with T-A = 823, 893, and 993 K, respectively. The strong GMI effect is accompanied by the large change of transverse permeability. A large magnetoreaetance GMI(X) = (X (H) - X (0))/X (0) of -81.09% can be obtained at f = 100 kHz under H = 7162 A/m for the ribbon with T-A = 993 K. Meanwhile, this present result gave an experimental support to the previous concept / assumption that the positive peak in the field dependence of magneto-impedance is connected to the peak of transverse permeability with varying fields. 展开更多
关键词 giant magneto-impedance PERMEABILITY Fe89Zr6Hf1B4 ribbons annealing temperature
下载PDF
Giant magneto-impedance sensor with working point selfadaptation for unshielded human bio-magnetic detection 被引量:1
20
作者 Changlin HAN Ming XU +2 位作者 Jingsheng TANG Yadong LIU Zongtan ZHOU 《Virtual Reality & Intelligent Hardware》 EI 2022年第1期38-54,共17页
Background Compared with traditional biomagnetic field detection devices,such as superconducting quantum interference devices(SQUIDs)and atomic magnetometers,only giant magneto impedance(GMI)sensors can be applied for... Background Compared with traditional biomagnetic field detection devices,such as superconducting quantum interference devices(SQUIDs)and atomic magnetometers,only giant magneto impedance(GMI)sensors can be applied for unshielded human brain biomagnetic detection,and they have the potential for application in next-generation wearable equipment for brain-computer interfaces(BCIs).Achieving a better GMI sensor without magnetic shielding requires the stimulation of the GMI effect to be maximized and environmental noise interference to be minimized.Moreover,the GMI effect stimulated in an amorphous filament is closely related to its working point,which is sensitive to both the external magnetic field and the drive current of the filament.Methods In this paper,we propose a new noise reducing GMI gradiometer with a dual-loop self-adapting structure.Noise reduction is realized by a direction-flexible differential probe,and the dual-loop structure optimizes and stabilizes the working point by automatically controlling the external magnetic field and drive current.This dual-loop structure is fully program controlled by a micro control unit(MCU),which not only simplifies the traditional constant parameter sensor circuit,saving the time required to adjust the circuit component parameters,but also improves the sensor performance and environmental adaptation.Results In the performance test,within 2 min of self-adaptation,our sensor showed a better sensitivity and signal-to-noise ratio(SNR)than those of the traditional designs and achieved a background noise of 12 pT/√Hz at 10 Hz and 7pT/√Hz at 200 Hz.Conclusion To the best of our knowledge,our sensor is the first to realize self-adaptation of both the external magnetic field and the drive current. 展开更多
关键词 Brain-computer interface Biomagnetic detection GMI effect Working point self-adaptation Dual-loop control Magnetic gradiometer Differential noise reduction
下载PDF
上一页 1 2 250 下一页 到第