期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Flow Injection Semi-online Preconcentration Graphite Furnace Atomic Absorption Spectrometry for Determination of Cadmium,Copper and Manganese 被引量:3
1
作者 ZHANG Yi-hua, WANG Mei-jia, SU Xing-guang, ZHENG Tao, ZHANG Han-qi and JIN Qin-han Department of Chemistry, Jilin University, Changchun 130023, P. R. ChinaCHEN YingJilin Environmental Monitoring Centre, Changchun 130011, P. R. China 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2002年第1期1-7,共7页
A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements... A micro-flow injection sorbent extraction preconcentration system was combined with a graphite furnace atomic absorption spectrometry that formed an integrated system for the determination of trace amounts of elements. The analytical performances of the prospsed method for determining Cd, Cu and Mn were studied. The analytes were preconcentrated with a thiol resin(Type 190, produced by Nankai University, China) whose active group is -SH. The elements to be determined were preconcentrated onto the column for 60 s and then rinsed with deionized water and eluted with 30 μL of 1 mol/L HCl. The graphite furnace atomic absorption spectrometry(GFAAS) determination of the concentrated analyte was carried out in parallel with the next preconcentration cycle. Enrichment factors 41, 22 and 20 and detection limits(3 σ , n =10) 0.36, 3.8 and 7.0 ng/L for Cd, Cu and Mn, respectively, along with a sampling frequency of 20 h -1 , were obtained with a 60 s loading time at a sample flow rate of 3.5 mL/min. The analytical results for a number of water samples show that the flow-injection semi-online column preconcentration can not only eliminate the effect of some concomitant elements, such as Li, Na, K, Ca and Mg, on the determination of the analyte, but also enhance the sensitivity. 展开更多
关键词 FLOW-INJECTION Semi-online preconcentration atomic absorption spectrometry Cadmium Copper manganese
下载PDF
Appended corrole manganese complexes:Catalysis and axial-ligand effect 被引量:3
2
作者 Nga-Chun Ng Mian HR Mahmood +3 位作者 Chi-K.Chang Hai-Yang Liu Fei Yam Lam-Lung Yeung 《Chinese Chemical Letters》 SCIE CAS CSCD 2014年第4期571-574,共4页
A series of N-base appended corroles and their manganese complexes were synthesized and their binding constants with three different nitrogenous ligands, triethylamine, N-methylimidazole and pyridine, were evaluated b... A series of N-base appended corroles and their manganese complexes were synthesized and their binding constants with three different nitrogenous ligands, triethylamine, N-methylimidazole and pyridine, were evaluated by spectroscopy. Kinetic studies indicated that the presence of appended N- donor ligands may cause a significant enhancement of the rate of oxygen atom transfers (OAT) from (oxo)manganese(V) corrole to alkene, and the stronger axial ligand binding has impact on the rate of the oxidation reaction. Turnover frequency (TOF) for the catalytic oxidation of alkenes by appended manganese corroles varies with the following ligand order: acetamido 〈 pyridyl 〈 imidazolyl. The influence of the external axial ligands on the catalytic epoxidation was investigated by using appended acetamido manganese corrole as catalyst, with the results revealing that N-methylimidazole gave the best enhancement on the yields of total oxidation products among the investigated nitrogenous ligands. 展开更多
关键词 manganese Corrole Catalysis Axial-ligand Oxygen atom transfer
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部