期刊文献+
共找到11篇文章
< 1 >
每页显示 20 50 100
The contribution of steel wallposts to out-of-plane behavior of non-structural masonry walls
1
作者 Fooad Karimi Ghaleh Jough 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第1期243-262,共20页
For years,non-structural masonry walls have received little attention by code developers and professional engineers.Recently,significant efforts have been made to shed more light on out-of-plane(OOP)behavior of non-st... For years,non-structural masonry walls have received little attention by code developers and professional engineers.Recently,significant efforts have been made to shed more light on out-of-plane(OOP)behavior of non-structural masonry walls.In updated provisions of the Iranian seismic code,bed joint reinforcements(BJRs)and steel wallposts have been suggested for use.BJRs are horizontal reinforcements;steel wallposts are vertical truss-like elements intended to provide additional OOP restraints for a wall.The contribution of BJRs has previously been investigated by the authors.This study is devoted to investigating the contribution of steel wallposts to the OOP behavior of non-structural masonry walls.Using pre-validated 3D finite element(FE)models,the OOP behavior of 180 non-structural masonry walls with varying configurations and details are investigated.The OOP pressure-displacement curve,ultimate strength,the response modification factor,and the cracking pattern are among the results presented in this study.It is found that steel wallposts,especially those with higher rigidity,can improve the OOP strength of the walls.The contribution of wallposts in the case of shorter length walls and walls with an opening are more pronounced.Results also indicate that masonry walls with wallpost generally have smaller modification factors compared to similar walls without wallpost. 展开更多
关键词 masonry wall wallpost wind post bed joint reinforcement non-structural masonry wall out-of-plane behavior
下载PDF
Numerical simulation on the seismic performance of retrofitted masonry walls based on the combined finite-discrete element method 被引量:1
2
作者 Wu Biye Dai Junwu +2 位作者 Jin Huan Bai Wen Chen Bowen 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2023年第3期777-805,共29页
Due to the long construction life,improper design methods,brittle material properties and poor construction techniques,most existing masonry structures do not perform well during earthquakes.The retrofitting method us... Due to the long construction life,improper design methods,brittle material properties and poor construction techniques,most existing masonry structures do not perform well during earthquakes.The retrofitting method using an external steel-meshed mortar layer is widely used to retrofit existing masonry buildings.Assessing the seismic performance of masonry walls reinforced by an external steel-meshed mortar layer reasonably and effectively is a difficult subject in the research field of masonry structures.Based on the combined finite-discrete elements method,the numerical models of retrofitted brick walls with four different masonry mortar strengths by an external mortar layer are established.The shear strength of mortar and the contact between the retrofitted mortar layer and the brick blocks are discussed in detail.The failure patterns and load-displacement curves of the retrofitted brick walls were obtained by applying low cycle reciprocating loads to the numerical model,and the bearing capacity and the failure mechanism of the retrofitted walls were obtained by comparing the failure patterns,ultimate bearing capacity,deformability and other aspects with the tests.This study provides a basis for improving the seismic strengthening design method of masonry structures and helps to better assess the seismic performance of masonry structures after retrofitting. 展开更多
关键词 masonry wall external steel-meshed mortar layer combined finite-discrete element method hysteretic curve ultimate bearing capacity
下载PDF
Experimental Investigation on Flexural Performance of Masonry Walls Reinforced with GFRP 被引量:1
3
作者 刘骥夫 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2007年第1期82-84,共3页
This paper presents the results of a test program for flexure reinforcing characteristics of gless fiber-rein forced polymer(GFRP) sheets bonded to masonry beams. A total of eight specimens subjected to monotonic fo... This paper presents the results of a test program for flexure reinforcing characteristics of gless fiber-rein forced polymer(GFRP) sheets bonded to masonry beams. A total of eight specimens subjected to monotonic four-point bending were tested up to failure. These specimens were constructed with two different bond patterns. Six of these specimens were reinforced by using GFRP sheets prior to testing, and the remaining two were not reinforced. The test results indicate a significant increase in both load-bearing capacity and ductile performance of the reinforced walls over the unreinforced ones. 展开更多
关键词 glass fiber-reinforced polymer (GFRP) REINFORCE masonry wall
下载PDF
Failure criteria of unreinforced masonry walls of rural buildings under the impact of flash floods in mountainous regions
4
作者 SI Guang-wu CHEN Xiao-qing +3 位作者 CHEN Jian-gang ZHAO Wan-yu LI Shuai LI Xiang-ning 《Journal of Mountain Science》 SCIE CSCD 2022年第12期3388-3406,共19页
Damage to rural buildings in mountainous regions caused by flash floods accounts for a significant proportion of economic losses from disasters.The unreinforced masonry(URM)wall is the most vulnerable structural eleme... Damage to rural buildings in mountainous regions caused by flash floods accounts for a significant proportion of economic losses from disasters.The unreinforced masonry(URM)wall is the most vulnerable structural element of rural buildings exposed to flash floods.The failure of a URM wall indicates damage to rural buildings in flash floods.Based on the yield line theory of out-of-plane damage of URM walls and the virtual work method,brittle failure criteria for URM walls under the impact of flash floods were established.According to the field investigation data of the 26 June 2020 flash flood event in Damawu Gully and the corresponding simulation results of FLO-2D,the disaster-causing process was analysed,and the failure criteria were validated.Three building parameters were identified to influence the flood-resistance of URM walls,including the mortar grade,the span-to-height ratio of the wall,and the number of floors of the rural building.The results showed that the cause of the 26June disaster was the diversion of a 50-year flash flood into the residential community on the alluvial fan.The affected buildings were constructed with hollow blocks and lacked flood-resistance reinforcement.The critical failure depth of a URM wall restrained at the top by ring beams(RBs)under hydrostatic load conditions is 1.17 to 1.20 times greater than that of a URM wall without RBs,and the difference is even more pronounced when lowerstrength mortar is used.The flood-resistance of a URM wall constructed with Mb 7.5 mortar and restrained by RBs is almost as strong as that of a URM wall constructed with Mb 20 mortar and without RBs.The span-to-height ratio of a URM wall should not be greater than 1.875 in this case.However,the flood-resistance of a URM wall with RB restraint is almost independent of the span-to-height ratio.The brittle fracture energy of masonry mortar is more crucial to the flood-resistance of 4-edge restrained URM walls if L/Z>1.875.The flood-resistance of the URM wall of the first storey increases linearly with the number of floors.Single-storey rural buildings should be given priority to the use of high-grade masonry mortar and high-density blocks to improve flood-resistance.The failure criteria and the influence laws of building parameters on the flood-resistance of URM walls can provide references for flash flood mitigation and flood-resistance reinforcement of rural buildings in mountainous regions of Southwest China. 展开更多
关键词 Flash flood Rural buildings Unreinforced masonry wall Failure criteria Flood-resistance
下载PDF
Experimental studies on behavior of fully grouted reinforced-concrete masonry shear walls 被引量:3
5
作者 Zhao Yan Wang Fenglai 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2015年第4期743-757,共15页
An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the... An experimental study is conducted on fully grouted reinforced masonry shear walls (RMSWs) made from concrete blocks with a new configuration. Ten RMSWs are tested under reversed cyclic lateral load to investigate the influence of different reinforcements and applied axial stress values on their seismic behavior. The results show that flexural strength increases with the applied axial stress, and shear strength dominated by diagonal cracking increases with both the amount of horizontal reinforcement and applied axial stress. Yield displacement, ductility, and energy dissipation capability can be improved substantially by increasing the amount of horizontal reinforcement. The critical parameters for the walls are derived from the experiment: displacement ductility values corresponding to 15% strength degradation of the walls reach up to 2.6 and 4.5 in the shear and flexure failure modes, respectively; stiffness values of flexure- and shear-dominated walls rapidly degrade to 17%–19% and 48%–57% of initial stiffness at 0.50 D<sub>max</sub> (displacement at peak load). The experiment suggests that RMSWs could be assigned a higher damping ratio (~14%) for collapse prevention design and a lower damping value (~7%) for a fully operational limit state or serviceability limit state. 展开更多
关键词 reinforced-concrete masonry shear wall shear strength DUCTILITY stiffness degradation energy dissipation equivalent viscous damping ratio
下载PDF
Blast response of clay brick masonry unit walls unreinforced and reinforced with polyurea elastomer 被引量:2
6
作者 Gang Wu Chong Ji +4 位作者 Xin Wang Fu-yin Gao Chang-xiao Zhao Yu-jun Liu Gui-li Yang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2022年第4期643-662,共20页
Clay brick masonry unit(CBMU) walls are widely used in building structures,and its damage and protection under explosion loads have been a matter of concern in the field of engineering protection.In this paper,a serie... Clay brick masonry unit(CBMU) walls are widely used in building structures,and its damage and protection under explosion loads have been a matter of concern in the field of engineering protection.In this paper,a series of full-scale experiments of the response characteristics of 24 cm CMBU walls unreinforced and reinforced with polyurea elastomer subjected to blast loading were carried out.Through setting 5.0 kg TNT charges at different stand-off distances,the damage characteristics of masonry walls at different scaled distances were obtained.The reinforcement effect of different polyurea coating thicknesses and methods on the blast resistance performance of masonry walls under single and repeated loads were also explored.Five failure grades were summarized according to the dynamic response features of masonry walls.Based on the stress wave propagation pattern in multi-media composite structures,the internal stress distribution of masonry walls were analyzed,and the division basis of the masonry walls’ failure grades was then quantified.Combined with Scanning Electron Microscope(SEM)images,the deformation characteristics of soft and hard segments of polyurea and effects of detonation products on microstructures were revealed respectively,which provides an important reference for the design and application of polyurea in the blast resistance of clay brick masonry walls. 展开更多
关键词 Clay brick masonry unit wall POLYUREA Blast loading Failure grade Reinforcement mechanism
下载PDF
Performance of masonry enclosure walls:lessons learned from recent earthquakes 被引量:1
7
作者 Romeu Silva Vicente Hugo Rodrigues +2 位作者 Humberto Varum Aníbal Costa Jos António Raimundo Mendes da Silva 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2012年第1期23-34,共12页
This paper discusses the issue of performance requirements and construction criteria for masonry enclosure and infill walls. Vertical building enclosures in European countries are very often constituted by non-load-be... This paper discusses the issue of performance requirements and construction criteria for masonry enclosure and infill walls. Vertical building enclosures in European countries are very often constituted by non-load-bearing masonry walls, using horizontally perforated clay bricks. These walls are generally supported and confined by a reinforced concrete frame structure of columns and beams/slabs. Since these walls are commonly considered to be nonstructural elements and their influence on the structural response is ignored, their consideration in the design of structures as well as their connection to the adjacent structural elements is frequently negligent or insufficiently detailed. As a consequence, nonstructural elements, as for wall enclosures, are relatively sensitive to drift and acceleration demands when buildings are subjected to seismic actions. Many international standards and technical documents stress the need for design acceptability criteria for nonstructural elements, however they do not specifically indicate how to prevent collapse and severe cracking, and how to enhance the overall stability in the case of moderate to high seismic loading. Furthermore, a review of appropriate measures to improve enclosure wall performance and both in-plane and out-of-plane integrity under seismic actions is addressed. 展开更多
关键词 RC structures masonry enclosure walls infill walls IN-PLANE OUT-OF-PLANE CRACKING performanceimprovement
下载PDF
Development of a monitoring and warning system based on optical fiber sensing technology for masonry retaining walls and trees 被引量:1
8
作者 Peichen Wu Daoyuan Tan +4 位作者 Shaoqun Lin Wenbo Chen Jianhua Yin Numan Malik An Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第4期1064-1076,共13页
Hong Kong has a long history of applying masonry retaining walls to provide horizontal platforms and stabilize man-made slopes.Due to the sub-tropical climate,some masonry retaining walls are colonized by trees.Extrem... Hong Kong has a long history of applying masonry retaining walls to provide horizontal platforms and stabilize man-made slopes.Due to the sub-tropical climate,some masonry retaining walls are colonized by trees.Extreme weather,such as typhoons and heavy rains,may cause rupture or root failure of those trees,thus resulting in instability of the retaining walls.A monitoring and warning system for the movement of masonry retaining walls and sway of trees has been designed with the application of fiber Bragg grating(FBG)sensing technology.The monitoring system is also equipped with a solar power system and 4G data transmission devices.The key functions of the proposed monitoring system include remote sensing and data access,early warning,and real-time data visualization.The setups and working principles of the monitoring systems and related transducers are introduced.The feasibility,accuracy,serviceability and reliability of this monitoring system have been checked by in-site calibration tests and four-month monitoring.Besides,a two-level interface has been developed for data visualization.The monitoring results show that the monitored masonry retaining wall had a reversible movement up to 2.5 mm during the monitoring period.Besides,it is found that the locations of the maximum strain on trees depend on the crown spread of trees. 展开更多
关键词 masonry retaining walls TREE Monitoring Fiber Bragg grating(FBG)sensing Warning system
下载PDF
Experimental Study on Properties of Masonry Infill Walls Connected to Steel Frames with Different Connection Details
9
作者 Mehdi Kahrizi Mehrzad TahamouliRoudsari 《Structural Durability & Health Monitoring》 EI 2020年第2期165-185,共21页
The properties of infills and the way they are connected to frames may have significant effects on the seismic behavior of the structure.This study pre-sents an experimental study on evaluation and testing of five sin... The properties of infills and the way they are connected to frames may have significant effects on the seismic behavior of the structure.This study pre-sents an experimental study on evaluation and testing of five single story,single bay samples with the scale 1:3.This study strives to evaluate the behavior of masonry infill walls encased in steel frames,with emphasis on diferent details of the connection of the wall to the frame.Four frames with masonry infills and one frame without infill are experimented on by apply ing lateral load to their upper beams.Different details of the connection between the infill and the frame including anchorless wall within the frame,connecting the frame and the infill using separating vertical angles,steel rebars embedded in the infill wall and also using Added Damping And Siffness(ADAS)elements between the infill and the frame were investigated.The results indicate that the manner in which the infill and the frame are connected not only can significantly affect the crack fomation pattern and the failure modes of the infill wall,it's also alters the stiffness,the strength,the ductility,the out-of-plane deformation,and the amount of energy dis-sipation of the frame.Furthermore,not only using the ADAS yielding damper in the connection between the infill and the frame increases ductility and prevents the load-displacement diagram from plummeting,it also can be used in regions with medium to high relative seismic risk given that it can be replaced after the occurrence of earthquakes. 展开更多
关键词 masonry infll wall steel framne wall-fame connection experimental study
下载PDF
Experimental investigation of engineered geopolymer composite for structural strengthening against blast loads
10
作者 Shan Liu Chunyuan Liu +3 位作者 Yifei Hao Yi Zhang Li Chen Zhan Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第2期496-509,共14页
The recent increase in blast/bombing incidents all over the world has pushed the development of effective strengthening approaches to enhance the blast resistance of existing civil infrastructures.Engineered geopolyme... The recent increase in blast/bombing incidents all over the world has pushed the development of effective strengthening approaches to enhance the blast resistance of existing civil infrastructures.Engineered geopolymer composite(EGC)is a promising material featured by eco-friendly,fast-setting and strain-hardening characteristics for emergent strengthening and construction.However,the fiber optimization for preparing EGC and its protective effect on structural elements under blast scenarios are uncertain.In this study,laboratory tests were firstly conducted to evaluate the effects of fiber types on the properties of EGC in terms of workability,dry shrinkage,and mechanical properties in compression,tension and flexure.The experimental results showed that EGC containing PE fiber exhibited suitable workability,acceptable dry shrinkage and superior mechanical properties compared with other types of fibers.After that,a series of field tests were carried out to evaluate the effectiveness of EGC retrofitting layer on the enhancement of blast performance of typical elements.The tests include autoclaved aerated concrete(AAC)masonry walls subjected to vented gas explosion,reinforced AAC panels subjected to TNT explosion and plain concrete slabs subjected to contact explosion.It was found that EGC could effectively enhance the blast resistance of structural elements in different scenarios.For AAC masonry walls and panels,with the existence of EGC,the integrity of specimens could be maintained,and their deflections and damage were significantly reduced.For plain concrete slabs,the EGC overlay could reduce the diameter and depth of the crater and spallation of specimens. 展开更多
关键词 Engineered geopolymer composites Fiber optimization Strengthening material Blast resistance masonry wall Reinforced AAC panel Plain concrete slab
下载PDF
Mechanical properties characterization of different types of masonry infill walls
11
作者 Andre FURTADO Hugo RODRIGUES +1 位作者 Antonio AREDE Humberto VARUM 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2020年第2期411-434,共24页
It is remarkable,the recent advances concerning the development of numerical modeling frameworks to simulate the infill panels'seismic behavior.However,there is a lack of experimental data of their mechanical prop... It is remarkable,the recent advances concerning the development of numerical modeling frameworks to simulate the infill panels'seismic behavior.However,there is a lack of experimental data of their mechanical properties,which are of full importance to calibrate the numerical models.The primary objective of this paper is to present an extensive experimental campaign of mechanical characterization tests of infill masonry walls made with three different types of masonry units:lightweight vertical hollow concrete blocks and hollow clay bricks.Four different types of experimental tests were carried out,namely:compression strength tests,diagonal tensile strength tests,and flexural strength tests parallel and perpendicular to the horizontal bed joints.A total amount of 80 tests were carried out and are reported in the present paper.The second objective of this study was to compare the mechanical properties of as-built and existing infill walls.The results presented and discussed herein,will be in terms of strain-stress curves and damages observed within the tests.It was observed a fragile behavior in the panels made with hollow clay horizontal bricks,without propagation of cracks.The plaster increased the flexural strength by 57%. 展开更多
关键词 masonry infill walls experimental characterization compression strength shear diagonal strength flexural strength
原文传递
上一页 1 下一页 到第