The characteristics of the mass transfer between powder particles and liquid steel in the Ruhrstahl Heraeus process injection (RH-IJ) refining were simulatively investigated by the use of a 1/4 scale water model of ...The characteristics of the mass transfer between powder particles and liquid steel in the Ruhrstahl Heraeus process injection (RH-IJ) refining were simulatively investigated by the use of a 1/4 scale water model of a 150 t Ruhrstahl Heraeus(RH) degasser. The influences of the lifting gas flow rate, the up-snorkel and down-snorkel inner diameters and the size of powder particles on the characteristics of the mass transfer were examined. The results show that under the condition that the inner diameters of both the up-snorkel and the down-snorkel are the same, the mass transfer coefficient in the liquid,k increases with the increase of the inner diameter of the up-snorkel,the particle size and the lifting gas flow rate (Q1). However, the increase of Q~ should not result in a saturated circulation rate. Under the current working condition,k ranges from 3. 392 × 10 -5 m/s to 2. 661 × 10-4 m/s. On the other hand,with a given lifting gas flow rate and up-snorkel inner diameters ,the mass transfer weakens with the increase of the down-snorkel inner diameter. An inherently nonlinear relationship between the circulation rate (Q~) of molten steel in the RH degasser and k,which increases with the increase of Q1,was found. Under the condition of other parameters being the same,k increases with the increase of the powder particle size. In order to enhance the mass transfer,it is better not to use extremely fine powder.展开更多
Effect of configuration (structure of electrode, interelectrode gap, positions of inlet and outlet, volume of the cell and additional nets) on mass transfer characteristic of a filter-press type electrochemical cell...Effect of configuration (structure of electrode, interelectrode gap, positions of inlet and outlet, volume of the cell and additional nets) on mass transfer characteristic of a filter-press type electrochemical cell has been studied. The mass transfer coefficients on the electrodes were obtained by using the well-known technique based on the determination of limiting diffusion current. It is found that mass transfer coefficients with mesh electrode are greater than that of with plate electrode. Mass transfer coefficient is decreased with interelectrode gap. While interelectrode gap achieved a certain value (7 ram), mass transfer coefficient is steady, no more declining. Mass transfer characteristic for different positions of inlet and outlet are different and dimensionless number groups correlated equations are obtained by experiment. Mass transfer characteristic is the best when inlet located on the top and outlet on the bottom of the cell respectively. While magnified the volume of the cell to eight times, mass transfer characteristic changes little. Mass transfer characteristic without nets is lower than that of with additional nets in the exit region, but higher than that of with additional nets in the entry region.展开更多
Curved microchannels are often encountered in lab-on-chip systems because the effective axial channel lengths of such channels are often larger than those of straight microchannels for a given per unit chip length.In ...Curved microchannels are often encountered in lab-on-chip systems because the effective axial channel lengths of such channels are often larger than those of straight microchannels for a given per unit chip length.In this paper,the effective diffusivity of a neutral solute in an oscillating electromagnetohydrodynamic(EMHD)flow through a curved rectangular microchannel is investigated theoretically.The flow is assumed as a creeping flow due to the extremely low Reynolds number in such microflow systems.Through the theoretical analysis,we find that the effective diffusivity primarily depends on five dimensionless parameters,i.e.,the curvature ratio of the curved channel,the Schmidt number,the tidal displacement,the angular Reynolds number,and the dimensionless electric field strength parameter.Based on the obtained results,we can precisely control the mass transfer characteristics of the EMHD flow in a curved rectangular microchannel by appropriately altering the corresponding parameter values.展开更多
The available studies in the literature on physical modeling of the vacuum circulation (RH, i.e. Ruhrstahl Heraeus) refining process of molten steel have briefly been reviewed. The latest advances made by the author ...The available studies in the literature on physical modeling of the vacuum circulation (RH, i.e. Ruhrstahl Heraeus) refining process of molten steel have briefly been reviewed. The latest advances made by the author with his research group have been summarized. Water modeling was employed to investigate the flow and mixing characteristics of molten steel under the RH and RH KTB (Kawasaki top blowing) conditions and the mass transfer features between molten steel and powder particles in the RH PTB (powder top blowing) refining. The geometric similarity ratio between the model and its prototype (a multifunction RH degasser of 90 t capacity) was 1:5. The effects of the related technological and structural factors were considered. These latest studies have revealed the flow and mixing characteristics of molten steel and the mass transfer features between molten steel and powder particles in these processes, and have provided a better understanding of the refining processes of molten steel.展开更多
In this paper,the structure and characteristics of the NS high-efficiency composite trays based on the doublelayer aperture jet sieve plate and compositely structured packing were investigated.The effect of aperture a...In this paper,the structure and characteristics of the NS high-efficiency composite trays based on the doublelayer aperture jet sieve plate and compositely structured packing were investigated.The effect of aperture and opening ratio of plate on the fluid dynamics of the NS high-efficiency composite trays,such as the dry tray pressure drop,the wet tray pressure drop,the entrainment,the froth height,the leakage and mass transfer characteristics,were investigated.As a result, the low pressure drop,the high efficiency and the high capacity are the main advantages of the NS high-efficiency composite trays compared to other types of trays.According to this study,small aperture is useful for reducing the pressure drop and entrainment with a high mass transfer efficiency;while large aperture can achieve high capacity and efficiency in a broader operating range at the same pressure drop and entrainment.展开更多
文摘The characteristics of the mass transfer between powder particles and liquid steel in the Ruhrstahl Heraeus process injection (RH-IJ) refining were simulatively investigated by the use of a 1/4 scale water model of a 150 t Ruhrstahl Heraeus(RH) degasser. The influences of the lifting gas flow rate, the up-snorkel and down-snorkel inner diameters and the size of powder particles on the characteristics of the mass transfer were examined. The results show that under the condition that the inner diameters of both the up-snorkel and the down-snorkel are the same, the mass transfer coefficient in the liquid,k increases with the increase of the inner diameter of the up-snorkel,the particle size and the lifting gas flow rate (Q1). However, the increase of Q~ should not result in a saturated circulation rate. Under the current working condition,k ranges from 3. 392 × 10 -5 m/s to 2. 661 × 10-4 m/s. On the other hand,with a given lifting gas flow rate and up-snorkel inner diameters ,the mass transfer weakens with the increase of the down-snorkel inner diameter. An inherently nonlinear relationship between the circulation rate (Q~) of molten steel in the RH degasser and k,which increases with the increase of Q1,was found. Under the condition of other parameters being the same,k increases with the increase of the powder particle size. In order to enhance the mass transfer,it is better not to use extremely fine powder.
基金Supported by the National Natural Science Foundation of China (20573045, 20843001), the "Tenth Five-Year" National Key Scientific and Technological Project (2004BA313B-17) and the National High Technology Research and Development Pro gram of China (2006AA06Z321).
文摘Effect of configuration (structure of electrode, interelectrode gap, positions of inlet and outlet, volume of the cell and additional nets) on mass transfer characteristic of a filter-press type electrochemical cell has been studied. The mass transfer coefficients on the electrodes were obtained by using the well-known technique based on the determination of limiting diffusion current. It is found that mass transfer coefficients with mesh electrode are greater than that of with plate electrode. Mass transfer coefficient is decreased with interelectrode gap. While interelectrode gap achieved a certain value (7 ram), mass transfer coefficient is steady, no more declining. Mass transfer characteristic for different positions of inlet and outlet are different and dimensionless number groups correlated equations are obtained by experiment. Mass transfer characteristic is the best when inlet located on the top and outlet on the bottom of the cell respectively. While magnified the volume of the cell to eight times, mass transfer characteristic changes little. Mass transfer characteristic without nets is lower than that of with additional nets in the exit region, but higher than that of with additional nets in the entry region.
基金Project supported by the National Natural Science Foundation of China(No.11772162)the Natural Science Foundation of Inner Mongolia Autonomous Region of China(No.2016MS0106)。
文摘Curved microchannels are often encountered in lab-on-chip systems because the effective axial channel lengths of such channels are often larger than those of straight microchannels for a given per unit chip length.In this paper,the effective diffusivity of a neutral solute in an oscillating electromagnetohydrodynamic(EMHD)flow through a curved rectangular microchannel is investigated theoretically.The flow is assumed as a creeping flow due to the extremely low Reynolds number in such microflow systems.Through the theoretical analysis,we find that the effective diffusivity primarily depends on five dimensionless parameters,i.e.,the curvature ratio of the curved channel,the Schmidt number,the tidal displacement,the angular Reynolds number,and the dimensionless electric field strength parameter.Based on the obtained results,we can precisely control the mass transfer characteristics of the EMHD flow in a curved rectangular microchannel by appropriately altering the corresponding parameter values.
文摘The available studies in the literature on physical modeling of the vacuum circulation (RH, i.e. Ruhrstahl Heraeus) refining process of molten steel have briefly been reviewed. The latest advances made by the author with his research group have been summarized. Water modeling was employed to investigate the flow and mixing characteristics of molten steel under the RH and RH KTB (Kawasaki top blowing) conditions and the mass transfer features between molten steel and powder particles in the RH PTB (powder top blowing) refining. The geometric similarity ratio between the model and its prototype (a multifunction RH degasser of 90 t capacity) was 1:5. The effects of the related technological and structural factors were considered. These latest studies have revealed the flow and mixing characteristics of molten steel and the mass transfer features between molten steel and powder particles in these processes, and have provided a better understanding of the refining processes of molten steel.
基金supported by the Key Project of Chinese National Programs for Fundamental Research and Development(973 Program) (contract number:2005CB221204-5)
文摘In this paper,the structure and characteristics of the NS high-efficiency composite trays based on the doublelayer aperture jet sieve plate and compositely structured packing were investigated.The effect of aperture and opening ratio of plate on the fluid dynamics of the NS high-efficiency composite trays,such as the dry tray pressure drop,the wet tray pressure drop,the entrainment,the froth height,the leakage and mass transfer characteristics,were investigated.As a result, the low pressure drop,the high efficiency and the high capacity are the main advantages of the NS high-efficiency composite trays compared to other types of trays.According to this study,small aperture is useful for reducing the pressure drop and entrainment with a high mass transfer efficiency;while large aperture can achieve high capacity and efficiency in a broader operating range at the same pressure drop and entrainment.