Aqueous Zn batteries are promising candidates for grid-scale renewable energy storage.Foil electrodes have been widely investigated and applied as anode materials for aqueous Zn batteries,however,they suffer from limi...Aqueous Zn batteries are promising candidates for grid-scale renewable energy storage.Foil electrodes have been widely investigated and applied as anode materials for aqueous Zn batteries,however,they suffer from limited surface area and severe interfacial issues including metallic dendrites and corrosion side reactions,limiting the depth of discharge(DOD)of the foil electrode materials.Herein,a low-temperature replacement reaction is utilized to in-situ construct a three-dimensional(3D)corrosion-resistant interface for deeply rechargeable Zn foil electrodes.Specifically,the deliberate low-temperature environment controlled the replacement rate between polycrystalline Zn metal and oxalic acid,producing a Zn foil electrode with distinct 3D corrosion-resistant interface(3DCI-Zn),which differed from conventional two-dimensional(2D)protective structure and showed an order of magnitude higher surface area.Consequently,the 3DCI-Zn electrode exhibited dendrite-free and anticorrosion properties,and achieved stable plating/stripping performance for 1000 h at 10 mA cm^(-2)and 10 mAh cm^(-2)with a remarkable DOD of 79%.After pairing with a MnO2cathode with a high areal capacity of 4.2 mAh cm^(-2),the pouch cells delivered 168 Wh L^(-1)and a capacity retention of 89.7%after 100 cycles with a low negative/positive(N/P)ratio of 3:1.展开更多
Pipeline of oil and gas have an increased risk because of pipeline punctures and rupture caused by corrosion. Therefore it is very important to have a reliable way for pipeline corrosion prediction. The corrosion dept...Pipeline of oil and gas have an increased risk because of pipeline punctures and rupture caused by corrosion. Therefore it is very important to have a reliable way for pipeline corrosion prediction. The corrosion depth prediction models that based on the support vector machines and chaos were introduced in this paper. A real example was given in this paper. The predicted results showed that the prediction models have a more higher precision. The two corrosion depth prediction models are reasonable in corrosion research, which can supply a scientific basis for pipeline safety management, service life prediction and repair.展开更多
Objectives: The effect of ceramics construction (press- able, machinable) and corrosion on flexural strength and micro-hardness was studied. Materials & Methods: Two types of ceramics were tested: IPS e-max Press ...Objectives: The effect of ceramics construction (press- able, machinable) and corrosion on flexural strength and micro-hardness was studied. Materials & Methods: Two types of ceramics were tested: IPS e-max Press and IPS e-max CAD. Forty samples were constructed and divided into 2 groups according to the type of ceramics. Each group was then subdivided into 2 subgroups. Subgroups 1 were not subjected to corrosion while subgroups 2 were subjected to corro-sion test. Finally each subgroup was divided into 2 classes according to the type of test: biaxial flexural strength, micro-hardness. Results: There was a sig-nificant difference between the two tested ceramics as regard weight loss as IPS e-max CAD recorded less weight loss than IPS e-max Press. As regard the flex-ural strength, IPS e-max CAD recorded significant higher strength than IPS e-max Press. Corroded sam- ples recorded significant lower flexural strength than non-corroded samples for the two tested ceramics. As regard the Vickers micro-hardness test, the results showed significant difference between the two tested ceramics. IPS e-max CAD recorded higher mi-cro-hardness values than IPS e-max Press. The results also showed that the corroded samples recorded no significant micro-hardness values than non- corroded samples for the two tested ceramics. Conclusions: IPS e-max CAD recorded less weight loss weight loss after being subjected to corrosion test than IPS e-max Press. The method of fabrication affected the flexural strength µ-hardness of ceramic as machinable ceramic (e-max CAD) recorded significant higher data than pressable ceramic (e-mas Press). Corrosion decreased the flexural strength of both tested ceramics but had no effect on micro- hardness.展开更多
基金financially supported by the National Natural Science Foundation of China (No.22205068,22109144)the“CUG Scholar”Scientific Research Funds at China University of Geosciences (Wuhan) (Project No.2022118)the Fundamental Research Funds for the Central Universities,China University of Geosciences (Wuhan) (No.162301202673)。
文摘Aqueous Zn batteries are promising candidates for grid-scale renewable energy storage.Foil electrodes have been widely investigated and applied as anode materials for aqueous Zn batteries,however,they suffer from limited surface area and severe interfacial issues including metallic dendrites and corrosion side reactions,limiting the depth of discharge(DOD)of the foil electrode materials.Herein,a low-temperature replacement reaction is utilized to in-situ construct a three-dimensional(3D)corrosion-resistant interface for deeply rechargeable Zn foil electrodes.Specifically,the deliberate low-temperature environment controlled the replacement rate between polycrystalline Zn metal and oxalic acid,producing a Zn foil electrode with distinct 3D corrosion-resistant interface(3DCI-Zn),which differed from conventional two-dimensional(2D)protective structure and showed an order of magnitude higher surface area.Consequently,the 3DCI-Zn electrode exhibited dendrite-free and anticorrosion properties,and achieved stable plating/stripping performance for 1000 h at 10 mA cm^(-2)and 10 mAh cm^(-2)with a remarkable DOD of 79%.After pairing with a MnO2cathode with a high areal capacity of 4.2 mAh cm^(-2),the pouch cells delivered 168 Wh L^(-1)and a capacity retention of 89.7%after 100 cycles with a low negative/positive(N/P)ratio of 3:1.
文摘Pipeline of oil and gas have an increased risk because of pipeline punctures and rupture caused by corrosion. Therefore it is very important to have a reliable way for pipeline corrosion prediction. The corrosion depth prediction models that based on the support vector machines and chaos were introduced in this paper. A real example was given in this paper. The predicted results showed that the prediction models have a more higher precision. The two corrosion depth prediction models are reasonable in corrosion research, which can supply a scientific basis for pipeline safety management, service life prediction and repair.
文摘Objectives: The effect of ceramics construction (press- able, machinable) and corrosion on flexural strength and micro-hardness was studied. Materials & Methods: Two types of ceramics were tested: IPS e-max Press and IPS e-max CAD. Forty samples were constructed and divided into 2 groups according to the type of ceramics. Each group was then subdivided into 2 subgroups. Subgroups 1 were not subjected to corrosion while subgroups 2 were subjected to corro-sion test. Finally each subgroup was divided into 2 classes according to the type of test: biaxial flexural strength, micro-hardness. Results: There was a sig-nificant difference between the two tested ceramics as regard weight loss as IPS e-max CAD recorded less weight loss than IPS e-max Press. As regard the flex-ural strength, IPS e-max CAD recorded significant higher strength than IPS e-max Press. Corroded sam- ples recorded significant lower flexural strength than non-corroded samples for the two tested ceramics. As regard the Vickers micro-hardness test, the results showed significant difference between the two tested ceramics. IPS e-max CAD recorded higher mi-cro-hardness values than IPS e-max Press. The results also showed that the corroded samples recorded no significant micro-hardness values than non- corroded samples for the two tested ceramics. Conclusions: IPS e-max CAD recorded less weight loss weight loss after being subjected to corrosion test than IPS e-max Press. The method of fabrication affected the flexural strength µ-hardness of ceramic as machinable ceramic (e-max CAD) recorded significant higher data than pressable ceramic (e-mas Press). Corrosion decreased the flexural strength of both tested ceramics but had no effect on micro- hardness.