In this paper, we describe an improved adaptive partial response maximum likelihood (PRML) method combining modulation code tbr signal waveform modulation multi-level disc. This improved adaptive PRML method employs...In this paper, we describe an improved adaptive partial response maximum likelihood (PRML) method combining modulation code tbr signal waveform modulation multi-level disc. This improved adaptive PRML method employs partial response equalizer and adaptive viterbi detector combining modulation code. Compared with the traditional adaptive PRML detector, the improved PRML detector additionally employs illogical sequence detector and corrector. Illogical sequence detector and corrector can aw)id the appearance of illogical sequences effectively, which do not follow the law of modulation code for signal waveform modulation multi-level disc, and obtain the correct sequences. We implement the improved PRML detector using a DSP and an FPGA chip. The experimental results show good performance. The higher efficient and lower complexity can be obtained by using the improved PRML method than by using the previous PRML method. Meanwhile, resource utilization of the improved PRML detector is not changed, but the bit error rate (BER) is reduced by more than 20%.展开更多
To predict the maximum earthquake response of an SDOF structure with a Maxwell fluid damper or supplemental brace-viscous damper system using the seismic design response spectrum technique,a new approach is presented ...To predict the maximum earthquake response of an SDOF structure with a Maxwell fluid damper or supplemental brace-viscous damper system using the seismic design response spectrum technique,a new approach is presented to determine the first-and second-order equivalent viscous damping and stiffness,the peak responses,and the damper force of the above structure.Based on the fact that the dynamic characteristics of a general linear viscoelastically damped structure are fully determined by its free vibration properties and the relaxation time constants of a Maxwell fluid damper and supplemental brace-viscous damper system in engineering practice are all small,the method of improved multiple time scales and the equivalent criterion in which all free vibration properties are the same are used to obtain the first-and second-order equivalent viscous damping and stiffness of the above structure in closed form.The accuracy of the proposed method is higher and significantly better than that of the modal strain energy method.Furthermore,in the parametric range of the requirements of the Chinese "Code for Seismic Design of Buildings",the error of the proposed second-order equivalent system for the abovementioned engineering structure is not more than 0.5%.展开更多
A novel read channel for signal waveform modulation multi-level disc is presented in this paper. This read channel employs timing recovery system and partial response maximum likelihood detector. Compared to the previ...A novel read channel for signal waveform modulation multi-level disc is presented in this paper. This read channel employs timing recovery system and partial response maximum likelihood detector. Compared to the previous read channel composed of level detection and run-length detection, the present read channel shows superiority in capacity increase and robust performance. Especially, relying on the partial response maximum likelihood detection, lower bit error rate can be obtained.展开更多
Recently, Sandia Laboratories developed a neutron scatter camera to detect special nuclear materials. This camera exhibits the following advantages: high efficiency, direction discrimination, neutron-gamma discriminat...Recently, Sandia Laboratories developed a neutron scatter camera to detect special nuclear materials. This camera exhibits the following advantages: high efficiency, direction discrimination, neutron-gamma discrimination ability, and wide field of view. However, using the direct projection method, the angular resolution of this camera is limited by uncertainties in the energies estimated from pulse height and time of flight measurements. In this study, we established an eight-element neutron scatter camera and conducted the experiment with a ^(252)Cf neutron source. The results show that it has an angular resolution better than 8°(1s) and a detection efficiency of approximately 2.6′10-4. Using maximum likelihood expectation maximization method, the image artifact was eliminated, and the angular resolution was improved. We proposed an average scattering angle method to estimate the scattering energy of neutrons and Compton gamma rays. As such, we can obtain a recognizable image and energy spectrum of the source with some degradation of energy and image resolutions. Finally, a newly measured light response function based on the MPD^(-4) device was used for image reconstruction. Although we did not obtain a better result than that of the standard light response function, we have observed the effects of light response function on image reconstruction.展开更多
基金Project supported by the National Natural Science Foundation of China(Grant No.61127010)
文摘In this paper, we describe an improved adaptive partial response maximum likelihood (PRML) method combining modulation code tbr signal waveform modulation multi-level disc. This improved adaptive PRML method employs partial response equalizer and adaptive viterbi detector combining modulation code. Compared with the traditional adaptive PRML detector, the improved PRML detector additionally employs illogical sequence detector and corrector. Illogical sequence detector and corrector can aw)id the appearance of illogical sequences effectively, which do not follow the law of modulation code for signal waveform modulation multi-level disc, and obtain the correct sequences. We implement the improved PRML detector using a DSP and an FPGA chip. The experimental results show good performance. The higher efficient and lower complexity can be obtained by using the improved PRML method than by using the previous PRML method. Meanwhile, resource utilization of the improved PRML detector is not changed, but the bit error rate (BER) is reduced by more than 20%.
基金National Natural Science Foundation of China under Grant No.51468005 and 51368008Guangxi Natural Science Foundation under Grant No.2014GXNSFAA118315the Innovative Research Team Program of Guangxi University of Science and Technology(2015)
文摘To predict the maximum earthquake response of an SDOF structure with a Maxwell fluid damper or supplemental brace-viscous damper system using the seismic design response spectrum technique,a new approach is presented to determine the first-and second-order equivalent viscous damping and stiffness,the peak responses,and the damper force of the above structure.Based on the fact that the dynamic characteristics of a general linear viscoelastically damped structure are fully determined by its free vibration properties and the relaxation time constants of a Maxwell fluid damper and supplemental brace-viscous damper system in engineering practice are all small,the method of improved multiple time scales and the equivalent criterion in which all free vibration properties are the same are used to obtain the first-and second-order equivalent viscous damping and stiffness of the above structure in closed form.The accuracy of the proposed method is higher and significantly better than that of the modal strain energy method.Furthermore,in the parametric range of the requirements of the Chinese "Code for Seismic Design of Buildings",the error of the proposed second-order equivalent system for the abovementioned engineering structure is not more than 0.5%.
文摘A novel read channel for signal waveform modulation multi-level disc is presented in this paper. This read channel employs timing recovery system and partial response maximum likelihood detector. Compared to the previous read channel composed of level detection and run-length detection, the present read channel shows superiority in capacity increase and robust performance. Especially, relying on the partial response maximum likelihood detection, lower bit error rate can be obtained.
基金supported by the National Natural Science Fundation of China(Grant Nos.1110510611375144&11275153)
文摘Recently, Sandia Laboratories developed a neutron scatter camera to detect special nuclear materials. This camera exhibits the following advantages: high efficiency, direction discrimination, neutron-gamma discrimination ability, and wide field of view. However, using the direct projection method, the angular resolution of this camera is limited by uncertainties in the energies estimated from pulse height and time of flight measurements. In this study, we established an eight-element neutron scatter camera and conducted the experiment with a ^(252)Cf neutron source. The results show that it has an angular resolution better than 8°(1s) and a detection efficiency of approximately 2.6′10-4. Using maximum likelihood expectation maximization method, the image artifact was eliminated, and the angular resolution was improved. We proposed an average scattering angle method to estimate the scattering energy of neutrons and Compton gamma rays. As such, we can obtain a recognizable image and energy spectrum of the source with some degradation of energy and image resolutions. Finally, a newly measured light response function based on the MPD^(-4) device was used for image reconstruction. Although we did not obtain a better result than that of the standard light response function, we have observed the effects of light response function on image reconstruction.