A Combined Antenna Array Deployment with High Positioning Accuracy and Low Angular Measurement Error
1
作者 Wangjie Chen Weiqiang Zhu +3 位作者 Zhenhong Fan Li Wu Yi He Yixiao Wang 《Journal of Beijing Institute of Technology》 EI CAS 2024年第2期141-154,共14页
In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution de... In this paper,an antenna array composed of circular array and orthogonal linear array is proposed by using the design of long and short baseline“orthogonal linear array”and the circular array ambiguity resolution design of multi-group baseline clustering.The effectiveness of the antenna array in this paper is verified by sufficient simulation and experiment.After the system deviation correction work,it is found that in the L/S/C/X frequency bands,the ambiguity resolution probability is high,and the phase difference system error between each channel is basically the same.The angle measurement error is less than 0.5°,and the positioning error is less than 2.5 km.Notably,as the center frequency increases,calibration consistency improves,and the calibration frequency points become applicable over a wider frequency range.At a center frequency of 11.5 GHz,the calibration frequency point bandwidth extends to 1200 MHz.This combined antenna array deployment holds significant promise for a wide range of applications in contemporary wireless communication systems. 展开更多
关键词 antenna array deployment ambiguity resolution phase consistency angle measurement error positioning error
下载PDF
Online Capacitor Voltage Transformer Measurement Error State Evaluation Method Based on In-Phase Relationship and Abnormal Point Detection
2
作者 Yongqi Liu Wei Shi +2 位作者 Jiusong Hu Yantao Zhao Pang Wang 《Smart Grid and Renewable Energy》 2024年第1期34-48,共15页
The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the... The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%. 展开更多
关键词 Capacitor Voltage Transformer measurement error Online Monitoring Principal Component Analysis Local Outlier Factor
下载PDF
Effect of Measurement Error on the Multivariate CUSUM Control Chart for Compositional Data
3
作者 Muhammad Imran Jinsheng Sun +2 位作者 Fatima Sehar Zaidi Zameer Abbas Hafiz Zafar Nazir 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第8期1207-1257,共51页
Control charts(CCs)are one of the main tools in Statistical Process Control that have been widely adopted in manufacturing sectors as an effective strategy for malfunction detection throughout the previous decades.Mea... Control charts(CCs)are one of the main tools in Statistical Process Control that have been widely adopted in manufacturing sectors as an effective strategy for malfunction detection throughout the previous decades.Measurement errors(M.E’s)are involved in the quality characteristic of interest,which can effect the CC’s performance.The authors explored the impact of a linearmodel with additive covariate M.E on the multivariate cumulative sum(CUSUM)CC for a specific kind of data known as compositional data(CoDa).The average run length(ARL)is used to assess the performance of the proposed chart.The results indicate that M.E’s significantly affects themultivariate CUSUM-CoDaCCs.The authors haveused theMarkov chainmethod to study the impact of different involved parameters using six different cases for the variance-covariance matrix(VCM)(i.e.,uncorrelated with equal variances,uncorrelated with unequal variances,positively correlated with equal variances,positively correlated with unequal variances,negatively correlatedwith equal variances and negatively correlated with unequal variances).The authors concluded that the error VCM has a negative impact on the performance of themultivariate CUSUM-CoDa CC,as the ARL increases with an increase in the value of the error VCM.The subgroup size m and powering operator b positively impact the proposed CC,as the ARL decreases with an increase in m or b.The number of variables p also has a negative impact on the performance of the proposed CC,as the values of ARL increase with an increase in p.For the implementation of the proposal,two illustrated examples have been reported formultivariate CUSUM-CoDaCCs inthe presence ofM.E’s.Onedealswith themanufacturingprocessof uncoated aspirin tablets,and the other is based on monitoring the machines involved in the muesli manufacturing process. 展开更多
关键词 MCUSUM chart CODA measurement error manufacturing process PERFORMANCE
下载PDF
Residual lifetime prediction model of nonlinear accelerated degradation data with measurement error 被引量:12
4
作者 Zhongyi Cai Yunxiang Chen +1 位作者 Qiang Zhang Huachun Xiang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2017年第5期1028-1038,共11页
For the product degradation process with random effect (RE), measurement error (ME) and nonlinearity in step-stress accelerated degradation test (SSADT), the nonlinear Wiener based degradation model with RE and ME is ... For the product degradation process with random effect (RE), measurement error (ME) and nonlinearity in step-stress accelerated degradation test (SSADT), the nonlinear Wiener based degradation model with RE and ME is built. An analytical approximation to the probability density function (PDF) of the product's lifetime is derived in a closed form. The process and data of SSADT are analyzed to obtain the relation model of the observed data under each accelerated stress. The likelihood function for the population-based observed data is constructed. The population-based model parameters and its random coefficient prior values are estimated. According to the newly observed data of the target product in SSADT, an analytical approximation to the PDF of its residual lifetime (RL) is derived in accordance with its individual degradation characteristics. The parameter updating method based on Bayesian inference is applied to obtain the posterior value of random coefficient of the RL model. A numerical example by simulation is analyzed to verify the accuracy and advantage of the proposed model. 展开更多
关键词 accelerated degradation test residual lifetime (RL) prediction measurement error random effect NONLINEARITY
下载PDF
Errors and Correction of Precipitation Measurements in China 被引量:8
5
作者 任芝花 黎明琴 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2007年第3期449-458,共10页
In order to discover the range of various errors in Chinese precipitation measurements and seek a correction method, 30 precipitation evaluation stations were set up countrywide before 1993. All the stations are refer... In order to discover the range of various errors in Chinese precipitation measurements and seek a correction method, 30 precipitation evaluation stations were set up countrywide before 1993. All the stations are reference stations in China. To seek a correction method for wind-induced error, a precipitation correction instrument called the "horizontal precipitation gauge" was devised beforehand. Field intercomparison observations regarding 29,000 precipitation events have been conducted using one pit gauge, two elevated operational gauges and one horizontal gauge at the above 30 stations. The range of precipitation measurement errors in China is obtained by analysis of intercomparison measurement results. The distribution of random errors and systematic errors in precipitation measurements are studied in this paper. A correction method, especially for wind-induced errors, is developed. The results prove that a correlation of power function exists between the precipitation amount caught by the horizontal gauge and the absolute difference of observations implemented by the operational gauge and pit gauge. The correlation coefficient is 0.99. For operational observations, precipitation correction can be carried out only by parallel observation with a horizontal precipitation gauge. The precipitation accuracy after correction approaches that of the pit gauge. The correction method developed is simple and feasible. 展开更多
关键词 precipitation evaluation stations intercomparison measurements precipitation measurement errors correction method
下载PDF
WEIGHTED LASSO ESTIMATES FOR SPARSE LOGISTIC REGRESSION:NON-ASYMPTOTIC PROPERTIES WITH MEASUREMENT ERRORS 被引量:2
6
作者 黄华妹 高钰婧 +1 位作者 张慧铭 李波 《Acta Mathematica Scientia》 SCIE CSCD 2021年第1期207-230,共24页
For high-dimensional models with a focus on classification performance,the?1-penalized logistic regression is becoming important and popular.However,the Lasso estimates could be problematic when penalties of different... For high-dimensional models with a focus on classification performance,the?1-penalized logistic regression is becoming important and popular.However,the Lasso estimates could be problematic when penalties of different coefficients are all the same and not related to the data.We propose two types of weighted Lasso estimates,depending upon covariates determined by the Mc Diarmid inequality.Given sample size n and a dimension of covariates p,the finite sample behavior of our proposed method with a diverging number of predictors is illustrated by non-asymptotic oracle inequalities such as the?1-estimation error and the squared prediction error of the unknown parameters.We compare the performance of our method with that of former weighted estimates on simulated data,then apply it to do real data analysis. 展开更多
关键词 logistic regression weighted Lasso oracle inequalities high-dimensional statistics measurement error
下载PDF
Empirical Bayes Test for the Parameter of Rayleigh Distribution with Error of Measurement 被引量:1
7
作者 HUANG JUAN 《Communications in Mathematical Research》 CSCD 2011年第1期17-23,共7页
For the data with error of measurement in historical samples, the empirical Bayes test rule for the parameter of Rayleigh distribution is constructed, and the asymptotically optimal property is obtained. It is shown t... For the data with error of measurement in historical samples, the empirical Bayes test rule for the parameter of Rayleigh distribution is constructed, and the asymptotically optimal property is obtained. It is shown that the convergence rate of the proposed EB test rule can be arbitrarily close to O(n-1/2) under suitable conditions. 展开更多
关键词 error of measurement empirical Bayes asymptotic optimality convergence rate
下载PDF
Parameter-independent error correction for potential measurements by reference electrode in lithium-ion batteries
8
作者 Yalun Li Xinlei Gao +4 位作者 Xuning Feng Xuebing Han Jiuyu Du Languang Lu Minggao Ouyang 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2022年第4期34-45,共12页
The safety monitoring of lithium-ion batteries(LIBs) is of great significance for realizing all-climate and full-lifespan battery management. In-situ measurement of anode potential with implanted reference electrodes(... The safety monitoring of lithium-ion batteries(LIBs) is of great significance for realizing all-climate and full-lifespan battery management. In-situ measurement of anode potential with implanted reference electrodes(REs) has proven to be effective to monitor and avoid the occurrence of severe side reactions like Li plating to ensure the safe and fast charging. However, the intrinsic measurement errors caused by local blocking effects, which also can be referred to as potential artefacts, are seldom taken into consideration in existing studies, yet they highly dominate the correctness of conclusions inferred from REs. In this study, aiming at exploring the physical origin of the measurement errors and ensure reliable potential monitoring, electrochemical and post-mortem tests are conducted using commercial pouch cells with implanted REs. Corresponding electrochemical model which describes the blocking effects, is established to validate the abnormal absence of lithium plating that predicted by measured anode potentials under various charging rates. Theoretical derivation is further presented to explain the error sources, which can be attributed to increased local liquid potential of the RE position. Most importantly, with the guidance of error analysis, a novel parameter-independent error correction method for RE measurements is proposed for the first time, which is proven to be adequate to estimate the real anode potentials and deduce the critical C-rate of Li plating with extra safety margin. After error correction, the resulting critical C-rates are all within the range of 0.55 ± 0.03 C, which is close to the C-rate of 0.6–0.7 C obtained from experiments. In addition, this error correction method can be performed conveniently with only some simple RE measurements of polarization voltages, totally independent of battery electrochemical and geometric parameters. This study provides highly practical error correction method for RE measurements in real LIBs, substantially facilitating the fast diagnosis and safety evaluation of Li plating during charging of LIBs. 展开更多
关键词 Reference electrode Lithium-ion battery Potential artefacts measurement error correction
下载PDF
THE ASYMPTOTIC DISTRIBUTIONS OF EMPIRICAL LIKELIHOOD RATIO STATISTICS IN THE PRESENCE OF MEASUREMENT ERROR
9
作者 伍长春 张润楚 《Acta Mathematica Scientia》 SCIE CSCD 2007年第2期232-242,共11页
Suppose that several different imperfect instruments and one perfect instrument are independently used to measure some characteristics of a population. Thus, measurements of two or more sets of samples with varying ac... Suppose that several different imperfect instruments and one perfect instrument are independently used to measure some characteristics of a population. Thus, measurements of two or more sets of samples with varying accuracies are obtained. Statistical inference should be based on the pooled samples. In this article, the authors also assumes that all the imperfect instruments are unbiased. They consider the problem of combining this information to make statistical tests for parameters more relevant. They define the empirical likelihood ratio functions and obtain their asymptotic distributions in the presence of measurement error. 展开更多
关键词 Empirical likelihood ratio statistics asymptotic distribution measurement error
下载PDF
A Steady-State Errors Correction Method for Eliminating Measurement Errors
10
作者 田新良 杨苹 《Journal of Donghua University(English Edition)》 EI CAS 2013年第4期298-304,共7页
This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In c... This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications. 展开更多
关键词 measurement errors steady-state errors correction(SSEC) active power filters(APF
下载PDF
High Resolution Clinometers for Measurement of Roll Error Motion of a Precision Linear Slide
11
作者 Yuki Shimizu Satoshi Kataoka Wei Gao 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2018年第5期8-16,共9页
This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linea... This paper proposes a new method for measurement of the roll error motion of a slide table in a precision linear slide. The proposed method utilizes a pair of clinometers in the production process of a precision linear slide, where the roll error motion measurement will be carried out repeatedly to confirm whether the surface form errors of slide guideways in the linear slide are su ciently corrected by hand scraping process. In the proposed method, one of the clinometers is mounted on the slide table, while the other is placed on a vibration isolation table, on which the precision linear slide is mounted, so that influences of external disturbances can be cancelled. An experimental setup is built on a vibration isolation table, and some experiments are carried out to verify the feasibility of the proposed method. 展开更多
关键词 Linear slide Clinometer Rotational error motion measurement
下载PDF
Nonparametric Regression Estimation with Mixed Measurement Errors
12
作者 Zanhua Yin Fang Liu Yuanfu Xie 《Applied Mathematics》 2016年第17期2269-2284,共17页
We consider the estimation of nonparametric regression models with predictors being measured with a mixture of Berkson and classical errors. In practice, the Berkson error arises when the variable X of interest is uno... We consider the estimation of nonparametric regression models with predictors being measured with a mixture of Berkson and classical errors. In practice, the Berkson error arises when the variable X of interest is unobservable and only a proxy of X can be measured while the inaccuracy related to the observation of the proxy causes an error of classical type. In this paper, we propose two nonparametric estimators of the regression function in the presence of either or both types of errors. We prove the asymptotic normality of our estimators and derive their rates of convergence. The finite-sample properties of the estimators are investigated through simulation studies. 展开更多
关键词 Berkson error Classical error DECONVOLUTION Kernel Method Mixed measurement errors
下载PDF
Accuracy estimation of site coordinates derived from GNSS-observations by non-classical error theory of measurements
13
作者 Petro Dvulit Stepan Savchuk Iryna Sosonka 《Geodesy and Geodynamics》 CSCD 2021年第5期347-355,共9页
The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of... The velocities of tectonic plates derived from GNSS time series are regularly used as input data for geophysical models. However, as shown by numerous researches, the coordinates time series contain residual errors of a systematic nature, which can significantly affect the reliability of the obtained velocity estimates. This research shows that using non-classical error theory of measurement(NETM)for processing GNSS time series allows detecting the presence of weak, not removed from GNSS processing, sources of systematic errors. Based on the coordinate time series of selected permanent GNSS stations in Europe, we checked the empirical distributions of errors by the NETM on G. Jeffries’ recommendations and on the principles of the theory of hypothesis tests according to Pearson’s criterion. It is established that the obtained coordinates time series of GNSS-stations only partially confirm the hypothesis of their conformity to the normal Gaussian distribution law, and this may be the main reason for their unrepresentative classification. In the future, it is necessary to identify and take into account the causes of residual errors that distort the real distribution of the results of the GNSS time series. 展开更多
关键词 GNSS data Processing GNSS time Series Discontinuities in time series Non-classical error theory of measurements Noise analysis
下载PDF
Analysis and counter measure in blood grouping errors of volunteers’donating blood
14
《中国输血杂志》 CAS CSCD 2001年第S1期378-,共1页
关键词 Analysis and counter measure in blood grouping errors of volunteers
下载PDF
Algorithms for automatic measurement of SIS-type hysteretic underdamped Josephson junction’s parameters by current-voltage characteristics
15
作者 Aleksey G.Vostretsov Svetlana G.Filatova 《Journal of Electronic Science and Technology》 EI CSCD 2023年第4期60-74,共15页
Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic nois... Some electrical parameters of the SIS-type hysteretic underdamped Josephson junction(JJ)can be measured by its current-voltage characteristics(IVCs).Currents and voltages at JJ are commensurate with the intrinsic noise level of measuring instruments.This leads to the need for multiple measurements with subsequent statistical processing.In this paper,the digital algorithms are proposed for the automatic measurement of the JJ parameters by IVC.These algorithms make it possible to implement multiple measurements and check these JJ parameters in an automatic mode with the required accuracy.The complete sufficient statistics are used to minimize the root-mean-square error of parameter measurement.A sequence of current pulses with slow rising and falling edges is used to drive JJ,and synchronous current and voltage readings at JJ are used to realize measurement algorithms.The algorithm performance is estimated through computer simulations.The significant advantage of the proposed algorithms is the independence from current source noise and intrinsic noise of current and voltage meters,as well as the simple implementation in automatic digital measuring systems.The proposed algorithms can be used to control JJ parameters during mass production of superconducting integrated circuits,which will improve the production efficiency and product quality. 展开更多
关键词 Algorithm design and analysis Critical current Current-voltage characteristics(IVCs) Josephson junction(JJ) measurement errors Parameter estimation
下载PDF
Positional Error Model of Line Segments with Modeling and Measuring Errors Using Brownian Bridge
16
作者 Xiaohua TONG Lejingyi ZHOU Yanmin JIN 《Journal of Geodesy and Geoinformation Science》 CSCD 2023年第2期1-10,共10页
Spatial linear features are often represented as a series of line segments joined by measured endpoints in surveying and geographic information science.There are not only the measuring errors of the endpoints but also... Spatial linear features are often represented as a series of line segments joined by measured endpoints in surveying and geographic information science.There are not only the measuring errors of the endpoints but also the modeling errors between the line segments and the actual geographical features.This paper presents a Brownian bridge error model for line segments combining both the modeling and measuring errors.First,the Brownian bridge is used to establish the position distribution of the actual geographic feature represented by the line segment.Second,an error propagation model with the constraints of the measuring error distribution of the endpoints is proposed.Third,a comprehensive error band of the line segment is constructed,wherein both the modeling and measuring errors are contained.The proposed error model can be used to evaluate line segments’overall accuracy and trustability influenced by modeling and measuring errors,and provides a comprehensive quality indicator for the geospatial data. 展开更多
关键词 spatial data line segment modeling error measuring error Brownian bridge
下载PDF
UAV Velocity Measurement for Ground Moving Target 被引量:2
17
作者 黄大庆 徐诚 +1 位作者 韩伟 王东振 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2015年第1期9-15,共7页
To satisfy the demand of measuring the velocity of ground moving target through unmanned aerial vehicle(UAV)electro-optical platform,two velocity measurement methods are proposed.Firstly,a velocity measurement method ... To satisfy the demand of measuring the velocity of ground moving target through unmanned aerial vehicle(UAV)electro-optical platform,two velocity measurement methods are proposed.Firstly,a velocity measurement method based on target localization is derived,using the position difference between two points with the advantages of easy deployment and realization.Then a mathematical model for measuring target velocity is built and described by 15 variables,i.e.UAV velocity,UAV attitude angular rate,camera direction angular rate and so on.Moreover,the causes of velocity measurement error are analyzed and a formula is derived for calculating the measurement error.Finally,the simulation results show that angular rate error has a strong influence on the velocity measurement accuracy,especially the UAV pitch angular rate error,roll angular rate error and the camera angular altitude rate error,thus indicating the direction for improving velocity measurement precision. 展开更多
关键词 unmanned aerial vehicle(UAV) target velocity measurement target localization velocity measurement error
下载PDF
A convenient look-up-table based method for the compensation of non-linear error in digital fringe projection 被引量:8
18
作者 Chen Xiong Jun Yao +1 位作者 Jubing Chen Hong Miao 《Theoretical & Applied Mechanics Letters》 CAS CSCD 2016年第1期49-53,共5页
Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this... Although the structured light system that uses digital fringe projection has been widely implemented in three-dimensional surface profile measurement, the measurement system is susceptible to non-linear error. In this work, we propose a convenient look-up-table-based (LUT-based) method to compensate for the non-linear error in captured fringe patterns. Without extra calibration, this LUT-based method completely utilizes the captured fringe pattern by recording the full-field differences. Then, a phase compensation map is established to revise the measured phase. Experimental results demonstrate that this method works effectively. 展开更多
关键词 Phase measurement Digital fringe projection Non-linear error compensation Digital image processing
下载PDF
ERROR COMPENSATION OF COORDINATE MEASURING MACHINES WITH LOW STIFFNESS 被引量:1
19
作者 Zhao Yingjian Zhang Guoxiong (College of Precision Instruments and Optical Electronics, Tianjin University) 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2000年第2期159-164,共6页
A technique for compensating the errors of coordinate measuring machines (CMMs) with low stiffness is proposed. Some additional items related with the force deformation are introduced to the error compensation aquatio... A technique for compensating the errors of coordinate measuring machines (CMMs) with low stiffness is proposed. Some additional items related with the force deformation are introduced to the error compensation aquations. The research was carried on a moving colunm horizontal arm CMM. Experimental results show that both the effects of systematic components of error motions and force deformations are greatly reduced, which shows the effectiveness of proposed technique. 展开更多
关键词 error compensation Coordinate measuring machine(CMM) Low stiffness
下载PDF
An Improved Method for Correction of Air Temperature Measured Using Different Radiation Shields
20
作者 CHENG Xinghong SU Debin +6 位作者 LI Deping CHEN Lu XU Wenjing YANG Meilin LI Yongcheng YUE Zhizhong WANG Zijing 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2014年第6期1460-1468,共9页
The variation of air temperature measurement errors using two different radiation shields (DTR502B Vaisala,Finland,and HYTFZ01,Huayun Tongda Satcom,China) was studied.Datasets were collected in the field at the Daxi... The variation of air temperature measurement errors using two different radiation shields (DTR502B Vaisala,Finland,and HYTFZ01,Huayun Tongda Satcom,China) was studied.Datasets were collected in the field at the Daxing weather station in Beijing from June 2011 to May 2012.Most air temperature values obtained with these two commonly used radiation shields were lower than the reference records obtained with the new Fiber Reinforced Polymers (FRP) Stevenson screen.In most cases,the air temperature errors when using the two devices were smaller on overcast and rainy days than on sunny days; and smaller when using the imported rather than the Chinese shield.The measured errors changed sharply at sunrise and sunset,and reached maxima at noon.Their diurnal variation characteristics were,naturally,related to changes in solar radiation.The relationships between the record errors,global radiation,and wind speed were nonlinear.An improved correction method was proposed based on the approach described by Nakamura and Mahrt (2005) (NM05),in which the impact of the solar zenith angle (SZA) on the temperature error is considered and extreme errors due to changes in SZA can be corrected effectively.Measurement errors were reduced significantly after correction by either method for both shields.The error reduction rate using the improved correction method for the Chinese and imported shields were 3.3% and 40.4% higher than those using the NM05 method,respectively. 展开更多
关键词 radiation shield measurement error impacts of solar zenith angle improved correction method