Purpose: To determine and compare the concentrations of etoposide achieved in the aqueous and vitreous humors after intravenous and subconjunctival administration . Methods: Eight New Zealand rabbits were treated with...Purpose: To determine and compare the concentrations of etoposide achieved in the aqueous and vitreous humors after intravenous and subconjunctival administration . Methods: Eight New Zealand rabbits were treated with etoposide (5mg/kg) intravenous and etoposide (2.5mg/ml,0.5ml) subconjunctival respectively. The samples of the aqueous and vitreous humors of rabbits were drawed at 1,2,3 hours after the end of infusion. The concentrations of the etoposide were determined by high-performance liquid chromatography. A Diamonsil TM C18 column ( 6×40 mm, 3 μm ) with a mobile phase of 400 ml of methanol and 600 ml of 100 mmol.L-1 sodium dihydrogen phosphate with 0.02 mmol.L-1 dioctyl sodium sulfosuccinate and 0.5% triethylanine (pH value was adjusted to 6 by phosphoric acid) was used. The detective wavelength was at 235nm and the flow rate was 1.0ml.min-1.Results: The concentrations of etoposide in aqueous and vitreous humors after administr-ated in intravenous for 1, 2, 3 hours were 38.5, 52.2, 44.1(ng/ml) and 12.0, 25.1, 18.0(ng/ml) respectively. The concentrations of etoposide in aqueous and vitreous humors after infused in subconjunctival for 1,2,3 hours were 98.0, 113.0, 99.0 (ng/ml) and 43.7, 66.7, 32.4 (ng/ml) respectively. The concentrations in the aqueous and vitreous humor after local administrated were 2 to 4 times higher than those obtained after intravenous administration. There are statistical significance between the concentrations of etoposide of aqueous and vitreous humor after intravenous and subconjunctival administration .Conclusions: The delivery of subconjunctival of etoposide results in higher concentrations in aqueous and vitreous humors than intravenous administration. These results suggest that local administration of chemotherapeutic agents should be more effective for retinoblas-toma chemotherapy than systemic administration.展开更多
Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stre...Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stress,the three-dimensional(3D)stress tensors at 89 measuring points determined using an improved overcoring technique in nine mines in China were adopted,a newly defined characteristic parameter C_(ERP)was proposed as an indicator for evaluating the structural properties of rock masses,and a fuzzy relation matrix was established using the information distribution method.The results indicate that both the vertical stress and horizontal stress exhibit a good linear growth relationship with depth.There is no remarkable correlation between the elastic modulus,Poisson's ratio and depth,and the distribution of data points is scattered and messy.Moreover,there is no obvious relationship between the rock quality designation(RQD)and depth.The maximum horizontal stress σ_(H) is a function of rock properties,showing a certain linear relationship with the C_(ERP)at the same depth.In addition,the overall change trend of σ_(H) determined by the established fuzzy identification method is to increase with the increase of C_(ERP).The fuzzy identification method also demonstrates a relatively detailed local relationship betweenσ_H and C_(ERP),and the predicted curve rises in a fluctuating way,which is in accord well with the measured stress data.展开更多
Dual-comb ranging allows rapid and precise distance measurement and can be universally implemented on different comb platforms,e.g.,fiber combs and microcombs.To date,dual-fiber-comb ranging has become a mature and po...Dual-comb ranging allows rapid and precise distance measurement and can be universally implemented on different comb platforms,e.g.,fiber combs and microcombs.To date,dual-fiber-comb ranging has become a mature and powerful tool for metrology and industry,but the measurement speed is often at a kilohertz level due to the lower repetition rates.Recently,dual-microcomb ranging has given rise to a new opportunity for distance measurement,in consequence of its small footprint and high repetition rates,but full-comb stabilization is challenging.Here,we report a dual-hybrid-comb distance meter capable of ultrarapid and submicrometer precision distance measurement,which can not only leverage the advantage of easy locking inherited from the fiber comb but also sustain ultrarapid measurement speed due to the microcomb.The experimental results show that the measurement precision can reach 3.572μm at 4.136μs and 432 nm at 827.2μs averaging time.Benefiting from the large difference between the repetition rates of the hybrid combs,the measurement speed can be enhanced by 196 folds,in contrast to the dual-fiber-comb system with about a 250 MHz repetition rate.Our work can offer a solution for the fields of rapid dimensional measurement and spectroscopy.展开更多
In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation o...In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results.展开更多
This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si...This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.展开更多
A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The sw...A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The swirling blades are used to transform the complex flow pattern into a forced annular flow.Drawing on the research of existing blockage flow meters and also exploiting the single-phase flow measurement theory,a formula is introduced to measure the phase-separated flow of gas and liquid.The formula requires the pressure ratio,Lockhart-Martinelli number(L-M number),and the gas phase Froude number.The unknown parameters appearing in the formula are fitted through numerical simulation using computational fluid dynamics(CFD),which involves a comprehensive analysis of the flow field inside the device from multiple perspectives,and takes into account the influence of pressure fluctuations.Finally,the measurement model is validated through an experimental error analysis.The results demonstrate that the measurement error can be maintained within±8%for various flow patterns,including stratified flow,bubble flow,and wave flow.展开更多
This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address th...This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing.展开更多
The accuracy of power system measurements directly affects the safe and stable operation of power grids. This study explores the application prospects of quantum sensing technology in power system measurements. The re...The accuracy of power system measurements directly affects the safe and stable operation of power grids. This study explores the application prospects of quantum sensing technology in power system measurements. The research first analyzes the limitations of traditional measurement techniques, such as electromagnetic interference sensitivity and measurement accuracy bottlenecks. It then introduces the basic principles of quantum sensing, including concepts like quantum entanglement and superposition states. Through theoretical analysis and numerical simulations, the study assesses the potential advantages of quantum sensors in current, voltage, and magnetic field measurements. Results show that quantum magnetometers offer significant improvements in accuracy and interference resistance for current measurements. The study also discusses the application of quantum optical technology in high-voltage measurements, demonstrating its unique advantages in improving measurement dynamic range. However, quantum sensing technology still faces challenges in practical applications, such as technological maturity and cost. To address these issues, the research proposes a phased implementation strategy and industry-academia collaboration model. Finally, the study envisions future directions combining quantum sensing with artificial intelligence. This research provides a theoretical foundation for innovative upgrades in power system measurement technology.展开更多
Exosomes,lipid bilayer-enclosed small cellular vesicles,are actively secreted by various cells and play crucial roles in intercellular communication.These nanosized vesicles transport internalized proteins,mRNA,miRNA,...Exosomes,lipid bilayer-enclosed small cellular vesicles,are actively secreted by various cells and play crucial roles in intercellular communication.These nanosized vesicles transport internalized proteins,mRNA,miRNA,and other bioactive molecules.Recent findings have provided compelling evidence that exosomes derived from stem cells hold great promise as a therapeutic modality for central nervous system disorders.These exosomes exhibit multifaceted properties including antiapoptotic,anti-inflammatory,neurogenic,and vasculogenic effects.Furthermore,exosomes offer several advantages over stem cell therapy,such as high preservation capacity,low immunogenicity,the ability to traverse the blood-brain barrier,and the potential for drug encapsulation.Consequently,researchers have turned their attention to exosomes as a novel therapeutic avenue.Nonetheless,akin to the limitations of stem cell treatment,the limited accumulation of exosomes in the injured brain poses a challenge to their clinical application.To overcome this hurdle,intranasal administration has emerged as a non-invasive and efficacious route for delivering drugs to the central nervous system.By exploiting the olfactory and trigeminal nerve axons,this approach enables the direct transport of therapeutics to the brain while bypassing the blood-brain barrier.Notably,exosomes,owing to their small size,can readily access the nerve pathways using this method.As a result,intranasal administration has gained increasing recognition as an optimal therapeutic strategy for exosomebased treatments.In this comprehensive review,we aim to provide an overview of both basic and clinical research studies investigating the intranasal administration of exosomes for the treatment of central nervous system diseases.Furthermore,we elucidate the underlying therapeutic mechanisms and offer insights into the prospect of this approach.展开更多
Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram....Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.展开更多
Atmospheric O_(x)(nitrogen dioxide(NO_(2))+ozone(O_(3)))can better reflect the local and regional change character-istics of oxidants compared to O_(3)alone,so obtaining O_(x)accurately and rapidly is the basis for ev...Atmospheric O_(x)(nitrogen dioxide(NO_(2))+ozone(O_(3)))can better reflect the local and regional change character-istics of oxidants compared to O_(3)alone,so obtaining O_(x)accurately and rapidly is the basis for evaluating the O_(3)production rate.Furthermore,O_(x)has proved to be a more representative indicator and can serve as a reflection of pollution prevention efficacy.A portable instrument for measuring atmospheric O_(x)and NO_(2)based on cavity ring-down spectroscopy(O_(x)/NO_(2)-CRDS)was developed in this work.The NO_(2)concentration is accurately mea-sured according to its absorption characteristic at 407.86 nm.Ambient O_(3)is converted into NO_(2)by chemical titration of high concentrations of nitrogen oxide(NO),and the O_(3)conversion efficiencies obtained are nearly 99%.The detection limit of the O_(x)/NO_(2)-CRDS system for O_(x)is 0.024 ppbv(0.1 s),and the overall uncertainty of the instrument is±6%.Moreover,the Kalman filtering technique was applied to improve the measurement accuracy of O_(x)/NO_(2)-CRDS.The system was applied in a comprehensive field observation campaign at Hefei Sci-ence Island from 26 to 30 September 2022,and the time concentration series and change characteristics of O_(x)and NO_(2)were obtained for five days.The measured O_(x)concentrations were compared with those of two com-mercial instruments,and the consistency was good(R^(2)=0.98),indicating that this system can be deployed to accurately and rapidly obtain the concentrations of atmospheric O_(x)and NO_(2).It will be a useful tool for assessing the atmospheric oxidation capacity and controlling O_(3)pollution.展开更多
Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted ...Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection.展开更多
It remains a great challenge to understand the hydrates involved in phenomena in practical oil and gas systems.The adhesion forces between hydrate particles,between hydrate particles and pipe walls,and between hydrate...It remains a great challenge to understand the hydrates involved in phenomena in practical oil and gas systems.The adhesion forces between hydrate particles,between hydrate particles and pipe walls,and between hydrate particles and reservoir particles are essential factors that control the behaviors of clathrate hydrates in different applications.In this review,we summarize the typical micro-force measurement apparatus and methods utilized to study hydrate particle systems.In addition,the adhesion test results,the related understandings,and the applied numerical calculation models are systematically discussed.展开更多
In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Lar...In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist.展开更多
The measurement and mapping of objects in the outer environment have traditionally been conducted using ground-based monitoring systems,as well as satellites.More recently,unmanned aerial vehicles have also been emplo...The measurement and mapping of objects in the outer environment have traditionally been conducted using ground-based monitoring systems,as well as satellites.More recently,unmanned aerial vehicles have also been employed for this purpose.The accurate detection and mapping of a target such as buildings,trees,and terrains are of utmost importance in various applications of unmanned aerial vehicles(UAVs),including search and rescue operations,object transportation,object detection,inspection tasks,and mapping activities.However,the rapid measurement and mapping of the object are not currently achievable due to factors such as the object’s size,the intricate nature of the sites,and the complexity of mapping algorithms.The present system introduces a costeffective solution for measurement and mapping by utilizing a small unmanned aerial vehicle(UAV)equipped with an 8-beam Light Detection and Ranging(LiDAR)system.This approach offers advantages over traditional methods that rely on expensive cameras and complex algorithm-based approaches.The reflective properties of laser beams have also been investigated.The system provides prompt results in comparison to traditional camerabased surveillance,with minimal latency and the need for complex algorithms.The Kalman estimation method demonstrates improved performance in the presence of noise.The measurement and mapping of external objects have been successfully conducted at varying distances,utilizing different resolutions.展开更多
The vibration interference of the reference corner cube runs through the free flight process of the free-falling corner cube,which is superimposed on the whole laser interference fringes.Thus,it is necessary to solve ...The vibration interference of the reference corner cube runs through the free flight process of the free-falling corner cube,which is superimposed on the whole laser interference fringes.Thus,it is necessary to solve the interference fringes with the entire fringe to analyze the quantitative influence of vibration on gravity measurements.展开更多
Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sour...Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sources,the detector response can reflect various types of information of the medium.The Monte Carlo method is one of the primary methods used to obtain nuclear detection responses in complex environments.However,this requires a computational process with extensive random sampling,consumes considerable resources,and does not provide real-time response results.Therefore,a novel fast forward computational method(FFCM)for nuclear measurement that uses volumetric detection constraints to rapidly calculate the detector response in various complex environments is proposed.First,the data library required for the FFCM is built by collecting the detection volume,detector counts,and flux sensitivity functions through a Monte Carlo simulation.Then,based on perturbation theory and the Rytov approximation,a model for the detector response is derived using the flux sensitivity function method and a one-group diffusion model.The environmental perturbation is constrained to optimize the model according to the tool structure and the impact of the formation and borehole within the effective detection volume.Finally,the method is applied to a neutron porosity tool for verification.In various complex simulation environments,the maximum relative error between the calculated porosity results of Monte Carlo and FFCM was 6.80%,with a rootmean-square error of 0.62 p.u.In field well applications,the formation porosity model obtained using FFCM was in good agreement with the model obtained by interpreters,which demonstrates the validity and accuracy of the proposed method.展开更多
This article uses the method of legal text analysis to systematically sort out the legal norms,administrative normative documents,and other normative documents in the regulation system of cosmetics.It focuses on discu...This article uses the method of legal text analysis to systematically sort out the legal norms,administrative normative documents,and other normative documents in the regulation system of cosmetics.It focuses on discussing the definitions,legal attributes,sources,and effectiveness of laws,administrative regulations,departmental rules,administrative normative documents,standards,specification,and guiding principles.展开更多
Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and...Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and time-lapse seismic surveillance of both conventional and unconventional reservoir and overburden performances.A Seismic Elastic Moduli Module has been developed,based on the forced-oscillations method,to experimentally investigate the frequency dependence of Young's modulus and Poisson's ratio,as well as the inferred attenuation,of cylindrical samples under different confining pressure conditions.Calibration with three standard samples showed that the measured elastic moduli were consistent with the published data,indicating that the new apparatus can operate reliably over a wide frequency range of f∈[1-2000,10^(6)]Hz.The Young's modulus and Poisson's ratio of the shale and the tight sandstone samples were measured under axial stress oscillations to assess the frequency-and pressure-dependent effects.Under dry condition,both samples appear to be nearly frequency independent,with weak pressure dependence for the shale and significant pressure dependence for the sandstone.In particular,it was found that the tight sandstone with complex pore microstructure exhibited apparent dispersion and attenuation under brine or glycerin saturation conditions,the levels of which were strongly influenced by the increased effective pressure.In addition,the measured Young's moduli results were compared with the theoretical predictions from a scaled poroelastic model with a reasonably good agreement,revealing that the combined fluid flow mechanisms at both mesoscopic and microscopic scales possibly responsible for the measured dispersion.展开更多
Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the co...Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the context of projective measurements,focusing on the quantification of such coherence.Firstly,we define the correlation function between the two general projective measurements P and Q,and analyze the connection between sets of block incoherent states related to two compatible projective measurements P and Q.Secondly,we discuss the measure of quantum block coherence with respect to projective measurements.Based on a given measure of quantum block coherence,we characterize the existence of maximal block coherent states through projective measurements.This research integrates the compatibility of projective measurements with the framework of quantum block coherence,contributing to the advancement of block coherence measurement theory.展开更多
文摘Purpose: To determine and compare the concentrations of etoposide achieved in the aqueous and vitreous humors after intravenous and subconjunctival administration . Methods: Eight New Zealand rabbits were treated with etoposide (5mg/kg) intravenous and etoposide (2.5mg/ml,0.5ml) subconjunctival respectively. The samples of the aqueous and vitreous humors of rabbits were drawed at 1,2,3 hours after the end of infusion. The concentrations of the etoposide were determined by high-performance liquid chromatography. A Diamonsil TM C18 column ( 6×40 mm, 3 μm ) with a mobile phase of 400 ml of methanol and 600 ml of 100 mmol.L-1 sodium dihydrogen phosphate with 0.02 mmol.L-1 dioctyl sodium sulfosuccinate and 0.5% triethylanine (pH value was adjusted to 6 by phosphoric acid) was used. The detective wavelength was at 235nm and the flow rate was 1.0ml.min-1.Results: The concentrations of etoposide in aqueous and vitreous humors after administr-ated in intravenous for 1, 2, 3 hours were 38.5, 52.2, 44.1(ng/ml) and 12.0, 25.1, 18.0(ng/ml) respectively. The concentrations of etoposide in aqueous and vitreous humors after infused in subconjunctival for 1,2,3 hours were 98.0, 113.0, 99.0 (ng/ml) and 43.7, 66.7, 32.4 (ng/ml) respectively. The concentrations in the aqueous and vitreous humor after local administrated were 2 to 4 times higher than those obtained after intravenous administration. There are statistical significance between the concentrations of etoposide of aqueous and vitreous humor after intravenous and subconjunctival administration .Conclusions: The delivery of subconjunctival of etoposide results in higher concentrations in aqueous and vitreous humors than intravenous administration. These results suggest that local administration of chemotherapeutic agents should be more effective for retinoblas-toma chemotherapy than systemic administration.
基金financially supported by the National Natural Science Foundation of China(No.52204084)the Open Research Fund of the State Key Laboratory of Coal Resources and safe Mining,CUMT,China(No.SKLCRSM 23KF004)+3 种基金the Interdisciplinary Research Project for Young Teachers of USTB(Fundamental Research Funds for the Central Universities),China(No.FRF-IDRY-GD22-002)the Fundamental Research Funds for the Central Universities and the Youth Teacher International Exchange and Growth Program,China(No.QNXM20220009)the National Key R&D Program of China(Nos.2022YFC2905600 and 2022 YFC3004601)the Science,Technology&Innovation Project of Xiongan New Area,China(No.2023XAGG0061)。
文摘Understanding the mechanical properties of the lithologies is crucial to accurately determine the horizontal stress magnitude.To investigate the correlation between the rock mass properties and maximum horizontal stress,the three-dimensional(3D)stress tensors at 89 measuring points determined using an improved overcoring technique in nine mines in China were adopted,a newly defined characteristic parameter C_(ERP)was proposed as an indicator for evaluating the structural properties of rock masses,and a fuzzy relation matrix was established using the information distribution method.The results indicate that both the vertical stress and horizontal stress exhibit a good linear growth relationship with depth.There is no remarkable correlation between the elastic modulus,Poisson's ratio and depth,and the distribution of data points is scattered and messy.Moreover,there is no obvious relationship between the rock quality designation(RQD)and depth.The maximum horizontal stress σ_(H) is a function of rock properties,showing a certain linear relationship with the C_(ERP)at the same depth.In addition,the overall change trend of σ_(H) determined by the established fuzzy identification method is to increase with the increase of C_(ERP).The fuzzy identification method also demonstrates a relatively detailed local relationship betweenσ_H and C_(ERP),and the predicted curve rises in a fluctuating way,which is in accord well with the measured stress data.
基金supported by the National Key Research and Development Program of China(Grant No.2021YFB2800603)the CAS Project for Young Scientists in Basic Research(Grant No.YSBR-069)+1 种基金the National Natural Science Foundation of China(Grant Nos.62075238 and 12275093)the Innovation Program for Quantum Science and Technology(Grant Nos.2021ZD0301500 and 2021ZD0300701).
文摘Dual-comb ranging allows rapid and precise distance measurement and can be universally implemented on different comb platforms,e.g.,fiber combs and microcombs.To date,dual-fiber-comb ranging has become a mature and powerful tool for metrology and industry,but the measurement speed is often at a kilohertz level due to the lower repetition rates.Recently,dual-microcomb ranging has given rise to a new opportunity for distance measurement,in consequence of its small footprint and high repetition rates,but full-comb stabilization is challenging.Here,we report a dual-hybrid-comb distance meter capable of ultrarapid and submicrometer precision distance measurement,which can not only leverage the advantage of easy locking inherited from the fiber comb but also sustain ultrarapid measurement speed due to the microcomb.The experimental results show that the measurement precision can reach 3.572μm at 4.136μs and 432 nm at 827.2μs averaging time.Benefiting from the large difference between the repetition rates of the hybrid combs,the measurement speed can be enhanced by 196 folds,in contrast to the dual-fiber-comb system with about a 250 MHz repetition rate.Our work can offer a solution for the fields of rapid dimensional measurement and spectroscopy.
文摘In order to accurately measure an object’s three-dimensional surface shape,the influence of sampling on it was studied.First,on the basis of deriving spectra expressions through the Fourier transform,the generation of CCD pixels was analyzed,and its expression was given.Then,based on the discrete expression of deformation fringes obtained after sampling,its Fourier spectrum expression was derived,resulting in an infinitely repeated"spectra island"in the frequency domain.Finally,on the basis of using a low-pass filter to remove high-order harmonic components and retaining only one fundamental frequency component,the inverse Fourier transform was used to reconstruct the signal strength.A method of reducing the sampling interval,i.e.,reducing the number of sampling points per fringe,was proposed to increase the ratio between the sampling frequency and the fundamental frequency of the grating.This was done to reconstruct the object’s surface shape more accurately under the condition of m>4.The basic principle was verified through simulation and experiment.In the simulation,the sampling intervals were 8 pixels,4 pixels,2 pixels,and 1 pixel,the maximum absolute error values obtained in the last three situations were 88.80%,38.38%,and 31.50%in the first situation,respectively,and the corresponding average absolute error values are 71.84%,43.27%,and 32.26%.It is demonstrated that the smaller the sampling interval,the better the recovery effect.Taking the same four sampling intervals in the experiment as in the simulation can also lead to the same conclusions.The simulated and experimental results show that reducing the sampling interval can improve the accuracy of object surface shape measurement and achieve better reconstruction results.
基金supported by the National Key R&D Program(No.2022YFA1602201)。
文摘This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.
基金Supported By Open Fund of Hubei Key Laboratory of Oil and Gas Drilling and Production Engineering(Yangtze University),YQZC202309.
文摘A new measurement device,consisting of swirling blades and capsule-shaped throttling elements,is proposed in this study to eliminate typical measurement errors caused by complex flow patterns in gas-liquid flow.The swirling blades are used to transform the complex flow pattern into a forced annular flow.Drawing on the research of existing blockage flow meters and also exploiting the single-phase flow measurement theory,a formula is introduced to measure the phase-separated flow of gas and liquid.The formula requires the pressure ratio,Lockhart-Martinelli number(L-M number),and the gas phase Froude number.The unknown parameters appearing in the formula are fitted through numerical simulation using computational fluid dynamics(CFD),which involves a comprehensive analysis of the flow field inside the device from multiple perspectives,and takes into account the influence of pressure fluctuations.Finally,the measurement model is validated through an experimental error analysis.The results demonstrate that the measurement error can be maintained within±8%for various flow patterns,including stratified flow,bubble flow,and wave flow.
文摘This study aims to improve the accuracy and safety of steel plate thickness calibration.A differential noncontact thickness measurement calibration system based on laser displacement sensors was designed to address the problems of low precision of traditional contact thickness gauges and radiation risks of radiation-based thickness gauges.First,the measurement method and measurement structure of the thickness calibration system were introduced.Then,the hardware circuit of the thickness system was established based on the STM32 core chip.Finally,the system software was designed to implement system control to filter algorithms and human-computer interaction.Experiments have proven the excellent performance of the differential noncontact thickness measurement calibration system based on laser displacement sensors,which not only considerably improves measurement accuracy but also effectively reduces safety risks during the measurement process.The system offers guiding significance and application value in the field of steel plate production and processing.
文摘The accuracy of power system measurements directly affects the safe and stable operation of power grids. This study explores the application prospects of quantum sensing technology in power system measurements. The research first analyzes the limitations of traditional measurement techniques, such as electromagnetic interference sensitivity and measurement accuracy bottlenecks. It then introduces the basic principles of quantum sensing, including concepts like quantum entanglement and superposition states. Through theoretical analysis and numerical simulations, the study assesses the potential advantages of quantum sensors in current, voltage, and magnetic field measurements. Results show that quantum magnetometers offer significant improvements in accuracy and interference resistance for current measurements. The study also discusses the application of quantum optical technology in high-voltage measurements, demonstrating its unique advantages in improving measurement dynamic range. However, quantum sensing technology still faces challenges in practical applications, such as technological maturity and cost. To address these issues, the research proposes a phased implementation strategy and industry-academia collaboration model. Finally, the study envisions future directions combining quantum sensing with artificial intelligence. This research provides a theoretical foundation for innovative upgrades in power system measurement technology.
基金supported by KAKENHI under grant number 23K08535,22K09274(to MK)。
文摘Exosomes,lipid bilayer-enclosed small cellular vesicles,are actively secreted by various cells and play crucial roles in intercellular communication.These nanosized vesicles transport internalized proteins,mRNA,miRNA,and other bioactive molecules.Recent findings have provided compelling evidence that exosomes derived from stem cells hold great promise as a therapeutic modality for central nervous system disorders.These exosomes exhibit multifaceted properties including antiapoptotic,anti-inflammatory,neurogenic,and vasculogenic effects.Furthermore,exosomes offer several advantages over stem cell therapy,such as high preservation capacity,low immunogenicity,the ability to traverse the blood-brain barrier,and the potential for drug encapsulation.Consequently,researchers have turned their attention to exosomes as a novel therapeutic avenue.Nonetheless,akin to the limitations of stem cell treatment,the limited accumulation of exosomes in the injured brain poses a challenge to their clinical application.To overcome this hurdle,intranasal administration has emerged as a non-invasive and efficacious route for delivering drugs to the central nervous system.By exploiting the olfactory and trigeminal nerve axons,this approach enables the direct transport of therapeutics to the brain while bypassing the blood-brain barrier.Notably,exosomes,owing to their small size,can readily access the nerve pathways using this method.As a result,intranasal administration has gained increasing recognition as an optimal therapeutic strategy for exosomebased treatments.In this comprehensive review,we aim to provide an overview of both basic and clinical research studies investigating the intranasal administration of exosomes for the treatment of central nervous system diseases.Furthermore,we elucidate the underlying therapeutic mechanisms and offer insights into the prospect of this approach.
文摘Accurate and reliable information about the temperature of the synchronous generators excitation winding hot spot is necessary to determine the dynamic limit caused by excitation winding overheating in the PQ diagram. For good estimation of a position and the hot spot temperature it is decided to mount 19 temperature probes on one pole of the 6-pole, 400 kVA. 50 llz synchronous generator. Due to a large number of the probes and because the probes should be glued with the metal epoxy it was assumed that mounting of the probes will disrupt the temperature field of the excitation winding. To get the answer to this question the excitation winding resistance was measured betbre and after mounting the probes, in a hot and a cold state. Temperature rise can be estimated if the resistance ratio in the hot and the cold state is known. The paper also addresses the analysis of the measurement accuracy. The result shows that, there is no significant influence on the temperature when mounting the 19 temperature probes which covered 10% of the pole excitation winding surface.
基金supported by the National Natural Science Foundation of China[grant number 62275250]the Natural Science Foundation of Anhui Province[grant number 2008085J20]+1 种基金the National Key R&D Program of China[grant number 2022YFC3700301]the Anhui Provincial Key R&D Program[grant number 2022l07020022]。
文摘Atmospheric O_(x)(nitrogen dioxide(NO_(2))+ozone(O_(3)))can better reflect the local and regional change character-istics of oxidants compared to O_(3)alone,so obtaining O_(x)accurately and rapidly is the basis for evaluating the O_(3)production rate.Furthermore,O_(x)has proved to be a more representative indicator and can serve as a reflection of pollution prevention efficacy.A portable instrument for measuring atmospheric O_(x)and NO_(2)based on cavity ring-down spectroscopy(O_(x)/NO_(2)-CRDS)was developed in this work.The NO_(2)concentration is accurately mea-sured according to its absorption characteristic at 407.86 nm.Ambient O_(3)is converted into NO_(2)by chemical titration of high concentrations of nitrogen oxide(NO),and the O_(3)conversion efficiencies obtained are nearly 99%.The detection limit of the O_(x)/NO_(2)-CRDS system for O_(x)is 0.024 ppbv(0.1 s),and the overall uncertainty of the instrument is±6%.Moreover,the Kalman filtering technique was applied to improve the measurement accuracy of O_(x)/NO_(2)-CRDS.The system was applied in a comprehensive field observation campaign at Hefei Sci-ence Island from 26 to 30 September 2022,and the time concentration series and change characteristics of O_(x)and NO_(2)were obtained for five days.The measured O_(x)concentrations were compared with those of two com-mercial instruments,and the consistency was good(R^(2)=0.98),indicating that this system can be deployed to accurately and rapidly obtain the concentrations of atmospheric O_(x)and NO_(2).It will be a useful tool for assessing the atmospheric oxidation capacity and controlling O_(3)pollution.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 92065113, 11904357, 62075208, and 12174367)the Innovation Programme for Quantum Science and Technology (Grant No. 2021ZD0301604)+1 种基金the National Key Research and Development Program of China (Grant No. 2021YFE0113100)supported by Beijing Academy of Quantum Information Sciences
文摘Weak measurement amplification,which is considered as a very promising scheme in precision measurement,has been applied to various small physical quantities estimations.Since many physical quantities can be converted into phase signals,it is interesting and important to consider measuring small longitudinal phase shifts by using weak measurement.Here,we propose and experimentally demonstrate a novel weak measurement amplification-based small longitudinal phase estimation,which is suitable for polarization interferometry.We realize one order of magnitude amplification measurement of a small phase signal directly introduced by a liquid crystal variable retarder and show that it is robust to the imperfection of interference.Besides,we analyze the effect of magnification error which is never considered in the previous works,and find the constraint on the magnification.Our results may find important applications in high-precision measurements,e.g.,gravitational wave detection.
基金supported by the National Key Research and Development Project (No.2018YFE0126400)Key Program of Marine Economy Development (Six Marine Industries)Special Foundation of Department of Natural Resources of Guangdong Province (GDNRC[2020]047)。
文摘It remains a great challenge to understand the hydrates involved in phenomena in practical oil and gas systems.The adhesion forces between hydrate particles,between hydrate particles and pipe walls,and between hydrate particles and reservoir particles are essential factors that control the behaviors of clathrate hydrates in different applications.In this review,we summarize the typical micro-force measurement apparatus and methods utilized to study hydrate particle systems.In addition,the adhesion test results,the related understandings,and the applied numerical calculation models are systematically discussed.
基金supported by Beijing Insititute of Technology Research Fund Program for Young Scholars(2020X04104)。
文摘In this paper,an improved spatio-temporal alignment measurement method is presented to address the inertial matching measurement of hull deformation under the coexistence of time delay and large misalignment angle.Large misalignment angle and time delay often occur simultaneously and bring great challenges to the accurate measurement of hull deformation in space and time.The proposed method utilizes coarse alignment with large misalignment angle and time delay estimation of inertial measurement unit modeling to establish a brand-new spatiotemporal aligned hull deformation measurement model.In addition,two-step loop control is designed to ensure the accurate description of dynamic deformation angle and static deformation angle by the time-space alignment method of hull deformation.The experiments illustrate that the proposed method can effectively measure the hull deformation angle when time delay and large misalignment angle coexist.
基金funded through the Researchers Supporting Project Number(RSPD2024R596),King Saud University,Riyadh,Saudi Arabia.
文摘The measurement and mapping of objects in the outer environment have traditionally been conducted using ground-based monitoring systems,as well as satellites.More recently,unmanned aerial vehicles have also been employed for this purpose.The accurate detection and mapping of a target such as buildings,trees,and terrains are of utmost importance in various applications of unmanned aerial vehicles(UAVs),including search and rescue operations,object transportation,object detection,inspection tasks,and mapping activities.However,the rapid measurement and mapping of the object are not currently achievable due to factors such as the object’s size,the intricate nature of the sites,and the complexity of mapping algorithms.The present system introduces a costeffective solution for measurement and mapping by utilizing a small unmanned aerial vehicle(UAV)equipped with an 8-beam Light Detection and Ranging(LiDAR)system.This approach offers advantages over traditional methods that rely on expensive cameras and complex algorithm-based approaches.The reflective properties of laser beams have also been investigated.The system provides prompt results in comparison to traditional camerabased surveillance,with minimal latency and the need for complex algorithms.The Kalman estimation method demonstrates improved performance in the presence of noise.The measurement and mapping of external objects have been successfully conducted at varying distances,utilizing different resolutions.
基金funded by Hebei Key Laboratory of Seismic Disaster Instrument and Monitoring Technology(Grant No.FZ224201)National Key Research and Development Project(Grant No.2022YFC2204301)the Special Fund of the Institute of Earthquake Forecasting,China Earthquake Administration(Grant No.CEAIEF2022030105).
文摘The vibration interference of the reference corner cube runs through the free flight process of the free-falling corner cube,which is superimposed on the whole laser interference fringes.Thus,it is necessary to solve the interference fringes with the entire fringe to analyze the quantitative influence of vibration on gravity measurements.
基金This work is supported by National Natural Science Foundation of China(Nos.U23B20151 and 52171253).
文摘Owing to the complex lithology of unconventional reservoirs,field interpreters usually need to provide a basis for interpretation using logging simulation models.Among the various detection tools that use nuclear sources,the detector response can reflect various types of information of the medium.The Monte Carlo method is one of the primary methods used to obtain nuclear detection responses in complex environments.However,this requires a computational process with extensive random sampling,consumes considerable resources,and does not provide real-time response results.Therefore,a novel fast forward computational method(FFCM)for nuclear measurement that uses volumetric detection constraints to rapidly calculate the detector response in various complex environments is proposed.First,the data library required for the FFCM is built by collecting the detection volume,detector counts,and flux sensitivity functions through a Monte Carlo simulation.Then,based on perturbation theory and the Rytov approximation,a model for the detector response is derived using the flux sensitivity function method and a one-group diffusion model.The environmental perturbation is constrained to optimize the model according to the tool structure and the impact of the formation and borehole within the effective detection volume.Finally,the method is applied to a neutron porosity tool for verification.In various complex simulation environments,the maximum relative error between the calculated porosity results of Monte Carlo and FFCM was 6.80%,with a rootmean-square error of 0.62 p.u.In field well applications,the formation porosity model obtained using FFCM was in good agreement with the model obtained by interpreters,which demonstrates the validity and accuracy of the proposed method.
文摘This article uses the method of legal text analysis to systematically sort out the legal norms,administrative normative documents,and other normative documents in the regulation system of cosmetics.It focuses on discussing the definitions,legal attributes,sources,and effectiveness of laws,administrative regulations,departmental rules,administrative normative documents,standards,specification,and guiding principles.
基金The authors would like to acknowledge financial support from NSFC Basic Research Program on Deep Petroleum Resource Accumulation and Key Engineering Technologies(U19B6003-04-03)National Natural Science Foundation of China(41930425)+2 种基金Beijing Natural Science Foundation(8222073),R&D Department of China National Petroleum Corporation(Investigations on fundamental experiments and advanced theoretical methods in geophysical prospecting applications,2022DQ0604-01)Scientific Research and Technology Development Project of PetroChina(2021DJ1206)National Key Research and Development Program of China(2018YFA0702504).
文摘Knowledge about the seismic elastic modulus dispersion,and associated attenuation,in fluid-saturated rocks is essential for better interpretation of seismic observations taken as part of hydrocarbon identification and time-lapse seismic surveillance of both conventional and unconventional reservoir and overburden performances.A Seismic Elastic Moduli Module has been developed,based on the forced-oscillations method,to experimentally investigate the frequency dependence of Young's modulus and Poisson's ratio,as well as the inferred attenuation,of cylindrical samples under different confining pressure conditions.Calibration with three standard samples showed that the measured elastic moduli were consistent with the published data,indicating that the new apparatus can operate reliably over a wide frequency range of f∈[1-2000,10^(6)]Hz.The Young's modulus and Poisson's ratio of the shale and the tight sandstone samples were measured under axial stress oscillations to assess the frequency-and pressure-dependent effects.Under dry condition,both samples appear to be nearly frequency independent,with weak pressure dependence for the shale and significant pressure dependence for the sandstone.In particular,it was found that the tight sandstone with complex pore microstructure exhibited apparent dispersion and attenuation under brine or glycerin saturation conditions,the levels of which were strongly influenced by the increased effective pressure.In addition,the measured Young's moduli results were compared with the theoretical predictions from a scaled poroelastic model with a reasonably good agreement,revealing that the combined fluid flow mechanisms at both mesoscopic and microscopic scales possibly responsible for the measured dispersion.
基金partially supported by the National Natural Science Foundations of China (Grant No.11901317)the China Postdoctoral Science Foundation (Grant No.2020M680480)+1 种基金the Fundamental Research Funds for the Central Universities (Grant No.2023MS078)the Beijing Natural Science Foundation (Grant No.1232021)。
文摘Quantum coherence serves as a defining characteristic of quantum mechanics,finding extensive applications in quantum computing and quantum communication processing.This study explores quantum block coherence in the context of projective measurements,focusing on the quantification of such coherence.Firstly,we define the correlation function between the two general projective measurements P and Q,and analyze the connection between sets of block incoherent states related to two compatible projective measurements P and Q.Secondly,we discuss the measure of quantum block coherence with respect to projective measurements.Based on a given measure of quantum block coherence,we characterize the existence of maximal block coherent states through projective measurements.This research integrates the compatibility of projective measurements with the framework of quantum block coherence,contributing to the advancement of block coherence measurement theory.