This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch si...This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.展开更多
Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under cond...Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.展开更多
Pulse echo accumulation is commonly employed in coherent Doppler wind LiDAR(light detection and ranging)under the assumption of steady wind.Here,the measured spectral data are analyzed in the time dimension and freque...Pulse echo accumulation is commonly employed in coherent Doppler wind LiDAR(light detection and ranging)under the assumption of steady wind.Here,the measured spectral data are analyzed in the time dimension and frequency dimension to cope with the temporal wind shear and achieve the optimal accumulation time.A hardware-efficient algorithm combining the interpolation and cross-correlation is used to enhance the wind retrieval accuracy by reducing the frequency sampling interval and then reduce the spectral width calculation error.Moreover,the temporal broadening effect and spatial broadening effect are decoupled according to the strategy we developed.展开更多
The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the...The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%.展开更多
Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, wh...Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, which belongs to the African freshwater electric eels but can inspire our bionic interests in propulsion besides its abilities in electric sensing. A special larva of Gyrnnarchus niloticus was morphologically measured by photographing it with a piece of scale-calibrated paper as the background. Then we analyzed the data by a CFD-aided approach. Detailed flow patterns around the larva and a NACA0012 hydrofoil were respectively calculated and visualized at the Reynolds number of 7350 or so. The results show that the profile of Gyrnnarchus niloticus is well streamlined.展开更多
The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied...The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.展开更多
The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical ...The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical industries. The aim of this work was to evaluate and discuss the estimation of uncertainty in pharmaceutical analysis. The uncertainty is a useful tool in the assessment of compliance or non-compliance of in-process and final pharmaceutical products as well as in the assessment of pharmaceutical equivalence and stability study of drug products.展开更多
Atmospheric reentry vehicles and planetary probes fly through the atmosphere at hypervelocity speed. At such speed, there is a significant proportion of heat load to the vehicle surface due to radiative heating. Accur...Atmospheric reentry vehicles and planetary probes fly through the atmosphere at hypervelocity speed. At such speed, there is a significant proportion of heat load to the vehicle surface due to radiative heating. Accurate prediction needs a good knowledge of the radiation spectrum properties. In this paper, a high-speed camera and spectrograph coupled to an intensified charge-coupled device have bee n impleme nted to inv estigate the rad i at io n flow over a semi-cylinder model. The experiments were carried out in the JF16 expansi on timnel with secondary shock velocity of 7.9 km·s^-1. Results show that the emissio n spectrum comprises several atomic lines and molecular band systems. We give detailed data of the radiation spectrum, shock shape, shock detached distance and radiation intensity varying with space and wavelength. This valuable experimental dataset will be helpful to validate computational fluid dynamics codes and radiation models, which equates to increased prediction accuracy of radiation heating. Also, some suggestions for spectral measurement in hypervelocity flow field were list in the end.展开更多
This study endeavors to deal with the least square spectral analysis on the time series, to find present significant frequencies, to analyze 40 tide components using harmonic methods and to show relationship between d...This study endeavors to deal with the least square spectral analysis on the time series, to find present significant frequencies, to analyze 40 tide components using harmonic methods and to show relationship between discovered frequencies and 40 components of tide. For the purpose of collecting data of altimetry satellites of Topex/Poseidon (T/P), Jason 1, Jason 2 and coastal tide gauges of Bandar Anzali, Noshahr, and Nekah were utilized. In this time series formed by cross over points of altimetry satellite and then using least square spectral analysis on time series derived from altimetry satellite and coastal tide gauges the significant components were found and annual, biannual, and monthly components were discovered. Then, analysis of 40 tide components was conducted using harmonic method to find the amplitude and phase. It represented that solar annual (Sa) plays the most significant role on Caspian Sea corresponded to the least square spectral analysis of the time series. The results shows that the annual (Sa) and semi-annual Solar (Ssa) constituents on all of the ports listed have the highest amplitude in comparison with the other constituents which are respectively 16 cm, 18 cm and 15 cm for annual constituent and 2.8 cm, 5.4 cm and 3.7 cm for semi-annual constituent.展开更多
The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of eac...The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of each subcell are obtained using different excitation lasers. The PL intensity has a fast degradation after irradiation, and decreases as the displacement damage dose increases. Furthermore, the normalized PL intensity varying with the displacement damage dose is analyzed in detail, and then the lifetime damage coefficients of the recombination centers for GaInP top-cell, GaAs mid-cell and Ge bottom-cell of the triple-junction solar cells are determined from the PL radiative efficiency.展开更多
To ensure the performance of the optical system, the machining accuracy of lens with long focal lengths is required to ensure the image quality. A new method for lens transmission wavefront power spectral density (PSD...To ensure the performance of the optical system, the machining accuracy of lens with long focal lengths is required to ensure the image quality. A new method for lens transmission wavefront power spectral density (PSD) in mid-frequency domain measurement using binary phase computer-generated hologram (CGH) is presented. This technique is widely applicable and is particularly useful for measuring large-size lenses with long focal lengths. A comparison experiment of the CGH measurement with results from a Fizeau sphere interferometry method is carried out to verify the accuracy and convenience of the measurement. Furthermore, measurement uncertainty due to CGH fabrication process is analysed. Analysis of the CGH test showed the overall accuracy of less than 1 nm RMS for a sphere lens with over 30 m focal length and Φ410 mm clear aperture. CGH can provide reference spheres with high precision, in the meantime greatly shorten air space, thus reducing the effect of vibration and air turbulence, therefore is of great importance for lens transmission wavefront PSD measurement. The realization of high precision, high efficiency and nondestructive testing of long focal-lens wavefront PSD ensure the ultra-precision and certainty level of machining, hence improving the comprehensive performance of the optical system.展开更多
This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fix...This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fixed spectrum allocation policy, and the spectrum occupancy varies dramatically in terms of time and space. These results provide basis for the development of next generation wireless communication technologies such as Cognitive Radio (CR).展开更多
A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconductin...A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further展开更多
A new terahertz dispersive device designed for single-shot spectral measurements of broadband terahertz pulses is proposed. With two-dimensional quasi-randomly distributed element design, the device exhibits approxima...A new terahertz dispersive device designed for single-shot spectral measurements of broadband terahertz pulses is proposed. With two-dimensional quasi-randomly distributed element design, the device exhibits approximately the dispersive property of single-order diffraction in far field. Its far-field diffraction pattern is experimentally verified employing a continuous terahertz source centered at 2.52 THz and a pyroelectric focal-plane-array camera, which is in good agreement with the numerical result. The device provides a new approach for direct single-shot spectral measurements of broadband terahertz waves.展开更多
The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is pe...The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.展开更多
The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fa...The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fast neutron fluxes were found to be 2.960 × 10~6 and6.186 × 10~7 n/cm^2 s, respectively. This was done to verify the modeling results for the optimum moderator thickness needed to maximize the thermal neutron flux. The optimum moderator thickness was found to be between 3.5 and4 cm. The present data were compared with the detailed MCNP model-based calculation performed in earlier work to simulate the generator.展开更多
In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the trackin...In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the tracking rate can not meet this requirement.The sampling of fixed velocity can meet the requirement of particulate matter sampling on gas collection volume at low velocity.Through the comparison of two different methods for the determination of particulate matter in waste gas under the low flow velocity of flue gas,it was found that there were some differences between the fixed velocity measurement and the constant velocity measurement.The results showed that measurement result of the fixed velocity was higher than that of constant velocity measurement under low velocity.At the same time,the deviation of fixed velocity measurement was not obvious under different low velocity.展开更多
One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between...One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between bilateral canines (BB’), the bimentalbreite (CC’) and the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’). The length of mandibular body (AF) was strongly correlated with the vertical distance from bigonial breadth to the breadth of bilateral canines (BB’F), to the bimentalbreite (CC’F) and to the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’F). Six regressive equations were established. Significance of these equations was discussed.展开更多
With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle,...With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.展开更多
基金supported by the National Key R&D Program(No.2022YFA1602201)。
文摘This paper presents a new technique for measuring the bunch length of a high-energy electron beam at a bunch-by-bunch rate in storage rings.This technique uses the time–frequency-domain joint analysis of the bunch signal to obtain bunch-by-bunch and turn-by-turn longitudinal parameters,such as bunch length and synchronous phase.The bunch signal is obtained using a button electrode with a bandwidth of several gigahertz.The data acquisition device was a high-speed digital oscilloscope with a sampling rate of more than 10 GS/s,and the single-shot sampling data buffer covered thousands of turns.The bunch-length and synchronous phase information were extracted via offline calculations using Python scripts.The calibration coefficient of the system was determined using a commercial streak camera.Moreover,this technique was tested on two different storage rings and successfully captured various longitudinal transient processes during the harmonic cavity debugging process at the Shanghai Synchrotron Radiation Facility(SSRF),and longitudinal instabilities were observed during the single-bunch accumulation process at Hefei Light Source(HLS).For Gaussian-distribution bunches,the uncertainty of the bunch phase obtained using this technique was better than 0.2 ps,and the bunch-length uncertainty was better than 1 ps.The dynamic range exceeded 10 ms.This technology is a powerful and versatile beam diagnostic tool that can be conveniently deployed in high-energy electron storage rings.
文摘Human physiological(biological)systems function in such a way that their complexity requires mathematical analysis.The functioning of the brain,heart and other parts are so complex to be easily comprehended.Under conditions of rest or work,the temporal distances of successive heartbeats are subject to fluctuations,thereby forming the basis of Heart Rate Variability(HRV).In normal conditions,the human is persistently exposed to highly changing and dynamic situational demands.With these demands in mind,HRV can,therefore,be considered as the human organism’s ability to cope with and adapt to continuous situational requirements,both physiologically and emotionally.Fast Fourier Transform(FFT)is used in various physiological signal processing,such as heart rate variability.FFT allows a spectral analysis of HRV and is great help in HRV analysis and interpretation.
基金Project supported by the Shanghai Science and Technology Innovation Action(Grant No.22dz1208700).
文摘Pulse echo accumulation is commonly employed in coherent Doppler wind LiDAR(light detection and ranging)under the assumption of steady wind.Here,the measured spectral data are analyzed in the time dimension and frequency dimension to cope with the temporal wind shear and achieve the optimal accumulation time.A hardware-efficient algorithm combining the interpolation and cross-correlation is used to enhance the wind retrieval accuracy by reducing the frequency sampling interval and then reduce the spectral width calculation error.Moreover,the temporal broadening effect and spatial broadening effect are decoupled according to the strategy we developed.
文摘The assessment of the measurement error status of online Capacitor Voltage Transformers (CVT) within the power grid is of profound significance to the equitable trade of electric energy and the secure operation of the power grid. This paper advances an online CVT error state evaluation method, anchored in the in-phase relationship and outlier detection. Initially, this method leverages the in-phase relationship to obviate the influence of primary side fluctuations in the grid on assessment accuracy. Subsequently, Principal Component Analysis (PCA) is employed to meticulously disentangle the error change information inherent in the CVT from the measured values and to compute statistics that delineate the error state. Finally, the Local Outlier Factor (LOF) is deployed to discern outliers in the statistics, with thresholds serving to appraise the CVT error state. Experimental results incontrovertibly demonstrate the efficacy of this method, showcasing its prowess in effecting online tracking of CVT error changes and conducting error state assessments. The discernible enhancements in reliability, accuracy, and sensitivity are manifest, with the assessment accuracy reaching an exemplary 0.01%.
文摘Gyrnnarchus niloticus swims by undulations of a long-based dorsal fin, while its body axis is in many cases held straight during swimming. This paper provides a brief relevant introduction to Gyrnnarchus niloticus, which belongs to the African freshwater electric eels but can inspire our bionic interests in propulsion besides its abilities in electric sensing. A special larva of Gyrnnarchus niloticus was morphologically measured by photographing it with a piece of scale-calibrated paper as the background. Then we analyzed the data by a CFD-aided approach. Detailed flow patterns around the larva and a NACA0012 hydrofoil were respectively calculated and visualized at the Reynolds number of 7350 or so. The results show that the profile of Gyrnnarchus niloticus is well streamlined.
基金supported by the Industrial Infrastructure Program through The Korea Institute for Advancement of Technology(KIAT) Grant funded by the Korea government Ministry of Trade,Industry and Energy(Grant N0000502)
文摘The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.
基金supported by Fundacao de Apoio à Pesquisa do Estado de Sao Paulo(FAPESP)
文摘The measurement uncertainty provides complete information about an analytical result. This is very important because several decisions of compliance or non-compliance are based on analytical results in pharmaceutical industries. The aim of this work was to evaluate and discuss the estimation of uncertainty in pharmaceutical analysis. The uncertainty is a useful tool in the assessment of compliance or non-compliance of in-process and final pharmaceutical products as well as in the assessment of pharmaceutical equivalence and stability study of drug products.
基金the National NaturalScience Foundation of China (Grants 11602275. 11672308, 11672312.and 11532014.).
文摘Atmospheric reentry vehicles and planetary probes fly through the atmosphere at hypervelocity speed. At such speed, there is a significant proportion of heat load to the vehicle surface due to radiative heating. Accurate prediction needs a good knowledge of the radiation spectrum properties. In this paper, a high-speed camera and spectrograph coupled to an intensified charge-coupled device have bee n impleme nted to inv estigate the rad i at io n flow over a semi-cylinder model. The experiments were carried out in the JF16 expansi on timnel with secondary shock velocity of 7.9 km·s^-1. Results show that the emissio n spectrum comprises several atomic lines and molecular band systems. We give detailed data of the radiation spectrum, shock shape, shock detached distance and radiation intensity varying with space and wavelength. This valuable experimental dataset will be helpful to validate computational fluid dynamics codes and radiation models, which equates to increased prediction accuracy of radiation heating. Also, some suggestions for spectral measurement in hypervelocity flow field were list in the end.
文摘This study endeavors to deal with the least square spectral analysis on the time series, to find present significant frequencies, to analyze 40 tide components using harmonic methods and to show relationship between discovered frequencies and 40 components of tide. For the purpose of collecting data of altimetry satellites of Topex/Poseidon (T/P), Jason 1, Jason 2 and coastal tide gauges of Bandar Anzali, Noshahr, and Nekah were utilized. In this time series formed by cross over points of altimetry satellite and then using least square spectral analysis on time series derived from altimetry satellite and coastal tide gauges the significant components were found and annual, biannual, and monthly components were discovered. Then, analysis of 40 tide components was conducted using harmonic method to find the amplitude and phase. It represented that solar annual (Sa) plays the most significant role on Caspian Sea corresponded to the least square spectral analysis of the time series. The results shows that the annual (Sa) and semi-annual Solar (Ssa) constituents on all of the ports listed have the highest amplitude in comparison with the other constituents which are respectively 16 cm, 18 cm and 15 cm for annual constituent and 2.8 cm, 5.4 cm and 3.7 cm for semi-annual constituent.
基金Supported by the National Natural Science Foundation of China under Grant Nos 10675023,11075018,11375028 and 11675020the Specialized Research Fund for the Doctoral Program of Higher Education under Grant No 20120003110011
文摘The radiation damage of three individual subcells for GalnP/GaAs//Ge triple-junction solar cells irradiated with electrons and protons is investigated using photoluminescence (PL) measurements. The PL spectra of each subcell are obtained using different excitation lasers. The PL intensity has a fast degradation after irradiation, and decreases as the displacement damage dose increases. Furthermore, the normalized PL intensity varying with the displacement damage dose is analyzed in detail, and then the lifetime damage coefficients of the recombination centers for GaInP top-cell, GaAs mid-cell and Ge bottom-cell of the triple-junction solar cells are determined from the PL radiative efficiency.
文摘To ensure the performance of the optical system, the machining accuracy of lens with long focal lengths is required to ensure the image quality. A new method for lens transmission wavefront power spectral density (PSD) in mid-frequency domain measurement using binary phase computer-generated hologram (CGH) is presented. This technique is widely applicable and is particularly useful for measuring large-size lenses with long focal lengths. A comparison experiment of the CGH measurement with results from a Fizeau sphere interferometry method is carried out to verify the accuracy and convenience of the measurement. Furthermore, measurement uncertainty due to CGH fabrication process is analysed. Analysis of the CGH test showed the overall accuracy of less than 1 nm RMS for a sphere lens with over 30 m focal length and Φ410 mm clear aperture. CGH can provide reference spheres with high precision, in the meantime greatly shorten air space, thus reducing the effect of vibration and air turbulence, therefore is of great importance for lens transmission wavefront PSD measurement. The realization of high precision, high efficiency and nondestructive testing of long focal-lens wavefront PSD ensure the ultra-precision and certainty level of machining, hence improving the comprehensive performance of the optical system.
文摘This paper analyzes current spectrum utilization from all aspects based on related methods of spectrum measurement. The measurement results show that some spectrum resources are not used effectively due to current fixed spectrum allocation policy, and the spectrum occupancy varies dramatically in terms of time and space. These results provide basis for the development of next generation wireless communication technologies such as Cognitive Radio (CR).
基金Supported by the National Natural Science Foundation of China under Grant No 11302225the China Postdoctoral Science Foundation under Grant Nos 2014M560820 and 2015T81071
文摘A fully superconducting electron cyclotron resonance (ECR) ion source (SECRAL ID is currently being built in the Institute of Modern Physics, Chinese Academy of Sciences. Its key components are three superconducting solenoids (Nb-Ti/Cu) and six superconducting sextupoles (Nb-Ti/Cu). Different from the conventional supercon- ducting ECR magnetic structure, the SEC17AL Ⅱ includes three superconducting solenoid coils' that are located inside the superconducting sextupoles. The SECRAL Ⅱ can significantly reduce the interaction forces between the sextupole and the solenoids, and the magnets can also be more compact in size. For this multi-component SECRAL Ⅱ generating its self field of -8 T and being often exposed to the high self field, the mechanical analysis has become the main issue to keep their stress at 〈200 MPa on coils. The analytical and experimental results in mechanics are presented in the SECRAL Ⅱ structure. To improve the accuracy and efficiency of analysis, according to the composite rule of micromechanics, the equivalent uniform windings are used to simulate the epoxy-impregnated Nb-Ti/Cu coils. In addition, using low temperature strain gauges and a wireless fast strain acquisition system, a fundamental experiment on the based on our analysis, the stresses and deformations optimized. strains developments of a sextupole is reported. Finally, for its assembly of each SECRAL Ⅱ coil will be further
基金Project supported by the Foundation of Science and Technology Development of China Academy of Engineering Physics(Grant No.2011B0102023)the Foundation of Plasma Physics Laboratory(Grant No.9140C680304110C6806)
文摘A new terahertz dispersive device designed for single-shot spectral measurements of broadband terahertz pulses is proposed. With two-dimensional quasi-randomly distributed element design, the device exhibits approximately the dispersive property of single-order diffraction in far field. Its far-field diffraction pattern is experimentally verified employing a continuous terahertz source centered at 2.52 THz and a pyroelectric focal-plane-array camera, which is in good agreement with the numerical result. The device provides a new approach for direct single-shot spectral measurements of broadband terahertz waves.
文摘The paper presents a number of signal processing approaches for the spectral interferometric interrogation of extrinsic Fabry-Perot interferometers(EFPIs). The analysis of attainable microdisplacement resolution is performed and the analytical equations describing the dependence of resolution on parameters of the interrogation setup are derived. The efficiency of the proposed signal processing approaches and the validity of analytical derivations are supported by experiments. The proposed approaches allow the interrogation of up to four multiplexed sensors with attained resolution between 30 pm and 80 pm, up to three times improvement of microdisplacement resolution of a single sensor by means of using the reference interferometer and noisecompensating approach, and ability to register signals with frequencies up to 1 kHz in the case of 1 Hz spectrum acquisition rate. The proposed approaches can be used for various applications, including biomedical, industrial inspection, and others, amongst the microdisplacement measurement.
文摘The fast and maximum thermal neutron fluxes from the DD-109 neutron generator at the University of Sharjah were experimentally measured by the activation technique using different neutron reactions. The thermal and fast neutron fluxes were found to be 2.960 × 10~6 and6.186 × 10~7 n/cm^2 s, respectively. This was done to verify the modeling results for the optimum moderator thickness needed to maximize the thermal neutron flux. The optimum moderator thickness was found to be between 3.5 and4 cm. The present data were compared with the detailed MCNP model-based calculation performed in earlier work to simulate the generator.
基金Supported by the Shihezi Science and Technology Plan(2018JZ08)the National Natural Science Foundation of China(21667026)
文摘In the current waste gas sampling of fixed source,it is required that deviation of tracking rate of constant velocity sampling should not be more than 10%.When flow rate of the waste gas is less than 5 m/s,the tracking rate can not meet this requirement.The sampling of fixed velocity can meet the requirement of particulate matter sampling on gas collection volume at low velocity.Through the comparison of two different methods for the determination of particulate matter in waste gas under the low flow velocity of flue gas,it was found that there were some differences between the fixed velocity measurement and the constant velocity measurement.The results showed that measurement result of the fixed velocity was higher than that of constant velocity measurement under low velocity.At the same time,the deviation of fixed velocity measurement was not obvious under different low velocity.
文摘One hundred fifty three mandibles of adult Chinese cadavers were measured. The acquired data were correlatively analysed with computer. It was found that bigonial breadth (EE’) was correlated with the breadth between bilateral canines (BB’), the bimentalbreite (CC’) and the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’). The length of mandibular body (AF) was strongly correlated with the vertical distance from bigonial breadth to the breadth of bilateral canines (BB’F), to the bimentalbreite (CC’F) and to the breadth between right and left vertex of alveolar ridge between the first and the second molar (DD’F). Six regressive equations were established. Significance of these equations was discussed.
文摘With determination micro-Fe by 1, 10-phenanthroline spectrophotometry for example, they are systematically introduced the combinatorial measurement and regression analysis method application about metheodic principle, operation step and data processing in the instrumental analysis, including: calibration curve best linear equation is set up, measurand best linear equation is set up, and calculation of best value of a concentration. The results showed that mean of thrice determination , s = 0 μg/mL, RSD = 0. Results of preliminary application are simply introduced in the basic instrumental analysis for atomic absorption spectrophotometry, ion-selective electrodes, coulometry and polarographic analysis and are contrasted to results of normal measurements.