期刊文献+
共找到5,881篇文章
< 1 2 250 >
每页显示 20 50 100
Long-term operation optimization of circulating cooling water systems under fouling conditions
1
作者 Jiarui Liang Yong Tian +3 位作者 Shutong Yang Yong Wang Ruiqi Yin Yufei Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第1期255-267,共13页
Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optim... Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optimization of CCWS often prioritizes short-term flow velocity optimization for minimizing power consumption,without considering fouling.However,low flow velocity promotes fouling.Therefore,it's crucial to balance fouling and energy/water conservation for optimal CCWS long-term operation.This study proposes a mixed-integer nonlinear programming(MINLP)model to achieve this goal.The model considers fouling in the pipeline,dynamic concentration cycle,and variable frequency drive to optimize the synergy between heat transfer,pressure drop,and fouling.By optimizing the concentration cycle of the CCWS,water conservation and fouling control can be achieved.The model can obtain the optimal operating parameters for different operation intervals,including the number of pumps,frequency,and valve local resistance coefficient.Sensitivity experiments on cycle and environmental temperature reveal that as the cycle increases,the marginal benefits of energy/water conservation decrease.In periods with minimal impact on fouling rate,energy/water conservation can be achieved by increasing the cycle while maintaining a low fouling rate.Overall,the proposed model has significant energy/water saving effects and can comprehensively optimize the CCWS through its incorporation of fouling and cycle optimization. 展开更多
关键词 Computer simulation Circulating water system fouling Concentration cycle OPTIMIZATION Variable frequency drive
下载PDF
Analysis of influence of heat exchangerfouling on heat transfer performancebased on thermal fluid coupling 被引量:1
2
作者 HUANG Si MURAD Tariq +2 位作者 NIU Qifeng LIN Guangtang CHEN Jianxun 《排灌机械工程学报》 CSCD 北大核心 2023年第7期695-700,共6页
A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid do... A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact. 展开更多
关键词 shell-tube heat exchanger thermal fluid coupling fouling thermal resistance heat transfer analysis
下载PDF
Multivariable identification of membrane fouling based on compacted cascade neural network
3
作者 Kun Ren Zheng Jiao +1 位作者 Xiaolong Wu Honggui Han 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第1期37-45,共9页
The membrane fouling phenomenon,reflected with various fouling characterization in the membrane bioreactor(MBR)process,is so complicated to distinguish.This paper proposes a multivariable identification model(MIM)base... The membrane fouling phenomenon,reflected with various fouling characterization in the membrane bioreactor(MBR)process,is so complicated to distinguish.This paper proposes a multivariable identification model(MIM)based on a compacted cascade neural network to identify membrane fouling accurately.Firstly,a multivariable model is proposed to calculate multiple indicators of membrane fouling using a cascade neural network,which could avoid the interference of the overlap inputs.Secondly,an unsupervised pretraining algorithm was developed with periodic information of membrane fouling to obtain the compact structure of MIM.Thirdly,a hierarchical learning algorithm was proposed to update the parameters of MIM for improving the identification accuracy online.Finally,the proposed model was tested in real plants to evaluate its efficiency and effectiveness.Experimental results have verified the benefits of the proposed method. 展开更多
关键词 Membrane fouling PERMEABILITY Cascade neural networks Model PREDICTION
下载PDF
Seasonal Variability of Biofouling Community Structure in the Gulf of Mannar,Southeast Coast of India:A Multivariate Approach
4
作者 MARIMUTHU Nithyanandam WILSON James Jerald KUMARAGURU Arumugam Kuppuswamy 《Journal of Ocean University of China》 SCIE CAS CSCD 2023年第3期766-776,共11页
In this research,an Underwater Biofouling Panel(UWBFP)system was erected for the qualitative and quantitative estimation of macro fouling organisms in the Gulf of Mannar.Forty-four biofoulers were identified from four... In this research,an Underwater Biofouling Panel(UWBFP)system was erected for the qualitative and quantitative estimation of macro fouling organisms in the Gulf of Mannar.Forty-four biofoulers were identified from four types of selected test panels.Among these biofoulers,Amphibalanus amphitrite(Darwin,1854)was the dominant one.The concrete panel encouraged the highest barnacle density compared to the other panels.Three series of test panels were used to assess the seasonal density of biofouling communities.The overall variation in barnacle count in the seaward and shoreward sides of all these three series were tested.They were found to be significantly different from each other.The greater variations in the barnacle density observed in this study in A-series of test panels could be due to the lack of or absence of other foulers to compete within the fortnight.The Shannon-Wiener species diversity index showed the highest diversity in wood substratum among the three series with greater accumulation of different types of fouling organisms.Multivariate analyses were also performed to understand the seasonal variation as well as the settlement pattern on the different directions of test panels based on validated data.PCA showed a strong variability(PC1 between 70.8%and 98.6%variance)between the directions of the panels in connection with barnacle density.The shade plot and CAP analysis segregated the short-term A-series test panels from the long-term(B-and C-series)test panels.Hence,the output was helpful in understanding the recruitment status of various faunal resources involved in the biofouling processes. 展开更多
关键词 BIOfouling BARNACLE hard fouler multivariate analysis fouling biomass Gulf of Mannar
下载PDF
Effect of Fouling in Daya Bay Scallop chlamys nobilis (reeve) Cultivation:Food Competition and Nutrient Release 被引量:3
5
作者 苏振霞 肖辉 +1 位作者 黄良民 严岩 《Marine Science Bulletin》 CAS 2009年第2期37-44,共8页
Biofouling is an important factor that affects bivalve farming industry. Fouling organisms may reduce growth and survival rate of the cultured species. Fouler are often filter feeders, so they are potential competitor... Biofouling is an important factor that affects bivalve farming industry. Fouling organisms may reduce growth and survival rate of the cultured species. Fouler are often filter feeders, so they are potential competitors for food resource with the cultured species. The present study was conducted to measure the impact of fouling on food uptake and nutrient release in April, 2006 in Daya Bay near Guangzhou, China. Results showed that fouling organisms had significant effect on food uptake and nutrient release. The chlorophyll a uptake rate of fouled scallops was 7.53 / Lh ±1.416 / Lh in April, significantly higher than those of cleaned scallops, Le., 4.23 / Lh±2.744 / Lh. The consumption of total particulate matter by fouled scallops in April was 5.52 / Lh± 0.818 / Lh; the corresponding results for cleaned scallops are 2.49 / Lh ±0.614 / Lh Fouling increased ammonia release significantly. The ammonia release rate of fouled scallops was 33.81/Lh ±7.699 / Lh in April, while cleaned scallops released 2.46 / Lh ±0.511 / Lh ammonia. Phosphate uptake of fouled scallops was 2.01± 0.699 / Lh and cleaned scallops released phosphate 6.01 / Lh + 0.876 / Lh in April. There was not significant difference in nitrate consumption between fouled and cleaned scallops. According to the phytoplankton classification of input and output water samples, fouled scallops filtered more phytoplankton species than cleaned scallops. Therefore, this study showed that fouling contributed much to phytoplankton depletion and concentration increase of ammonia in water. 展开更多
关键词 SCALLOP Chlamys nobilis fouling food uptake nutrient release
下载PDF
Nontoxic Marine Anti-fouling Coating Containing Capsaicin 被引量:2
6
作者 史航 王鲁民 《Marine Science Bulletin》 CAS 2006年第1期92-96,共5页
This paper summarizes a nontoxic Anti-fouling coating utilizing capsaicin as an anti-fouling agent. The capsaicin constituent used in the coating has a rating from about 100 000 to about 1 500 000 Scoville Heat Units.... This paper summarizes a nontoxic Anti-fouling coating utilizing capsaicin as an anti-fouling agent. The capsaicin constituent used in the coating has a rating from about 100 000 to about 1 500 000 Scoville Heat Units. The capsaicin is mixed with a silicon dioxide and then solubilized into a free-flowing homogeneous liquid oleoresin composition by adding a solvent to increase solubility and facilitate mixing. The oleoresin capsaicin liquid solution is mixed with a suitable corrosion resistant epoxy resin, which is then mixed with a hardening catalyst and applied to the surface to be treated. 展开更多
关键词 antifouling coating CAPSAICIN nontoxic fishnet marine fouling organism
下载PDF
Dielectric Analysis of Dynamic Fouling Behavior on Surface of Polyethersulfone Composite Ultrafiltration Membrane
7
作者 罗明良 温庆志 +1 位作者 刘佳林 刘洪见 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2010年第2期241-248,I0002,共9页
A dielectric analysis model for the fouling layer on the polyethersulfone composite ultrafiltration (UF) membrane and solution system, which consists of the solution, concentration polarization layer (CPL), and ca... A dielectric analysis model for the fouling layer on the polyethersulfone composite ultrafiltration (UF) membrane and solution system, which consists of the solution, concentration polarization layer (CPL), and cake layer, was established by virtue of the interfacial polarization and the electrostatic field theory. The effect of some important parameters, such as the depth, conductivity of CPL, and cake layer, on the dielectric spectroscopy (or dielectric relaxation properties) of the UF system was discussed by the parameter sensitivity analysis and the dielectric measurement. The simulations indicate that the CPL can be created rapidly and the cake layer formation is the dynamic balance process of growth and erosion in the process of UF. The key factor affecting on the dielectric spectrum of UF system is the electrical properties of the CPL and the cake layer. In comparison to the results of dielectric measurement, the simulations indicate that the model proposed in this work is valid and reliable to some degree for describing and explaining the dielectric relaxation phenomenon in UF system. It is very important to further understand the fouling behavior of membrane surface and optimize the controlling techniques of membrane fouling in the process of UF. 展开更多
关键词 Interfacial polarization Cake layer Dynamic fouling Ultrafiltration Dielec-tric relaxation
下载PDF
Effect of coagulation pretreatment on the fouling of ultrafiltration membrane 被引量:48
8
作者 DONG Bing-zhi CHEN Yan GAO Nai-yun FAN Jin-chu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第3期278-283,共6页
The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM).... The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM). A relatively higher molecular weight (MW) of hydrophobic compounds was responsible for a rapid decline in the ultrafiltration flux. Coagulation could effectively remove the hydrophobic organics, resulting in the increase of flux. It was found that a lower MW of neutral hydrophilic compounds, which could remove inadequately by coagulation, was responsible for the slow declining flux. The fluxes in the filtration of coagulated water and supernatant water were compared and the results showed that a lower MW of neutral hydrophilic compounds remained in the supernatant water after coagulation could be rejected by a membrane, resulting in fouling. It was also found that the coagulated flocs could absorb neutral hydrophilic compounds effectively. Therefore, with the coagulated flocs formed on the membrane surface, the flux decline could be improved. 展开更多
关键词 drinking water treatment ULTRAFILTRATION COAGULATION fouling
下载PDF
Comparison of membrane fouling during short-term filtration of aerobic granular sludge and activated sludge 被引量:18
9
作者 ZHOU Jun YANG Feng-lin MENG Fan-gang AN Peng WANG Di 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2007年第11期1281-1286,共6页
Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activa... Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activated sludge system were investigated. The membrane foulants was also characterized by Fourier transform infrared (FTIR) spectroscopy technique. The results showed that the aerobic granular sludge had excellent denitrification ability; the removal efficiency of TN could reach 90%. The aerobic granular sludge could alleviate membrane fouling effectively. The steady membrane flux of aerobic granular sludge was twice as much as that of activated sludge system. In addition, it was found that the aerobic granular sludge could result in severe membrane pore-blocking, however, the activated sludge could cause severe cake fouling. The major components of the foulants were identified as comprising of proteins and polysaccharide materials. 展开更多
关键词 membrane bioreactor membrane fouling pore-blocking cake layer resistance aerobic granular sludge
下载PDF
Mechanism of calcium mitigating membrane fouling in submerged membrane bioreactors 被引量:16
10
作者 ZHANG Hanmin, XIA Jie, YANG Yang, WANG Zixing, YANG FenglinKey Laboratory of Industrial Ecology and Environmental Engineering, MOE, School of Environmental and Biological Science and Technology, Dalian University of Technology, Dalian 116024, China. 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2009年第8期1066-1073,共8页
Two parallel membrane bioreactors (MBRs) were operated under different calcium dosages (168.5, 27 mg/L) to gain a better understanding of the mechanism of retarding membrane fouling by adding calcium. The results ... Two parallel membrane bioreactors (MBRs) were operated under different calcium dosages (168.5, 27 mg/L) to gain a better understanding of the mechanism of retarding membrane fouling by adding calcium. The results showed that the particle size of sludge flocs increased and the particle size distribution tended to be narrow at the optimum dosage (168.5 mg/L). Calcium was effective in decreasing loosely bound extracellular polymeric substances (LB-EPS) in microbial flocs and soluble microbial products (SMP) in the supernatant at the dosage of 168.5 mg/L by strengthening the neutralization and bridging of EPS with flocs. Furthermore, the amount of CODs and CODc decreased in both the mixed liquor and the fouling cake layer on the membrane surface. In order to compare the filtration characteristics of cake layers from the MBRs with the two calcium dosages, the specific cake resistance and the compressibility coefficient were measured. The specific cake resistance from the MBR with optimum dosage (168.5 mg/L) was distinctly lower than that with low dosage (27 mg/L). The compressibility coefficient of the cake layers under two dosages were respectively attained as 0.65, 0.91. Scanning electron microscopy (SEM) and three-dimensional confocal scanning laser microscope analysis (CLSM) images were utilized to observe the gel layer directly. 展开更多
关键词 CALCIUM membrane fouling loosely bound extracellular polymeric substances (LB-EPS) compressibility coefficient
下载PDF
Lowering ash slagging and fouling tendency of high-alkali coal by hydrothermal pretreatment 被引量:5
11
作者 Mingshun Yang Qiang Xie +3 位作者 Xin Wang He Dong Hao Zhang Chunqi Li 《International Journal of Mining Science and Technology》 SCIE EI CSCD 2019年第3期521-525,共5页
High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave a... High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave at 300 -C for 1 h,and the treated coals were analyzed,along with the oxygen-containing functional groups determined by Fourier transform infrared spectrometer(FT-IR).Then the alkali species and other components in the coal ash were quantified by X-ray fluorescence(XRF)for evaluating the ash slagging and fouling tendency.Apart from this,FactSage was adopted to simulate the occurrence and transformation of alkali species during coal thermal conversion ending at various temperatures.The findings indicate that the treated coals are superior to the parent ones in terms of certain remarkable changes via HTP.The moisture,oxygen and sulfur of the hydrothermally treated coals decline obviously,while the calorific value rises sharply.HTP could reduce the alkali species to less than 2%(%,by weight,equivalent to Na2O in dry ash),with a maximum removal ratio of 88.9%,lowering the ash slagging and fouling tendency.The proposed mechanism of HTP was that the alkali species in coal matrix became released due to the breakage of the coal functional groups and micropores during HTP. 展开更多
关键词 HYDROTHERMAL PRETREATMENT High-alkali COAL ASH SLAGGING and fouling tendency Lowering FactSage
下载PDF
Ultrafiltration with in-line coagulation for the removal of natural humic acid and membrane fouling mechanism 被引量:10
12
作者 WANG Jin WANG Xiao-chang 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2006年第5期880-884,共5页
Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV... Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV254 removals by the UF with in-line coagulation at pH 7 were increased from 28% to 53% and 40% to 78% in comparison with direct UF treatment respectively. At the same time, the analysis of high performance liquid chromatography showed that UF with coagulation had significant improvement of removal of humic acid with molecular weights less than 6000 Da in particular. Compared to direct UF, the in-line coagulation UF also kept more constant permeate flux and very slight increase oftransmembrane pressure during a filtration circle. Two typical membrane fouling models were used by inducing two coefficients Kc and Kp corresponding to cake filtration model and pore narrowing model respectively. It was found that membrane fouling by pore-narrowing effect was effectively alleviated and that by cake-filtration was much decreased by in-line coagulation. Under the condition of coagulation prior to ultrafiltration at pH 7, the cake layer formed on the membrane surface became thicker, but the membrane filtration resistance was lower than that at pH 5 with the extension of operation time. 展开更多
关键词 natural humic acid ultrafiltration (UF) in-line coagulation high performance liquid chromatography (HPLC) membrane fouling
下载PDF
Selective swelling of polysulfone/poly(ethylene glycol) block copolymer towards fouling-resistant ultrafiltration membranes 被引量:5
13
作者 Hao Yang Jiemei Zhou +2 位作者 Zhaogen Wang Xiansong Shi Yong Wang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第1期98-103,共6页
Fouling resistance of ultrafiltration(UF) membranes is critical for their long-term usages in terms of stable performance, so convenient approaches to prepare fouling-resistant membranes are always anticipated. Herein... Fouling resistance of ultrafiltration(UF) membranes is critical for their long-term usages in terms of stable performance, so convenient approaches to prepare fouling-resistant membranes are always anticipated. Herein, we demonstrate the facile fabrication of antifouling polysulfone-block-poly(ethylene glycol)(PSF-b-PEG, SFEG)composite membranes. SFEG layer was coated onto macroporous supports and cavitated by immerging them in acetone/n-propanol following the mechanism of selective swelling induced pore generation. Thus-produced SFEG membranes possessed high permeance and excellent mechanical strength. Meanwhile, the structures and separation performances of the SFEG layers can be continuously tuned through simply changing swelling durations. More importantly, the hydrophilic PEG chains were spontaneously enriched onto the pore walls through swelling treatment, endowing intrinsic antifouling property to the SFEG membranes. Bovine serum albumin(BSA)/humic acid(HA) fouling tests proved the prominent fouling resistance of SFEG membranes, and the fouling resistance is expected to be long-standing because of the firm connection between PEG chains and PSF matrix by covalent bonding. 展开更多
关键词 Polysulfone-block-poly(ethylene glycol) Block copolymer fouling resistance SELECTIVE SWELLING ULTRAFILTRATION membrane
下载PDF
Fouling of WO3 nanoparticle-incorporated PSf membranes in ultrafiltration of landfill leachate and dairy a combined wastewaters: An investigation using model 被引量:4
14
作者 Majid Peyravi Mohsen Jahanshahi Soodabeh Khalili 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2017年第6期741-751,共11页
As fouling has always been a major drawback of membrane technology, qualitative and quantitative understanding of membrane fouling mechanisms therefore becomes vital in order to help push membrane separation technolog... As fouling has always been a major drawback of membrane technology, qualitative and quantitative understanding of membrane fouling mechanisms therefore becomes vital in order to help push membrane separation technologies forward. In this study, firstly, self-cleaning Polysulfone(PSf) membranes were synthesized by incorporation of WO_3nanoparticles(0–2 wt%) and subsequent UV irradiation for efficient ultrafiltration(UF)of landfill leachate and dairy wastewater. The membrane surface properties were characterized by scanning electron microscopy(SEM) and contact angle analysis. It was found that UV-irradiated membranes exhibited higher percent COD removals due to the hydrophilicity and photocatalytic properties of nano-WO_3. Subsequently, in order to analyze the fouling behavior of the membranes, a set of experimental data from cross-flow ultrafiltration of municipal landfill leachate and industrial dairy wastewater at 25 °C was obtained. A new model of membrane fouling was proposed based on a resistance in series concept and was fitted well with all experimental data sets.Almost all relative errors of prediction provided by the proposed model were less than 2.5%. In addition, it was revealed that this newly-developed model exhibited smooth transition between the common successive twostep pore blockage-cake filtration phenomena and thus eliminates the need to use separate equations for different mechanisms. 展开更多
关键词 fouling MODEL Leachate WASTEWATER ULTRAFILTRATION WHEY WASTEWATER Chemical oxygen demand
下载PDF
Study on membrane fouling of submerged membrane bioreactor in treating bathing wastewater 被引量:6
15
作者 GUO Jifeng XIA Siqing +1 位作者 WANG Rongchang ZHAO Jianfu 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第10期1158-1167,共10页
A pilot-scale submerged membrane bioreactor (MBR) was used to treat the bathing wastewater for more than 90 d. Several factors a?ecting membrane fouling were studied, including the variation in transmembrane pressure ... A pilot-scale submerged membrane bioreactor (MBR) was used to treat the bathing wastewater for more than 90 d. Several factors a?ecting membrane fouling were studied, including the variation in transmembrane pressure (TMP), changes in extracellular polymeric substance (EPS), and distribution of membrane resistance (R). The relationships between R and EPS concentration were found to be R = 0.00008(EPSS)2.915 in the mixed liquor (EPSS) and R = 0.2853(EPSm) – 0.824 on the membrane surface (EPSm). The constant ... 展开更多
关键词 MBR membrane fouling extracellular polymeric substance (EPS) PCR-DGGE fluorescent in situ hybridization (FISH)
下载PDF
Fouling and cleaning of membrane——a literature review 被引量:4
16
作者 Zhao, Yan-Jun Wu, Kai-Fen +2 位作者 Wang, Zheng-Jun Zhao, Liang Li, Shu-Shen 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2000年第2期116-126,共11页
Membrane fouling curtails severely the economical and practical implementation of membrane process. The fundamental principles and mechanisms of membrane fouling as well as factors affecting fouling have been summariz... Membrane fouling curtails severely the economical and practical implementation of membrane process. The fundamental principles and mechanisms of membrane fouling as well as factors affecting fouling have been summarized in this paper. It also has covered three fouling resistance models and four kinds of approaches to improve membrane performance. Membrane cleaning methods are also discussed including physical, chemical, physico\|chemical and biological methods. In the four groups of basic cleaning methods, biological cleaning has considerable advantages and potentials. Extensive research work should be carried out further to explore and develop new ideas and techniques in the field of membrane cleaning and restoration. 展开更多
关键词 MEMBRANE fouling cleaning CLC number: X703 Document code: A
下载PDF
Study of reverse osmosis membranes fouling by inorganic salts and colloidal particles during seawater desalination 被引量:5
17
作者 Santiago Gutiérrez Ruiz Juan Antonio López-Ramírez +2 位作者 Mohammed Hassani Zerrouk Agata Egea-Corbacho Lopera JoséMaría Quiroga Alonso 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2020年第3期733-742,共10页
Fouling phenomenon is considered among the major reasons that cause significant increase of operating cost of desalination plants equipped with reverse osmosis(RO)membranes.This phenomenon is studied in the present wo... Fouling phenomenon is considered among the major reasons that cause significant increase of operating cost of desalination plants equipped with reverse osmosis(RO)membranes.This phenomenon is studied in the present work in the case of RO polyamide aromatic membranes using model seawater containing inorganic salts and colloidal compounds.Different solubility conditions of CaCO3 and CaSO4 were applied to study RO performances with and without colloid presence.During experiments,the membrane permeate fluxes were continuously monitored.Moreover,studies of chemical composition,structure,and morphology of the materials deposited on the membrane surface were conducted using energy dispersive microanalysis(EDS)X-ray diffraction and scanning electronic microscopy(SEM).Results show that in conditions of calcium carbonate oversaturation there is a reduction in the permeate flow of 11.2%due to fouling of the membrane by the precipitation of this compound.While in the same conditions of calcium sulphate oversaturation the reduction of the flow is 5%,so we can conclude that in conditions of oversaturation of both salts,calcium carbonate produces a greater fouling of the membrane that in its view causes greater decrease in the flow of permeate.All this based on the results of the test with both salts in oversaturated conditions.Resulting in the formation of calcite and gypsum crystals onto the membranes as XRD analyses stated.Additional presence of colloidal silica in those conditions intensifies strongly the fouling,leading until to 24.1%of permeate flux decrease. 展开更多
关键词 Reverse osmosis DESALINATION fouling Seawater SCALING
下载PDF
Research on Influence Factors of Membrane Fouling in A/O-MBR System 被引量:4
18
作者 WU Qing ZHANG Yue +2 位作者 ZHENG Bo ZHANG Lei ZHAO Xin-hua 《Meteorological and Environmental Research》 CAS 2011年第6期79-81,84,共4页
[Objective] The aim was to study the influence factors of membrane fouling in A/O-MBR system,so as to control membrane fouling better,prolong the service life of membrane,further reduce the cost of water treatment and... [Objective] The aim was to study the influence factors of membrane fouling in A/O-MBR system,so as to control membrane fouling better,prolong the service life of membrane,further reduce the cost of water treatment and promote the popularization of membrane bioreactor(MBR) effectively.[Method] Based on small A/O-MBR device,an orthogonal test with three factors(including aeration intensity,pump-stop ratio and mixed liquor suspended solid) and three levels was designed to optimize three parameters,and the effects of factors on membrane fouling and their mechanisms were studied through single-factor analysis.[Result] The order of operation parameters affecting membrane fouling in A/O-MBR was aeration intensity>pump-stop ratio>mixed liquor suspended solid(MLSS),and the optimum operating parameters were composed of 1.6 m3/h of aeration intensity,4 500 mg/L of MLSS and 9:2 of pump-stop ratio.With the increase of running time,soluble microbial product(SMP) and extracellular polymeric substance(EPS) accumulated gradually in the reactor,and EPS accumulated more rapidly than SMP;meanwhile,membrane fouling was accelerated.Therefore,EPS was the priority factor for membrane fouling compared with SMP.In addition,membrane fouling was accelerated gradually with the increase of protein content in EPS,while the variation of polysaccharides content in EPS had no obvious effect on membrane fouling,so protein content in EPS was the main factor for membrane fouling.[Conclusion] The study could provide theoretical references for the choice of parameters,operation and running in practical engineering. 展开更多
关键词 Membrane bioreactor Membrane fouling Characteristics of microbes Extracellular polymeric substance China
下载PDF
The Fouling Mechanism of Ceramic Membranes Used for Recovering TS-1 Catalysts 被引量:8
19
作者 仲兆祥 李冬燕 +2 位作者 刘馨 邢卫红 徐南平 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2009年第1期53-57,共5页
Ceramic ultrafiltration membranes were used to separate titanium silicalite-1 (TS-1) catalysts from the slurry of catalytic ammoximation of cyclohexanone to oxime. Silica was shown to have a great effect on membrane... Ceramic ultrafiltration membranes were used to separate titanium silicalite-1 (TS-1) catalysts from the slurry of catalytic ammoximation of cyclohexanone to oxime. Silica was shown to have a great effect on membrane fouling in the alkaline environment of this system. In the ammoximation system, there are three main silica sources, which are residual silica on the catalyst particles surface during preparation, silica dissolved from TS-1 catalyst particles by ammonia solvent, and silica sol added into the reaction slurry to inhibit the dissolution erosion of the TS-1 catalyst. The silica dissolved by ammonia has been proved to influence membrane fouling most among the three silica sources. This was because the amount of silica dissolved by ammonia was the largest, and the polymerization of silica monomers at high concentration caused colloid particles formation, which led to a dense cake layer depositing on the membrane surface. Meanwhile, the size reduction of catalyst particles caused by alkaline dissolution also increased specific resistances of cake layers. 展开更多
关键词 TS-1 catalyst ceramic membrane membrane fouling
下载PDF
Experimental Study of Fouling on Heat Transfer Surface During Forced Convective Heat Transfer 被引量:6
20
作者 全贞花 陈永昌 马重芳 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2008年第4期535-540,共6页
An experimental study was conducted to investigate the fouling process of calcium carbonate on the heat transfer surface, during forced convective heat transfer. The dynamic monitoring apparatus of fouling resistance ... An experimental study was conducted to investigate the fouling process of calcium carbonate on the heat transfer surface, during forced convective heat transfer. The dynamic monitoring apparatus of fouling resistance was set up for the present experiments. The fouling behavio(s were examined under different factors including fluid velocity, hardness,alkalinity, solution temperature, and wall temperature. Asymptotic fouling curves varying with time were obtained. The fouling rate and asymptotic fouling resistance increased and the induction periods were shortened with the fluid velocity decreasing, hardness andalkalinity increasing, and solution temperature and heat transfer surface temperature increasing. Thecomponents of fouling that formed on the heat transfer surface included crystallization fouling and particulate fouling. The thermal performance parameter of fouling,ρfhf, varied from 380 to 2600 kg·W·(m^4·K)^-1, increasing with growing velocity and decreasing solution temperature, hardness or alkalinity. Furthermore, the thermal conductivity of fouling, λf, varied from 1.7 to 2.2 W·(m·K)^-1 . 展开更多
关键词 fouling thermal resistance heat transfer calcium carbonate
下载PDF
上一页 1 2 250 下一页 到第