期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Application of Whole Membrane Water Treatment Technology in Environmental Protection
1
作者 Cuiyan Wang 《Journal of World Architecture》 2020年第5期7-9,共3页
In the current social development of our country,environmental protection has become a key content,and water treatment process is a key step to achieve environmental protection.This paper analyzes the application of w... In the current social development of our country,environmental protection has become a key content,and water treatment process is a key step to achieve environmental protection.This paper analyzes the application of whole membrane water treatment technology in environmental protection.It is hoped that this analysis can be helpful for the rational application of the whole membrane water treatment technology and the improvement of environmental protection quality. 展开更多
关键词 Environmental protection Water treatment process Whole membrane water treatment technology TECHNOLOGY
下载PDF
Membrane resealing as a promising strategy for early treatment of neurotrauma
2
作者 Xiaoming Jin 《Neural Regeneration Research》 SCIE CAS CSCD 2014年第21期1876-1877,共2页
Traumatic injuries to the central nervous system (CNS), in- cluding traumatic brain injury (TBI) and spinal cord injury (SCI), often involve an immediate mechanical damage to plas- ma membrane that surrounds neu... Traumatic injuries to the central nervous system (CNS), in- cluding traumatic brain injury (TBI) and spinal cord injury (SCI), often involve an immediate mechanical damage to plas- ma membrane that surrounds neuronal sornata and axons. This initial disruption of plasma membrane following injuries has been convincingly demonstrated by increased membrane permeability to large molecules and dyes that are normally inaccessible to cellular plasma (Farkas et al., 2006; Cho and Borgens, 2012). Further evidence comes from experiments that showed ultra-structural changes of plasma membranes, axons, and organelles, and subsequent neuronal death and axotomy (Povlishock and Pettus, 1996; Whalen et al., 2008). 展开更多
关键词 TBI membrane resealing as a promising strategy for early treatment of neurotrauma
下载PDF
Plasma Modified Polypropylene Membranes as the Lithium-Ion Battery Separators
3
作者 王正铎 朱惠钦 +3 位作者 杨丽珍 王新炜 刘忠伟 陈强 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第4期424-429,共6页
To reduce the thermal shrinkage of the polymeric separators and improve the safety of the Li-ion batteries,plasma treatment and plasma enhanced vapor chemical deposition(PECVD)of SiO_x-like are carried out on polypr... To reduce the thermal shrinkage of the polymeric separators and improve the safety of the Li-ion batteries,plasma treatment and plasma enhanced vapor chemical deposition(PECVD)of SiO_x-like are carried out on polypropylene(PP)separators,respectively.Critical parameters for separator properties,such as the thermal shrinkage rate,porosity,wettability,and mechanical strength,are evaluated on the plasma treated PP membranes.O_2 plasma treatment is found to remarkably improve the wettability,porosity and electrolyte uptake.PECVD SiO_x-like coatings are found to be able to effectively reduce the thermal shrinkage rate of the membranes and increase the ionic conductivity.The electrolyte-philicity of the Si Ox-like coating surface can be tuned by the varying O_2 content in the gas mixture during the deposition.Though still acceptable,the mechanical strength is reduced after PECVD,which is due to the plasma etching. 展开更多
关键词 microporous polypropylene membrane lithium-ion battery plasma treatment and SiO_x coating
下载PDF
20例未足月胎膜早破患者的护理 被引量:1
4
作者 李若旋 洪明萍 +1 位作者 黄丽秋 李玉珠 《内蒙古中医药》 2011年第2期168-169,共2页
回顾2007~2010年20例未足月胎膜早破病例,总结未足月胎膜早破孕妇的有效护理措施,通过心理护理、加强母儿监护、抑制宫缩、预防感染、促胎儿肺成熟等处理,可以延长孕龄,提高围产儿存活率。
关键词 胎膜早破 期待疗法 护理
下载PDF
Recent improvements in oily wastewater treatment:Progress, challenges, and future opportunities 被引量:40
5
作者 Sanaa Jamaly Adewale Giwa Shadi Wajih Hasan 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第11期15-30,共16页
Oily wastewater poses significant threats to the soil, water, air and human beings because of the hazardous nature of its oil contents. The objective of this review paper is to highlight the current and recently devel... Oily wastewater poses significant threats to the soil, water, air and human beings because of the hazardous nature of its oil contents. The objective of this review paper is to highlight the current and recently developed methods for oily wastewater treatment through which contaminants such as oil, fats, grease, and inorganics can be removed for safe applications.These include electrochemical treatment, membrane filtration, biological treatment,hybrid technologies, use of biosurfactants, treatment via vacuum ultraviolet radiation,and destabilization of emulsions through the use of zeolites and other natural minerals.This review encompasses innovative and novel approaches to oily wastewater treatment and provides scientific background for future work that will be aimed at reducing the adverse impact of the discharge of oily wastewater into the environment. The current challenges affecting the optimal performance of oily wastewater treatment methods and opportunities for future research development in this field are also discussed. 展开更多
关键词 Oily wastewater Electrochemical Biological membrane treatment
原文传递
Cyclosporin A treatment for idiopathic membranous nephropathy 被引量:2
6
作者 姚小丹 陈惠萍 +5 位作者 王庆文 唐政 胡伟新 尹广 刘志红 黎磊石 《Chinese Medical Journal》 SCIE CAS CSCD 2001年第12期73-76,108-109,共6页
Objective To evaluate the efficacy of cyclosporin A (CSA) in the treatment of idiopathic membranous nephropathy (IMN), a prospective controlled clinical study was performed. Methods This study included a group of 30 I... Objective To evaluate the efficacy of cyclosporin A (CSA) in the treatment of idiopathic membranous nephropathy (IMN), a prospective controlled clinical study was performed. Methods This study included a group of 30 IMN patients, among them 15 were treated with CSA and 15 with captopril (CAP). The diagnosis of IMN was made with exclusion of secondary forms of membranous nephropathy by extensive clinical and pathological studies. No patients received steroids or cytotoxic agents for six months prior to enrollment. In the CSA group, CSA was given at an initial dosage of 5mg*kg-1*d-1, gradually tailed off over the first three months and maintained at 2mg*kg-1*d-1 for 12 months. In the CAP group, CAP was given at a dosage of 37.5mg/day. Results In the first three months, 6 (6/15)complete remissions (CR) and 2 (2/15) partial remissions (PR) were observed in the CSA group while only 2 (2/15) PRs were observed in the CAP group. Before the end of the 15-months, 8 patients in the CSA group experienced CR and 4 patients experienced PR. One CR patient relapsed as the dosage of CSA was reduced, so 7 patients remained in CR at the end of the first 15-months. No additional CR or PR was observed in the CAP group during late follow-up. At the last visit (an average follow-up time of 44 months) in the CSA-group, another 2 CR patients had relapsed and 1 CR patient shifted to PR after stopping the CSA treatment, so 4 CR and 5 PR remained in the CSA group. In the CAP group, 3 spontaneous CRs occurred beyond 1.5 year's follow-up, with 3 CR and 2 PR at the last visit. No difference was found between the averages of the initial and the last serum creatinine levels in either group. No serious adverse effects were found during CSA treatment. Re-biopsy data of three patients responsive to CSA treatment showed that no pathological improvement of glomerular basement membrane was observed, even in cases at remission. Tubulointerstitial fibrosis was found in 1 relapsed CR patient, whoseserum creatinine increased above the normal range, but not in the other 2 patients whose serum creatinine remained in the normal range. Conclusions CSA therapy at a dosage of 5mg*kg-1*d-1 is effective in inducing remission of nephrotic syndrome in adult IMN patients within three months, with a response rate of 80%. A relatively high rate of relapse (50%) was observed within 2 years after the withdrawal of CSA treatment. 展开更多
关键词 cyclosporin A · treatment · idiopathic membranous nephropathy
原文传递
Role of membrane and compound properties in affecting the rejection of pharmaceuticals by different RO/NF membranes 被引量:6
7
作者 Yang-ying Zhao Fan-xin Kong +4 位作者 Zhi Wang Hong-wei Yang Xiao-mao Wang Yuefeng F. Xie T. David Waite 《Frontiers of Environmental Science & Engineering》 SCIE EI CAS CSCD 2017年第6期193-205,共13页
This study was conducted to assess the merits and limitations of various high-pressure membranes, tight nanofiltration (NF) membranes in particular, for the removal of trace organic compounds (TrOCs). The performa... This study was conducted to assess the merits and limitations of various high-pressure membranes, tight nanofiltration (NF) membranes in particular, for the removal of trace organic compounds (TrOCs). The performance of a low-pressure reverse osmosis (LPRO) membrane (ESPA1), a tight NF membrane (NF90) and two loose NF membranes (HL and NF270) was compared for the rejection of 23 different pharmaceuticals (PhACs). Efforts were also devoted to understand the effect of adsorption on the rejection performance of each membrane. Difference in hydrogen bond formation potential (HFP) was taken into consideration. Results showed that NF90 performed similarly to ESPA1 with mean rejection higher than 95%. NF270 outperformed HL in terms of both water permeability and PhAC rejection higher than 90%. Electrostatic effects were more significant in PhAC rejection by loose NF membranes than tight NF and LPRO membranes. The adverse effect of adsorption on rejection by HL and ESPA1 was more substantial than NF270 and NF90, which could not be simply explained by the difference in membrane surface hydrophobicity, selective layer thickness or pore size. The HL membrane had a lower rejection of PhACs of higher hydrophobicity (log D〉0) and higher HFP (〉0.02). Nevertheless, the effects of PhAC hydrophobicity and HFP on rejection by ESPA1 could not be discerned. Poor rejection of certain PhACs could generally be explained by aspects of steric hindrance, electrostatic interactions and adsorption. High-pressure membranes like NF90 and NF270 have a high promise in TrOC removal from contaminated water. 展开更多
关键词 Trace organic compounds (TrOCs) Nanofiltration (NF) Adsorption membrane properties Water treatment
原文传递
San copolymer membranes with ion exchangers for Cu(Ⅱ)removal from synthetic wastewater by electrodialysis 被引量:8
8
作者 Simona Caprarescu Mihai Cosmin Corobea +4 位作者 Violeta Purcar Catalin Ilie Spataru Raluca Ianchis Gabriel Vasilievici Zina Vuluga 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2015年第9期27-37,共11页
Heterogeneous membranes were obtained by using styrene-acrylonitrile copolymer(SAN)blends with low content of ion-exchanger particles(5 wt.%). The membranes obtained by phase inversion were used for the removal of... Heterogeneous membranes were obtained by using styrene-acrylonitrile copolymer(SAN)blends with low content of ion-exchanger particles(5 wt.%). The membranes obtained by phase inversion were used for the removal of copper ions from synthetic wastewater solutions by electrodialytic separation. The electrodialysis was conducted in a three cell unit, without electrolyte recirculation. The process, under potentiostatic or galvanostatic control, was followed by p H and conductivity measurements in the solution. The electrodialytic performance,evaluated in terms of extraction removal degree(rd) of copper ions, was better under potentiostatic control then by the galvanostatic one and the highest(over 70%) was attained at8 V. The membrane efficiency at small ion-exchanger load was explained by the migration of resin particles toward the pores surface during the phase inversion. The prepared membranes were characterized by various techniques i.e. optical microscopy, Fourier transform infrared spectroscopy, scanning electron microscopy, thermogravimetric analysis and differential thermal analysis and contact angle measurements. 展开更多
关键词 SAN copolymer membrane Ion exchange Copper ions Electrodialysis Wastewater treatment
原文传递
Positively charged microporous ceramic membrane for the removal of Titan Yellow through electrostatic adsorption 被引量:5
9
作者 Xiuting Cheng Na Li +3 位作者 Mengfu Zhu Lili Zhang Yu Deng Cheng Deng 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2016年第6期204-212,共9页
To develop a depth filter based on the electrostatic adsorption principle, positively charged microporous ceramic membrane was prepared from a diatomaceous earth ceramic membrane.The internal surface of the highly por... To develop a depth filter based on the electrostatic adsorption principle, positively charged microporous ceramic membrane was prepared from a diatomaceous earth ceramic membrane.The internal surface of the highly porous ceramic membrane was coated with uniformly distributed electropositive nano-Y2O3 coating. The dye removal performance was evaluated through pressurized filtration tests using Titan Yellow aqueous solution. It showed that positively charged microporous ceramic membrane exhibited a flow rate of 421 L/(m^2·hr) under the trans-membrane pressure of 0.03 bar. Moreover it could effectively remove Titan Yellow with feed concentration of 10 mg/L between pH 3 to 8. The removal rate increased with the enhancement of the surface charge properties with a maximum rejection of 99.6%. This study provides a new and feasible method of removing organic dyes in wastewater. It is convinced that there will be a broad market for the application of charged ceramic membrane in the field of dye removal or recovery from industry wastewater. 展开更多
关键词 Positively charged ceramic membrane Electrostatic adsorption Organic dyes Wastewater treatment
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部