期刊文献+
共找到5篇文章
< 1 >
每页显示 20 50 100
Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis
1
作者 Joaquín Fernández Manuel Rodríguez-Vallejo +2 位作者 Javier Martínez Ana Tauste David P Pi?ero 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第10期1620-1623,共4页
I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qv... I am Dr. David P Pifiero from the Department of Optics, Pharmacology and Anatomy of the University of Alicante and from the Department of Ophthalmology of Vithas Medimar (Oftalmar) and Vithas Virgen del Carmen (Qvision) hospitals in Spain. 展开更多
关键词 Figure LASIK Above-average defocus curves in photopic and mesopic vision with multifocal intraocular lenses after laser assisted in situ keratomileusis IOL
下载PDF
Impact of Lutein-Based Food Supplement on Macular Pigment, Glare and Contrast Vision
2
作者 Peter Sutter 《Open Journal of Ophthalmology》 2023年第3期316-326,共11页
Purpose: To evaluate the impact of a specially formulated food supplement containing 20 mg free lutein and 2.8 mg zeaxanthin on macular pigment volume (MPV) and visual function. Methods: In this prospective non-compar... Purpose: To evaluate the impact of a specially formulated food supplement containing 20 mg free lutein and 2.8 mg zeaxanthin on macular pigment volume (MPV) and visual function. Methods: In this prospective non-comparative study healthy subjects were instructed to take one capsule of Eagle Eye Lutein 20 Vision Caps (Innomedis AG) per day with a meal for 6 months. MPV was measured with the MP-Eye system (AzulOptics) after 3 and 6 months of treatment. Mesopic vision (MV), glare sensitivity (GS) and contrast vision threshold (CVT) were measured with the Binoptometer 4P system (OCULUS Optikgeräte). Results: Twenty-three healthy subjects between 19 and 56 years were enrolled. A significant increase was observed in MPV (p Conclusions: The specially formulated food supplement containing lutein and zeaxanthin induced a significant increase in MPV, and consequently an improvement in the visual function after 3 and 6 months in healthy subjects. 展开更多
关键词 Macular Pigment mesopic vision Glare Disability Contrast Sensitivity LUTEIN ZEAXANTHIN
下载PDF
Impact of Lutein-Based Food Supplement on Macular Pigment, Glare and Contrast Vision
3
作者 Peter Sutter 《Open Journal of Biophysics》 2023年第3期316-326,共11页
Purpose: To evaluate the impact of a specially formulated food supplement containing 20 mg free lutein and 2.8 mg zeaxanthin on macular pigment volume (MPV) and visual function. Methods: In this prospective non-compar... Purpose: To evaluate the impact of a specially formulated food supplement containing 20 mg free lutein and 2.8 mg zeaxanthin on macular pigment volume (MPV) and visual function. Methods: In this prospective non-comparative study healthy subjects were instructed to take one capsule of Eagle Eye Lutein 20 Vision Caps (Innomedis AG) per day with a meal for 6 months. MPV was measured with the MP-Eye system (AzulOptics) after 3 and 6 months of treatment. Mesopic vision (MV), glare sensitivity (GS) and contrast vision threshold (CVT) were measured with the Binoptometer 4P system (OCULUS Optikgeräte). Results: Twenty-three healthy subjects between 19 and 56 years were enrolled. A significant increase was observed in MPV (p Conclusions: The specially formulated food supplement containing lutein and zeaxanthin induced a significant increase in MPV, and consequently an improvement in the visual function after 3 and 6 months in healthy subjects. 展开更多
关键词 Macular Pigment mesopic vision Glare Disability Contrast Sensitivity LUTEIN ZEAXANTHIN
下载PDF
Ocular higher-order aberrations and mesopic pupil size in individuals screened for refractive surgery 被引量:3
4
作者 Seyed Javad Hashemian Mohammad Soleimani +4 位作者 Alireza Foroutan Mahmood Joshaghani Mohammad Jafar Ghaempanah Mohammad Ebrahim Jafari Mehdi Yaseri 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2012年第2期222-225,共4页
AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 e... AIM: To study the distribution of ocular higher-order aberrations(HOAs) and mesopic pupil size in individuals screened for refractive surgery. · METHODS: Ocular HOAs and mesopic pupil size were studied in 2 458 eyes of 1 240 patients with myopia, myopic astigmatism and compound myopic astigmatism and 215 eyes of 110 patients with hyperopia, hyperopic astigmatism and compound hyperopic astigmatism using the Zywave aberrometer (Busch& Lomb). All patients had correctable refractive errors without a history of refractive surgery or underlying diseases. Root-mean-square values of HOAs, total spherical aberration, total coma and mesopic pupil size were analyzed. Ocular HOAs were measured across a ≥ 6.0 mm pupil, and pupil size measurements were performed under the mesopic condition. · RESULTS: The mean values of HOAs, total spherical aberration and total coma in the myopic group were 0.369 μm, ±0.233, 0.133±0.112μm and 0.330±0.188μm, respectively. In the hyperopic group the mean values of HOAs, total spherical aberration and total coma were 0.418μm±0.214, 0.202±0.209μm and 0.343±0.201μm, respectively. Hyperopes showed greater total HOAs (P <0.01) and total spherical aberration (P <0.01) compared to myopes. In age-matched analysis, only the amount of total spherical aberration was higher in the hyperopic group (P =0.05). Mesopic pupil size in the myopic group was larger (P ≤0.05). · CONCLUSION: The results suggested that significant levels of HOAs were found in both groups which are important for planning refractive surgeries on Iranians. There were significantly higher levels of total spherical aberration in hyperopes compared to myopes. Mesopic pupil size was larger in myopic group. 展开更多
关键词 corneal wavefront aberration PUPIL mesopic vision RACE MYOPIA HYPEROPIA
下载PDF
Clinical study of customized aspherical intraocular lens implants 被引量:9
5
作者 Lie-Xi Jia Zhao-Hui Li 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第5期816-821,共6页
AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assign... AIM:To compare if there is an improvement in visual functions with age-related cataracts between patients receiving a aspherical intraocular lens(IOL) based on corneal wavefront aberration and patients randomly assigned lenses.METHODS:A total of 124 eyes of 124 patients with age-related cataracts were placed in experimental group and a group receiving randomly assigned(RA) lenses.The experimental group was undergone Pentacam corneal spherical aberration measurement before surgery; the targeted range for residual total spherical aberration after surgery was set to 0-0.3 μm. Patients with a corneal spherical aberration 【0.3 μm were implanted with a zero-spherical aberration advanced optics(AO) aspherical IOL and patients with an aberration ≥0.3 μm received a Tecnis Z9003 aspherical lens in experimental group. RA patients were randomly implanted with an AO lens or a Tecnis Z9003 lens. Three months after surgery total spherical aberration, photopic/mesopic contrast sensitivities, photopic/mesopic with glare contrast sensitivities, and logMAR vision were measured.RESULTS:Statistical analysis on logMAR vision showed no significant difference between two groups(P =0.413). The post-surgical total spherical aberration was 0.126 ±0.097 μm and 0.152 ±0.151 μm in the experimental and RA groups, respectively(P =0.12). The mesopic contrast sensitivities at spatial frequencies of 6,12 and 18 c/d in the experimental group were significantly higher than of the RA group(P =0.00; P =0.04;P =0.02). The mesopic with glare contrast sensitivity in the experimental group at a spatial frequency of 18 c/d was also significantly higher vs the RA group(P =0.01).CONCLUSION:Pre-surgical corneal spherical aberration measurement in cataract patients followed bycustomized selection of aspherical IOL implants improved mesopic contrast sensitivities at high spatial frequencies, and thus is a superior strategy compared to the random selection of aspherical intraocular lens implants. 展开更多
关键词 intraocular lens cataract extraction corneal wavefront aberration mesopic vision night vision
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部