BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies inve...BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies investigating its accuracy has increased.However,its accuracy has not been investigated in highland populations in China.AIM To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes(T2D)who had migrated within 3 mo from highlands to plains.METHODS Overall,68 patients with T2D,selected from those who had recently migrated from highlands to plains(within 3 mo),were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring(CGM)with the FreeStyle Libre FGM system for 14 d.Throughout the study period,fingertip capillary blood glucose was measured daily using the enzyme electrode method(Super GL,China),and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals.Moreover,the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to<5 min.The accuracy of the FGM system was evaluated according to the CGM guidelines.Subsequently,the factors influencing the mean absolute relative difference(MARD)of this system were analyzed by a multiple linear regression method.RESULTS Pearson’s correlation analysis showed that the fingertip and scanned glucose levels were positively correlated(R=0.86,P=0.00).The aggregated MARD of scanned glucose was 14.28±13.40%.Parker's error analysis showed that 99.30%of the data pairs were located in areas A and B.According to the probe wear time of the FreeStyle Libre FGM system,MARD_(1 d) and MARD_(2-14 d) were 16.55%and 14.35%,respectively(t=1.23,P=0.22).Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion(LAGE)was<5.80 mmol/L but negatively correlated with blood glucose when the LAGE was≥5.80 mmol/L.CONCLUSION The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains.This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains.MARD is mainly influenced by glucose levels and fluctuations,and the accuracy of the system is higher when the blood glucose fluctuation is small.In case of higher blood glucose level fluctuations,deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.展开更多
While hepatitis B virus(HBV)screening relies on hepatitis B surface antigen to confirm HBV infection since the early days of hepatitis B disease management,hepatitis C virus(HCV)infection screening is based on anti-HC...While hepatitis B virus(HBV)screening relies on hepatitis B surface antigen to confirm HBV infection since the early days of hepatitis B disease management,hepatitis C virus(HCV)infection screening is based on anti-HCV testing which does not discriminate active from past infection.Thus to confirm infection HCV RNA testing has been required;recently a HCV core antigen assay became widely commercially available which could serve to confirm infection.That assay is less sensitive than current HCV RNA assays,but as more than 50%of anti-HCV positive persons will be HCV core antigen positive,HCV core antigen testing can be a cost effective and reflex test to confirm HCV infection in anti-HCV positive individuals and will be easier as it can be applied on the same platform.For treatment monitoring,more data need to be generated,but the early data available at present suggest that HCV core antigen may be an alternative to HCV RNA monitoring.With direct antivirals,HCV core antigen could even be superior to HCV RNA testing,as direct antivirals might already prevent virus formation when HCV core antigen is still produced and thereby correlates better with eventual viral clearance.展开更多
Based on the low-carbon and high-value methodology of chemical ecology and chemical informatics,combining theory and methods,taking saving,environmental protection,low carbon,high production,high value and circulation...Based on the low-carbon and high-value methodology of chemical ecology and chemical informatics,combining theory and methods,taking saving,environmental protection,low carbon,high production,high value and circulation as values and aims,the relationship between human and land as a basis,ecosystem as a center,overall control as a goal and agricultural ecological engineering as a mean,environmental pollution detection,as one of bottlenecks for agricultural products and food security,should be solved firstly;through the field survey in dry years from 2009 to 2010 when drought and flood were frequent and the frequency of drought was higher than that of flood,plus the determination of surface water flow and water quantity in a small typical river basin,the correlation of local water,soil and gas in the county could be found,and the transfer of monitoring focus from water environment to atmospheric environment was possible and necessary.The study would promote the quantitative research on the correlation among water,soil and gas,and the results were in accordance with the conclusions of related studies.展开更多
In this paper we will investigate some non-asymptotic properties of the modified least squares estimates for the non-linear function f(λ*) by observations that nonlinearly depend on the parameter λ*. Non-asymptotic ...In this paper we will investigate some non-asymptotic properties of the modified least squares estimates for the non-linear function f(λ*) by observations that nonlinearly depend on the parameter λ*. Non-asymptotic confidence regions with fixed sizes for the modified least squares estimate are used. The obtained confidence region is valid for a finite number of data points when the distributions of the observations are unknown. Asymptotically the suggested estimates represent usual estimates of the least squares. The paper presents the results of practical applications of the proposed method in C-OTDR monitoring systems.展开更多
Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuri...Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.展开更多
Objective:This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems(BGMSs)and explore the differences in the system accuracy acceptability of each BGMS against five different s...Objective:This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems(BGMSs)and explore the differences in the system accuracy acceptability of each BGMS against five different standards.Methods:The glucose measurement values obtained from four types of BGMSs(Roche Accu-Chek® Performa,Bayer Contour™ TS,Sinomedisite Glupad® H1 Plus,and Sinocare® Gold-Accu)were evaluated against the reference values obtained from the biochemical analyzer of the central laboratory.The system accuracy acceptability of each BGMS was determined using the criteria specified in five standards,namely the International Organization for Standardization(ISO)15197:2003,Clinical Laboratory Standards Institute(CLSI)POCT12-A3,ISO 15197:2013,Chinese Society of Laboratory Medicine(CSLM)consensus,and US Food and Drug Administration(FDA)guidelines.Results:From 2018 to 2022,10,980 pairs of measurement values were obtained from 366 glucose meters of four types of BGMSs.Significant correlations were observed between the glucose measurement values from the BGMSs and the reference values from the biochemical analyzer of the central laboratory.The correlation coefficient r was 0.995 for Roche Accu-Chek® Performa,0.994 for Bayer Contour™ TS,0.983 for Sinomedisite Glupad® H1 Plus,and 0.997 for SinocareR Gold-Accu.The acceptability criteria specified in ISO 15197:2003 were met by 100.00%(135/135)of the glucose meters of Roche Accu-Chek® Performa,100.00%(109/109)of Bayer Contour™ TS,81.61%(71/87)of Sinomedisite Glupad® H1 Plus,and 100.00%(35/35)of SinocareR Gold-Accu.Whereas,the acceptability criteria specified in ISO 15197:2013 were met by 99.26%(134/135)of the glucose meters of Roche Accu-Chek® Performa,88.07%(96/109)of Bayer Contour™ TS,58.62%(51/87)of Sinomedisite Glupad R H1 Plus,and 91.43%(32/35)of SinocareR Gold-Accu.Conclusions:Among the four types of BGMSs evaluated,the glucose meters of Roche Accu-Chek® Performa exhibited superior system accuracy.The system accuracy acceptability of each BGMS varied significantly against the acceptability criteria specified in the five different standards.展开更多
Considering the quality of life, manpower, and expenditure, an IoT-based health monitoring system has been proposed and implemented. Devices are placed on the human body to collect data, which is then uploaded to an o...Considering the quality of life, manpower, and expenditure, an IoT-based health monitoring system has been proposed and implemented. Devices are placed on the human body to collect data, which is then uploaded to an online data server. Specialist doctors can access this data as needed, allowing them to assess the patient’s initial condition and provide advice at any time. This approach enhances the quality and reach of health services. The module, designed and installed using modern technology, minimizes latency and maximizes data accuracy while reducing delay and battery drain. An accompanying app motivates public acceptance and ease of use. Various sensors, including ECG, SpO2, gyroscope, PIR, temperature-humidity, and BP, collect data processed by an Arduino microcontroller. Data transmission is handled by a WiFi module, with ThingSpeak and Google Sheets used for data processing and storage. The system has been fully tested, and patient data from two hospitals compared with the proposed model shows 97% accuracy.展开更多
基金Supported by Health and Family Planning Project of Sichuan Province,No.17PJ069Tibet Autonomous Region Science and Technology Program,No.XZ202303ZY0011G.
文摘BACKGROUND The FreeStyle Libre flash glucose monitoring(FGM)system entered the Chinese market in 2017 to complement the self-monitoring of blood glucose.Due to its increased usage in clinics,the number of studies investigating its accuracy has increased.However,its accuracy has not been investigated in highland populations in China.AIM To evaluate measurements recorded using the FreeStyle Libre FGM system compared with capillary blood glucose measured using the enzyme electrode method in patients with type 2 diabetes(T2D)who had migrated within 3 mo from highlands to plains.METHODS Overall,68 patients with T2D,selected from those who had recently migrated from highlands to plains(within 3 mo),were hospitalized at the Department of Endocrinology from August to October 2017 and underwent continuous glucose monitoring(CGM)with the FreeStyle Libre FGM system for 14 d.Throughout the study period,fingertip capillary blood glucose was measured daily using the enzyme electrode method(Super GL,China),and blood glucose levels were read from the scanning probe during fasting and 2 h after all three meals.Moreover,the time interval between reading the data from the scanning probe and collecting fingertip capillary blood was controlled to<5 min.The accuracy of the FGM system was evaluated according to the CGM guidelines.Subsequently,the factors influencing the mean absolute relative difference(MARD)of this system were analyzed by a multiple linear regression method.RESULTS Pearson’s correlation analysis showed that the fingertip and scanned glucose levels were positively correlated(R=0.86,P=0.00).The aggregated MARD of scanned glucose was 14.28±13.40%.Parker's error analysis showed that 99.30%of the data pairs were located in areas A and B.According to the probe wear time of the FreeStyle Libre FGM system,MARD_(1 d) and MARD_(2-14 d) were 16.55%and 14.35%,respectively(t=1.23,P=0.22).Multiple stepwise regression analysis showed that MARD did not correlate with blood glucose when the largest amplitude of glycemic excursion(LAGE)was<5.80 mmol/L but negatively correlated with blood glucose when the LAGE was≥5.80 mmol/L.CONCLUSION The FreeStyle Libre FGM system has good accuracy in patients with T2D who had recently migrated from highlands to plains.This system might be ideal for avoiding the effects of high hematocrit on blood glucose monitoring in populations that recently migrated to plains.MARD is mainly influenced by glucose levels and fluctuations,and the accuracy of the system is higher when the blood glucose fluctuation is small.In case of higher blood glucose level fluctuations,deviation in the scanned glucose levels is the highest at extremely low blood glucose levels.
文摘While hepatitis B virus(HBV)screening relies on hepatitis B surface antigen to confirm HBV infection since the early days of hepatitis B disease management,hepatitis C virus(HCV)infection screening is based on anti-HCV testing which does not discriminate active from past infection.Thus to confirm infection HCV RNA testing has been required;recently a HCV core antigen assay became widely commercially available which could serve to confirm infection.That assay is less sensitive than current HCV RNA assays,but as more than 50%of anti-HCV positive persons will be HCV core antigen positive,HCV core antigen testing can be a cost effective and reflex test to confirm HCV infection in anti-HCV positive individuals and will be easier as it can be applied on the same platform.For treatment monitoring,more data need to be generated,but the early data available at present suggest that HCV core antigen may be an alternative to HCV RNA monitoring.With direct antivirals,HCV core antigen could even be superior to HCV RNA testing,as direct antivirals might already prevent virus formation when HCV core antigen is still produced and thereby correlates better with eventual viral clearance.
基金Supported by Specific Research Project for National Environmental Public Welfare Industry " Study on the Control Technology of Agricultural Pollution System in the Subtropical Zone"Postdoctoral Science Foundation of Central South University
文摘Based on the low-carbon and high-value methodology of chemical ecology and chemical informatics,combining theory and methods,taking saving,environmental protection,low carbon,high production,high value and circulation as values and aims,the relationship between human and land as a basis,ecosystem as a center,overall control as a goal and agricultural ecological engineering as a mean,environmental pollution detection,as one of bottlenecks for agricultural products and food security,should be solved firstly;through the field survey in dry years from 2009 to 2010 when drought and flood were frequent and the frequency of drought was higher than that of flood,plus the determination of surface water flow and water quantity in a small typical river basin,the correlation of local water,soil and gas in the county could be found,and the transfer of monitoring focus from water environment to atmospheric environment was possible and necessary.The study would promote the quantitative research on the correlation among water,soil and gas,and the results were in accordance with the conclusions of related studies.
文摘In this paper we will investigate some non-asymptotic properties of the modified least squares estimates for the non-linear function f(λ*) by observations that nonlinearly depend on the parameter λ*. Non-asymptotic confidence regions with fixed sizes for the modified least squares estimate are used. The obtained confidence region is valid for a finite number of data points when the distributions of the observations are unknown. Asymptotically the suggested estimates represent usual estimates of the least squares. The paper presents the results of practical applications of the proposed method in C-OTDR monitoring systems.
文摘Global efforts for environmental cleanliness through the control of gaseous emissions from vehicles are gaining momentum and attracting increasing attention. Calibration plays a crucial role in these efforts by ensuring the quantitative assessment of emissions for informed decisions on environmental treatments. This paper describes a method for the calibration of CO/CO<sub>2</sub> monitors used for periodic inspections of vehicles in cites. The calibration was performed in the selected ranges: 900 - 12,000 µmol/mol for CO and 2000 - 20,000 µmol/mol for CO<sub>2</sub>. The traceability of the measurement results to the SI units was ensured by using certified reference materials from CO/N<sub>2</sub> and CO<sub>2</sub>/N<sub>2</sub> primary gas mixtures. The method performance was evaluated by assessing its linearity, accuracy, precision, bias, and uncertainty of the calibration results. The calibration data exhibited a strong linear trend with R² values close to 1, indicating an excellent fit between the measured values and the calibration lines. Precision, expressed as relative standard deviation (%RSD), ranged from 0.48 to 4.56% for CO and from 0.97 to 3.53% for CO<sub>2</sub>, staying well below the 5% threshold for reporting results at a 95% confidence level. Accuracy measured as percent recovery, was consistently high (≥ 99.1%) for CO and ranged from 84.90% to 101.54% across the calibration range for CO<sub>2</sub>. In addition, the method exhibited minimal bias for both CO and CO<sub>2</sub> calibrations and thus provided a reliable and accurate approach for calibrating CO/CO<sub>2</sub> monitors used in vehicle inspections. Thus, it ensures the effectiveness of exhaust emission control for better environment.
文摘Objective:This study aimed to evaluate the system accuracy of four types of blood glucose monitoring systems(BGMSs)and explore the differences in the system accuracy acceptability of each BGMS against five different standards.Methods:The glucose measurement values obtained from four types of BGMSs(Roche Accu-Chek® Performa,Bayer Contour™ TS,Sinomedisite Glupad® H1 Plus,and Sinocare® Gold-Accu)were evaluated against the reference values obtained from the biochemical analyzer of the central laboratory.The system accuracy acceptability of each BGMS was determined using the criteria specified in five standards,namely the International Organization for Standardization(ISO)15197:2003,Clinical Laboratory Standards Institute(CLSI)POCT12-A3,ISO 15197:2013,Chinese Society of Laboratory Medicine(CSLM)consensus,and US Food and Drug Administration(FDA)guidelines.Results:From 2018 to 2022,10,980 pairs of measurement values were obtained from 366 glucose meters of four types of BGMSs.Significant correlations were observed between the glucose measurement values from the BGMSs and the reference values from the biochemical analyzer of the central laboratory.The correlation coefficient r was 0.995 for Roche Accu-Chek® Performa,0.994 for Bayer Contour™ TS,0.983 for Sinomedisite Glupad® H1 Plus,and 0.997 for SinocareR Gold-Accu.The acceptability criteria specified in ISO 15197:2003 were met by 100.00%(135/135)of the glucose meters of Roche Accu-Chek® Performa,100.00%(109/109)of Bayer Contour™ TS,81.61%(71/87)of Sinomedisite Glupad® H1 Plus,and 100.00%(35/35)of SinocareR Gold-Accu.Whereas,the acceptability criteria specified in ISO 15197:2013 were met by 99.26%(134/135)of the glucose meters of Roche Accu-Chek® Performa,88.07%(96/109)of Bayer Contour™ TS,58.62%(51/87)of Sinomedisite Glupad R H1 Plus,and 91.43%(32/35)of SinocareR Gold-Accu.Conclusions:Among the four types of BGMSs evaluated,the glucose meters of Roche Accu-Chek® Performa exhibited superior system accuracy.The system accuracy acceptability of each BGMS varied significantly against the acceptability criteria specified in the five different standards.
文摘Considering the quality of life, manpower, and expenditure, an IoT-based health monitoring system has been proposed and implemented. Devices are placed on the human body to collect data, which is then uploaded to an online data server. Specialist doctors can access this data as needed, allowing them to assess the patient’s initial condition and provide advice at any time. This approach enhances the quality and reach of health services. The module, designed and installed using modern technology, minimizes latency and maximizes data accuracy while reducing delay and battery drain. An accompanying app motivates public acceptance and ease of use. Various sensors, including ECG, SpO2, gyroscope, PIR, temperature-humidity, and BP, collect data processed by an Arduino microcontroller. Data transmission is handled by a WiFi module, with ThingSpeak and Google Sheets used for data processing and storage. The system has been fully tested, and patient data from two hospitals compared with the proposed model shows 97% accuracy.