期刊文献+
共找到2,054篇文章
< 1 2 103 >
每页显示 20 50 100
Carrier fringe method of moire interferometry for tiny strain measurements in micro-field 被引量:2
1
作者 Yudong Cao Shibin Wang +1 位作者 Shuangxi Qi Jingwei Tong 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2009年第1期101-106,共6页
In this paper, we demonstrate a new optical method for tiny strain measurements based on the principle of carrier fringes of moire interferometry. A cross-line grating with frequency of 1200 lp/mm is replicated on the... In this paper, we demonstrate a new optical method for tiny strain measurements based on the principle of carrier fringes of moire interferometry. A cross-line grating with frequency of 1200 lp/mm is replicated on the specimen surface, and the strain can be deduced from the changes in carrier fringes before and after the deformation of an object. Four coherent laser beams are used to obtain the carrier fringe patterns of field U and V. Both theoretical analysis and numerical simulation indicate that the ideal accuracy of strain can be controlled within a range of ±1με. Case study of a plane extension experiment shows that the measurement accuracy of strain can be controlled within the range of ±10με. The average strain values of every row of field U and every column of field V can be obtained by using this method, and approximated strain of every pixel in the whole-field can be further acquired, and thus it is possible to measure tiny strains occurred in a micro-field. The technology in this paper can provide comprehensive information for analyzing related mechanical content in the field of MEMS. 展开更多
关键词 Moire interferometry - Carrier fringe micro-field Tiny strain. measured accuracy
下载PDF
Multi-Schlieren CT Measurements of Supersonic Microjets from Circular and Square Micro Nozzles 被引量:1
2
作者 Ahmad Zaid Nazari Yojiro Ishino +6 位作者 Yuta Ishiko Fumiya Ito Harumi Kondo Ryoya Yamada Takanori Motohiro Yoshiaki Miyazato Shinichiro Nakao 《Journal of Flow Control, Measurement & Visualization》 2020年第3期77-101,共25页
Instantaneous three-dimensional (3D) density distributions of a shock-cell structure of perfectly and imperfectly expanded supersonic microjets escaping into an ambient space are measured. For the 3D observation of su... Instantaneous three-dimensional (3D) density distributions of a shock-cell structure of perfectly and imperfectly expanded supersonic microjets escaping into an ambient space are measured. For the 3D observation of supersonic microjets, non-scanning 3D computerized tomography (CT) technique using a 20-directional quantitative schlieren optical system with flashlight source is employed for simultaneous schlieren photography. The 3D density distributions data of the microjets are obtained by 3D-CT reconstruction of the projection’s images using maximum likelihood-expectation maximization. Axisymmetric convergent-divergent (Laval) circular and square micro nozzles with operating nozzle pressure ratio 5.0, 4.5, 4.0, 3.67, and 3.5 have been studied. This study examines perfectly expanded, overexpanded, and underexpanded supersonic microjets issued from micro nozzles with fully expanded jet Mach numbers <em>M</em><em><sub>j</sub></em> ranging from 1.47 - 1.71, where the design Mach number is <em>M<sub>d</sub></em> = 1.5. A complex phenomenon for free square microjets called axis switching is clearly observed with two types “upright” and “diagonal” of “cross-shaped”. The initial axis-switching is 45<span style="white-space:nowrap;">°</span> within the first shock-cell range. In addition, from the symmetry and diagonal views of square microjets for the first shock-cells, two different patterns of shock waves are viewed. The shock-cell spacing and supersonic core length for all nozzle pressure ratios are investigated and reported. 展开更多
关键词 Supersonic microjet Multi-Directional Quantitative Schlieren Optical System Three-Dimensional (3D) measurement Computerized Tomography (CT) Circular and Square micro Laval Nozzles
下载PDF
Comparison between Double Crystals X-ray Diffraction and Micro-Raman Measurement on Composition Determination of High Ge Content Si_(1-x)Ge_(x) Layer Epitaxied on Si Substrate 被引量:1
3
作者 Lei ZHAO Yuhua ZUO Buwen CHENG Jinzhong YU Qiming WANG 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2006年第5期651-654,共4页
It is important to acquire the composition of Si1-xGex layer, especially that with high Ge content, epitaxied on Si substrate. Two nondestructive examination methods, double crystals X-ray diffraction (DCXRD) and mi... It is important to acquire the composition of Si1-xGex layer, especially that with high Ge content, epitaxied on Si substrate. Two nondestructive examination methods, double crystals X-ray diffraction (DCXRD) and micro-Raman measurement, were introduced comparatively to determine x value in Si1-xGex layer, which show that while the two methods are consistent with each other when x is low, the results obtained from double crystals X-ray diffraction are not credible due to the large strain relaxation occurring in Si1-xGex layers when Ge content is higher than about 20%. Micro-Raman measurement is more appropriate for determining high Ge content than DCXRD. 展开更多
关键词 Si1-xGex Ge content Composition determination Double crystals X-ray diffraction (DCXRD) micro-Raman measurement
下载PDF
High-Precision Wideband Phase-Derived Velocity Measurement for Micro-Motion Extraction
4
作者 Yuan Jiang Huayu Fan +1 位作者 Quanhua Liu Xinliang Chen 《Journal of Beijing Institute of Technology》 EI CAS 2017年第1期106-114,共9页
A phase-derived velocity measurement method is proposed in a wideband coherent system,based on a precise echo model considering the inner pulse Doppler effect caused by fast moving targets.The Cramer-Rao low band of v... A phase-derived velocity measurement method is proposed in a wideband coherent system,based on a precise echo model considering the inner pulse Doppler effect caused by fast moving targets.The Cramer-Rao low band of velocity measurement precision is deduced,demonstrating the high precision of the proposed method.Simulations and out-field experiments further validate the effectiveness of the proposed method in high-precision measurement and micro-motion extraction for targets with weak reflection intensity.Compared with the long-time integration approaches for velocity measurement,the phase-derived method is easy to implement and meets the requirement for high data rate,which makes it suitable for micro-motion feature extraction in wideband systems. 展开更多
关键词 phase-derived velocity measurement micro-motion extraction wideband coherent sys-tem high-precision measurement
下载PDF
基于IQPSO-EKF的多传感器融合姿态测量方法研究
5
作者 胡启国 王磊 +1 位作者 马鉴望 任渝荣 《机电工程》 CAS 北大核心 2024年第2期353-363,共11页
为解决自动化竖井掘进设备的定位调姿精度对竖井、孔桩挖掘效率与质量的影响,提出了一种基于改进量子粒子群(IQPSO)-扩展卡尔曼滤波(EKF)的姿态测量算法,以提高微机电系统(MEMS)传感器测量精度。首先,对MEMS传感器数据进行了预处理(除... 为解决自动化竖井掘进设备的定位调姿精度对竖井、孔桩挖掘效率与质量的影响,提出了一种基于改进量子粒子群(IQPSO)-扩展卡尔曼滤波(EKF)的姿态测量算法,以提高微机电系统(MEMS)传感器测量精度。首先,对MEMS传感器数据进行了预处理(除噪、滤波、校准等);然后,参考现有飞行器的坐标系,建立了姿态解算模型,通过姿态角数学模型及运动学分析,构建了EFK状态方程,针对EKF方法参数估计不准确的问题,以分段混沌映射优化初始种群,引入平均位置最优值来避免陷入局部最优的IQPSO-EFK算法,优化EKF的系统、测量噪声的协方差参数;最后,对改进算法和三组姿态误差估计进行了对比实验。研究结果表明:对比三种典型目标函数,IQPSO-EFK相较于普通粒子群算法(QPSO-EFK)具有更强的寻优能力与收敛精度;对比三组旋转速度姿态测量误差,基于IQPSO-EKF算法的姿态测量方法在测量误差时比真实测量误差减少了约86.3%,比扩展卡尔曼滤波减少了约68.7%,比普通粒子群算法减少了约28.2%,证明该算法有效地提高了MEMS传感器测量精度。 展开更多
关键词 竖井掘进 角度测量仪器 姿态测量 微机电系统传感器 多传感器融合 改进量子粒子群-扩展卡尔曼滤波
下载PDF
基于改进LSTM网络的无人机MEMS-IMU零偏在线标定方法
6
作者 程向红 吴昕怡 +1 位作者 刘丰宇 钟志伟 《中国惯性技术学报》 EI CSCD 北大核心 2024年第3期213-218,共6页
针对在卫星信号拒止、视觉系统退化场景中无人机MEMS-IMU零偏无法准确估计并补偿导致导航误差迅速发散的问题,提出一种基于改进长短时记忆(LSTM)网络的零偏在线标定方法。首先,为解决MEMS-IMU零偏数据非线性强、传统循环时间网络训练效... 针对在卫星信号拒止、视觉系统退化场景中无人机MEMS-IMU零偏无法准确估计并补偿导致导航误差迅速发散的问题,提出一种基于改进长短时记忆(LSTM)网络的零偏在线标定方法。首先,为解决MEMS-IMU零偏数据非线性强、传统循环时间网络训练效果差的问题,设计序列到序列的LSTM神经网络结构,引入教师强迫机制,提高了网络特征学习能力。然后,在导航过程中使用训练后的网络对MEMS-IMU零偏在线标定,补偿后的IMU量测与视觉信息联合优化,保证了导航定位精度。实验结果表明,在纯惯性导航实验中,所提方法的绝对位置误差比传统LSTM方法减小了6.5%;在EUROC数据集下进行的视觉惯性组合导航实验中,所提方法的平均绝对位置误差比传统LSTM方法减小了15%。 展开更多
关键词 无人机导航定位 微惯性测量单元 在线标定 长短时记忆神经网络
下载PDF
Measurements of non-equilibrium and equilibrium temperature behind a strong shock wave in simulated martian atmosphere 被引量:4
7
作者 Xin Lin Xi-Long Yu +3 位作者 Fei Li Shao-Hua Zhang Jian-Guo Xin Xin-Yu Zhang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2012年第5期1296-1302,共7页
Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso... Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry. 展开更多
关键词 Radiation measurements - Shock wave Marsre-entry Rotational temperature Vibrational temperature
下载PDF
MIMO Channel Measurement and Characterization at 6.0-6.4 GHz Under Typical Classroom Environment 被引量:3
8
作者 Ji-Liang Zhang Yang Wang +2 位作者 Li-Qin Ding Xiao-Min Huang Nai-Tong Zhang 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第1期69-76,共8页
An extensive 4 x 4 MIMO channel measurement is carried out at 6. 0-6. 4 GHz under a typical classroom environment with channel sounder based on vector network analyzer. Both LOS and NLOS scenarios are considered. The ... An extensive 4 x 4 MIMO channel measurement is carried out at 6. 0-6. 4 GHz under a typical classroom environment with channel sounder based on vector network analyzer. Both LOS and NLOS scenarios are considered. The results on path loss, delay spread and spatial correlation are presented. The measurement shows that, for corridor coverage, 2x2 MIMO is more economical than 4x4 MIMO due to high correlation. In order to identify the unique characteristics at the high frequency band, the measured channel parameters at 6. 0-6.4 GHz are compared with those at 2. 45 GHz. The comparison shows that the shortened wavelength of this higher frequency band results in a great difference of channel characteristics. Therefore, our measurement results provide new gnidance for the design and development of the system working on 6. 0-6.4 GHz band. 展开更多
关键词 6. 0-6.4 GHz muhi-input multi-output (MIMO) channel measurement channel characteristics
下载PDF
Measurement and simulation of the two-phase velocity correlation in sudden-expansion gas-particle flows 被引量:3
9
作者 Li-Xing Zhou.Yang Liu.Yi Xu Department of Engineering Mechanics,Tsinghua University,100084 Beijing,China Marine Engineering College,Dalian Maritime University,116026 Dalian,China 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2011年第4期494-501,共8页
In this paper the present authors measured the gas-particle two-phase velocity correlation in sudden expansion gas-particle flows with a phase Doppler particle anemometer (PDPA) and simulated the system behavior by ... In this paper the present authors measured the gas-particle two-phase velocity correlation in sudden expansion gas-particle flows with a phase Doppler particle anemometer (PDPA) and simulated the system behavior by using both a Reynolds-averaged Navier-Stokes (RANS) model and a large-eddy simulation (LES). The results of the measurements yield the axial and radial time-averaged velocities as well as the fluctuation velocities of gas and three particle-size groups (30μm, 50μm, and 95μm) and the gasparticle velocity correlation for 30μm and 50μm particles. From the measurements, theoretical analysis, and simulation, it is found that the two-phase velocity correlation of sudden-expansion flows, like that of jet flows, is less than the gas and particle Reynolds stresses. What distinguishes the two-phase velocity correlations of sudden-expansion flow from those of jet and channel flows is the absence of a clear relationship between the two-phase velocity correlation and particle size in sudden-expansion flows. The measurements, theoretical analysis, and numerical simulation all lead to the above-stated conclusions. Quantitatively, the results of the LES are better than those of the RANS model. 展开更多
关键词 PDPA measurement - Simulation Two-phasevelocity correlation Sudden expansion gas-particle flows
下载PDF
基于MIMU与Wi-Fi的普适室内定位方法综述
10
作者 张帅 陈建广 +3 位作者 陈锐志 汪云甲 黄风华 李召洋 《导航定位与授时》 CSCD 2024年第5期1-16,F0002,共17页
室内导航定位作为城市数字化转型的重要基石和关键技术之一,在智慧城市发展建设的过程中起到至关重要的作用。然而,受复杂多变的室内环境、空间结构布局及室内行人活动等影响,实现准确可靠、普适泛在的室内定位,满足大众化的定位需求,... 室内导航定位作为城市数字化转型的重要基石和关键技术之一,在智慧城市发展建设的过程中起到至关重要的作用。然而,受复杂多变的室内环境、空间结构布局及室内行人活动等影响,实现准确可靠、普适泛在的室内定位,满足大众化的定位需求,有效助力智慧城市发展仍面临很大的挑战。其中,基于微惯性测量单元(MIMU)的航位推算定位方法具有体积小、成本低、自主性强及实时性高等特点,且现有无线保真(Wi-Fi)信号覆盖广泛,无需额外布设设备,使得基于MIMU与Wi-Fi的室内定位技术因具有广泛的研究价值和意义而受到广泛关注。主要围绕基于MIMU与Wi-Fi的室内定位方法进行综述。首先,分类阐述了基于MIMU的室内定位方法原理,并概括了其存在的问题及研究现状;其次,分析了基于Wi-Fi的室内定位方法研究的局限性与面临的挑战,重点总结了基于机器学习的Wi-Fi指纹室内定位方法研究现状;再次,系统对比分析了现有的基于MIMU与Wi-Fi的融合定位方法,考虑了其优缺点及各自的适用性;最后,对基于MIMU与Wi-Fi的定位方法未来的发展趋势进行了展望。 展开更多
关键词 室内定位 微惯性测量单元 WI-FI 融合定位
下载PDF
Development of laser and microwave scanning technologies in the blast furnace burden profile and lining condition measurement at CSC
11
作者 KUO Shihkang 《Baosteel Technical Research》 CAS 2010年第S1期13-,共1页
In order to stabilise the operation of the blast furnace and to raise its operation efficiency,research works for the application of microwave and laser scanning technologies to the measurement have been intensively c... In order to stabilise the operation of the blast furnace and to raise its operation efficiency,research works for the application of microwave and laser scanning technologies to the measurement have been intensively carried out at China Steel Corporation(CSC).To monitor the burden profile during the operation,a microwave burden profile measuring system was developed.The system consists of a radar unit,a signal processing system, and a driving device which is capable of rotating the radar to scan the burden surface in a specified direction.A nitrogen cooling system was designed to protect the measurement system.A prototype burden profile meter was successfully tested in No.1 blast furnace in 2008,and a permanent one was installed at No.3 blast furnace.The system has provided useful information for adjusting the charging sequence in No.3 blast furnace.For another application,3 - D laser scanning technology is employed to monitor the blast furnace lining condition.To this end,a data registration method has been developed,through which two measured range images sensed at different period and locations can be fitted into the same coordinate system.In practice,the erosion of the blast furnace lining can be estimated when the current inner profile is compared with that taken before the blow-in operation. This technology is also adopted to evaluate the performance of gunning operation in the blast furnaces at CSC. 展开更多
关键词 blast furnace measurement laser scanning micro wave burden profile meter
下载PDF
3-Dimensional Body Measurement Technology
12
作者 周旭东 李艳梅 《Journal of Donghua University(English Edition)》 EI CAS 2002年第4期138-140,共3页
3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body... 3 - dimensional body measurement technology, the basis of developing high technology in industry, accelerates digital development of aplparel industry. This paper briefly introduces the history of 3 - dimensional body measurement technology, and recounts the principle and primary structure of some types of 3 - dimensional automatic body measurement system. With this understanding, it discusses prospect of 3- dimensional CAD and virtual technology used in apparel industry. 展开更多
关键词 3 - DIMENSIONAL BODY measurement technology digital apparel industry quick response virtual fitting apparel NAD
下载PDF
Test of Normality of Waist Measurement Data of Young Male and Female Adults based on the Quantile - Quantile Plot
13
作者 F. Z. Okwonu J. N. Igabari 《Journal of Statistical Science and Application》 2017年第3期118-126,共9页
This paper investigates the normality of some real data set obtained from waist measurements of a group of 49 young adults. The quantile - quantile (Q-Q) plot and the analysis of correlation coefficients for the Q-Q... This paper investigates the normality of some real data set obtained from waist measurements of a group of 49 young adults. The quantile - quantile (Q-Q) plot and the analysis of correlation coefficients for the Q-Q plot is used to determine the normality or otherwise of the data set. In this regards, the probabilities of the quantiles were computed, modified and plotted. Thereafter the correlation coefficients for the quantile - quantile plots were obtained. Results indicate that at 0.1 level of significance, the data for young adult males of the sample were not normally distributed, and had a mean value that is within the range of low risk, healthwise, whereas the distribution of the data for young female adults showed reasonable normality, but also with a mean value that is within the range of low risk in terms of health condition. 展开更多
关键词 Correlation coefficient probability plot quantile - quantile plot test of normality waist measurement young adults.
下载PDF
A Steady-State Errors Correction Method for Eliminating Measurement Errors
14
作者 田新良 杨苹 《Journal of Donghua University(English Edition)》 EI CAS 2013年第4期298-304,共7页
This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In c... This paper proposes a steady-state errors correction(SSEC)method for eliminating measurement errors.This method is based on the detections of error signal E(s)and output C(s)which generate an expected output R(s).In comparison with the conventional solutions which are based on detecting the expected output R(s)and output C(s)to obtain error signal E(s),the measurement errors are eliminated even the error might be at a significant level.Moreover,it is possible that the individual debugging by regulating the coefficient K for every member of the multiple objectives achieves the optimization of the open loop gain.Therefore,this simple method can be applied to the weak coupling and multiple objectives system,which is usually controlled by complex controller.The principle of eliminating measurement errors is derived analytically,and the advantages comparing with the conventional solutions are depicted.Based on the SSEC method analysis,an application of this method for an active power filter(APF)is investigated and the effectiveness and viability of the scheme are demonstrated through the simulation and experimental verifications. 展开更多
关键词 measurement errors steady-state errors correction (SSEC) active power filters (APF)CLC number:TM77Document code:AArticle ID:1672-5220(2013)04-0298-07
下载PDF
不同长度micro-lysimeters对测定土壤蒸发的影响 被引量:31
15
作者 孙宏勇 刘昌明 +2 位作者 张喜英 张永强 沈彦俊 《西北农林科技大学学报(自然科学版)》 CSCD 北大核心 2003年第4期167-170,共4页
研究了 5 ,10 ,15 ,2 0 ,2 5 cm共 5种不同长度处理和内壁有孔、内外壁均有孔 2种处理由 PVC管制成的 micro- lysimeters对土壤蒸发的影响。结果表明 :降雨后 5 ,10 cm处理的土壤水分蒸发较快 ,15 ,2 0 ,2 5 cm处理的变化不明显 ,可以利... 研究了 5 ,10 ,15 ,2 0 ,2 5 cm共 5种不同长度处理和内壁有孔、内外壁均有孔 2种处理由 PVC管制成的 micro- lysimeters对土壤蒸发的影响。结果表明 :降雨后 5 ,10 cm处理的土壤水分蒸发较快 ,15 ,2 0 ,2 5 cm处理的变化不明显 ,可以利用 15 cm长的 m icro- lysimeters测定土壤蒸发 ;壁上有孔处理的蒸发要高于同样长度的无孔处理。 展开更多
关键词 长度 micro-lysimeters 测定技术 土壤蒸发 影响因素
下载PDF
DISTRIBUTED MICROBEND FIBER-OPTIC STRAIN SENSOR
16
作者 孟爱东 骆飞 袁慎芳 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2000年第2期224-227,共4页
The distributed strain sensor has significant application in real time measurement of strain status for large and important engineering structures such as aircraft, bridge and dam. In this paper, a quasi distributed... The distributed strain sensor has significant application in real time measurement of strain status for large and important engineering structures such as aircraft, bridge and dam. In this paper, a quasi distributed optical fiber strain sensor system is set up using optical time domain reflect technique. The local strain sensors based on a novel microbend configuration are designed and applied to measure local strains along the optical fiber. As the result of the experimental research, the microbend sensors show high sensitivity, good linearity and repeatability in certain operation range. 展开更多
关键词 strain measurement strain sensor optical fiber sensor DISTRIBUTED micro bend
下载PDF
Stability Analysis of Contact Scanning Probe for Micro/Nano Coordinate Measuring Machine 被引量:2
17
作者 李瑞君 范光照 +3 位作者 钱剑钊 黄强先 龚伟 苗晋伟 《纳米技术与精密工程》 EI CAS CSCD 2012年第2期125-131,共7页
关键词 微纳米三坐标测量机 扫描探头 稳定性分析 传感哭喊中
下载PDF
5-羟色胺转运蛋白显像剂^(11)C-DASB的自动化合成及Micro PET/CT显像
18
作者 张晓军 刘健 +2 位作者 李云钢 田嘉禾 张锦明 《同位素》 CAS 2015年第1期1-6,共6页
目的:自动化合成5-羟色胺转运蛋白显像剂11 C-DASB并进行大鼠Micro PET/CT显像;方法:通过改变甲基化试剂、溶解前体溶剂及反应条件,得到优化的标记条件作为碳-11多功能合成模块的输入参数,进行自动化合成11 C-DASB,大鼠静脉注射11 C-DAS... 目的:自动化合成5-羟色胺转运蛋白显像剂11 C-DASB并进行大鼠Micro PET/CT显像;方法:通过改变甲基化试剂、溶解前体溶剂及反应条件,得到优化的标记条件作为碳-11多功能合成模块的输入参数,进行自动化合成11 C-DASB,大鼠静脉注射11 C-DASB 45 min后进行显像;结果:采用11 C-CH3-Triflate作为甲基化试剂,通入新配制的含1mg去甲基DASB前体的500μL DMSO溶液内,80℃下加热2min,标准率为63.7%,大鼠显像表明,11 C-DASB特异性的浓聚于SERT富集区域;结论:经优化,11 C-DASB自动化合成可得到较高产率,大鼠显像表明,其特异性浓聚于SERT富集区域,有望作为5-羟色胺转运蛋白显像剂。 展开更多
关键词 ^11C-DASB 5-羟色胺转运蛋白 micro PET/CT
下载PDF
用Micro-CT测量ICFT型源靶柱腔诊断孔轴线与靶杆夹角的研究
19
作者 刘学 叶成钢 +2 位作者 贾鹏 李佳 马小军 《上海计量测试》 2010年第2期22-24,26,共4页
用微CT测量ICF(惯性约束聚变)T型源靶柱腔诊断孔轴线与靶杆夹角(下文以θ代替)可以有效的排除柱腔外壁所镀金层厚度的不均匀对测量结果的影响。将微CT测量的两种方法与金层厚度均匀条件下用显微镜测量的结果进行比较,得出划定诊断孔上... 用微CT测量ICF(惯性约束聚变)T型源靶柱腔诊断孔轴线与靶杆夹角(下文以θ代替)可以有效的排除柱腔外壁所镀金层厚度的不均匀对测量结果的影响。将微CT测量的两种方法与金层厚度均匀条件下用显微镜测量的结果进行比较,得出划定诊断孔上下边界点找中心的微CT测量方法具有更高的可信度。 展开更多
关键词 微CT 测量精度 重复性 两种方法
下载PDF
^(18)F-氟赤硝基咪唑micro PET/CT评价裸鼠乳腺癌早期放疗疗效实验研究 被引量:3
20
作者 苏晓雨 徐慧琴 +3 位作者 汪会 余文静 张丹 谯凤 《安徽医科大学学报》 CAS 北大核心 2019年第2期203-206,共4页
目的探讨^(18)F-氟赤硝基咪唑micro PET/CT评价裸鼠MDA-MB231乳腺癌早期放疗疗效的价值。方法建立16只裸鼠MDA-MB231乳腺癌模型,将其按照随机对照原则分为两组:对照组(A组)、放疗组(B组),每组8只。每组裸鼠行micro PET/CT显像,测定每只... 目的探讨^(18)F-氟赤硝基咪唑micro PET/CT评价裸鼠MDA-MB231乳腺癌早期放疗疗效的价值。方法建立16只裸鼠MDA-MB231乳腺癌模型,将其按照随机对照原则分为两组:对照组(A组)、放疗组(B组),每组8只。每组裸鼠行micro PET/CT显像,测定每只裸鼠肿瘤SUVmax值。完成显像后,常规HE染色观察每组肿瘤组织形态学特征,免疫组化方法测定每组肿瘤细胞乏氧诱导因子-1α(HIF-1α)的表达情况。结果放疗前,对照组与放疗组SUVmax值差异无统计学意义(t=0. 375,P> 0. 05)。放疗组放疗后48 h裸鼠肿瘤组织SUVmax值较放疗前(t=9. 958,P <0. 05)、放疗后24 h(t=16. 506,P <0. 05)明显降低,差异有统计学意义(F=58. 860,P <0. 05)。放疗后24 h SUVmax值也低于放疗前24 h(t=5. 405,P <0. 05),差异有统计学意义。HE染色结果显示放疗组肿瘤细胞坏死较对照组更加明显。免疫组化结果显示放疗组放疗后HIF-1α表达阳性率明显低于放疗前(t=14. 802,P <0. 05),差异具有统计学意义。相关性分析结果显示肿瘤SUVmax与HIF-1α的表达呈明显正相关性(r=0. 865,P <0. 05)。结论^(18)F-氟赤硝基咪唑micro PET/CT可以监测肿瘤内部的乏氧状态,并且可以评价裸鼠MDA-MB231乳腺癌的早期放疗疗效。 展开更多
关键词 18F-氟赤硝基咪唑 micro PET/CT 放疗疗效 乏氧诱导因子-
下载PDF
上一页 1 2 103 下一页 到第
使用帮助 返回顶部